DP4 series digital panel meter: feature: 1.Display:-19999-----+19999; 2. with track function and voltage/ampere range transfer free setting; 3.with RS485 communication (be ordered); 4.with 4--20mA current analog output; 5. with Hi/Lo thumb switch setting; 6. size:48H*96W; 7. Accuracy: 0.1%--0.2% FS; 8.Range: AV/DV: 0.2V/2V/20(10)V/200(100)V/600V; AA/DA: 2mA/20/200mA/2A/10/20/30/40 /50A/100/200/300/400/500/1000/2000A. Product dimension: 48*96mm one product in one standard paper box, weight:350g/pcs.
FU2200A digital Ethernet power meter with data logger is a three-phase multifunction power and energy meter manufactured by GFUVE. It provides excellent value for monitoring power and energy management systems. It may be used as data gathering devices for intelligent power distribution or plant automation systems. All monitored data is available via a standard digital RS485 communication port, which is based on the Modbus RTU protocol. FU2200A Ethernet power meter has the PC software and the data logger function, which can set by end users from 1min to 60min intervals to record. You can read the data through a PC. Also, you can share the data in the Internet LAN. By the way, it can measure the harmonics. Back of power meter FU2200A with Ethernet port.
CP-PF series meter using on single phase or 3- phase system measure cos Ï?i, has a moving coil meter movement that shows by an electronic circuit the phase shift between voltage and current (cos. Ï?). Scales are available between 90° and 360° phase shift, as well as capacitive and inductive. FEATURES M4 screw connections with clamps make this easier Clamping the connecting wires. Housing use matiral match UL94V-0 standard All fastenings suitable for shaking and shock resistance. Accept special customization requirements
BJ-192/193 series especially developed for indication and supervision of the three-phase circuit, replaces an analogical display meter, reducing installation manpower and optimizing the used one of spaces in the panel. Ideal for protection of single phase and three-phase networks, it is monitored and generally to own alarm superior and inferior. Protection of the parameters of programming by password. Features ·Class 0.5(192 series)/0.5S(193 series) electrical parameter measurement ·Current measuring .../5 or .../1 A ·Measurement function cover: Current, Voltage, total three-phase power, power factor, frequency ·RS-485 MODBUS-RTU Communications ·Expandable input / output modules (1 modules) ·ITF Technology: galvanic insulation protection inputs outputs ·Large character LED Screen display ·Optional various install sizes Application ·Metering of distribution feeders, transformers, generators, capacitor banks and motors. ·Medium and low voltage systems.
CP-W and CP-var analog power meter consists of a moving coil meter with installed transducers which measures the active / reactive power in a sinusoildal or not sinusoidal current circuit and which transformes it into an analogue signal. This is then passed to the moving coil movement. FEATURES M4 screw connections with clamps make this easier Clamping the connecting wires. Housing use matiral match UL94V-0 standard All fastenings suitable for shaking and shock resistance. Accept special customization requirements MODELS Ordering info Measurement range (Include CT/VT ratio) Overload (Amp/voltage reading) Accuracy class Operation frequency Marine use or not
Power supply (AC/DC) AC 85-265V/DC 85-330V Power consumption:
*Power supply:AC220V or AC/DC 80V~260V *3-phase 3-wire, 3-phase 4-wire *Voltage rated value:AC100V400V accuracy:0.5 *Current rated value:AC1A/AC5A accuracy:0.5 *Frequency:40-60Hz Function module: *Standard configuration: 1 way RS-485 communication, Modbus-RTU protocol *Power pulse output: 1 way active power, 1 way reactive power pulse output ======================================= Additional functions: *Discrete output(DO):Support 4 - way relay output, capacity:AC250V/5A, DC30V/5A; *Discrete input(DI):Support 4 - way dry point input; *Analog output:Support 4 way analog output, 4~20mA/0~20mA or 0~5/0~10V
To meet the diversified applications of electrical industry, we are engaged in manufacturing and exporting extensive range of analog meter that are configured with advanced technologies. These analog volt meter excellent performance and expansive industrial applications. These voltmeters are available in different shapes and sizes as per the specification and requirements of the clients. They are used for monitoring and calculating high voltage induced by energizer. Analog volt meter gives accurate readings · long service life 150 set per cartton
Current : 99t1-a sq48-a Voltage : 99t1-v sq48-v Frequency : 99t1-hz sq48-hz Power : 99t1-kw sq48-kw Power factor : 99t1-cos sq48-cos
Meter Box, Meter Cabinet, Panel Box For Single Phase And Three Phase Electricity Meter
I. The Brief Introduction. Panel mount digital energy meter LCD multi-function power meter with power pulse output RS485, DI DO analog output function. Panel mount digital energy meter LCD multi-function power meter with power pulse output RS485, DI DO analog output function is one multifunctional instrument with measurement, display, digital communication and input, output, etc function. It can measure multiple electrical parameters such as current, voltage, power, electric energy, frequency and power factor in the power grid. With power pulse output and RS485 communication function. With large screen LCD screen. There are a variety of extension functions to choose from. Four-way discrete input; Four-way discrete output; Four-way variable output. LCD multifunctional power meter has high performance-price ratio, can replace traditional multiple measuring instruments, convenient field wiring, and improve system reliability. Modbus communication protocol for easy computer programming or reading data. Widely used in a variety of power distribution, metering and various power collection, transmission systems. II.Functional module, LCD multi-function power meter with power pulse output and RS485 communication function, large screen LCD display meter *Communication interface: standard 1 way RS-485 communication, Modbus-RTU protocol, baud rate: 9600bps. *Discrete output: support 4 way relay outputs, capacity: AC250V/5A, DC30V/5A. *Discrete input: support 4 way dry node inputs. *Transmission output: support 4 way simulation outputs, 4-20mA/0-20mA or 0-5/0-10V. *Power pulse output, 1 way active energy, 1 way reactive energy pulse output, constant: 3200imp.
