Cv joint, CV axle, shaft.
Electromagnetic and ultrasonic flowmeters.
Available in sizes from dn 10 to 300 mm (1/2"÷12"); High grade stainless steel, titanium, or tantalum integrated electrodes; Different lining materials available (ptfe or polyurethane); High accuracy and stability of measurement; Flanged or wafer-type connection (wafer-type connection for Dn10, 15 mm); Bidirectional flow measurement (on request); Remote design available (display unit can be placed away from flow tube at 1 km maximum); Batching mode available; Suitable for mounting on polymer pipes; Oiml and iso 9001:2008 certified; Integrability into automatic industrial control systems.
Available in sizes from dn 10 to 300 mm (1/2"÷12"); Flanged connection (wafer-type connection for Dn10, 15 mm); Bidirectional flow measurement (on request); Full-bore meter design eliminates pressure loss in measurement section; No filtering required; Short straight pipe runs required for installation; Protection against unauthorized access; Suitable for mounting on polymer pipes; Oiml and ISO 9001:2008 certified.
Material :catoon 100% Size m and l Colour all black , white Brand , quiksilver, ripcurl, volcom, vans, huf and to much all
Ultrasonic flowmeter, level meter, battery electromagnetic flowmeter, transmitter.
Ultrasonic flowmeter ,electromagnetic flowmeter, open channel flowmeter, water meter, thickness gauge.
Fine flow flow meters by h&l from korea, digital turbine flowmeters, liquid turbine flowmeters, positive displacement flow meter, electromagnetic flowmeters, ultrasonic flowmeters, vortex flowmeters, coriolis mass flowmeters, variable area flowmeters.
1. Non-invasive transducers are easy to install, cost effective, and require no pipe cutting or processing interrupt. 2. Wide liquid temperature range: -35~200. 3. Data logger function. 4. 14 hours battery(rechargeable), back-lit 4 lines display. 5. For commonly used pipe materials and diameters from 20mm to over 6.0m. 6. Wide bi-directional flow range of 0.01 m/s to 12 m/s.
--- It is suitable forpipe sizes ranging from 40 to 4000mm --- For dirty liquids, a certain amount of air bubbles or suspended solids shall be contained --- Excellent low flow rate measurement ability, low to 0.05m/s. --- A wide range of flow measurement, high flow rate can reach 12m/s --- High-temperature transducer is suitable to liquids of -35â?? ~ 200â?? --- Do not need to shut down the pipe flow when installing the transducers --- User-friendly configuration --- 4-20mA, Relay and OCT outputs --- Accuracy: 2.0% Calibrated span
The DOF6000 series DOF6000-P Portable Open Channel Ultrasonic Flow Meter consists of Flow calculator and the Ultraflow QSD 6537 Sensor. The Ultraflow QSD 6537 Sensor DOF6000-P Portable Open Channel Ultrasonic Flow Meter is used to measure water velocity, depth, and conductivity of water flowing in rivers, streams, open channels and pipes. When used with a companion Lanry DOF6000 Calculator, flow rate and total flow can also be calculated. The flow calculator can calculate the cross-sectional area of partially filled pipe, open channel stream or river, for stream or river, with up to 20 coordinate points describing the riverâ??s shape of cross section. It is suitable for various applications.
Ultrasonic flow meter, ultrasonic level meter, level meter, ultrasonic level meter, coating thickness gauge, ultrasonic thickness gauge, hand held ultrasonic flow meter, electromagnetic flow meter, flowmeters.
