Technical parameters Standards IEC60044-1; IEC 61869-2; NTC 2205; ANSI C57.13; GB1208-2006 Rated primary current 100-1500A Rated load â?¤10VA Rated frequency 50Hz or 60Hz Rated secondary current 5A or 1A Rated short-time thermal current 40kA, 1S Rated continuous thermal current 120%I1n Secondary winding power-frequency voltage 3kV, 1min Instrument security factor FS10 Mechanical parameters Dimensions (WDH) (mm) 80x110x50 Weight (kg) 2.1 Operating conditions Operating temperature -35C to +55C Daily average temp
FEATURES Most cost-effective Faster installation Safe and easy installations High accuracy 0.5 Holding wire diameter: 32mm Ratio ranging from 60/1A to 600/5A CE, UL PARAMETERS Technical parameters Standards IEC/EN60044-1 & IEC61010-1 & IEC61869-2&ANSI C57.13 Ratio 400: 5 or 200:5 , customized Nominal input current Primary current 100A/150A/200A/300A/400A/500A/600A Overload withstand 1.2 times rated current continuously Accuracy 0.2%, 0.5 %, 1%/60Hz System Voltage 720V(0.72kV) Output signal 1A or 5A 333mV AC or 100mV-2V optional Burden 2.5VA Frequency range 40 Hz-500 Hz Dielectric strength 3KV 50Hz/60Hz at 1 minute Output Standard 2.5 meter cable Max. jaw opening 32 mm Mechanical parameters Dimensions (DH) (mm) 110mm130mm 41mm Weight(g) 700 Operating conditions Operating temperature -25 C to +55 C Relative Humidity 0-85% non-condensing Altitude
Standards IEC60044-1; IEC 61869-2; ANSI C57.13; NTC 2205; GB1208-2006 Rated primary current 300-600A Rated load 10VA Rated frequency 50Hz or 60Hz Rated secondary current 5A or 1A Rated short-time thermal current 40kA, 1S Rated continuous thermal current 120%I1n Secondary winding power-frequency voltage 3kV, 1min Instrument security factor FS 10 Mechanical parameters Dimensions (WDH) (mm) 50x110x32 Weight (kg) 1 Operating conditions Operating temperature -35C to +55C Daily average temp
Technical parameters Standards IEC60044-1; IEC 61869-2; ANSI C57.13; NTC 2205; GB1208-2006 Rated primary current 20-600A Rated load 25VA Rated frequency 50Hz or 60Hz Rated secondary current 5A or 1A Rated short-time thermal current 40kA, 1S Rated continuous thermal current 120%I1n Secondary winding power-frequency voltage 3kV, 1min Instrument security factor FSâ?¤10 Mechanical parameters Dimensions (WDH) (mm) 50x110x105 Weight (kg) 3.1 Operating conditions Operating temperature -35C to +55C Daily average temp
Standards IEC60044-1; IEC 61869-2; ANSI C57.13; NTC 2205; GB1208-2006 Accuracy Class 0.5%, 1% Range of primary rated current 300-3000A Range of Rated load 25VA Rated frequency 50/60Hz Rated secondary current 5A or 1A Secondary winding power frequency withstand voltage 3kV, 1min Safety Factor Rating (FS)
The CT can be mounted to existing panels, such as control centers or load centers, to measure or monitor wattage. These CTs can be mounted without removing existing cables for easier installation.
Split core Current transformer: 1) HK-23: Inner hole 20*30mm, Ratio: 100/5A, 150/5A, 200/5A, 250/5A, 300/5A, 400/5A 2) HK-58: Inner hole 50*80mm, Ratio: 250/5A, 300/5A, 400/5A, 500/5A, 600/5A, 750/5A, 800/5A, 1000/5A 3) HK-812: Inner hole 80*120mm, Ratio: 500/5A, 600/5A, 750/5A, 800/5A, 1000/5A, 1200/5A, 1250/5A, 1500/5A, 1600/5A, 2000/5A, 2500/5A, 3000/5A, 4000/5A 4) HK-816: Inner hole 80*160mm, Ratio: 1000/5A, 1200/5A, 1500/5A, 1600/5A, 2000/5A, 2500/5A, 3000/5A, 4000/5A, 5000/5A, 6000/5A, 7500/5A, 8000/5A
1:The structure of the self-locking, safe, easy to install, portable 2:Wide inner window, allowing clamping of big cables or bus-bars 3:Wide range of sizes to accommodate all the existing installations 4:Isolated plastic case recognized according to UL94-V0 5:Wires plugs,Audio plugs,Power plugs and so on five kinds of plugs 1:Current measurement, monitoring and protection for electrical wiring and equipment. 2:Current and power measurement for electric motors, lighting, aircompressor,heating and ventilation system, air-condition equipment and automation – control system. 3:Current, power and energy monitoring device. 4:Relay protection device.
HACT series provide precision measurement for energy monitoring applications to sensing power loading equipment without interrupting the lines. It has been specifically designed to be easy to open and yet maintain the accuracy required for intelligent meters, quick to fit around cables.
• Rated current: 5 or 50A • High accuracy • Customized specifications are accepted. Carton.
1.Operating temperature range:-20 to +45 2.Storage temperature:-40 to 70 3.Switching frequency:1khz to 200khz 4.Withstanding voltage:1500/3750vac for 1 minute between primary and secondary 5.Insulation resistance:500vdc 100m¦¸ miin. Between primary&secondary. As per customer's requirment
ABO Series (8 frames) perfect designed plastic case current transformer, advanced snap on body, high accuracy (up to Class 0.2S), humanization transparent cover and lead seal hole design makes the CT very easy to indentify after long term use and perfect anti-stealing electricity. Features 1:Safe, easy to install, portable 2:Wide inner window, allowing clamping of big cables or bus-bars 3:Wide range of sizes to accommodate all the existing installations Applications: 1:Current measurement, monitoring and protection for electrical wiring and equipment. 2:Current and power measurement for electric motors, lighting, air compressor, heating and ventilation system, air-condition equipment and automation - control system. 3:Current, power and energy monitoring device. 4:Relay protection device.
