Product Details: Number of Reactions(Preps)/Kit : 96 Wells Brand : CTK BioTech Sample : Serum / Plasma Storage : 2-8 C Cat No : AE0315 The TRUSTwell CHIK IgM Test is a solid phase enzyme linked immunoabsorbent assay for the qualitative detection of IgM anti- Chikungunya virus in human serum or plasma. It is intended for professional use only as an aid in the diagnosis of acute infection with Chikungunya viruses. Any reactive specimen with the TRUSTwell CHIK IgM Test must be confirmed with alternative testing method(s) and clinical findings. TEST PRINCIPLE: TRUSTwell CHIK IgM Test is a solid phase enzyme linked immunoabsorbent assay based on the principle of the indirect immunoassay technique for the detection of IgM anti- Chikungunya virus in human serum or plasma. The TRUSTwell CHIK IgM Test is composed of two key components: 1) Solid microwells pre-coated with recombinant CHIK antigen(s); 2) Liquid conjugates composed of monoclonal anti-human IgM reagent conjugated with horse reddish peroxidase (HRP-anti-Human IgM conjugates). During the assay, the test specimen is first incubated with the coated microwells. IgM anti- Chikungunya virus, if present in the specimen, binds to the antigen coated on the microwell surface. In the second incubation with the HRP-anti Human IgM conjugates, the IgM antiChikungunya antibody absorbed on the surface of microwell reacts to the conjugates, forming a complexed conjugates. Unbounded conjugates are then removed by washing. The presence of the complexed conjugates is shown by a blue color upon additional incubation with TMB substrate. The reaction is stopped with Stop Solution and absorbances are read using a spectrophotometer at 450 /620-690 nm. Clinical Performance: A total of 336 specimens from susceptible subjects were tested by TRUSTwell CHIK IgM and by a commercial reference ELISA kits. Relative Sensitivity: 91.3 %, (95 % CI: 73.2 % -97.6 %) Relative Specificity: 96.8 %, (95 % CI: 94.2 % -98.3 %) Overall Agreement: 96.4%, (95 % CI: 93.9 % -98.0 %).
Product Details: Number of Reactions(Preps)/Kit : 96 Wells Brand : InBios Sample Material : Serum Format : Immunocapture Incubation Time : 30+30+30+10 Cat No : CHKM-R The CHIKjj Detect IgM ELISA is designed for the qualitative detection of IgM antibodies present in human serum targeting Chikungunya virus E2/E1 proteins. This test is not intended to screen blood or blood components. This test is for research use only. Not for use in diagnostic procedures. The complete kit includes one 96 well strippable plate with all necessary reagents and controls. Key Features : InBios chikungunya kits have been developed using a novel technology1 that outperforms traditional antigen preparations, resulting in highly sensitive detection of recent and past CHIKV infection. Excellent results in CDC evaluation of commercially available chikungunya IgM assays. Ordering: Cat No CHKM-R Formet Immunocapture Quantity 96 wells/Plate Incubation Time 30 + 30 + 5 + 10 Sample Type Serum Storage 2-8 Shelf Life 12 months
Product Details: Brand : CTK BIOTECH Size : 96 Well Specimen : Serum & Plasma stored at 2 - 8 C Cat No : E0100 The RecombiLISA HAV IgM ELISA is a solid-phase enzyme-linked immunosorbent assay for the qualitative detection of IgM anti-hepatitis A virus in human serum or plasma. Product Features: Utilizes IgM capture technique Detects IgM anti-HAV in serum or plasma Evaluated with BBI HAV serum conversion and HAV mixed titer performance panels Useful for identifying acute HAV infections Product Specification: Microwells coated with anti-human IgM antibody HAV IgM negative control HAV IgM positive control HRP-HAV conjugates Wash buffer (30 x concentrate) TMB substrate A TMB substrate B Stop solution ELISA Working Sheet Product insert
Product Details: Number of Reactions(Preps)/Kit : 96 Wells Brand : CTK BioTech Sample Material : Plasma/Serum Storage : 2-8 C Cat. No : E0105 INTENDED USE: The RecombiLISA HEV IgM ELISA is a solid-phase enzyme-linked immunosorbent assay for the qualitative detection of anti-hepatitis E virus (HEV) IgM in human serum or plasma. It is intended for professional use only and to be used as an aid in the diagnosis of infection with HEV. TEST PRINCIPLE: The RecombiLISA HEV IgM ELISA is a solid-phase enzyme-linked immunosorbent assay based on the principle of the IgM capture technique for the detection of antiHEV IgM in human serum or plasma. The RecombiLISA HEV IgM ELISA is composed of two key components: 1) Solid microwells pre-coated with polyclonal anti-human IgM antibody 2) Liquid conjugate composed of HEV antigen conjugated with horseradish peroxidase (HRP-HEV Conjugate) During the assay, the test specimen is first incubated in the coated microwells. AntiHEV IgM, if present in the specimen, binds to the antibody coated on the microwell surface. Any unbound specimen is then removed by a wash step. During a second incubation with the HRP-HEV Conjugate, the anti-HEV IgM antibody is absorbed on the microwell surface which binds to the HRP-HEV Conjugate, forming a conjugate complex. Unbound conjugate is then removed by washing. After addition of the TMB substrate, the presence of conjugate complex is shown by development of a blue color resulting from a reaction between the enzyme and substrate. The reaction is then quenched by addition of the Stop Solution, and the absorbance value for each microwell is determined using a spectrophotometer at 450/620-690 nm. Clinical Performance: A total of 400 specimens from susceptible subjects were tested by the RecombiLISA HEV IgM ELISA and by a Chinese State Drug Administration (SFDA) licensed reference EIA. Clinical Performance: Relative Sensitivity: 100%, Relative Specificity: 100%, Overall Agreement: 100%.
