Reflex gauge glass is used to read the medium level in the boiler or other tanks. The one side of the glass which is exposed to the medium has a prismatic surface and another side is smooth. The medium level inside the level gauge is indicated as the result of the light refraction principle, since the liquid filled area completely absorbs the rays of light and appears dark, whereas the rays of light are totally reflected in the gas/air filled area which appears bright. Reflex gauge glass is made from high borosilicte glass. It has many advantages, such as cheap, low maintenance cost, easy level reading and excellent high temperature & pressure resistance. Its working pressure can be up to 4 MPa and working temperature can be up to 430 C. The edge can be polished or frosted.
The vibration-proof Pressure gauge is applied to the occasion with dynamic load and vibration or to measure the pressure of gas and liquid which can not corrode copper alloy. It is widely used in machinery, petroleum, chemical, metallurgical, mining, and electric power sector. Measuring the pressure of the high corrosion media, the material should be stainless steel-vibra- tion-proof and anticorrosive (such as Acid alkal ammonia). Parameters: Dia : 60mm 100mm 150mm Working pressure : The pressure gauge should not exceed 3/4 of the maximum scale value under steady pressure and not exceed 2/3 of the maximum scale value under fluctuation pressure and not exceed 1/3 of the maximum scale value under short-time pressure. Connection Thread : M14 1.5 M20 1.5 PF(PT NPT)1/4PF(PTNPT)1/2 Damping Liquid : methylsilicone Bourdon tube : sus304 or sus316 Connection material : sus304 or sus316 Welding way : TIG Movement : SUS304 Casing : SUS304 Glass : PC, stalinite, double pane safety glass With a sharp pressure changes or vibration environment. Plus environment protection device shall be added. Pressure gauges shall be horizontal or vertical installation. The pressure gauge must be installed vertically and tightened by a wrench. Measurement with explosion danger, easy to crystallization, easy solidified, corrosion resistance requirements, special medium measuring instrument should be used. Measurement of oxygen, acetylene, hydrogen, or other combustible gas should be chosen with ban oil logo pressure gauge. The pressure gauge is to be used at an ambient temperature between -35~+70 with a relative humidity not exceeding 85% ( close to the lowest temperature will affect the normal work of the instrument).
Linshang LS223 coating thickness gauge also called coating thickness tester is an instrument that separates the host from the probe. The measuring range is 5000¼m and the meter can automatically identify the measuring substrate. This instrument uses both Hall Effect and eddy current measurement principles to measure the non-magnetic coating thickness on magnetic substrates and the non-conductive coating thickness on non-magnetic substrates. It is a dual-use instrument for both ferrous and non-ferrous substrates.
Automotive paint meter, also called car paint meter, is a special instrument for detecting the automobile substrate surface coating thickness. The covering surface of a car basically has a paint coating. Using a automotive paint meter to measure the paint surface coating thickness can directly determine the sheet metal and spray paint of a car. It can also indirectly determine the damage degree of the car. The LS220 automotive paint meter has small size and is especially suitable for carrying around when going out for inspection. This car paint thickness gauge has the characteristics of fast test speed, stable test data, high measurement accuracy and so on.
Features Design as per IS 6137-1983 taper lock design. Gauging practice as per IS 3455-1971. Material En31.
Master Setting Ring gauges are ideals for setting bore measurement instrument. Features: Manufacturing Range : 4.00 mm to 500 mm. Material : OHNS , En 31 Alloy steel. Blank Design as per IS 3485 1983. Gauging practice as per IS 3455 1971. Are ground and precision lapped after a heat treatment process which includes subzero stabilization cycle to ensure dimensional stability. Calibration under standard room temperature at 20 degree celsius on carl zeiss,Horizontal Metro scope which is traceable to National Standards.
All Water Treatment products EMFT, FT, Media, Pressure Gauge, Ro membrane Housing
2 in. Gas Test Pressure Gauge with Test Valve Adapts to 3/4 in. FNPT and Range of 0-30 psi/kPa Suitable for non-clogging and non-corroding media Features brass wetted parts Connection: Adapts to 3/4 in. NPTF
2 dial size Copper alloy bourdon tube and socket Black steel case 1/2³, 3/4³ or 1³ FNPT connections Plastic, snap-in lens Accuracy: 3/2/3% per ASME B40.1 Grade B White Scale with black graduations and numerals Horizontal or vertical housing or Installed horizontal or vertical with manifold
Description: Drift Diameter Gauge is a special tool for testing the diameter of downhole tubular. It is mainly used to test whether the diameter of the inner diameter of the casing, tubing, drill pipe, etc. meets the standard, and is a commonly used testing tool for underground operations.
