Ultraschall cavitation 1. Ultraschall-Frequenz: 40KHz 2. Ultraschall-Leistung: 50W 3. Ultraschall-Output-Modus: Hand-haltend Behandlungskopf (50mm Durchmesser, das um Rostfreien Stahl umläuft.) 4. RF Frequenz: 1MHz 5. RF Ausgangsleistung: 10W 6. RF Ausgangsart: Hand-haltender Behandlungskopf(bipolar, three-pole Behandlungskopf) 7. Die Nummer des Behandlungskopf:3(1für den Ultraschall, 2 für RF) 8. Die Grösse: 450 × 300 × 250mm 9. Das Gewicht: 7KG.
Lichtquelle: QS Nd: YAG solid-state laser Wellenlängen: 1064nm, 532nm Pulsenergie: von 200 bis 1000j (einstellbar) Pulsweite: bis 10ns Wiederholungsrate: wahlweise 1, 2, 3, 4, 5 ,6Hz Kühlung: Internes Wasser- und LuftKühlungsystem Größe: 48cm x 24cm x 24cm Nettogewicht: 10kg Leistungsanforderung: AC 220V±10% , 3A , 50Hz .
The goal of developing CM series laser equipments is to fully exert the machine's motion control capability and to further improve the processing quality. The ternet of serving for the field processing is emphasized on every aspects, whatever the software designing, mechanical structure,electrical performance or the selection of accessories. Quality management system has been fully executed in the prduction.Three major indicators of stability, precision and speed can represent the first class in the world. We keep improving CM series,and it has become the best carrier of laser processing--a new method in the industrial field. Laser power:30-150W Cutting thickness:0ú¡25mm(determined by materials) Engraving speed:0-64000(mm/min) Cutting speed:0-36000(mm/min) Winimum shaping character:Chinese character 2x2mm,Letter 1x1mm Resolution ration:í_ 4000 dpi Power supply:AC220Ví+ 10% ,50Hz Location procision:
Wavelength 980 nm Laser Output Power Up To 150~200 Watts Output Modes Continuous And Pulsed Length Of Pulses/Intervals 0.01-60s Transmission System 600ª¦m/800ª¦m/1000ª¦m Side-fire Fiber With SMA 905 Connector Avaliable,No Limit Aiming Beam 635nm ¿C 2mW Control Mode True Color Touch Screen Voltage/Current Rating 110V/220V, 50/60 Hz Dimensions 562(W)*420(L)* 267(H)mm Weight
1.Min order: one set 2.Certification: EN ISO 13485:2003 and MDD 93/42 EEC certificated by MEDCERT in Germany. 3. Competitive Price The prices of them are only 2/3 compared with the wholesale prices of the similar products. 4. After Sale Service Policy Would the products be broken in under warranty (not artificially), round-trip fare of the freight charge and insurance and all other costs of the defective goods are borne by our company. 5. Main Markets Europe and Middle East countries. 6. Main Markets Europe and Middle East countries. 7. Application - Endovenous Laser Treatment (EVLT) - ENT - Hemorrhoidectomy - Vaginal Rejuvenation - PLDD - Neurosurgery - Urology - Neoplasm. 8.Contact: Belinda Song. Dimensions 410(W)*330(L)*205(H) mm. Weight
Model: GREENLASER-04 Material: hard aluminum exterior surface treatment: black anode sclerosis switch: a rat tail + tactical point touch a switch battery: CR123 wavelengths: 532 nm Power :20-25 mW range:> 1,500 m start-up time: í_ 3seconds voltage: DC3.7V best temperature: 0 íµ ~ +35 íµ spot diameter: 6 M í_ ª¦10 mm 350g
Detail: Model:3-9í-32E Magnify ication:3-9í- OBJ LENSDIA(MM): 32 FIELD OF VIEW:7.5-2.5 WEIGHT(G):312 LENGTH (MM):300 EXT PUPIL(MM):90-67 EXT PUPIL DIA(MM):10.7-3.6 CLICK VALUE(MM):7 In bulk
Detail: The diameter: íí40mm Dot size: íí8 m.O.A* Length: íí5.8 inches Weight: íí6.8ounces Magnification: íínone(1x) Eye reliefú¦ ííunlimited Fielg of view: íí70 feet at 100 yards(optimum) Click adjustment: íí0.75 m.O.A* Power: íí2032 3v lithium *m.O.A. Stands for minute of angle 1m.O.A. Covers 1 inch at 100 yards In bulk