Product Details: Number of Reactions(Preps)/Kit : 96 Wells Brand : CTK BioTech Sample : serum or plasma Storage : 2-8 C Cat No : E0330 The RecombiLISA Leptospira IgM ELISA Kit is an indirect, solid phase enzyme-linked immunosorbent assay. The two main kit components are: 1) A 96 breakable well plate with the solid microwells pre-coated with L. interrogans antigen. 2) Liquid conjugates composed of monoclonal anti-human IgM reagent conjugated with horseradish peroxidase (HRP-anti-human IgM conjugates). This test is intended to be used for the qualitative detection of IgM anti-Leptospira interrogans (L. interrogans) in human serum or plasma. It is intended to be used by professionals as an aid in the diagnosis of acute infection with L. interrogans. Any interpretation or use of this test result must also rely on other clinical findings as well as on the professional judgment of health care providers. Recommended for use: Any person presenting with clinical signs or symptoms consistent with acute infection with interrogansincluding: high fever, headache, chills, muscle aches, vomiting, jaundice, red eyes, abdominal pain, diarrhea, skin rash After exposure to a known contaminated source Product Features : Sensitivity: 86.7% Specificity: 96.8% Cross Reactivity: No false positive results were observed on specimens from Dengue, Malaria, Typhi, ANA, HAMA, RF, HIV, HBsAg, HCV, Syphilis, pylori Interference: No interference was seen with substances: Salicylic acid: 4.34 mmol/L; Glucose: 55 mmol/L; Sodium citrate: 1.3 %;Heparin: 3,000 U/L; Creatinine: 5 mmol/L; Bilirubin: 10 mg/dL; EDTA: 3.4 �µmol/L Shelf life: 12 months Open vial stability: 8 weeks at 2-8 C, or until the expiration date Kit Components : Microwells coated with recombinant L. interrogans antigens Lepto IgM positive control Lepto IgM negative control Sample diluent HRP anti-human IgM conjugate Wash buffer (30 x concentrate) TMB substrate A TMB substrate B Stop solution ELISA Working Sheet Product insert
Product Details: Number of Reactions(Preps)/Kit : 96 Wells Bran : CTK BioTech Sample Material : serum or plasma Storage : 2-8 C Cat. No : AE0310 The Dengue IgM ELISA Kit is a solid-phase enzyme-linked immunosorbent assay for the qualitative detection of IgM anti-dengue viruses (DEN1, 2, 3, 4) in human serum or plasma. It is intended for professional use only as an aid in the diagnosis of acute infection with dengue viruses. TEST PRINCIPLE: The Dengue IgM ELISA Kit is a solid-phase enzyme-linked immunosorbent assay based on the principle of the capture immunoassay methodology for the detection of IgM anti-dengue virus in human serum or plasma. The Dengue IgM ELISA Kit is composed of two key components: 1) Solid microwells pre-coated with mouse monoclonal anti-human IgM antibody. 2) Conjugate working solution composed of dengue antigen and HRP-anti-dengue conjugates. During the assay, the test specimen is first incubated in the coated microwell. IgM antidengue, if present in the specimen, binds to the anti-human IgM antibodies coated on the microwell surface, and any unbound specimen is then removed by a wash step. During a second incubation with HRP-anti-dengue conjugate working solution, the IgM anti-dengue absorbed on the surface of microwell binds to the conjugate through dengue antigen, forming a conjugate complex. Unbound conjugates are then removed by washing. After addition of the TMB substrate, the presence of the conjugate complex is shown by development of a blue color resulting from a reaction between the enzyme and substrate. This reaction is then quenched by addition of the Stop Solution, and the absorbance value for each microwell is determined using a spectrophotometer at 450/620-690 nm. Accuracy of Detection : A total of 491 patient specimens were collected from susceptible subjects and tested by Dengue IgM ELISA Kit and by a commercial leading brand EIA. Relative Sensitivity: 90.8% (95% Confidence Interval = 85.5 - 94.4%) Relative Specificity: 95.9% (93.1 - 97.7%) Overall Agreement: 94.1% (91.6 - 95.9%).
