One-step real-time-PCR test for qualitative detection of genetic material of SARS-CoV-2 virus in upper and lower respiratory specimens collected from individuals
suspected of COVID-19 infection.
Targets the RdRp gene and E gene.
Products with high specificity and sensitivity for accurate and reliable results.
USD$18.00 AccuPowe COVID-19 Real-Time RT-PCR Kit is an in vitro diagnostic kit that helps diagnose COVID-19 infections, detects SARS-CoV-2 (E gene and RdRp gene) RNA from a suspected infection patient's sample (such as sputum, nasopharyngeal swab, oropharyngeal swab) through Real-Time Polymerase chain reaction(PCR) using ExiStation Universal MDx system. Validated to: Bio-Rad CFX96 ABI 7500 Fast Target Genes: Rdrp, E
COVID-19 RT-PCR TEST - NO RNA PURIFICATION NEEDED! Results in less than 60 minutes, very easy-to-use. Made in USA, with clinical validations all over the world. FDA-EUA approved and CE cleared.
Our test kit has been approved and endorsed by Singapore's MOH (Ministry of Health) and HSA (Health Science Authority) since last year and we have been constantly supplying to the APAC countries during this period. (Japan, India, Singapore, Malaysia, Indonesia and etc.) * CE mark was attained in December 2020. * Our Tepat 1.0 SARS-CoV-2 RT-PCR provides for high-throughput, sensitive and specific detection of SARS-CoV-2 RNA extracted from nasopharyngeal swabs*. It can detect 6 copies of viral RNA per reaction with > 95% confidence. Clinical validation shows 100% sensitivity, with no cross-reaction with non-SARS-CoV-2 species. Key Highlights 1.5 hours from RNA to results Multiplex RdRp and M viral genes detection enhances sensitivity and specificity 100% coverage with 100% identity of all SARS-CoV-2 genomes in the world Detects 6 copies of viral RNA Whole process control: human RNase P
FAST: Results in under 2 minutes ACCURATE: 99.9% specificity and 98.7% sensitivity EASY TO USE: Convenient for testing at home PAINLESS: Simple and painless saliva collection RELIABLE: 24-Hour RT-PCR Confirmation (100% specific and 100% sensitive) 99.9% specificity. Test specificity this high ensures that almost all the people who are not infected get a negative test result with the Sensiva React Rapid Covid-19 Testing Kit. Using a fast and accurate test such as this one is vital when we are trying to stop virus transmission and protect general health. 98.7% sensitivity Test sensitivity refers to the percentage of infected people who get a positive test result. In our case that means that 98.7% of people with an infection get a positive test result. How to use it? Step 1 â?? Do the test Sensiva React Rapid Test is a simple test that can be� easily done at home. It is convenient and� painless� since it requires you to collect a saliva sample instead of a nasal swab. How to do it? First, use the mobile application to scan the QR code to register. After that, collect a saliva sample and add it into the saliva hole in the reader device before adding the liquid solution. You will be able to interpret your� results in under 2 minutes. Watch a video with detailed instructions on how to do the test in the video below. Please follow the instructions carefully to obtain a valid test result. Step 2 â?? Get RT-PCR confirmation in 24 hours You can use the prepaid shipping label and send the saliva sample used for the rapid test to us. You will get an official PCR result (100% sensitivity and 100% specificity) in 24 hours. Our lab is certified under the Clinical Laboratory Improvement Amendments (CLIA), so you can rely on us to provide you with accurate and reliable test results. Who is Sensiva React Rapid Covid-19 Test for? Sensiva React Rapid Covid-19 Test is designed for patients with COVID-19 symptoms or those who are asymptomatic but suspected of having exposure. Its easy-to-follow instructions make it convenient for testing at home. The kit contains: (1) Specimen Tube (1) Saliva Funnel (1) Dropper (1) Bio-hazard bag with absorbent pad (1) Lateral flow device (1) 5ml EZ-Tear Saline Solution (1) 0.3ml EZ-Tear Buffer Solution (1) Written Instruction Card
The COVID-19 RT-PCR Detection Kit is a real-time RT-PCR test intended for the qualitative detection of nucleic acid from the SARS-CoV-2 in upper and lower respiratory specimens (such as anterior nasal swabs, mid-turbinate nasal swabs, nasopharyngeal swabs, oropharyngeal swabs, sputum, lower respiratory tract aspirates, bronchoalveolar lavage, and nasopharyngeal wash/aspirate or nasal aspirate) from individuals suspected of COVID-19 by their healthcare provider. Testing is limited to laboratories certified under the Clinical Laboratory Improvement Amendments (CLIA) of 1988, 42 U.S.C. 263a, to perform high complexity tests. Results are for the identification of SARS-CoV-2 RNA. The SARS-CoV-2 RNA is generally detectable in upper and lower respiratory specimens during the acute phase of infection. Positive results are indicative of the presence of SARS-CoV-2 RNA; clinical correlation with patient history and other diagnostic information is necessary to determine patient infective status. The agent detected may not be the definite cause of disease. Positive results do not rule out bacterial co-infection with other viruses. Laboratories within the United States and its territories are required to report all positive results to the appropriate public health authorities. Negative results do not preclude SARS-CoV-2 infection and should not be used as the sole basis for patient management decisions. Negative results must be combined with clinical observations, patient history, and epidemiological information. The COVID-19 RT-PCR Detection Kit is intended for use by qualified trained clinical laboratory personnel specifically instructed and trained in the techniques of real-time PCR and in vitro diagnostic procedures. The COVID-19 RT-PCR Detection Kit is only for use under the Food and Drug Administration's Emergency Use Authorization. PRINCIPLE OF DETECTION This product is a fluorescent probe-based Taqman RT-PCR assay system. Firstly, the RNA of SARS-CoV-2 will be reverse transcribed into cDNA by reverse transcriptase, and then PCR amplification will be performed with cDNA as template. During amplification of the template, the TaqMan probe will be degraded due to the 5'-3 polymerase activity and exonuclease activity of Taq DNA polymerase, then the separation of fluorescent reporter and quencher enables the fluorescent signal to be detected by instrument. The ORF1ab gene of SARS-CoV-2 will be detected qualitatively by FAM channel, the N gene of SARS-CoV-2 will be detected qualitatively by JOE channel, the E gene of SARS-CoV-2 will be detected qualitatively by ROX channel, and the internal reference will be detected by CY5 channel. dUTP and UNG enzyme are used in the kit to prevent contamination of the amplified products. Internal reference is used in the kit for quality control starting from sample collection