100 mA, 100 KVP Mobile X-ray Machine 100mA, 100 KVP, Mobile X-ray Machine for Radiography only Electronic Timer Electronic Overload Protection Device Stationary Anode X-ray Tube : BEL or Imported Collimator Counter Balanced Mobile Stand Suitable for Bed Side X-rays
Suited to a range of imagers and general radiology applications Five film sizes on 7-mil blue polyester base AIQC system-matched with the DRYVIEW Laser Imagers AIQC ensures contrast and density meet preset user preferences Quality control performed without operator intervention to enhance productivity Storage and Handling of Film Unexposed DRYVIEW DVE Film must be stored at 39 to 75�?�°F (4 to 24�?�°C), at 30 to 50% RH, and properly shielded from x-rays, gamma rays, or other penetrating radiation in order to achieve consistent results up to the expiration date indicated on the film package. Note that DRYVIEW models 8700, 8150 and 8300 are not compatible with DVE Film. To determine if your laser imager needs a software upgrade or is compatible with DVE �¢?? download our information sheet here. Choose from five sizes on 7-mil polyester base to suit your DRYVIEW Laser Imager and imaging applications: 14 x 17 in. (35 x 43 cm.) 11 x 14 in. (28 x 35 cm.) 10 x 12 in. (25 x 30 cm.) 8 x 10 in. (20 x 25 cm.)
There are many different models available for an X-ray baggage scanner, depending on the location and purpose of the X-ray scanner. The tunnels of the x-ray baggage scanner are determined according to the place to be used. 50x30 tunnels are usually suitable for places entered with handbags, such as shopping mall entrances, public institutions, and organizations; as the size of the package to be controlled increases; 65x50, 80x65, or 100x100 will be more convenient. Sites such as airports, bus terminals, hotel entrances should prefer devices with large tunnel measurements.
We're a leading XRay machine and accessories manufacturer company with over 29 years of experience and global presence and distributor network in 7 different countries. We have Line Frequency & High Frequency, APR X-Ray Machine, Dental X-Ray Machine, Mobile 100MA X-Ray Machine, 300MA X-Ray Machine, 500MA XRay Machine, Vertical Bucky, Multi-Position Bucky Table, 4 & 2 Way Floating Bucky Table Etc Beside new machines, we offer complete modification & repairing of any brand XRay machines, Rotating Anode Tube Head, HT 100MA, 300MA, 500MA Etc
Power Output 5.0KW x ray machine Main Inverter frequency 40 KHz X-ray Tube of radiography machine fixed anode focus: 1.5 (X-ray tube for high frequency) Power Supply 220V�±10% 50Hz Inner-resistance â?¤1.0�© Operation Method Wire/wireless control mobile x-ray machine safety mobile x ray machine cost mobile x ray machine price
2.5kw high frequency portable X-ray machines PLX101 x ray tube Fixed Anode Power Output of x ray machine 2.5kW Frequency 25kHz Tube voltage 40~100kV Power Supply 220V�±10%, 50kHZ Operation Method Wire/ Wireless control price list of x-ray machine price of 500ma x-ray machine price of medical x ray machine
brand of surgical x-ray equipment PLX101D mobile x ray machine for sale price of x ray machine mobile x ray machine specifications Power Output 5.0KW x ray machine Main Inverter frequency 40 KHz X-ray Tube of radiography machine fixed anode focus: 1.5 (X-ray tube for high frequency) Power Supply 220V±10% 50Hz Inner-resistance Operation Method Wire/wireless control
Available in all sizes
X-ray machine Technical parameter 1. The numbers of x-ray tubes used in the product are also used as product number and x-ray generator (bulb tube head) number. 2. The current and voltage of x-ray tubes are fixed in three groups, they are: X exposure voltageú¿kvpú¬ 60 65 70 X-ray currentú¿maú¬ 0.50 0.85 1.10 3. When adding up voltage, total current is less than 2a and total power is 500w 4. Drain current and earth resistance are in accordant with the stipulates in gb9706.1 5. The three groups of voltage (60kvíó65kvíó70kv) are adjustable. 6ú«wireless remote control in any angles within 10 meters part form the control box 7. The parameter of x-ray generator (bulb tube head) 7.1. The parameter of x-ray tubes A. Focus index: 0.3í-0.3mm2 Bú«the voltage of the-highest-voltage generator: 90kv C. The highest inverse peak voltage: 90kv D. Filament characteristic: vf=5ví+0.5vú¼if=3a E. Target surface obliquity: 12íp F. The cooling manner of bulb tube head: oil immersion 8.7.2 the parameter of x-ray generator (bulb tube head): A. Focus-skin distance: 200mm B. The thickness of filter-ray film: more than 1.5mmal C. The leakage rate of x-ray: no more than 0.002mgy/h (no. 29.204.3 in gb9706.12 prescript that the leakage rate of x-ray is no more than 0.25mgy/h) D. The manner of limiting beam: using planigraphic device
