Office equipment, aluminium ubc scrap, sea cucumber, rice, water, used cooking oil, home security cameras, used cars, palm oil, home installation materials, frozen beef, a4 copy paper, frozen chicken, soybean oil, used cars, video camera, wood pellet, sunflower oil, wood sawdust, soybean meal, used cloths, euro epal wooden pallets, milk powder, frozen pork, used tires, frozen turkey, laptop, occ waste paper, urea fertilizer, aluminum cylinders, helium gas, balloon gas, disposable helium canister, helium gas cylinders, vegetable oil.Full logistics service loading from any port or airport around europe to the rest of the world.
Cardiovascular intervention products. Including occluder series ASD occluder, VSD occluder, PDA occluder, PTMC balloon (for mitral stenosis), temporary pacing lead, delivery system, pulmonary valvuloplasty balloon catheter, aortic valvu stenosis balloon catheter.
Patent Ductus Arteriosus (PDA) Occlusion Device Effective blockage of blood shunt Varieties of spec. options Special surface treatment, avoids nickel ion precipitation, provides superior bio-compatibility, and long-term safety Effectively blocks blood aorta- pulmonary shunt, guarantees operation efficacy especially for great PDA. Both Straight shape and tapered shape are available; varieties of specifications expand procedural options; Medical catheter; Medical Consumables; Disposable Medical products; l Special surface treatment, avoids nickel ion precipitation, provides superior bio-compatibility and long term safety l Effectively blocks blood aorta-pulmonary shunt, guarantees operation efficacy especially for great PDA l Both Straight shape and tapered shape are available; varieties of specifications expand l procedural options.
Teleflex: Teleflex is a global provider of medical technologies, including products for vascular access, anesthesia, respiratory care, surgical care, and more. They offer a range of vascular products, and the Arrow brand is associated with vascular access and intervention. Rediguard IAB (Intra-Aortic Balloon): Intra-aortic balloon pumps are medical devices used to temporarily support the heart's pumping function and improve coronary artery blood flow. The term "Rediguard" suggests that it may have features related to safety or guarding.
it's common for medical device companies like Medtronic to manufacture guiding catheters used in various interventional procedures, including cardiovascular interventions. Guiding catheters are medical devices used to guide and support the delivery of other interventional devices, such as angioplasty balloons, stents, or embolic protection devices, during procedures like angiography and angioplasty.
I can provide some general information about guiding catheters and Medtronic's involvement in the medical device industry. Guiding Catheter: A guiding catheter is a medical device used in interventional cardiology and radiology procedures. It is designed to guide and support other devices, such as guidewires and balloons, to the target location within the blood vessels. Medtronic: Medtronic is a global healthcare company that produces a wide range of medical devices and technologies. They are involved in various medical specialties, including cardiology, neurology, diabetes, and more.
The EverFlex stent is designed for use in the treatment of peripheral arterial disease (PAD), specifically in the iliac arteries. Key features of the EverFlex Protege stent may include: Self-Expanding Design: The stent is self-expanding, meaning it can open and conform to the shape of the artery without the need for balloon inflation. Nitinol Construction: The stent is typically made of nitinol, a nickel-titanium alloy known for its flexibility and ability to maintain shape memory. Longitudinal Flexibility: The stent is designed to provide longitudinal flexibility, allowing it to adapt to the natural movement of the vessel. Iliac Artery Treatment: The EverFlex Protege stent is specifically indicated for use in the iliac arteries, which are located in the pelvis.
Terumo Runthrough NS PTCA is a medical device designed for use in percutaneous transluminal coronary angioplasty (PTCA) procedures. PTCA is a minimally invasive procedure used to treat coronary artery disease by widening narrowed or blocked coronary arteries. Here are some key points about the Terumo Runthrough NS PTCA: Manufacturer: Terumo Corporation is a Japanese company known for its medical devices and healthcare products. Type: The Runthrough NS PTCA is a guide wire used in PTCA procedures. Guide wires are essential tools that help navigate catheters and other interventional devices through blood vessels during angioplasty. Function: The guide wire assists in guiding and positioning the catheter within the coronary arteries. It helps the interventional cardiologist navigate through the blood vessels and reach the site of the blockage or narrowing. Features: The "NS" in Runthrough NS may refer to "non-support" or "normal support," indicating the level of support provided by the guide wire. The choice of guide wire depends on factors such as the location and severity of the arterial blockage. Usage: The Terumo Runthrough NS PTCA guide wire is specifically designed for use in PTCA procedures to help facilitate the placement of angioplasty balloons and stents.
LATEX CONCENTRATE (HA) TYPE Natural rubber latex concentrate (HA) is a high ammonia centrifuged concentrated latex of the sap of Hevea brasiliensis trees. This general purpose type latex finds its application in a variety of products. APPLICATION HA latex is the most widely used form of concentrate and has the advantage that the only preservative (ammonia) it contains is volatile. Hence it may be used confidently in food applications and for medical goods. HA latex concentrate has wide applications especially in the dipped products like medical or industrial gloves, balloons, condoms, catheters, finger cots, tubing, etc. It is also used as an adhesive for footballs, bandages, in wood lamination and for binding different types of materials. It gives excellent films of high clarity and has good adhesion characteristic. STORAGE Store the product under shelter at temperatures between 10�°C and 35�°C Creaming of latex may occure during storage. It is therefore necessary to stir well the latex before used. As the product is based on natural rubber latex changes in colloidal properties may occur on storage. TYPICAL PROPERTIES Total Solids Content (TSC), % 61.00 min Dry Rubber Content (DRC), % 60.00 min Non Rubber Content (NRC ), % 1.70 max Ammonia Content (on total weight), % 0.65-0.75 pH Value 11.00 max KOH Number 0.70 max Volatile Fatty Acid Number 0.05 max M.S.T. @55% TSC, sec. 650 min Magnesium Content, (on solids), ppm 40 max HANDLING PRECAUTION Before handling, read product information, chemical safety data sheets and container label for safe use, physical and health hazard information. PACKING Available in both bulk and drum.