BLUE JAY DC energy meters with a DC signal conditioner board combine high accuracy with high read rate and a wide range of isolated output options for computer interface and control. DC energy meter operation provides four full-scale current ranges 5.00A with 25mA resolution. The 5.000 A range measures can connect current shunt to expand the measure range. Voltage ranges from 5V with 25 mV resolution to 600.0 V with 5V resolution. All current and voltage ranges are factory calibrated, without recalibrating the meter. External current shunts are fully supported. Scaling is 75 mV - 5A, more than 5A will set transformer ratio from the front panel of the meter. The scalable readout is four full digits up to 9,999 counts. Shunt is remotely located for direct sensing. This allows the current carrying wires to take a more direct path to the large current and alleviates the need to route them through the meter case.
BLUE JAY DC energy meters with a DC signal conditioner board combine high accuracy with high read rate and a wide range of isolated output options for computer interface and control. DC energy meter operation provides four full-scale current ranges 5.00A with 25mA resolution. The 5.000 A range measures can connect current shunt to expand the measure range. Voltage ranges from 5V with 25 mV resolution to 600.0 V with 5V resolution. All current and voltage ranges are factory calibrated, without recalibrating the meter. External current shunts are fully supported. Scaling is 75 mV - 5A, more than 5A will set transformer ratio from the front panel of the meter. The scalable readout is four full digits up to 9,999 counts. Shunt is remotely located for direct sensing. This allows the current carrying wires to take a more direct path to the large current and alleviates the need to route them through the meter case.
Features: 1. Modern design 2. High accuracy ±2mm 3. Lcd with backlight 4. Battery indicator 5. Water proof ip54 6. Auto power off Specifications: Measuring range:0.05m~40m Accuracy:±2mm Laser type:620nm~690nm/
Our most popular of the Topcon Brand luxmeters, single button operation, operates from a single 9V battery and utilises a silicon based detector
one-button start Smart reminder HD display
We have available following Ships spareparts for Sale: Product-Control panel Maker-Leslie Model-PMC-1 Sr no-1976 Made in USA
Ld 9100 series temperature and humidity data logger has internal high-precision sensors for temperature or temperature and humidity measurements. The device stores maximum 65000 measuring data automatically with selectable intervals from 1s to 24h. It is equipped with intelligent data analysis and management software for data download, graph checking and analysis, ect. This device is designed with lcd, led indicators and buttons. Realtime readings and alarm information can be displayed on lcd. The two leds flash in red, green and yellow colors to indicate the status of working and alarming. It’s easy to operate with the two buttons to browse realtime readings, start & stop logging and power on or off, etc. Specifications: Model no.: Ld 9101, ld 9102, ld 9103, ld 9104 TemperatureRange-30~80?(-22~176?) Accuracy±0.5? Resolution0.1?(0.2?) Humidity range --0~100%rh Accuracy-±3.2%rh±2.2%rh±2.2%rh Resolution0.1%rh Data port Usb Waterproof levelIp65 Display Lcd Sampling rate1 second ~24 hours selectable Records 65000 data SoftwareStandard, compatible with windows/vista?windows2000/2003?windows7?8?10 systems Power supplyBattery type1*cr2450 3v Dimension92mm*35mm*20mm Weight Approx. 60g
CP-M maximun demand consists of 2 bimetallic spirals which are installed working one against each other. Maximun demand indicators are especially suited for the supervision of thermal load of cables and transformers. The instrument has a sealable resetting knob with which the red drag indicator can be resetted on the position of the meter's movement pointer (Do not turn lower!). Thermal time delay 15 min. FEATURES M4 screw connections with clamps make this easier Clamping the connecting wires. Housing use matiral match UL94V-0 standard All fastenings suitable for shaking and shock resistance. Accept special customization requirements
CP-W and CP-var analog power meter consists of a moving coil meter with installed transducers which measures the active / reactive power in a sinusoildal or not sinusoidal current circuit and which transformes it into an analogue signal. This is then passed to the moving coil movement. FEATURES M4 screw connections with clamps make this easier Clamping the connecting wires. Housing use matiral match UL94V-0 standard All fastenings suitable for shaking and shock resistance. Accept special customization requirements