Product Introduction Relays are widely used in railway signal technology, called signal relays, which are important components in railway signal technology. It plays an important role no matter as the core component of the relay signal system or as the interface component of the electronic or computer signal system. The reliability of the relay action directly affects the reliability and safety of the signal system. The JZXC-H62 rectifier slow release relay is an important component in the chain equipment and the main equipment to ensure the safe operation of the system. The signal relay can control the switching, locking and unlocking of the turnout, and control the opening and closing of the signal machine, etc. . Its reliability, availability, maintainability and the entire sauna line are the keys to the safety of railway transportation and operational services. The automatic control systems in various fields all use relays. Product Usage JZXC-H62 type rectifier slow release relay is used in signal circuit for turnout display circuit and single-multi-line semi-automatic blocking circuit. Features JZXC-H62 rectifier slow release relay is one of the main components in railway signal equipment. Its reliability and safety in use are necessary requirements to ensure the normal operation of various automatic control and remote control signal equipment. Product function The signal relay is an important component in the interlocking equipment, and is the main equipment to ensure the safe operation of the system. The signal relay can control the switching of the turnout, lock and unlock the route, and control the opening and closing of the signal machine. Its reliability, availability, maintainability and the entire sauna line are the keys to the safety of railway transportation and operational services. Applicable environment a) Ambient temperature: -40~+60; b) Relative humidity: not more than 90% (temperature +25); C) Air pressure: not less than 70kPa (equivalent to below 3000m above sea level); d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm; e) Working position: horizontal; f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken. Executive standard Q/SX0410.06-2012 "AX Series Relay" Product Features Mechanical properties Number of contact groups: 4QH; Identification pin number: 13, 53; Contact gap: not less than 1.3mm; Pallet gap: not less than 0.35mm; Contact pressure: the dynamic contact point is not less than 250mN; the dynamic disconnection point is not less than 150mN; Contact uniformity error: not more than 0.20mm.
Product Introduction JZXC-H142 type rectifier slow release relay is an important component in interlocking equipment. It is the main equipment to ensure the safe operation of the system. The signal relay can control the switching, locking and unlocking of the turnout, and control the opening and closing of the signal machine, etc. . Its reliability, availability, maintainability and the entire sauna line are the keys to the safety of railway transportation and operation services. The automatic control systems in various fields all use relays. Relays are widely used in railway signal technology, called signal relays, which are important components in railway signal technology. It plays an important role no matter as the core component of the relay signal system or as the interface component of the electronic or computer signal system. The reliability of the relay action directly affects the reliability and safety of the signal system. Product function JZXC-H142 rectifier slow release relay is a commonly used electrical appliance in automatic control systems. It is used to connect and disconnect circuits, to issue control commands and reflect the status of equipment to form automatic control and remote control circuits. Product Usage The JZXC-H142 rectifier slow release relay is used in the signal circuit for the LED signal lighting circuit. Applicable environment a) Ambient temperature: -40~+60; b) Relative humidity: not more than 90% (temperature +25C); c) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m); d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm; e) Working position: horizontal; f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken.
product description The JZXC-H60 rectifier slow release relay is an important component in the interlocking equipment, and the main equipment to ensure the safe operation of the system. The signal relay can control the switching, locking and unlocking of the turnout, and control the opening and closing of the signal machine, etc. . Its reliability, availability, maintainability and the entire sauna line are the keys to the safety of railway transportation and operational services. The automatic control systems in various fields all use relays. Product Usage The JZXC-H60 rectifier slow release relay is used in the signal circuit for the LED signal lighting circuit. Applicable environment a) Ambient temperature: -40~+60; b) Relative humidity: not more than 90% (temperature +25); c) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m); d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm; e) Working position: horizontal; f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken. Mechanical properties Number of contact groups: 4QH; Identification pin number: 13, 53; Contact gap: not less than 1.3mm; Pallet gap: not less than 0.35mm; Contact pressure: the dynamic contact point is not less than 250mN; the dynamic disconnection point is not less than 150mN; Contact uniformity error: not more than 0.20mm. Electrical characteristics Magnetizing value: AC240Ma Release value: not less than AC30Ma Working value: not less than AC60ma Coil resistance: 30 (1±10%) Q2 The coils are connected in series, connect 1, 4, use 5, 6;
Product Usage The JZXC-H156 rectifier slow release relay is used as a filament supervisory relay in the electric centralized lighting circuit. Applicable environment a) Ambient temperature: -40~+60; b) Relative humidity: not more than 90% (temperature +25C); c) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m); d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm; e) Working position: horizontal; f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken. Mechanical properties Number of contact groups: 4QH; Identification pin number: 22, 53; Contact gap: not less than 1.3mm; Pallet gap: not less than 0.35mm; Contact pressure: the dynamic contact point is not less than 250mN; the dynamic disconnection point is not less than 150mN; Contact uniformity error: not more than 0.20mm. Electrical characteristics Rating: AC51MA Magnetizing value: AC136Ma Release value: not less than AC12Ma Working value: not less than AC34ma Coil resistance: 78 (1±10%) Q2 The coils are connected in series, connect 1, 4, use 5, 6;
