EAC 650 Engine: CUMMNS Engine Model : KTAA19-G6 Stand By kVA: 650 Stand By kW : 520 Prime kVA: 590 Prime kW : 472 Rated Current : 849 Engine - CUMMNS heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed Alternat - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis â?? ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine CUMMNS Engine Model KTAA19-G6 Number of Cylinders 6 Inline Injection System Direct Compression Ratio 13.0:1 Bore 159 Strok 159 Displacement Lt 19 Air Intake Turbocharged, Aftercooled Speed (RPM) 1500 Oil Capacity Lt 38 Standby Power kw / Hp 570 / 770 Prime Power Hp 518 / 700 Fuel Type Diesel Governor System Electronic Cooling System Water Cooling Coolant Capacity Lt 75 Fuel Consumption (lt / h) Lt Full Load 140 Lt %75 LOAD 104,9 Lt %50 LOAD 74,5 Frequency Hz Power kVA 550 Voltage V 230 / 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation 1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 5190 Weight (Open) Kg 4510 Width (Silent) Mm 1900 Length (Silent) Mm 4800 Height (Silent) Mm 2400 Fuel Tank Capacity Lt 1450 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnt permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAC 550 Engine: CUMMNS Engine Model : KTA19-G3A Stand By kVA: 550 Stand By kW : 440 Prime kVA: 500 Prime kW : 400 Rated Current : 720 Engine - CUMMNS heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed Alternat - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis â?? ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine CUMMNS Engine Model KTA19-G3A Number of Cylinders 6 Inline Injection System Direct Compression Ratio 13.9:1 Bore 159 Strok 159 Displacement L 19 Air Intake Turbocharged & Intercooled Speed (RPM) 1500 Oil Capacity L 38 Standby Power kw / Hp 504 / 675 Prime Power kw / Hp 448 / 600 Fuel Type Euro Diesel Governor System Electronic Cooling System Water Cooling Coolant Capacity L 75 Fuel Consumption (lt / h) L Full Load 107 L %75 LOAD 82,3 L %50 LOAD 56,4 Frequency Hz Power kVA 550 Voltage V 230 / 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation 1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 5085 Weight (Open) Kg 4410 Width (Silent) Mm 1900 Length (Silent) Mm 4800 Height (Silent) Mm 2400 Fuel Tank Capacity L 1450 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnt permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAC 220 Engine: CUMM NS Engine Model : 6CTAA8.3-G2 Stand By kVA: 220 Stand By kW : 176 Prime kVA: 200 Prime kW : 160 Rated Current : 288 Engine - CUMM NS heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed Alternat - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine CUMMNS Engine Model 6CTAA8.3-G2 Number of Cylinders 6 Inline Injection System Direct Compression Ratio 18.0:1 Bore 114 Strok 135 Displacement L 8,3 Air Intake Turbocharged Air Aftercooled Speed (RPM) 1500 Oil Capacity L 23,8 Standby Power kw / Hp 203 / 272 Prime Power kw / Hp 183 / 245 Fuel Type Euro Diesel Governor System Electronic Cooling System Water Cooling Coolant Capacity L 12,3 Fuel Consumption (lt / h) L Full Load 45 L %75 LOAD 34 L %50 LOAD 23 Frequency Hz Power kVA 220 Voltage V 230 / 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation 1 Insulation Class H Protection Standard IP22 - IP23 Power Factor 0,8 Weight (Silent) Kg 2190 Weight (Open) Kg 1850 Width (Silent) Mm 1200 Length (Silent) Mm 3500 Height (Silent) Mm 1850 Fuel Tank Capacity L 360 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
Characteristic of generator set 1.The design manufacture and test of the engine unit fully comply with national standard GB/T282097; 2.Take unified charge of the design, manufacture and test before delivery of the generator set; 3.Equipped with PERKINS engine ,with advanced technology ,reliable performance and long service life; 4.The excitation system of the generator can make the generator set to bear any twinkling loading and can get restored quickly from frequency fluctuation; 5.The low reactance design of the generator has made extremely low wave form distortion under non-linear load ,and has good motor starting ability; 6.PERKINS Corporation provides quality assurance to all series of its products; 7.CPERKINS Corporation has established a professional service network all over the country ,and provides 24 hours after sale service and supply of parts for clients.
