25 tests per box
Lowest detection line:200 copy/ml CE marks
The COVID-19 RT-PCR Detection Kit is a real-time RT-PCR test intended for the qualitative detection of nucleic acid from the SARS-CoV-2 in upper and lower respiratory specimens (such as anterior nasal swabs, mid-turbinate nasal swabs, nasopharyngeal swabs, oropharyngeal swabs, sputum, lower respiratory tract aspirates, bronchoalveolar lavage, and nasopharyngeal wash/aspirate or nasal aspirate) from individuals suspected of COVID-19 by their healthcare provider. Testing is limited to laboratories certified under the Clinical Laboratory Improvement Amendments (CLIA) of 1988, 42 U.S.C. 263a, to perform high complexity tests. Results are for the identification of SARS-CoV-2 RNA. The SARS-CoV-2 RNA is generally detectable in upper and lower respiratory specimens during the acute phase of infection. Positive results are indicative of the presence of SARS-CoV-2 RNA; clinical correlation with patient history and other diagnostic information is necessary to determine patient infective status. The agent detected may not be the definite cause of disease. Positive results do not rule out bacterial co-infection with other viruses. Laboratories within the United States and its territories are required to report all positive results to the appropriate public health authorities. Negative results do not preclude SARS-CoV-2 infection and should not be used as the sole basis for patient management decisions. Negative results must be combined with clinical observations, patient history, and epidemiological information. The COVID-19 RT-PCR Detection Kit is intended for use by qualified trained clinical laboratory personnel specifically instructed and trained in the techniques of real-time PCR and in vitro diagnostic procedures. The COVID-19 RT-PCR Detection Kit is only for use under the Food and Drug Administration's Emergency Use Authorization. PRINCIPLE OF DETECTION This product is a fluorescent probe-based Taqman RT-PCR assay system. Firstly, the RNA of SARS-CoV-2 will be reverse transcribed into cDNA by reverse transcriptase, and then PCR amplification will be performed with cDNA as template. During amplification of the template, the TaqMan probe will be degraded due to the 5'-3 polymerase activity and exonuclease activity of Taq DNA polymerase, then the separation of fluorescent reporter and quencher enables the fluorescent signal to be detected by instrument. The ORF1ab gene of SARS-CoV-2 will be detected qualitatively by FAM channel, the N gene of SARS-CoV-2 will be detected qualitatively by JOE channel, the E gene of SARS-CoV-2 will be detected qualitatively by ROX channel, and the internal reference will be detected by CY5 channel. dUTP and UNG enzyme are used in the kit to prevent contamination of the amplified products. Internal reference is used in the kit for quality control starting from sample collection
Indication: Qualitative detection of nucleic acid from SARS-CoV-2 in upper and lower respiratory specimens (such as anterior nasal swabs, mid-turbinate nasal swabs, nasopharyngeal swabs, oropharyngeal swabs, sputum, lower respiratory tract aspirates, bronchoalveolar lavage, and nasopharyngeal wash/aspirate or nasal aspirate) from individuals suspected of COVID-19 by their healthcare provider. Emergency use of this test is limited to authorized laboratories. Authorized Laboratories: Laboratories certified under the Clinical Laboratory Improvement Amendments of 1988 (CLIA), 42 U.S.C. 263a, to perform high complexity tests. This letter is in response to your1 request that the Food and Drug Administration (FDA) issue an Emergency Use Authorization (EUA) for emergency use of your product,2 pursuant to Section 564 of the Federal Food, Drug, and Cosmetic Act (the Act) (21 U.S.C. 360bbb-3). On February 4, 2020, pursuant to Section 564(b)(1)(C) of the Act, the Secretary of the Department of Health and Human Services (HHS) determined that there is a public health emergency that has a significant potential to affect national security or the health and security of United States citizens living abroad, and that involves the virus that causes COVID-19. Pursuant to Section 564 of the Act, and on the basis of such determination, the Secretary of HHS then declared that circumstances exist justifying the authorization of emergency use of in vitro diagnostics for detection and/or diagnosis of the virus that causes COVID-19 subject to the terms of any authorization issued under Section 564(a) of the Act. Having concluded that the criteria for issuance of this authorization under Section 564(c) of the Act are met, I am authorizing the emergency use of your product, described in the Scope of Authorization of this letter (Section II), subject to the terms of this authorization. I. Criteria for Issuance of Authorization I have concluded that the emergency use of your product meets the criteria for issuance of an authorization under Section 564(c) of the Act, because I have concluded that: 1. The SARS-CoV-2 can cause a serious or life-threatening disease or condition, including severe respiratory illness, to humans infected by this virus; 2. Based on the totality of scientific evidence available to FDA, it is reasonable to believe that your product may be effective in diagnosing COVID-19, and that the known and potential benefits of your product when used for diagnosing COVID-19, outweigh the known and potential risks of your product; and, 3. There is no adequate, approved, and available alternative to the emergency use of your product. 4 II. Scope of Authorization I have concluded, pursuant to Section 564(d)(1) of the Act, that the scope of this authorization is limited to the indication above.