Product Usage The JZXC-H156 rectifier slow release relay is used as a filament supervisory relay in the electric centralized lighting circuit. Applicable environment a) Ambient temperature: -40~+60; b) Relative humidity: not more than 90% (temperature +25C); c) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m); d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm; e) Working position: horizontal; f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken. Mechanical properties Number of contact groups: 4QH; Identification pin number: 22, 53; Contact gap: not less than 1.3mm; Pallet gap: not less than 0.35mm; Contact pressure: the dynamic contact point is not less than 250mN; the dynamic disconnection point is not less than 150mN; Contact uniformity error: not more than 0.20mm. Electrical characteristics Rating: AC51MA Magnetizing value: AC136Ma Release value: not less than AC12Ma Working value: not less than AC34ma Coil resistance: 78 (1±10%) Q2 The coils are connected in series, connect 1, 4, use 5, 6;
Product Usage The JZXC-H18 rectifier slow release relay is used as a filament supervisory relay in the electric centralized lighting circuit. The use of dual coils is to enhance the flexibility and flexibility of the control circuit, which can be controlled by a single coil or a series of double coils according to the circuit needs. The armature is fixed on the blade of the armature by the butterfly-shaped steel wire, and it moves flexibly. There is a heavy hammer in the transmission part of the armature to ensure that the relay armature returns reliably by gravity. The number of weights installed is determined by the structure of the relay contact system, and should be able to ensure the reliable release of the relay. A stop piece is installed at the closed position of the armature and the iron core to ensure the minimum air gap of the magnetic circuit of the relay, prevent the ferromagnetic parts of the magnetic circuit from magnetizing, and ensure that the relay falls reliably. The iron core, vehicle iron and armature of the relay are made of electromagnetic pure iron, which has high magnetic permeability and small remanence. Product characteristics Mechanical characteristics Number of contact groups: 4QH; Identification pin number: 13, 53; Contact gap: not less than 1.3mm; Pallet gap: not less than 0.35mm; Contact pressure: the dynamic contact point is not less than 250mN; the dynamic disconnection point is not less than 150mN; Contact uniformity error: not more than 0.20mm. Electrical characteristics
Product Introduction JWJXC-H125/0.44 stepless enhanced contact slow release relay is an important component in interlocking equipment and the main equipment to ensure the safe operation of the system. The signal relay can control the switching, locking and unlocking of the turnout, and control the opening and Close and so on. Its reliability, availability, maintainability and the entire sauna line are the keys to the safety of railway transportation and operational services. The automatic control systems in various fields all use relays. Relays are widely used in railway signal technology, called signal relays, which are important components in railway signal technology. It plays an important role no matter as the core component of the relay signal system or as the interface component of the electronic or computer signal system. The reliability of the relay action directly affects the reliability and safety of the signal system. Product Usage JW.JXC-H125/0.44. The stepless strengthened contact slow release relay is used as a general relay in the signal circuit. Applicable environment a) Ambient temperature: -40~+60 b) Relative humidity: not more than 90% (temperature +25); C) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m); d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm; e) Working position: horizontal; f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken. Structural characteristics Mechanical properties Number of contact groups: 2QH, 2QJ, 2H; Identification pin number: 15, 55; Ordinary contact gap: not less than 1.3mm; Strengthen the contact gap: not less than 2.5mm; Ordinary pallet gap: not less than 0.35mm; Reinforce the gap of the support plate: not less than 0.1-0.3mm; Ordinary contact pressure: dynamic closing or positioning contact not less than 150mN; dynamic breaking or reverse position contact not less than 150mN; Strengthen the contact pressure: the dynamic closing or positioning contact is not less than 400mN; the dynamic breaking or reverse position contact is not less than 300mN; Contact uniformity error: not more than 0.20mm.
Product Usage The JZXC-H18 rectifier slow release relay is used as a filament supervisory relay in the electric centralized lighting circuit. Installation Precautions 1. When installing the relay, make sure that the insulation interval between the sockets is intact, the socket hanging spring is intact, and the socket identification pin is in the correct position and should not be missing. 2. Pay attention to the relative position between the relay and the socket when plugging in the relay to avoid damage to the relay or socket during plugging. 3. When repairing and replacing the relay, first remove the fixed relay spring, and then pull out the relay. Do not use excessive force or shake left and right when pulling it out, as it may damage the relay or socket. Applicable environment a) Ambient temperature: -40~+60 b) Relative humidity: not more than 90% (temperature +25); c) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m); d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm; e) Working position: horizontal; f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken. Product electrical life The relay contact is connected to DC24V1A resistive load; its electrical life is 1Ã??106 times Structural characteristics The electromagnetic system includes coils, iron cores, irons and armatures. The coil is installed horizontally on the iron core, and is divided into a front coil and a back coil. It is mainly to install a half-wave or full-wave rectifier circuit composed of diodes above the contact group.