Genset model: hhp100 Rating power:80kw/100kva Stand-by power: 88kw/110kva Dimension: soundproof type-3200x1130x1650mm Fuel tank capacity(skid base fuel tank): Soundproof type-260l Engine:perkins Model:1006tg2a Governor type: electronic Speed: 1500rpm rated power: 102kw Cylinder number and config.: inline, 6 Displacement: 5.99l Aspiration: turbocharged Cooling system: water cooled Lub.Oil capacity: 16.1l Alternator: stamford Model:uci274fs1 rating power: 80kw Power factor: 0.8 Number of bearing: single Voltage: 400/230v Voltage regulation: +/-1% Frequency: 50hz Insulation class:h Protection: ip22 Excitation system: brussless, avr Connection type: 3 phases, 4 wires, "y" type Dimension: 3200x1130x1650mm Weight:2100kgs
EAP 220 Engine: Engine Model : 1106A-70TAG4 Stand By kVA: 220 Stand By kW : 176 Prime kVA: 200 Prime kW : 160 Rated Current : 288 Engine heavy duty diesel engine 12V starter and charge alternator Replaceable air, fuel and oil filters Mechanical governor control Tropical type radiator Flexible fuel hose Oil drain valve and extension hose Industrial type silencer and steel compensator Maintenance-free starter battery Water jacket heater 1500 rpm engine speed Alternat - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis â?? ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine Engine Model 1106A-70TAG4 Number of Cylinders 6 Inline Injection System Direct Compression Ratio 16:01 Bore 105 Strok 135 Displacement Lt 7,01 Air Intake Turbocharged and air charge cooled Speed (RPM) 1500 Oil Capacity Lt 18 Standby Power kw / Hp 196.3 / 265 Prime Power Hp 178.9 / 242 Fuel Type Euro Diesel Governor System Electronic Cooling System Water Cooling Coolant Capacity Lt 22 Fuel Consumption (lt / h) Lt Full Load 45,8 Lt %75 LOAD 34,7 Lt %50 LOAD 23,1 Frequency Hz Power kVA 200 Voltage V 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation 1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 DIMENSIONS Weight (Silent) Kg 2270 Weight (Open) Kg 1940 Width (Silent) Mm 1200 Length (Silent) Mm 3500 Height (Silent) Mm 1850 Fuel Tank Capacity Lt 360 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAP 200 Engine Model : 1106A-70TAG3 Stand By kVA: 200 Stand By kW : 160 Prime kVA: 182 Prime kW : 145 Rated Current : 262 Engine heavy duty diesel engine 12V starter and charge alternator Replaceable air, fuel and oil filters Mechanical governor control Tropical type radiator Flexible fuel hose Oil drain valve and extension hose Industrial type silencer and steel compensator Maintenance-free starter battery Water jacket heater 1500 rpm engine speed Alternat IP 21-23 Protection Standard H Insulation Class 50 Hz Frequency 4 pole brushless synchronous type alternator Automatic Voltage Regulator (AVR) 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis Convenient design for easy lifting and carrying High standard sound proof canopy design Modular design with easily removable nuts - bolts Lockable doors Transparent window for watching Control Panel Electrostatic powder painted, providing protection against harsh weather conditions Emergency STOP button Fuel tank inside the chassis Anti-vibration wedges (engine - chassis and chassis ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine Model 1106A-70TAG3 Number of Cylinders 6 Inline Injection System Direct Compression Ratio 16:01 Bore 105 Strok 135 Displacement Lt 7,01 Air Intake Turbocharged and air charge cooled Speed (RPM) 1500 Oil Capacity Lt 16,5 Standby Power kw / Hp 180.2 / 243,5 Prime Power Hp 162.7 / 220 Fuel Type Euro Diesel Governor System Mechanical Cooling System Water Cooling Coolant Capacity Lt 22 Fuel Consumption (lt / h) Lt Full Load 41,5 Lt %75 