Quartz sand, grits ,fused silica , felsite powder, kynaite grits and lumps, pebbles.
Part No 1712
Part No 1716
Part No 1718
Part No 1719
Part No 1720
Part No 1721
Mini blade fuses AMPS Part No 5 2017 7.5 2018 10 2019 15 2020 20 2021 25 2022 30 2023
Slowblow AMPS Part No 5 2026 7.5 2027 10 2028 15 2029 20 2030 25 2031 30 2032
Drop out fuses and load-drop fuses are outdoor high voltage protection appliances. It is installed on the high voltage side of the distribution transformer or on the branch line of the distribution line. used as a short circuit of the transformer and the line, overload protection and split load current. The drop fuse is composed of two parts: An insulating bracket and a fuse tube. The static contact is installed at two ends of the insulating bracket, the movable contact is installed at both ends of the fuse tube, and the fuse tube is composed of an inner arc extinguishing tube and an outer layer. It consists of a phenolic paper tube or an epoxy glass tube. The load drop fuse enhances the elastic auxiliary contact and the arc extinguishing cover to divide and combine the load current. Product use environment: 1. The ambient temperature is not higher than +40 C, not lower than-40 C 2.The altitude does not exceed 3000m 3.The maximum wind speed does not exceed 35m/s 4.The earthquake intensity does not exceed 8 degrees Product Character: 1,High mechanical strength 2,Good pollution resistance performance 3,Acid and alkalis resistance 4,Good brittle resistance 5,Easy to install
Features:  99.99% pure silver fuse element was used,with internal solid quartz sand,strong resistance to impact and vibration,high fire resistance  It is applicable in the ambient temperature of -40ºC~95ºC,relative humidity is â?¤90% Characteristics:  Conforms to IEC 60269-1-4  High breaking capacity: 100ka  Small cleaning I2t  Low arc voltage and power losses
1. Use (H) RW 12-27 drop fuse and pull-load drop fuse are outdoor high-voltage protective appliances, which are assembled on the high-voltage side of distribution transformer or branch lines of distribution line, and are used for overload and short-circuit protection of transmission lines and power transformers and for sharing rated load current. 2. Brief introduction of structure The drop fuse consists of two parts: insulating bracket and fuse pipe. The static contacts are installed at both ends of the insulating bracket, and the movable contacts are installed at both ends of the fuse pipe. The fuse pipe consists of an inner arc extinguishing tube and an outer epoxy glass tube. Pull-load drop fuse adds elastic auxiliary head and arc extinguishing cover to divide and close load current. When a drop fuse is in normal operation, the fuse pipe is tensioned by means of the fuse. Then a closed position is formed. When the system fails, the fault current causes the fuse to fuse rapidly and form an arc. The arc extinguishing tube is heated by the arc and decomposes a large number of gases, which forms a high pressure in the tube and blows longitudinally along the pipeline. The arc is rapidly elongated and extinguished. After the fuse is fused, the lower moving contact loses tension and turns down. The locking mechanism releases the fuse tube, and the fuse tube falls down, forming an obvious breaking position. When the load needs to be pulled, the contact is pulled by the insulating rod. At this time, the active and static contacts are still in contact. The contacts are pulled by the insulating rod, and the auxiliary contacts are separated. Arc is generated between the auxiliary contacts. The arc is elongated in the slot of the arc extinguishing hood. At the same time, the arc is extinguished when the current passes zero. 3. Implementation criteria The product performance conforms to GB15166.3-94 national standard and IEC282-2 international standard. 