product name There are extremely strengthened contact relays: JYJXC-160/260 Product Usage The JYJXC-160/260 type has pole reinforced contact relay is used as a two-start relay in the signal switch control circuit. Mechanical properties Number of contact groups: 2DF, 2DFJ; Identification pin number: 15, 54; Contact gap: ordinary contact is not less than 4.5mm; reinforced contact is not less than 7mm; Pallet gap: ordinary contact point is not less than 0.35mm; Ordinary contact pressure: the positioning contact is not less than 150mN; the reverse contact is not less than 150mN; Strengthen the contact pressure: the positioning contact is not less than 400mN; the reverse contact is not less than 400mN; Contact uniformity error: no more than 0.2mm between ordinary contacts and ordinary contacts and between ordinary contacts and reinforced contacts, and no greater than between reinforced contacts and reinforced contacts 0.1mm. Positioning or reverse position holding force is not less than 4N; Electrical characteristics (at 20c) Coil resistance: 135/220Q Use the coil alone, use 1, 23, 4; Rated value: 24V; Magnetizing value: 64V/64V; Rotation extreme value: forward 10V~16V, reverse 10V~16V; Contact resistance: common contact is not more than 0.05; strengthened contact is not more than 0.1Q. Product function The signal relay is an important component in the interlocking equipment, and is the main equipment to ensure the safe operation of the system. The signal relay can control the switching of the turnout, lock and unlock the route, and control the opening and closing of the signal machine. Its reliability, availability, maintainability and the entire sauna line are the keys to the safety of railway transportation and operational services. Insulation withstand voltage Under the standard atmospheric conditions of the test, the insulation resistance of the relay should not be less than 100MQ. Under the condition that the air pressure is not less than 86kPa (equivalent to the altitude below 1000m), the insulation withstand voltage of the relay should be able to withstand AC sine wave 50Hz, 2000V rms voltage, there should be no breakdown flashover after 1 min, and the voltage during repeated test should be 75% of the original test voltage. Product electrical life The ordinary contact of the relay is connected to DC24V1A resistive load; the strengthened contact is connected to DC220V7.5A, 0.05H inductive load, and its electrical life is 1105 times.
bms products are battery management systems developed for large-scale high-voltage battery energy storage systems. It adopts distributed architecture, modular design concept, high configurability, easy assembly, debugging and maintenance. It is suitable for various battery energy storage systems with dc voltage below 1000v. This product can be configured as a secondary architecture (bmu+cbms) for 10kwh-100kwh. Cooperate with industrial computer and battery stack management software to form a three-level architecture (bmu+cbms+gbms) for 50kwh-2mwh applications. In conjunction with the server and plant battery management system software, it can form a four-level architecture (bmu+cbms+gbms+bbms) for applications from 2mwh to 1000mwh to meet different project requirements the product has a complete and reliable operation and protection strategy to effectively extend the life of the battery pack. It comes with a variety of communication interfaces and can be directly or indirectly connected to third-party energy management systems.
Manufacturer:Panasonic Product category:Low signal relays - pcb Rohs:Rohs compliant by exemption Brand:Panasonic industrial devices Product:Slim form relays Contact form:Dpdt (2 form c) Contact current rating:1 a Coil voltage:12 v Maximum switching current:1 a Coil current:11.7 ma Coil type:Non-latching Power consumption:140 mw Contact rating:1 a at 30 vdc / 300 ma at 125 vac Contact termination:Solder pin Mounting style:Through hole Packaging:Tube Factory pack quantity:50 Search:
Lenovo Dell Asus Used Grade A/Grade AB Gaming laptops
All Kinds of Used Laptops Lenovo Asus Apple Dell and many more, in Grade A/AB/C
DELL LATITUDE 14 5430 CHROMEBOOK GRADE A 12TH GEN I5 8GB/256GB AUE 2032 MODEL NUMBER: P163G
HP Elitebook 840 GRADE AB 840 G5-G8 G7 and G8
22000+ qty laptop batteries the battery life will be 85-90%
900pcs of Desktops available for sale contact .
300pcs Brand:- HP Model:- 840 G6 & 850 G6 CPU:- i5 & i7 Gen:- 8th RAM/SSD:- 16/256GB Grade:- B/B+ Qty:-300pcs AC Adapter:- included
Sensors, encoders, cable relays, industrial cables, partex marking system, cable conduits.
Domestic wire, house wire, submersible cables (flat / round), single core flexible cable, multi core flexible cable, xlpe insulated pvc sheathed power cable, xlpe insulated armoured control cable, pvc insulated armoured control cable, xlpe insulated unarmoured control cable, pvc insulated unarmoured control cable, optical fiber cable, optical fiber armoured cable, ftth drop cable, instrumentation cable, shielded cable. networking cable, cat 6 cable, cat 6 utp cable, cat 6 stp cable, cat 6 sftp cable, cat 6 ftp cable fire alarm cable, fire survival cable, data cable, electric cable, coaxial cable, cctv cable, travelling cable, lift cable, lift traveling cable.