Technical parameter 1. The numbers of x-ray tubes used in the product are also used as product numbers and x-ray generator (bulb tube head) numbers. 2. The current and voltage of x-ray tubes are fixed in three groups, they are: X exposure voltage (kvp) 60 65 70 X-ray current (ma) 0.50 0.85 1.10 3. When adding up voltage, total current is less than 2a and total power is 500w 4. Drain current and earth resistance are in accordant with the stipulates in gb9706.1 5. The three groups of voltage (60kv, 65kv, 70kv) are adjustable. 6. Wireless remote control in any angles within 10 meters part form the control box 7. The parameter of x-ray generator (bulb tube head) 7.1. The parameter of x-ray tubes A. Focus index: 0.3í-0.3mm2 B. The voltage of the-highest-voltage generator: 90kv C. The highest inverse peak voltage: 90kv D. Filament characteristic: vf=5ví+0.5v, if=3a E. Target surface obliquity: 12íp F. The cooling manner of bulb tube head: oil immersion 7.2 the parameter of x-ray generator (bulb tube head): A. Focus-skin distance: 200mm B. The thickness of filter-ray film: more than 1.5mmal C. The leakage rate of x-ray: no more than 0.002mgy/h (no. 29.204.3 in gb9706.12 prescript that the leakage rate of x-ray is no more than 0.25mgy/h) D. The manner of limiting beam: using planigraphic device
Features: 1. One-button shutdown: turn off only need to turn the key, the device automatically safe shutdown, more humane. 2. Emergency stop hierarchical control: press the tight stop button, only the power transmission and ray source part, more secure. 3. Image ultra-clear: the core components of high-density imported modules, higher resolution, to the international level, more clear. 4. Waterproof function: the channel within the special treatment,there is no effect a small amount of passengers scattered liquid, more at ease. 5. self-diagnosis: automatic fault diagnosis, and give a message, easy to maintain. 6. zoom function: continuous mouse zoom function, more continuous. Unique mouse magnifying glass function, any local details zoom, more accurate. Has a specific role in identifying specific explosives. 7. Detection of objects: parcels, small bags, suitcases, bags and other small objects. Applications: 01. Airports, 02. Transport terminals, 03. Buildings, 04. Factories (to find needle in clothing, shoes, bags), 05. Courthouses, 06. Embassies, 07. Military installations, 08. Prisons, 09. Hotels, 10. Schools , 11. Convention centers, 12. Security checkpoints 13. Special events location technical standard Electrical appliances with reference to EN60950 safety standards Radiation is carried out with reference to EN50081-1 Strict implementation of the current X-ray security equipment national standards Fully through the ISO14001: 2004 environmental management system certification Fully through the OHSAS18001: 2007 occupational health and safety management system certification Fully passed ISO9001: 2000 quality management system certification Technical Parameters: Dimensions: 1650 (length) x722 (width) X1150 (high) mm Channel Size: 500 (W) X300 (H) mm Conveyor speed: 0.22m / s Conveyor max load: 150kg Resolution: diameter 0.07871mm metal wire Spatial resolution: horizontal diameter 1.0mm; vertical diameter 1.0mm Penetration: 10mm ~ 40mm steel plate (can be customized) Film safety: Safety for IS01600 film Leakage dose:
Features: 1. One-button shutdown: turn off only need to turn the key, the device automatically safe shutdown, more humane. 2. Emergency stop hierarchical control: press the tight stop button, only the power transmission and ray source part, more secure. 3. Image ultra-clear: the core components of high-density imported modules, higher resolution, to the international level, more clear. 4. Waterproof function: the channel within the special treatment,there is no effect a small amount of passengers scattered liquid, more at ease. 5. self-diagnosis: automatic fault diagnosis, and give a message, easy to maintain. 6. zoom function: continuous mouse zoom function, more continuous. Unique mouse magnifying glass function, any local details zoom, more accurate. 7. Detection of objects: parcels, small bags, suitcases, bags and other large objects. Applications: 01. Airports, 02. Transport terminals, 03. Buildings, 04. Factories (to find needle in clothing, shoes, bags), 05. Courthouses, 06. Embassies, 07. Military installations, 08. Prisons, 09. Hotels, 10. Schools , 11. Convention centers, 12. Security checkpoints 13. Special events location Technical Parameters: Dimensions: 2040 (length) x920 (width) X1300 (high) mm Channel Size: 650 (W) X500 (H) mm Conveyor speed: 0.22m / s Conveyor max load: 170kg Resolution: diameter 0.07871mm metal wire Spatial resolution: horizontal diameter 1.0mm; vertical diameter 1.0mm Penetration: 10-40mm steel(adjustable) Film safety: Safety for IS01600 film Leakage dose:
Features: 1. One-button shutdown: turn off only need to turn the key, the device automatically safe shutdown, more humane. 2. Emergency stop hierarchical control: press the tight stop button, only the power transmission and ray source part, more secure. 3. Image ultra-clear: the core components of high-density imported modules, higher resolution, to the international level, more clear. 4. Waterproof function: the channel within the special treatment,there is no effect a small amount of passengers scattered liquid, more at ease. 5. self-diagnosis: automatic fault diagnosis, and give a message, easy to maintain. 6. zoom function: continuous mouse zoom function, more continuous. Unique mouse magnifying glass function, any local details zoom, more accurate. Has a specific role in identifying specific explosives. 