Parameters: Model: ML-LB2 Laser type: Q-Switched Nd: YAG Laser Laser wavelength: 1064&532nm Pulse energy: 0-800mj 0-300mj Width of Pulse(pulse duration): 0-10ns Repetition rate (pulse rate): 1, 2, 3, 4, 5, 6 (adjustable 0.5-3)Hz Light spot: 1-7mm Power supply: 220V, 6A or 110V, 12A With indicator laser light Net Weight: 9kgs; Size: 35cm*25cm*22cm Gross Weight: 16kgs Size: 50cm*35cm*30cm 1SET
Brief introduction: Simultaneously air temperature and set temperature display. Alarm functions for safety includes Power failure fan failure Over temperature temperature deviation Temperature probe failure >37 pc temperature setting. A keypad locks helps to prevent inadvertent changes to settings. Trough for pulling and pushing add the water and wash is convenient. Heater is electrically cut off if air /skin temperature inside incubator exceed 40fpc. Humidity is adjustable. The infant bed inclination angle is adjustable. Gross weight : Control cabinet: 120kg hood cabinet: 30kg Net weight: Control cabinet: 90kg hood cabinet: 10kg Measurement 1200*700*960mm
Microprocessor based servo controlled temperature system. The microprocessor-controlled unit allows for three settings, pre-warm, manual or automatic. Alarms functions for safety includes: Power failure temperature deviation Temperature probe failure over temperature Convenient x-ray cassette under infant bed. Three variable mattress tilts. Separate white lamp allows convenient observation. Adopts anti-explosion micro crystal quartz infrared radiation tube for its radiation source . Having quick heating and long life span. Digital display to indicate temperature. Have independent the second heat cuts off , the system is more safe. Protection when temperature probe in over temperature. Gross weight : 100kg net weight: 70kg Measurement: 1100*700*960mm
Brief introduction: Simultaneously air temperature and set temperature display. Alarm functions for safety includes Power failure fan failure Over temperature temperature deviation Temperature probe failure >37pc temperature setting. A keypad locks helps to prevent inadvertent changes to settings. Trough for pulling and pushing add the water and wash is convenient. Heater is electrically cut off if air /skin temperature inside incubator exceed 40pc. Humidity is adjustable. The infant bed inclination angle is adjustable. Technical specification: Electrical requirement : 220v+10%/50+2% Power supply : _420va Air temperature control range 2538 Temperature fluctuation: _0.5 Uniformity of mattress temperature: _0.8 Warm-up time: _45min Internal noise level: _55db Operation condition: Environment temperature: 2538 Environment relative humidity: 30%~75%rh Environment air velocity of flow:
Brief introduction: Microprocessor based servo controlled temperature system. The microprocessor-controlled unit allows for three settings, pre-warm, manual or automatic. Alarms functions for safety includes: Power failure temperature deviation Temperature probe failure over temperature Convenient x-ray cassette under infant bed. Three variable mattress tilts. Separate white lamp allows convenient observation. Adopts anti-explosion micro crystal quartz infrared radiation tube for its radiation source . Having quick heating and long life span. Digital display to indicate temperature. Have independent the second heat cuts off , the system is more safe. Protection when temperature probe in over temperature. Technical specification: Electrical requirement : 220v+10%/50+2% Power supply : _1500va Temperature control range: 32~38.5 Temperature probe accuracy: _0.3 Mattress temperature uniformity: _2.0 Warm-up time: _45min Adjustable horizon angle of radiator: +90 Operation condition: Environment temperature: 18~30 Environment relative humidity: 30%~75%rh Environment air velocity of flow:
Name: CO2 Fractional Laser Therapy Instrument Wavelength: 10.6m Output mode: fractional scanning mode, ultra pulse, continuous wave, repeat pulse Terminal output energy/power: 10-160mJ (scanning mode), 0.3-15W(Ultrapulse), 0.3-25W(continuous wave) Optional function: vaginal tightening function and nail fungus treatment function Certificate: Medical CE, ISO1348, free sales certificate
B. Braun offers a holistic infusion therapy concept which combines high-quality products with intelligent technologies and services
Theory The Professional OPT SHR IPL(Super Hair Removal) system emits varied wavelength, broad spectrum and intense pulse light, which permeate epidermis to the dermis of the skin. with the principle of selective absorption,the light is absorbed by the melanin in the hair follicles.Through the optical & thermal effect generated and sourced from the light, it achieves the purpose of removing unexpected hair by rapid destroying of hair follicle tissues. SHR stands for Super Hair Removal. Adopts Optimal Pulse Technology (OPT), is the most advanced adoption of pulsed light for hair removal and skin rejuvenation. The working principle is heating the dermis to a target temperature gradually, the target temperature damages the hair follicles and prevents re-growing, meanwhile avoiding injury to the surrounding tissue. High repeted pulses are delivered deep into the dermis, achieving high average power and effective heat, without risk of injury or pain.
Application of Fractional CO2 Laser Machina: Fractional mode (Aesthetic) + Pulse mode (Surgery) + Gynae mode (Gynecology Optional) Fractional mode: Skin rejuvenation, Wrinkles removal, Pigment removal, Acne treatment. Pulse mode: Sarcoma removal, Nevus removal, Grown nails removal, Skin tags removal. Gynae mode(Optional): Tighten, Lubrication, Sensitivity, Uremic Treatment.
Vertical Type Fiber Laser Marking Machine Fiber Laser Marking Machine Laser Marking Machine, Laser Marking Machine Manufacturer Features: 1.With foot wheels on the bottom of machine body, this vertical type laser marker can be easily moved to anywhere and fixed it to the ground. Itâ??s very good for marking on some heavy materials which is not easy to be moved. It can be compatible with conveyor belt working table for mass production line. 2. The marking head also can be adjusted for 100cm according to the different thickness of materials. (the height of marking head can be customized.) 3. High quality laser path suitable for delicate marking. Reach to the limit of diffraction. Export TEMOO of fundamental transverse mode. M2 near to 1. Beam divergence angle is only 1/4 of diode laser. Focus dot diameter is not over 20 um. 4. High pulse repeating rate and stable power bring high speed laser marking. Unit pulse power surge is lower than 1%. Easy control laser dot size, thickness and shape. 5. High speed 2-3 times over than traditional diode pumped marking machine. 6. Long lifetime. Ultra-low power consumption of 0.5kw. Efficiency conversion reaches to over 30 %. 7. Suitable for various fiber laser generators, make color-marking on stainless steel (code 304). Applications 1. Applicable Materials: Metal and various non-metallic materials, stainless steel, copper, iron, aluminum, carbon steel, titanium, high hardness alloy, oxide, printing ink, engineering plastics, electroplating materials, coating materials, epoxy resin, ceramic, ABS, PVC, PES, etc. 2. Applicable Industries: Mobile phone keypad, plastic translucent keys, electronic components, integrated circuits (IC), electrical, appliances, communication products, sanitary ware, measuring tools, accessories, knives, eyeglasses and clocks, jewelry, auto parts, plastic parts, medical equipment, luggage buckle, cooking utensils, stainless steel products, building materials and other industries.