4. Conditions of Use 1. Environmental temperature: - 40 ~40 C; 2. No more than 1200 m above sea level; 3. The wind speed is not more than 35m/s. 4. Earthquake intensity does not exceed 8 degrees. 5. Fuses are not suitable for the following places: A. Places where there is a danger of combustion or explosion; B. Places with violent vibration or shock; C. Areas with heteroelectrochemical gases, severe air pollution and salt fog. 5. Instructions for Order 1. Product type, name, rated voltage, rated current and rated switching-on current; 2. Environmental requirements (anti-pollution, plateau type); 3. Special requirements can be consulted with our company. Manufacturer of intelligent switch cabinet--low-voltage, high voltage power distribution switch cabinet, also have many other electric equipment electric power accessories, intelligent transmission and distribution automation system
Features/Benefits 600 V 110 -30 A Class CC and Midget fuse cover puller that offers increased protection when removing fuses. Simple removal without the need for a separate puller. Meets Dead Front requirements. Easily gangable with 1 8" diameter wire. For use with all 600 V Class CC and Midget 1 10 -30 A fuses. Label provided for easy fuse identification. Recommended Fuse Blocks L60030C and L60030M Ordering Information Poles Pack Quantity Catalog Number Ordering Number 1 10 SPL001 0SPL0001T 1 100 SPL001 0SPL0001H 2 5 DSPL001 DSPL0001Z 2 100 DSPL001 DSPL0001H 1 10 SPL001PCB SPL0001PCBT
CH modular, IP20 finger-safe DIN-Rail holders for Class CC, midget and PV fuses Bussmann series CH DIN-Rail fuse holders are for UL Class CC and midget fuses, and IEC 10x38mm fuses. They are available with and without indication in 1-, 2- and 3-pole IP20 finger-safe versions. A variety of accessories extends their application flexibility and they may be ganged together to meet specific application requirements. Ratings Volts 600 V (or less) UL 690 V (or less) IEC 1000 Vdc (or less) photovoltaic (PV) Amps 30 A UL 32 A IEC SCCR 33 kA photovoltaic 200 kA RMS Sym. (CHCC, CHM*) * CHM SCCR is fuse interrupting rating dependent. Agency information CHCC, CHM; UL Listed Guide IZLT, Recognized Guide IZLT2, File E14853 CHPV, UL Listed to 4248-19, Guide IZMR, File E348242 CSA File 47235, CHPV and CHM - Class 6225-30, CHCC - Class 6225-01 IEC 60269-2 (CHM, CHPV) CCC RoHS compliant CE Storage and operating temperature -4°F (-20°C) to +194°F (90°C) indicating -4°F (-20°C) to +248°F (120°C) non-indicating Features High SCCR rated, UL Listed Class CC holder with optional open fuse indication for 600 V and 48 Vdc (see catalog number table for details) Enhanced safety with IP20 finger-safe construction UL Recognized midget and IEC 10x38mm holders with factory assembled neutral pole option Agency ratings up to 1000 Vdc for use with PV fuses. Available remote PLC fuse indication module Wiring flexibility with terminals rated for use with 75°C or 90°C solid, stranded and fine stranded wire, and fork terminals and comb busbars. (Use any higher temperature insulations at the 90°C ampacity with appropriate derating.) Complete range of UL Listed and high SCCR rated one- and threephase finger-safe comb busbars and power feed lugs Optional hex head terminal screw makes it easier to achieve necessary torque values CHM1DIU CHM1DU CHM2DIU CHM2DU CHM3DIU CHM3DU CHM4DIU CHM4DU CHM1DNIU CHM1DNU CHM1DNXU CHM1DCIU CHM1DCU CHM2DCIU CHM2DCU CHM3DCIU CHM3DCU CHM4DCIU CHM4DCU CHCC1DIU CHCC1DU CHCC2DIU CHCC2DU CHCC3DIU CHCC3DU CHCC1DI-48U CHPV1IU CHPV1U CHPV2IU CHPV2U