7. Detection of objects: parcels, large bags, suitcases, bags and other large objects. Applications: 01. Airports, 02. Transport terminals, 03. Buildings, 04. Factories (to find needle in clothing, shoes, bags), 05. Courthouses, 06. Embassies, 07. Military installations, 08. Prisons, 09. Hotels, 10. Schools , 11. Convention centers, 12. Security checkpoints 13. Special events location technical standard Electrical appliances with reference to EN60950 safety standards Radiation is carried out with reference to EN50081-1 Strict implementation of the current X-ray security equipment national standards Fully through the ISO14001: 2004 environmental management system certification Fully through the OHSAS18001: 2007 occupational health and safety management system certification Fully passed ISO9001: 2000 quality management system certification Technical Parameters: Dimensions: 3980 (length) x1130 (width) X1796 (high) mm Channel Size: 800 (W) X650 (H) mm Conveyor speed: 0.22m / s Conveyor max load: 200kg Resolution: diameter 0.07871mm metal wire Spatial resolution: horizontal diameter 1.0mm; vertical diameter 1.0mm Penetration: 10mm ~ 48mm steel plate (can be customized) Film safety: Safety for IS01600 film Leakage dose:
we are bound in offering the present day premium quality exhibit of X - Ray Baggage Scanner. Our determined experts create these machines by utilizing subjective fundamental mat present-day procedures. Before being conveyed at clients' end, the offered reach is stringently checked against differing quality parameters.
XX- line of portable X-ray units is designed to the principle of low cost and high reliability, which is characteristic in convenient to carry, easy to operate, and highly automated. X-ray tube and HT coil are all produced by DANDONG NDT which guarantees system consistency. Weight is further reduced with the use of SF6 insulation. Forced cooling fan guarantee the longevity of X-ray tube, which makes the product suitable for field and highly above work. K03/K05 control unit is microprocessor controlled with module of controlled silicon voltage adjustment and frequency conversion. The functions of fully automatic warm-up program, fault display, over voltage and mis-start protection, the stability and service life are much improved. 655 ¬200mm 15kg
100 mA Mobile x-ray machine. very good image quality. built in stabilizer. works on 220v AC.
Dear friend, I am ali from china lucky film group, the largest medical x ray film and industrial x ray film producing manufacturer in china. As a state company, it shares good reputation around world. China lucky film group founded in 1958 and consists of scientific research, producing and selling. Our medical x ray film includes medical x ray film blue sensitive, medical x ray film green sensitive and medical dry thermal film. We also produce medical thermal printer with convient using and satisfying quality. With good quality, we have already sell to many countries such as pakistan, iran , bangladesh. If interested of our products, pls feel free to contact me, i will give u a competitive price with best quality. If there are any possibility for us to cooperate , to promote the business between us, we can send sample for free . Waiting for your early reply. Best regards, Ali li --------------------------------
9-inch/12-inch/6-inch 20mm/25mm image output high dqe high resolution high contrast high definition high image quality x-ray image intensifier (xrii) for image intensifier tv system (ii tv) and x-ray fluoroscopy x-ray machine, c-arm x-ray machine, industrial inspection x-ray machine More info plz contact: Lina Whatsapp: +86-15653608205 Skype: lina zhang-newheek E-mail: newheeklina@163.Com Web: www.Newheek.Com
We are swiss company buyer x-ray film used and ndt film used Balls
Tube stand (xts-01) Type : floor-to-ceiling rail Distance of longitudinal travel : 2550mm Distance of vertical travel : 1600mm Rotation of x-ray tube : ±180° Lock system : electromagnetic lock by manual Weight : 170kg Ceiling (xce-01, option) Type : ceiling rail Distance of longitudinal travel : 2800mm Distance of vertical travel : 1200mm Rotation of x-ray tube : ±180° Lock system : electromagnetic lock by manual Weight : 130kg Bucky stand (xbs-01, option) Type : vertical travel Distance of vertical travel : 120mm ~ 1780mm X-ray grid : grid ratio of 8:1, 103 line/inch Front plate to film distance : 50mm Weight : 105kg 4way type bucky table (xbt4-01) Type : 4way travel Longitudinal distance of tabletop sliding : 420±5mm Lateral distance of tabletop sliding : 120±5mm Tabletop to floor distance : 665mm X-ray grid : grid ratio of 8:1, 103line/inch Dimensions : 2000l x 750w x 665h (mm) Weight : 150kg 6way type bucky table (xbt6-01, option) Type : 6way travel Drive type : electric motor drive X-ray grid : grid ratio of 8:1, 103line/inch Longitudinal distance of tabletop sliding : 420±5mm Lateral distance of tabletop sliding : 120±5mm Vertical distance of tabletop : 300±5mm Tabletop to floor distance : 689(880)mm Dimensions : 2000l x 750w x 680(880)h (mm) Weight : 170kg High voltage cable (hvc-6/8) Length : 6m/8m Maximum voltage : dc 75kv The number of core line : 3 lines