Turbine Flow Meters which have advantages of simple structure, light weight, high accuracy and easy installation, measure liquid which has no impurities and no chemical corrosive reaction with stainless steel . The measurable liquids include water , diesel and methanol, etc. FINE-FLOW FLOW METERS BY H&L FROM KOREA FEATURES Wide range of liquid measurement High accuracy and excellent repeatability Easy installation and energy saving Easy to read LCD Back light. Specific Gravity Correction 0.01 2.00 Display Accumulated amount reset, accumulated flow display, instantaneous flow rate display, gallon or liter unit change, automatic integration Lamp indication Flow display Battery life 4 5 years Auto on and off
SYSTEM INFORMATION The electromagnetic flow meter HMF 2110 series is the most common and highly accurate flow measurement device that can be universally used in various measurement fields. Since there is no driving part like a propeller, no trouble is caused due to pressure loss, and the durability is excellent In addition, since the installation is simple with the flange type, even a beginner can easily install it through simple training. The sensor measures the flow rate by direct contact with the fluid,, thus a more reliable flow rate value can be obtained, and the reproducibility is also excellent If you are looking for a flowmeter that can be used with confidence, choose the HMF 2110 series without hesitation. â?? KEY FEATURES Quick Start Self diagnostic Easy Maintenance â?? CHARACTERISTICS â?¢ Due to high stability, popular for water flow measurement â?¢ Excellent durability due to no driving part â?¢ Electrode and lining materials are selected for measuring chemical flow â?¢ There is no pressure drop, which reduces electricity costs. â?? SPECIFICATIONS * Sensor installation method : Flange mounting type (Standard: JIS, DIN, ANSI, etc.) * Accuracy : �±0.2% (flow rate 0.1 m/s or more)0.2% (flow rate 0.1 m/s or more) * Max Minimum Flow : 0.05 m/s ~ 10 m/s (Flow rate by diameter) * Measuring pipe caliber : 6 mm ~ 2,000 mm * Measurable fluid : Water, sewage, wastewater, chemicals, etc. (Conductivity of 5�¼S /cm or more) * Power : 110 ~ 220 V AC / 60 Hz * Operating temperature : Sensor (40 ~ 70 â??), Operation: (18 ~ 60 â??) * Screen display contents : LCD Size: LCD Display 100 x 55, 3 Line, 16 Characters, Instantaneous flow rate (4 digit), accumulated flow rate (9 digit), pressure (4 digit) * Flow display unit : Unit: m3, L, etc. / Directions: Forward & Reverse (-) * Electrode : Hastelloy C * Liner: NBR, Hard Rubber, EPDM * Flange : Carbon Steel * Flow measurement frequency : 1.875 ~ 12.5 Hz * Sensor cable length : 100m * Output signal : 4 ~ 20 mA, Integrated pulse active , Passive (Max 10 kHz), Relay pulse (Max Load 24 V DC / 1A) * Communication and memory : RS 232, RS 485 Modbus 128 Mbyte internal memory: date, time, instantaneous flow rate, accumulated flow rate, Pressure memory interval: 5 seconds ~ 24 hours * Protection class : Sensor unit: IP 68 / Operation unit: IP 65 * Self diagnosis function : Alarm display when empty pipe information and self diagnosis error occur For more details on quality Korean flowmeters, please feel free to visit http://www.hnl-global.com/flowmeter and contact us.
[ CHARACTERISTICS ] Accurate heat consumed under heat load is measureable * Display of various information : Heating energy / cooling energy Instantaneous heat and accumulated quantity, temperature , instantaneous flow rate, accumulated flow rate, etc. â?¢ Easy data transfer function through MODBUS RS 485 [ SPECIFICATIONS ] * Display - DC Type : Touch Screen Color Graphic LCD - AC Type : 2 X 20 Characteristic LCD with El Backlight or VFD * Temperature - Operating temperature: 0 ~ 60 â??â?? - Storage temperature: 25 ~ 70 * Power : 85 ~ 264 V AC / 12 V DC * Case dimension : (W) 150 mm X (H) 180 mm X (D) 50 mm * Input - Frequency Range: 0 Hz to 5 kHz / K factor Range: 0.0001 to 50,000.000 (Pulse / Units) - RTD Signal Type: Open Collector, Voltage or Current Pulse * Output - Analog Function: 4 ~ 20 mA calorific output / accuracy: 0.1% - Pulse Output #1 (Energy Total) Output: Open Collector transistor will sink 50 mA max - Pulse Output #2 (Flow Total) Pulse width: 5 ms , 10 ms , 100 ms , 200 ms * Communication - Kinds RS 485 MODBUS - Baud Rate 1200 ~ 19,200 BPS - ID code 4 Multi Point communication, specific address programmable * Display unit - Energy kWh, J , cal , BTU - Volume m3, L * Data logging - Logging interval : Day, hour and second can be set - Logging information : Volume Total, Volume Rate, Energy Total, Energy Rate, Temperature, Date & Time - Internal memory 12 months (Logging interval: 1 minute storage, 1 year storage) For more details on quality Korean flowmeters, please feel free to visit