LOAD 31,8 Lt %50 LOAD 20,2 Frequency Hz Power kVA 200 Voltage V 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation 1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 2190 Weight (Open) Kg 1850 Width (Silent) Mm 1200 Length (Silent) Mm 3500 Height (Silent) Mm 1850 Fuel Tank Capacity Lt 360 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAP 33 Engine: PERKNS Engine Model : 1103A-33G Stand By kVA: 33 Stand By kW : 26,4 Prime kVA: 30 Prime kW : 24 Rated Current : 43,2 Engine heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed Alternat - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis â?? ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine PERKNS Engine Model 1103A-33G Number of Cylinders 3 Inline Injection System Direct Compression Ratio 19.25:1 Bore 105 Strok 127 Displacement Lt 3,3 Air Intake Naturally Aspirated Speed (RPM) 1500 Oil Capacity Lt 8,3 Standby Power kw / Hp 30,4 / 41 Prime Power Hp 27,7 / 37,3 Fuel Type Euro Diesel Governor System Mechanical Cooling System Water Cooling Coolant Capacity Lt 8 Fuel Consumption (lt / h) Lt Full Load 7,2 Lt %75 LOAD 5,6 Lt %50 LOAD 4 Frequency Hz Power kVA 33 Voltage V 230 / 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation 1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 980 Weight (Open) Kg 825 Width (Silent) Mm 900 Length (Silent) Mm 2200 Height (Silent) Mm 1350 Fuel Tank Capacity Lt 135 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EA Genset supplies Perkins engine diesel generators sizes from 10 kVA to 2500 kVA Variety of Fuel Types
Diesel Generator Perkins Unused 1350 kva Silent type 50hz UK manufacturing The price for now: 80k
3 phase DC power 1250 kVA (1000 kW),emergency 1375 kVA (1100 kW). Silenced, 1500 rpm.Diesel engine Perkins 12 cyl. 45.842 ci.
PERKINS Diesel Generator Set 75GF Diesel Generator Set Dat Set Type: XG-75GF Standby Output: 75KW/93.75KVA Prime Output: 68KW/85KVA Rated Current: 122(A) Rated Frequency: 50(Hz) Start-up time: 5ï½?6(s) Power Factor: 0.8(Lag) Rated Voltage: 400/230(V) Standard Features 1. Engine: PERKINS 1104C-44TAG1 2. Radiator 50â?? max 3. Fans are driven by belt, with safety guard 4. 24V charge alternator 5. Dry type air filter, fuel filter, oil filter 6. Alternator: single bearing alternator 7. IP23, insulation class H/H 8. Main line circuit breaker 9. Standard control panel 10. Absorber 11. Muffler 12. User manual
Perkins diesel generator, diesel generator set, power generator, power generator set, diesel generating set, diesel genset, soundproof generator, silent generator, diesel generator with canopy, diesel generator with enclosure. Composed of Perkins (UK) diesel engine and Stamford alternator Our Perkins generating set (rated power from30kva to 2000kva) is equipped with : 1. Brand New Perkins Engine 2. Brushless Alternator (Leroy Somer, Marathon or Stamford) 3. Voltage output: 400/230V (50Hz), 3Ph, 50Hz, 1500Rpm, 0.8PF, IP23. 4. Radiator 40 Deg C. ambient Temperature mounted on skid. 5. Control panel: Tide2.0controlling panel (AMF built-in) 6. Safety functions for: - High water temperature - Low oil pressure - Over speed 7. 3 poles MCCB with trip doll and MCCB box 8. Rubber mounting for Engine and Alternator 9. 24 V Battery (maintenance free) with Battery Cables and Rack 10. Industrial Silencer with Flexible Bellows and Flanges (loose supply for non-bonnet type) 11. External Fuel tank with Fuel Gauge 12. Output terminal for load cable 13. Output sockets 14. Standard Tool Kit 15. Operation/maintenance Book and parts book (in English) 16. Load Test Certificate Nude packing