808 Diode laser/candela laser best permanent hair removal I Theory 810nm system uses the unique laser with long pulse width 810nm to penetrate into hair follicle.Using the theory of selective optical absorption,laser can be preferentially absorbed by the melanin of the hair. And then the hair shaft and hair follicle are heated rapidly in order to destroy the oxygen-supply organization of and around the hair follicle. The system's unique super-cooling technology could bring about certain anesthetic effect to the epidermis with the output of the laser. Therefore, it could protect the skin from being hurt. As a result, a very safe and effective treatment is realized. II Applications: 1. Hair Removal for all of skin type and hair type. 2. Skin rejuvenation III Advantage 1. The laser wavelength The 810nm near infrared laser of Terminator Hair Removal System is best for absorbing melanin so that it can be applied to different parts and depth of the hair follicle to remove any type of the hair effectively. 2. Long laser pulse width The laser pulse duration of Terminator Hair Removal System is 10ms to 1400ms adjustable, which can impose effective treatments according to different hair to realize permanent hair removal. 3. No pigmentation. Suitable for any kind of skin. 810nm diode laser hair removal system uses the most advanced technology that penetrates deeper than before so that the skin could absorb less laser and there is no pigmentation. 4. Sapphire contact cooling system can make the treatment safer and no harm to the skin.The temperature of skin can be arrive at 0~5°C Sapphire contact cooling system of Terminator hair removal equipment can ensure the doctor could use the maximum energy but not to hurt normal skin. This cooling system can make sure no hurt to the skin when patients are given more pressure. It is reported that the pressure can increase 30%-40% of the luminous energy. 5. The squared big spot size can prompt the treatment speed. 810nm diode laser hair removal machine uses big squared spot size of 20mm which could ensure high efficiency and fast speed when executing the treatment of large area hair removal. Because the spot size is big, it could avoid repeated treatment.
Our Technology Advantages AFT Technology Adopt a multi-spectrum pulsed light which filters out the wavelength above 950nm to keep much water in the target skin so that the treatment is painless. EDF Technology To make sure the energy of every shot and pulse is the same and stable to keep safe treatment. In-montion Operation To shorten the time of treatment session, Accelerate the operation, save 1/2 treatment time Painless 1. Specific wavelength keeps much water in the target skin 2. EDF (Equally Distributed Fluence) ensures the uniform of energy Self-checking & monitor Monitor water circulation and identified handpiece to keep safe working Charging-Monitor Ensure the capacitors charging energy correctly Identified Handpiece Ensure safety Automatical Calibrate Constant and accurate energy output Application It could be used for hair removal and improving skin conditions. Besides, it can be used for all kinds of skin blemishes and skin diseases. Hair Removal Such as armpit hair, beard, lip hair, hairline, bikini hair, body hair Skin Rejuvenation Skin whitening, minimize pores, repair rough skin, enhance skin elasticity, smooth tiny wrinkles, eliminate and fade acne scars Pimples Acne, allergic acne, crusted acne Specifications Model S6 Light Source Pure Sapphire Spot Size SHR: 15*50mm SSR 8*40mm Wavelength 420-950nm for SAC(Optional), 570-950nm for SSR(Skin Rejuvenation), 650-950nm for SHR(Hair Removal) Power 220V/50Hz, 110V/60Hz Xenon Lamp Imported Lamp Fluence 1-7J/cm2 for SHR, 1-12J/cm2 for SSR(SAC, Optional) Timer 1s, 3s and 30s for SHR 1s, 2s, 12s for SSR(SAC, Optional) Frequency 3Hz for SHR, 2Hz for SSR(SAC, Optional) Intergrated Cooling 1-4 Degree Display 10.4" Colorful Touch Screen Calibrating Machine Automatic Calibrated Water Cooling Circulated Monitored In-scene Working Environment Indoor Use Only 35KG