[ CHARACTERISTICS ] Accurate heat consumed under heat load is measureable * Display of various information : Heating energy / cooling energy Instantaneous heat and accumulated quantity, temperature , instantaneous flow rate, accumulated flow rate, etc. â?¢ Easy data transfer function through MODBUS RS 485 [ SPECIFICATIONS ] * Display - DC Type : Touch Screen Color Graphic LCD - AC Type : 2 X 20 Characteristic LCD with El Backlight or VFD * Temperature - Operating temperature: 0 ~ 60 â??â?? - Storage temperature: 25 ~ 70 * Power : 85 ~ 264 V AC / 12 V DC * Case dimension : (W) 150 mm X (H) 180 mm X (D) 50 mm * Input - Frequency Range: 0 Hz to 5 kHz / K factor Range: 0.0001 to 50,000.000 (Pulse / Units) - RTD Signal Type: Open Collector, Voltage or Current Pulse * Output - Analog Function: 4 ~ 20 mA calorific output / accuracy: 0.1% - Pulse Output #1 (Energy Total) Output: Open Collector transistor will sink 50 mA max - Pulse Output #2 (Flow Total) Pulse width: 5 ms , 10 ms , 100 ms , 200 ms * Communication - Kinds RS 485 MODBUS - Baud Rate 1200 ~ 19,200 BPS - ID code 4 Multi Point communication, specific address programmable * Display unit - Energy kWh, J , cal , BTU - Volume m3, L * Data logging - Logging interval : Day, hour and second can be set - Logging information : Volume Total, Volume Rate, Energy Total, Energy Rate, Temperature, Date & Time - Internal memory 12 months (Logging interval: 1 minute storage, 1 year storage)
[ CHARACTERISTICS ] Accurate heat consumed under heat load is measureable * Display of various information : Heating energy / cooling energy Instantaneous heat and accumulated quantity, temperature , instantaneous flow rate, accumulated flow rate, etc. â?¢ Easy data transfer function through MODBUS RS 485 [ SPECIFICATIONS ] * Display - DC Type : Touch Screen Color Graphic LCD - AC Type : 2 X 20 Characteristic LCD with El Backlight or VFD * Temperature - Operating temperature: 0 ~ 60 â??â?? - Storage temperature: 25 ~ 70 * Power : 85 ~ 264 V AC / 12 V DC * Case dimension : (W) 150 mm X (H) 180 mm X (D) 50 mm * Input - Frequency Range: 0 Hz to 5 kHz / K factor Range: 0.0001 to 50,000.000 (Pulse / Units) - RTD Signal Type: Open Collector, Voltage or Current Pulse * Output - Analog Function: 4 ~ 20 mA calorific output / accuracy: 0.1% - Pulse Output #1 (Energy Total) Output: Open Collector transistor will sink 50 mA max - Pulse Output #2 (Flow Total) Pulse width: 5 ms , 10 ms , 100 ms , 200 ms * Communication - Kinds RS 485 MODBUS - Baud Rate 1200 ~ 19,200 BPS - ID code 4 Multi Point communication, specific address programmable * Display unit - Energy kWh, J , cal , BTU - Volume m3, L * Data logging - Logging interval : Day, hour and second can be set - Logging information : Volume Total, Volume Rate, Energy Total, Energy Rate, Temperature, Date & Time - Internal memory 12 months (Logging interval: 1 minute storage, 1 year storage) For more details on quality Korean flowmeters, please feel free to visit http://www.hnl-global.com/flowmeter and contact us.
[ CHARACTERISTICS ] Various inputs such as flow meters and pressure gauges. Real time communication through Modbus, BlueTooth , etc. 2G Data logging â?¢ Convert MODBUS or RS232 input to HART Item [ SPECIFICATIONS ] * Display 3.5 inch (320 x 240) Touch Screen Color Graphic LCD * Power : 90 ~ 240 V AC (Free Volt) * Output : RS 232 ASC DATA, HART Communication, RS485 MODBUS, 4~20 mA Output(24bit) of Flow Rate, MODBUS TCP/IP Ethernet(LAN), BlueTooth Wireless, 2 GB Memory, Memory Data Download USB Memory, Total Pulse Output(TTL), DC 24 V Power (0.6 A) * Input : RS 232 ASC DATA, HART Communication RS 485 MODBUS Communication 4 ~ 20 mA * Protection class : IP 65 * Piping pressure input 24 V DC pressure gauge drive and display * Size : (W) 150 mm X (H) 180 mm X (D) 50 mm