MBO Series (9 frames) perfect designed plastic case current transformer, advanced snap on body, high accuracy (up to Class 0.2S), humanization transparent cover and lead seal hole design makes the CT very easy to indentify after long term use and perfect anti-stealing electricity. Features 1:Safe, easy to install, portable 2:Wide inner window, allowing clamping of big cables or bus-bars 3:Wide range of sizes to accommodate all the existing installations Applications: 1:Current measurement, monitoring and protection for electrical wiring and equipment. 2:Current and power measurement for electric motors, lighting, air compressor, heating and ventilation system, air-condition equipment and automation - control system. 3:Current, power and energy monitoring device. 4:Relay protection device.
The MES series of current transformer are convenient for mounting in many ways.The most current transformer need the special mounting and the MES series used the mounting of DIN typing without a lot of times.The protective cover for terminal block used the switching device with safety and quick. Feature: 1:Three built in fixing methods: Panel/Din Rail/Busbar 2:Built in hinged terminal cover 3:Compact design 4:Primary current up to 3000A Applications: 1:Current measurement, monitoring and protection for electrical wiring and equipment. 2:Current and power measurement for electric motors, lighting, air compressor, heating and ventilation system, air-condition equipment and automation - control system. 3:Current, power and energy monitoring device. 4:Relay protection device.
CP range of current transformers are compact-smaller than other models with the current ratio of the transformer is small.Clamshell-style terminal cover is well protected by the second terminal. With related accessories you can use Din rail mounting a current from 5A to 3000A. Features: Three built in fixing methods: Panel/Din Rail/Busbar Built in hinged terminal cover Compact design Primary current from 5A to 3000A Applications: Current measurement, monitoring and protection for electrical wiring and equipment. Current and power measurement for electric motors, lighting, air compressor, heating and ventilation system, air-condition equipment and automation-control system. Current, power and energy monitoring device. Relay protection device.
The DM series current transformers (CT) are installed in electric systems to reduce the line current to a secondary value of 5A, which is compatible with current inputs of digital multimeters or protection relays.These are without primary winding and are used for high primary current values from 50A upward.The number of loops of the primary cable does not modify the accuracy but converts the primary current value proportional to secondary current. Features 1:Safe, easy to install, portable 2:Wide inner window, allowing clamping of big cables or bus-bars 3:Wide range of sizes to accommodate all the existing installations Applications: 1:Current measurement, monitoring and protection for electrical wiring and equipment. 2:Current and power measurement for electric motors, lighting, air compressor, heating and ventilation system, air-condition equipment and automation - control system. 3:Current, power and energy monitoring device. 4:Relay protection device.
MSQ range of current transformers can be applied to test,control,display and record the running of the electrical equipment,and to protect the equipment against the damage,in the AC circuit with the rated voltage value below 720V and the frequency of 50-60Hz.The product can be also applied to form a complete set of mine transformer Feature: 1: Safe. Easy to install, porttable 2:Wide inner window, allowing clamping of big cables or bus-bars 3:Wide range of sizes to accommodate all the existing installations Application 1:Current measurement, monitoring and protection for electrical wiring and equipment 2:Current and power measurement for electric motors, lighting , air compressor , heating and ventilation system, air-condition equipment and automation-control system 3: Current , power and energy monitoring device. 4: Relay prtection device.
SLC range of current transformers advanced snap on body, high accuracy (up to Class 0.2S), humanization transparent cover and lead seal holedesign makes the CT very easy to indentify after long term use and perfect anti-stealing electricity. Feature: 1:Built in hinged terminal cover 2:Built in transparent cover for name plate 3:Wide range accuracy (3, 1, 0.5, 0.5S, 0.2, 0.2S) enables meet the worldwide requirement. 4:Primary current from 5A to 5000A. Application: 1:Current measurement, monitoring and protection for electrical wiring and equipment. 2:Current and power measurement for electric motors, lighting, air compressor, heating and ventilation system, air-condition equipment and automation-control system. 3:Current, power and energy monitoring device. Relay protection device.
Rct range of current transformers can be applied to test, control, display and record the running of the electrical Equipment, and to protect the equipment against the damage, in the ac circuit with the rated voltage value below 720v and the Frequency of 50-60hz.The product can be also applied to form a complete set of mine transformer. Rct have larger capacity. With the method of fixed installation. Feature 1:safe, easy to install, portable 2:wide inner window, allowing clamping of big cables or bus-bars 3:wide range of sizes to accommodate all the existing installation. Applications : 1:current measurement, monitoring and protection for electrical wiring and equipment. 2:current and power measurement for electric motors, lighting, air compressor, heating and ventilation system, 3:current, power and energy monitoring device. 4:relay protection device
Lmk3 range of current transformers can be applied to test, control, display and record the running of the electrical equipment, And to protect the equipment against the damage, in the ac circuit with the rated voltage value below 720v and the frequency of 50-60hz. The product can be also applied to form a complete set of mine transformer Features: 1:safe, easy to install, portable 2:wide inner window, allowing clamping of big cables or bus-bars 3:wide range of sizes to accommodate all the existing installations Applications: 1:current measurement, monitoring and protection for electrical wiring and equipment. 2:current and power measurement for electric motors, lighting, air compressor, heating and ventilation system, Air-condition equipment and automation-control system. 3:current, power and energy monitoring device. 4:relay protection device