CH modular, IP20 finger-safe DIN-Rail holders for Class CC, midget and PV fuses Bussmann series CH DIN-Rail fuse holders are for UL Class CC and midget fuses, and IEC 10x38mm fuses. They are available with and without indication in 1-, 2- and 3-pole IP20 finger-safe versions. A variety of accessories extends their application flexibility and they may be ganged together to meet specific application requirements. Ratings Volts 600 V (or less) UL 690 V (or less) IEC 1000 Vdc (or less) photovoltaic (PV) Amps 30 A UL 32 A IEC SCCR 33 kA photovoltaic 200 kA RMS Sym. (CHCC, CHM*) * CHM SCCR is fuse interrupting rating dependent. Agency information CHCC, CHM; UL Listed Guide IZLT, Recognized Guide IZLT2, File E14853 CHPV, UL Listed to 4248-19, Guide IZMR, File E348242 CSA File 47235, CHPV and CHM - Class 6225-30, CHCC - Class 6225-01 IEC 60269-2 (CHM, CHPV) CCC RoHS compliant CE Wire range 75°C and 90°C Cu 18-4 AWG (0.8-21.1mm2) Solid, stranded and fine stranded* * See data sheet 10430 for application details. Terminals Single or dual conductors Comb busbar Terminal screws Standard phil-slot Optional hex head (order by adding -H suffix to the catalog number, e.g., CHM1DU-H) Torque 30 lb-in (3.4 Nâ?¢m) maximum Flammability UL 94V0, self-extinguishing Storage and operating temperature -4°F (-20°C) to +194°F (90°C) indicating -4°F (-20°C) to +248°F (120°C) non-indicating Features High SCCR rated, UL Listed Class CC holder with optional open fuse indication for 600 V and 48 Vdc (see catalog number table for details) Enhanced safety with IP20 finger-safe construction UL Recognized midget and IEC 10x38mm holders with factory assembled neutral pole option Agency ratings up to 1000 Vdc for use with PV fuses. Available remote PLC fuse indication module Wiring flexibility with terminals rated for use with 75°C or 90°C solid, stranded and fine stranded wire, and fork terminals and comb busbars. (Use any higher temperature insulations at the 90°C ampacity with appropriate derating.) Complete range of UL Listed and high SCCR rated one- and threephase finger-safe comb busbars and power feed lugs Optional hex head terminal screw makes it easier to achieve necessary torque values CHCC1DIU CHCC1DU CHCC2DIU CHCC2DU CHCC3DIU CHCC3DU CHCC1DI-48U
Pboy series Rated voltage: 125Vdc Rated current: 5-500A Several control process for guaranteeing the comformity Grade H inported tube resisting high temprature and corrosion,more safety and reliable Integrated contacts,lower contacting resistance,low temprature rise and power loss gG characteristics,full range protaection Unique "quality tracking code"for each product
Bussmann is the world leading manufaturer for circuit protection. 170 series product is used widely in high power inverter, rectifier, convertors which need to protect the semiconductor. The product part no: 20 170m8 series, e.G:170m8056 170t7020 170e2091 170e2093 170e2095 170e2097 170e2098 170e2161 170e3579 170e3581 170e3586 170e3949 170e4276 170e5417 170e5420 170e5421 170e6143 170f3002 170f3003 170f3004 170f3005 170h3003 170h3004 170h3005 170h3006 170l7278 170l7290 170l7299-h 170l9572 170l9576 170l9578 170l9581 170l9583 170l9665 170l9868 170t8073 1~10pcs/box; Standard lot size: size000~size4 Weight: depends on products Dimensions: depends on products
Ptc resettable fuse: * widely used in the electrical appliance and circuit for over-current protection. * automatic reset * holding current : 0.020a~30a (thermal derating ) * operating voltage : 6v~600v * operating temperature available: -40c~80c * customized product improvement acceptable * agency approvalú¦iso9000, ts16949, ul, tuv, sgs, rohs * sample: free Negotiable
Complete range of EV Fuses, Pv Fuses, Semiconductor Protection Fuses, Fast Acting Fuses, Dc Fuses, Battery Protection Fuses, Etc By M/s Xian Sinofuse Electric, China
The Fuse in a plug is a safety device designed to protect the lead rather than the appliance. Buy Domestic plug Fuses in UK That are used in Variety of Electrical Household Appliances. Plugs for appliances rated between about 700 Watts and 3000 watts should be fitted with a 13-amp fuse. Order The Best Domestic Fuses from Kafton UK Cable Ties.