Commodity: Covid-19 RT-PCR Detection Kit Spec.96 tests/kit Price:FOB SHANGHAI USD3.30/test, USD316.8/kit $3.60/TEST CIF NY AIRPORT OR OTHER MAJOR AIRPORTS USA OR EUROPE OR S. AMERICA OR MIDDLE EAST Payment: T/T ADVANCE 50% BALANCE BEFORE DEPARTURE OR Sight Irrevocable TRANSFERABLE LC Delivery: By AIR, 50days after receipt and confirmation of LC
Sample Types : Including Nasopharyngeal swab, Oropharyngeal swab, Sputum Controls : Internal control, UNG enzyme and dUTP used to reduce risk of contamination, false positive and false negative results Product Information Upper and lower respiratory specimens such as anterior nasal swabs, mid-turbinate nasal swabs, nasopharyngeal swabs, oropharyngeal swabs, sputum, lower respiratory tract aspirates, bronchoalveolar lavage, and nasopharyngeal wash/aspirate or nasal aspirate. Authorized Laboratories Laboratories certified under the Clinical Laboratory Improvement Amendments of 1988 (CLIA), 42 U.S.C. 263a, to perform high complexity tests. About Emergency Use Authorization (EUA) This test (1) has not been FDA cleared or approved, (2) has been authorized by FDA under an EUA for use by authorized laboratories, (3) has been authorized only for the detection of nucleic acid from SARS-CoV-2, not for any other viruses or pathogens, and (4) is only authorized for the duration of the declaration that circumstances exist justifying the authorization of emergency use of in vitro diagnostics for detection and/or diagnosis of COVID-19 under Section 564(b)(1) of the Act, 21 U.S.C.360bbb-3(b)(1), unless the authorization is terminated or revoked sooner.
This kit is intended for qualiativein vitro detection of Orf1ab and N genes of Novel Coronavirus 2019-nCoV which are found in throat swab,sputum and alveolar lavage fuid samples of suspected cases of pneumonia,suspected cases of clustering and other patients who need to carry out diagnosis or differential diagnosis of Novel Coronavirus 2019-nCoV infection.
Product Details: Number of Reactions(Preps) per Kit : 100 Brand : Seegene ICMR(Govt) Approved : Yes Test Method : (SARS-CoV-2) RT-PCR Test Time : 2 Hours Cat. No : RP10243X -Detection of COVID-19 specific target genes in a single tube- Reliable result with three target genes- Results within 1 hour and 50 minutes after extraction- Convenient workow on the automated MDx platform- Suitable for high-throughput- Providing whole process control for assay validity- Automated data interpretation with Seegene Viewer Additional Information: Delivery Time: Immediate
Cat No : RP10243X. Detection of COVID-19 specific target genes in a single tube- Reliable result with three target genes- Results within 1 hour and 50 minutes after extraction- Convenient work now on the automated MDx platform- Suitable for high-throughput- Providing whole process control for assay validity- Automated data interpretation with Seegene Viewer.
WE CAN PROVIDE YOU PCR KIT AT PRICE: $1.20/KIT IN BULK QUANTITY VALIDITY: DECEMBER 2023 PRICE: FOB/ CIF (AVAILABLE) QUANTITY AVAILABILITY: 400,000 PCS
The kit is co-developed by Singapore Agency for Science, Technology and Research (A*STAR) Experimental Drug Development Centre, Bioinformatics Institute, The Diagnostics Development (DxD) Hub and Tan Tock Seng Hospital. The kit has received Singapore Health Science Authority (HSA) approval (MDPA2020-01) and has been deployed in Singapore public and private hospital labs. qPCR testing for specific RNA in nasopharyngeal swab samples. The analytical Limit of Detection (LOD) at 25 copies/reaction. No cross-reactivity with SARS-CoV, Influenza A H1N1, Influenza A H3N2, Influenza B and MERS-CoV. No false negative has been reported to-date The kit is manufactured in Singapore
COVID-19 RT-PCR TEST - NO RNA PURIFICATION NEEDED! Results in less than 60 minutes, very easy-to-use. Made in USA, with clinical validations all over the world. FDA-EUA approved and CE cleared.
Ezplex�® SARS-CoV-2 G Kit, developed by SML Genetree, is a product that has received Emergency Use Authorization (EUA) from the U.S. Food and Drug Administration (FDA). This is an in vitro diagnostic test that qualitatively detects the nucleic acids of SARS-CoV-2 (RdRp and N genes) in sputum to aid in emergency screening for COVID-19. This product can be used for a large amount of screening tests because it can perform a pooling test, unlike the products that the existing domestic companies have approved for emergency use by the FDA. For the combined test, samples are collected in units of 5 people and tested. If positive, individual tests are performed. In the case of a negative test, all tests are performed in a negative way. In particular, since a large number of samples are tested at once, the test is only possible with high sensitivity and specificity compared to existing diagnostic kits. According to the FDA, it was confirmed that 100% agreement was achieved in the result comparison test of individual and collective tests, and it was the 20th in the world and the first Korean company to pass the test. Excellent clinical performance was demonstrated by confirming high sensitivity and specificity through clinical evaluation, and stability was confirmed for 12 months through long-term storage tests. In January 2021, it was officially approved by the Korean Ministry of Food and Drug Safety (MFDS).
2X Real-Time PCR Master Mix including SYBR Green in Mixture 2X HRM Master mix
One-step real-time-PCR test for qualitative detection of genetic material of SARS-CoV-2 virus in upper and lower respiratory specimens collected from individuals suspected of COVID-19 infection. Targets the RdRp gene and E gene. Products with high specificity and sensitivity for accurate and reliable results.
It has CE certificate 25 test per box
Oxygen Concentrator - 0.5-10L/Min Purityï¼? 96% Compressor Life - 25000hours Sound Level 60dB Screen - LED Segment real-time display Power comsumption - 500VA Net Weight - 23k Gross weight:27kg
COVID-19 Chip-based Real Time PCR Test is a semi quantitative detection of RNA in human oropharyngeal and nasopharyngeal swab specimen and aids in detection and confirmation of infection and diagnosis of COVID-19. The test detects the E and Orf1a genes of the virus.
RT PCR-Detection Kit
RT PCR TEST KITS FOR COVID ARE AVAILABLE DIRECTLY FROM MANUFACTURERS IN SOUTH KOREA. No intermediaries. Please contact For quotes only if you are a buyer.