High quality latex and foil balloons As per customer request
Balloon Our products are made by pvc tarpaulin; the flame retardant meets the british standard (bs5852).The material we use has one of the highest tear resistance ratings in the world: 25kg/250n. For the seams, we use double seams when putting games together. The most important thing is our seams are done using thread that can withstand great force (17kg) before tearing. We supply the air blower with voltage of 110v, 220v, 380v as required. Our air blowers have passed the certificate of ce and ul.
"COLOUR: Bottle green COMPOSITION: 70% cotton, 30% silk CARE: Dry clean Skinny neckties Detachable waist tie"
erulean blue V-neck balloon sleeves buttoned cuffs front zip fastening flared skirt
Both Side PVC Coated 3 layer premium quality 900gsm,UV Protected, Thickness- 0.7mm, Max Pressure 10-15mbar Custom sized End Usage: storage as well transport purposes
Lot of 7 Mini One Balloon Button Low Profile Feeding Device 5 - REF M1-5-1235 (12f x 3.5cm) EXP. 2013-06 2 - REF M1-5-1810 (18f x 1cm) EXP. 2013-05 In original factory packaging & never opened May be non-sterile due to expiration date Not for human consumption. Not an implantable device. Items sold a non-sterile due to expiration of sterility on packaging are sold as-is and may be re-sterilized and used for training or veterinary purposes. "The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. Do not purchase this item unless you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item." DISCLAIMER: Regardless of the origin of the equipment, documentation provided or identification appearing upon the equipment, the equipment described and offered here is in no way certified for, recommended for, or offered for any specific use. The purchaser agrees that the seller shall not be held responsible or liable for any injuries or damages, whether incidental or consequential, associated in any way with the equipment. The purchaser, by purchasing this equipment, indicates their acknowledgment of, and agreement to the terms of this disclaimer. WAIVER LIABILITY AND INDEMNIFICATION AGREEMENT By placing this order with THE SELLER of this sale and accepting the parts, the purchaser agrees that the purchased materials or parts will be used solely at the purchaser's risk and that the purchaser will indemnify and hold THE SELLER, its owners and employees, free and harmless from all loss, liability and damage resulting from claims brought by any regulatory agencies, or by reason of any alleged failure or defect of any parts supplied by THE SELLER.
Boston pt2 guide wire Bosotn promus element™ platinum chromium stent Abbott bmw Merit inflation device Terumo guidewire Pta balloons Cordis Medtronic, Abbott vascular, Boston scientific, Terumo, St. Jude medical, Vascular concept, Arrow, Asahi intecc, B barun, Bard, Nipro, Fresenius, Bexter, Introducer femoral sheath Radial sheath Ptfe coated guide wire Diagnostic catheter Stablizer / stablizer+kit Emerland roser heavy duty 0.035x150/180 cm Empira ptca ballon /nc Shinboi / shinboi plus Atw Tiger catheter Radifocus guidewire 0.032 / 0.035 x 150 / 260 cm Micro catheter progreat Guiding catheter Ptca guide wires ( gross it, whisper ) Ptca guide wires ( bmw. Pilot) Floppy Ptca guide wires----avail in bulk ( 0.014 / 0.36mm x 185/190 cm ) Temporary pacing lead Hydrophilic guide wires Hydrophilic sheaths Hydrophilic/tiger catheters Ptca balloon catheters Ptca stent Drug eluted stents Ptmc balloon catheter Tr ra band Iabp balloon catheter Control syringe High pressure tubing Manifold 2 port Manifold 3 port Introducer needle Angio kit Ptca kit Introducer needle pediatric Y-shape introducer needle Inflation device Inflation device with kit Guidewire ptfe coated 150 cm (.18, .21, .25, .28) Guidewire ptfe coated 150 cm (.32, .35., .38) Guidewire ptfe coated 185/190 cm (.14, .35, .38)-bulk only Guidewire ptfe coated 260 cm (.18, .21, .25, .28) Guidewire ptfe coated 260 cm (.32, .35, .38) Ptca y conncetor Ptca y connector with kit Hand control pencil Presusre monitoring line Radial artery band (r a band) Intorducer sheath Angiography catheter Guiding catheter Emblactomy catheter Rinato Froute flex Fileder Fileder fc Miracle 3.0/ 3.5/4.5/6.0/12 Conquest / conquest pro / conquest pro 20 Grand slam Asahi sion blue Micro catheter Thrombuster Boston maverick
Size: length 2.9cm x width 1.1cm Blinking or non blinking LED balloon light can be used for following points: 1. Light up your balloons as balloon lights. 2. Decorating your flowers 3. Light up your swimming pool 4. Light up your vase 5. Light up your fish case 5. Light up your bathtub 6. Use as a flashlights 7. Light up your yard 8. Light up any item you want to make your life fun. 1pc/opp bag 3.5g/pc 3000pcs/carton.
Balloon Molly
Led balloons, 24 hour glow time and is available in 5 pc bags. Blue,White, red, green and yellow . Led Plush Glow Dogs 50 cm $15, 80 cm $25. Led Umberella $22