System Information The electromagnetic flow meter HMF 2110 series is the most common and highly accurate flow measurement device that can be universally used in various measurement fields. Since there is no driving part like a propeller, no trouble is caused due to pressure loss, and the durability is excellent In addition, since the installation is simple with the flange type, even a beginner can easily install it through simple training. The sensor measures the flow rate by direct contact with the fluid,, thus a more reliable flow rate value can be obtained, and the reproducibility is also excellent If you are looking for a flowmeter that can be used with confidence, choose the HMF 2110 series without hesitation. â?? KEY FEATURES Quick Start Self diagnostic Easy Maintenance â?? CHARACTERISTICS â?¢ Due to high stability, popular for water flow measurement â?¢ Excellent durability due to no driving part â?¢ Electrode and lining materials are selected for measuring chemical flow â?¢ There is no pressure drop, which reduces electricity costs. â?? SPECIFICATIONS * Sensor installation method : Flange mounting type (Standard: JIS, DIN, ANSI, etc.) * Accuracy : �±0.2% (flow rate 0.1 m/s or more)0.2% (flow rate 0.1 m/s or more) * Max Minimum Flow : 0.05 m/s ~ 10 m/s (Flow rate by diameter) * Measuring pipe caliber : 6 mm ~ 2,000 mm * Measurable fluid : Water, sewage, wastewater, chemicals, etc. (Conductivity of 5�¼S /cm or more) * Power : 110 ~ 220 V AC / 60 Hz * Operating temperature : Sensor (40 ~ 70 â??), Operation: (18 ~ 60 â??) * Screen display contents : LCD Size: LCD Display 100 x 55, 3 Line, 16 Characters, Instantaneous flow rate (4 digit), accumulated flow rate (9 digit), pressure (4 digit) * Flow display unit : Unit: m3, L, etc. / Directions: Forward & Reverse (-) * Electrode : Hastelloy C * Liner: NBR, Hard Rubber, EPDM * Flange : Carbon Steel * Flow measurement frequency : 1.875 ~ 12.5 Hz * Sensor cable length : 100m * Output signal : 4 ~ 20 mA, Integrated pulse active , Passive (Max 10 kHz), Relay pulse (Max Load 24 V DC / 1A) * Communication and memory : RS 232, RS 485 Modbus 128 Mbyte internal memory: date, time, instantaneous flow rate, accumulated flow rate, Pressure memory interval: 5 seconds ~ 24 hours * Protection class : Sensor unit: IP 68 / Operation unit: IP 65 * Self diagnosis function : Alarm display when empty pipe information and self diagnosis error occur For more details on quality Korean flowmeters, please feel free to visit http://www.hnl-global.com/flowmeter and contact us.
Low maintenance cost and easy installation Long lasting performance: No maintenance and repair for 6 years â?¢ Intelligent information can be output by providing advanced statistical data and diagnostic programs â?¢ Maximum tolerance of Class 1 meter: 1% in convection area ( Q2 â?¤ Q â?¤ Q4) 3 % in small area (Q1 â?¤ Q â?¤ Q2) [ SPECIFICATIONS ] * Measuring caliber 25 mm ~ 1,200 mm * Domestic Approval : 50 mm, 65 mm, 80 mm, 100 mm, 125 mm, 150 mm, 200 mm, 250 mm, 300 mm, 350 mm * Composition : Detection unit: Electronic sensor / Conversion unit: input unit, operation unit, output unit, indicator * Accuracy Full Scale: 0.2% (65 mm ~ 250 mm: 1st grade / 50 mm, 300 mm, 350 mm: 2nd grade) * Max. Measureable Flow Rate : 10 m/s * Display unit and contents : Accumulated flow (m3): 9 digit x 1 (forward, reverse, modification available) Instantaneous flow rate (m3 / h): 4 digits, date, time, alarm (battery life and empty pipe) and data logger * Measurement function : Low flow cut off: 0 ~ 9 of maximum flow * Measurement frequency : Battery Type : 1/5 Hz / AC Type : 6.25 Hz * Max working pressure : 1.0 MPa ~ 1.6 MPa * Input : 4 ~ 20 mA pressure gauge signal (Loop Powered Terminal): AC Type * Output : 1 Instantaneous flow rate (4 to 20 mA) 1 - AC Type 2 accumulated flow (O.C Pulse) - Pulse Load 5 ~ 35 V DC / 50 mA (Common for AC & Battery Type) * Liner : Hard Rubber * Electrode Hastelloy C * Housing/Flange : Carbon Steel * Communication and internal memory : RS 485 MODBUS: AC Type / Internal memory: Date, time, instantaneous flow rate, accumulated flow rate, and pressure Memory interval: 5 seconds ~ 24 hours (1 year storage upon 1 minute interval storage) * Power Battery Type : 3.6 V DC (Life span 7 years) / AC Type : 110 ~ 220 V AC * Temperature : Ambient temperature: 20 ~ 60 / Storage temperature: 30 ~ 70 (humidity up to 95%) * Protection class : Detection unit (IP 68) / Converter (IP 65) [ APPLICATIONS ] Water industry / Wastewater treatment industry For more details on quality Korean flowmeters, please feel free to visit http://www.hnl-global.com/flowmeter and contact us.