Technical Data Sheet Of Accoset-50 ALUMINA MORTAR (Test Certificate) General Properties A. Max service temperature - 1500 oC B. Maximum grain size - 0 - 1.5 mm C. Water required for mixing - 22 - 30% D. Setting - Airsetting E. Sintering Temp - 1550 oC Chemical Properties A. Al2O3 - 50.00% B. SiO2 - 31.00% c. Fe2O3 - 5.00% D. LOI - 7.00% Physical Properties A. Dry Density - kg / m3 B. CCS - 17 kg / cm2 after drying at 110C / 24 hr C. MOR - 20 kg / cm2 at 110 oC/ 24 hr 18 kg/cm2 at 800 C/ 3 hr Thermal Properties - A. Refractoriness ( Orton / C) - 31.5 orton cone/1699 oC Packaging - 25 - 50 kg bags Storage Life - 12 months Delivery State - Dry
EAC 1000 Engine: CUMMINS Engine Model : KTA38-G2A Stand By kVA: 1000 Stand By kW : 800 Prime kVA: 909 Prime kW : 727 Rated Current : 1308 Engine - CUMMINS heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed Alternat�¶r - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis â?? ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine CUMM�°NS Engine Model KTA38-G2A Number of Cylinders 12 - V TYPE Injection System Direct Compression Ratio 14.5:1 Bore 159 Strok 159 Displacement Lt 38 Air Intake Turbocharged, Aftercooled Speed (RPM) 1500 Oil Capacity Lt 135 Standby Power kw / Hp 895 / 1199 Prime Power Hp 813 / 1089 Fuel Type Euro Diesel Governor System Electronic Cooling System Water Cooling Coolant Capacity Lt 350 Fuel Consumption (lt / h) Lt Full Load 202,3 Lt %75 LOAD 153,7 Lt %50 LOAD 103,1 Frequency Hz Power kVA 825 Voltage V 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation �±1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 9350 Weight (Open) Kg 8200 Width (Silent) Mm 2200 Length (Silent) Mm 6200 Height (Silent) Mm 2800 Fuel Tank Capacity Lt 1750 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAC 890 Engine: CUMMINS Engine Model : KTA38-G2B Stand By kVA: 890 Stand By kW : 712 Prime kVA: 809 Prime kW : 647 Rated Current : 1165 Engine - CUMMINS heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed Alternator - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine CUMM�°NS Engine Model KTA38-G2B Number of Cylinders 12 - V TYPE Injection System Direct Compression Ratio 14.5:1 Bore 159 Strok 159 Displacement Lt 38 Air Intake Turbocharged, Aftercooled Speed (RPM) 1500 Oil Capacity Lt 135 Standby Power kw / Hp 789 / 1057 Prime Power Hp 711 / 953 Fuel Type Euro Diesel Governor System Electronic Cooling System Water Cooling Coolant Capacity Lt 350 Fuel Consumption (lt / h) Lt Full Load 176,9 Lt %75 LOAD 133,3 Lt %50 LOAD 91,3 Frequency Hz Power kVA 825 Voltage V 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation ±1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 9300 Weight (Open) Kg 8150 Width (Silent) Mm 2200 Length (Silent) Mm 6200 Height (Silent) Mm 2800 Fuel Tank Capacity Lt 1750 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAC 825 Engine: CUMM�°NS Engine Model : KTA38-G2 Stand By kVA: 825 Stand By kW : 660 Prime kVA: 750 Prime kW : 600 Rated Current : 1080 Engine - CUMMINS heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed Alternat�¶r - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis â?? ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine CUMM�°NS Engine Model KTA38-G2 Number of Cylinders 12 - V TYPE Injection System Direct Compression Ratio 14.5:1 Bore 159 Strok 159 Displacement Lt 38 Air Intake Turbocharged, Aftercooled Speed (RPM) 1500 Oil Capacity Lt 135 Standby Power kw / Hp 731 / 980 Prime Power Hp 664 / 890 Fuel Type Euro Diesel Governor System Electronic Cooling System Water Cooling Coolant Capacity Lt 350 Fuel Consumption (lt / h) Lt Full Load 167 Lt %75 LOAD 128 Lt %50 LOAD 90 Frequency Hz Power kVA 825 Voltage V 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation ±1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 9250 Weight (Open) Kg 8100 Width (Silent) Mm 2200 Length (Silent) Mm 6200 Height (Silent) Mm 2800 Fuel Tank Capacity Lt 1750 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnot permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAC 790 Engine: CUMMINS Engine Model : KTA38-G1 Stand By kVA: 790 Stand By kW : 632 Prime kVA: 718 Prime kW : 574 Rated Current : 1033 Engine - CUMM�°NS heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed Alternat�¶r - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis â?? ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine CUMM�°NS Engine Model KTA38-G1 Number of Cylinders 12 - V TYPE Injection System Direct Compression Ratio 14.5:1 Bore 159 Strok 159 Displacement Lt 19 Air Intake Turbocharged, Aftercooled Speed (RPM) 1500 Oil Capacity Lt 135 Standby Power kw / Hp 701 / 953 Prime Power Hp 634 / 862 Fuel Type Euro Diesel Governor System Electronic Cooling System Water Cooling Coolant Capacity Lt 350 Fuel Consumption (lt / h) Lt Full Load 158 Lt %75 LOAD 122 Lt %50 LOAD 86 Frequency Hz Power kVA 550 Voltage V 230 / 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation �±1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 9200 Weight (Open) Kg 8050 Width (Silent) Mm 2200 Length (Silent) Mm 6200 Height (Silent) Mm 2800 Fuel Tank Capacity Lt 1750 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAC 495 Engine: CUMMINS Engine Model : QSZ13-G3 Stand By kVA: 495 Stand By kW : 396 Prime kVA: 450 Prime kW : 360 Rated Current : 648 Engine - CUMMINS heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed Alternator - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis â?? ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine CUMMINS Engine Model QSZ13-G3 Number of Cylinders 6 Inline Injection System Direct Compression Ratio 17:01 Bore 130 Strok 163 Displacement L 13 Air Intake Turbocharged,Air-Air Cooled Speed (RPM) 1500 Oil Capacity L 40 Standby Power kw / Hp 470 /629 Prime Power kw / Hp 450 /603 Fuel Type Euro Diesel Governor System Electronic Cooling System Water Cooling Coolant Capacity L 60 Fuel Consumption (lt / h) L Full Load 101 L %75 LOAD 74,2 L %50 LOAD 49 Frequency Hz Power kVA 385 Voltage V 230 / 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation ±1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 4100 Weight (Open) Kg 3625 Width (Silent) Mm 1600 Length (Silent) Mm 4500 Height (Silent) Mm 2400 Fuel Tank Capacity L 650 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAC 440 Engine: CUMMINS Engine Model : NTAA855-G7A Stand By kVA: 440 Stand By kW : 352 Prime kVA: 400 Prime kW : 320 Rated Current : 576 Engine - CUMM�°NS heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed Alternat�¶r - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis â?? ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine CUMM�°NS Engine Model NTAA855-G7A Number of Cylinders 6 Inline Injection System Direct Compression Ratio 14.0:1 Bore 140 Strok 152 Displacement L 14 Air Intake Turbocharged,Air-Air Cooled Speed (RPM) 1500 Oil Capacity L 38,6 Standby Power kw / Hp 407 / 545 Prime Power kw / Hp 370/ 500 Fuel Type Euro Diesel Governor System Electronic Cooling System Water Cooling Coolant Capacity L 60 Fuel Consumption (lt / h) L Full Load 89,2 L %75 LOAD 67,8 L %50 LOAD 47,5 Frequency Hz Power kVA 385 Voltage V 230 / 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation �±1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 3765 Weight (Open) Kg 3290 Width (Silent) Mm 1600 Length (Silent) Mm 4500 Height (Silent) Mm 2400 Fuel Tank Capacity L 650 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.