ODMT MPGC series pressure gauge calibration table is applicable for testing spring tubes (C-type tube, coil spring tube, spiral tube), etc. The calibration pressure of pneumatic calibration table is up to 15Mpa and that of hydraulic calibration table is up to 250Mpa. (Customers can consult our company on phone for more information about calibration tables with higher test pressure.) Pneumatic Calibration Table (0-15Mpa) Main Characteristics: Users prepare calibration gas source themselves or the system is equipped with pressurization device additionally. Pressure regulating device with high precision controls the gas pressure of the system. This device makes it stable and precise to increase or reduce pressure during the calibration. All the pipelines, connectors, etc. adopt highly reliable seals, preventing the phenomena of leakage. The technology of quick manual connector on pressure gauge is internationally advanced. This kind of connectors has long lifespan and no leakage. Two pressure gauges can be tested synchronically, which can improve working efficiency. The calibration table has closed structure and beautiful design. It is easy to operate and maintain. It can measure the pressure, voltage and current, and outputs direct current 24V, which makes it convenient for users to test pressure sensor, digital pressure gauge or other pressure instruments.
Description: Drift Diameter Gauge is a special tool for testing the diameter of downhole tubular. It is mainly used to test whether the diameter of the inner diameter of the casing, tubing, drill pipe, etc. meets the standard, and is a commonly used testing tool for underground operations. Picture:
Transparent glasses are also manufactured from extra-hard borosilicate glass. The surfaces on both sides are finely smooth and ensure optimal transparency. Now we have two kinds manufacturing technique: 1.One is as same with reflex gauge glasses, use molds to make the semi-finished products, afterwards, ground and polish the two side to ensure optimal transparency. By this manufacturing technique, the definition isnt good. 2.The other manufacturing technique is: At first, we manufacture 17mm thickness glass sheet, then cut the glass sheet according the detailed size and polish the side face for the smooth. This manufacturing technique glass is very clear, but the goods cost is higher. It can be used with all media except steam at service conditions up to 6MPa and temperatures up to 260 °C.
Pressure gauge adaptors. Convenient for pressure gauge fitting to the system. Male end into pump or cylinder pot, female end accepts hose or coupler, 3rd port is for gauge connection.
Drift Diameter Gauge is a special tool for testing the diameter of downhole tubular. It is mainly used to test whether the diameter of the inner diameter of the casing, tubing, drill pipe, etc. meets the standard, and is a commonly used testing tool for underground operations.
Ammonia vacuum pressure gauge: 1.Plexiglass Dial 2.Clear Reading 3.Pressure variation drives elastic components 4.The pointer corresponds to the pressure value 5.Easy to Read
Application: Suited for low pressure measurement of high corrosive,vascous media. Outside diameter:100,160 Accuracy:1.5%.2.5% Range:1kpa-2.5MPA Case & Internals material:Stainless Steel Diaphragm material:SUS304,SUS316,3J
Application: Are built for maintaining maximum safety when measuring pressure. Accuracy:1% Blow out back,stainless steel safety case design Wetted part sus 316 Range:-0.1~100MPA Laminated safety glass
Description: Mini digital pressure gauge used diffused silicon pressure sensor as the core pressure-sensitive components together with a low-power circuit, a section of ordinary 9V battery can be used for more than a year, accurate and convenient. The intelligent digital pressure gauge flexible, easy to operate, easy to debug, safe and reliable. Widely used in water and electricity, water, petroleum, chemical, mechanical, hydraulic and other industries on the pressure of the fluid medium measurement display. Parameter: Pressure range: -0.1 ~ 60MPa (custom specific pressure ranges) Accuracy: 0.2, 0.4 Threaded connection: M20 * 1.5 M14 * 1.5 1 / 2NPT 1 / 4NPT or other custom thread Display: 4 LCD Power supply: 9V battery (power range is available between 3.6V ~ 9V) Power: 200UA Calibration: Support button calibration, enabling customers to be calibrated in the field, without Depot Features: Large-screen LCD display, high resolution Peak hold function to record the maximum pressure during the measurement value Pressure percentage dynamic display, (the progress bar shows) Five kinds of engineering unit selection: psi, bar, kpa, kg / cMpa Select 1 ~ 15min automatic shutdown feature. Micro-power, power-saving mode can work in more than two years of continuous work 2000 hours. Parameter correction function, the instrument can live zero error value correction. Upper and lower limit range Sampling rate: 4 times / sec. Apply pressure of various gases compatible with stainless steel measuring liquids
Normal Size: 1.5"(40mm),2.0"(50mm),2.5"(63mm), 3"(75mm),4"(100mm),6"(150mm). Pressure Range: -1Bar(-30"Hg)-0-1000Bar(15000Psi) Accuracy: ±1%,±1.6% Operating temperature: -20°C to +60°C Case: Stainless steel Bezel: Stainless steel Bourdon tube: Copper alloy or Stainless steel