Product Details: Brand : Abbott Package type : Microplate Pack size : 96wells/Kit Specimen : Serum Description : Dengue IgM Capture ELISA Cat.No. : 11EK20 Bioline DENGUE IgM CAPTURE ELISA In primary infection with the dengue virus, IgM antibody becomes detectable about five days after disease onset, when circulating virus declines in the blood. IgM level rises quickly to peak at about 2 weeks and declines to undetectable levels after 2-3 months In secondary infections, IgM response is typically at a lower level compared to that in a primary infection. Early diagnosis of dengue infection (especially in primary dengue infection) High accuracy with all dengue serotypes (DEN1,2,3, and 4) Simple and easy to use: All necessary reagents included in the kit Shelf life and storage temperature: 18 months from the date of manufacturing at 2-8 C Included in the WHO Bulk Procurement Scheme Performance: Sensitivity 96.4 %, Specificity 98.9 % (vs. HAI test).
Product Details: Number of Reactions(Preps)/Kit : 96 Wells Brand : InBios Sample Material : Serum Incubation Time: 60+60+60+5+10+1 Storage 2-8 C Cat No : DDMS-1 The DENV DetectTM IgM Capture ELISA is for the qualitative detection of IgM antibodies to DENV recombinant antigens in serum for the presumptive clinical laboratory diagnosis of Dengue virus infection. The assay is intended for use only in patients with clinical symptoms consistent with either dengue fever or dengue hemorrhagic fever. The complete kit includes one 96 well strippable plate with all necessary reagents and controls. 1st Assay to Receive FDA Clearance. Performance thoroughly evaluated with clinically confirmed cases of dengue 1-4 serotypes. Excellent positive and negative agreement with WHO reference panel (>90%). Improves accuracy by monitoring background reactivity with a normal cell antigen. Employs a simple, one step ratio method of interpretation. CE Marked.
Product Details: Number of Reactions(Preps)/Kit : 50 Brand : SD ICMR Approved : Yes Result Time (Rapid Kits) : 15 min Sample Type : Oral & Nasal Swab STANDARD E Dengue IgM ELISA analyzes IgM antibodies specific to Dengue virus in serum and plasma using enzyme linked immunosorbent assay.
Product Details: Number of Reactions(Preps)/Kit : 96 Wells Brand : InBios Sample Material : Serum Format : ELISA Incubation Time : 30 + 30 + 5 + 10 + 1 Cat No : STMS-R The Scrub Typhus Detect IgM ELISA for exposure to Orientia tsutsugamushi (OT; formerly Rickettsia) is an ELISA system for the detection of IgM antibodies in human serum to OT-derived recombinant antigen. This test is for research use only. Not for use in diagnostic procedures. The complete kit includes one 96 well strippable plate with all necessary reagents and controls.
Product Details: Number of Reactions(Preps)/Kit ; 96 Wells Brand : InBios Format : Immunocapture Specimen : Serum Cat No : ZKM2-1 The ZIKV Detect 2.0 IgM Capture ELISA is intended for the qualitative detection of Zika virus IgM antibodies in human sera for the presumptive clinical laboratory diagnosis of Zika virus infection. The assay is intended for use only in patients with clinical signs and symptoms consistent with Zika virus infection, and/or CDC Zika virus epidemiological criteria (e.g., history of residence in or travel to a geographic region with active Zika transmission at the time of travel, or other epidemiological criteria for which Zika virus testing may be indicated). Assay results are for the presumptive detection of IgM antibodies to Zika virus (ZIKV). Positive results must be confirmed by following the latest CDC guidelines for the diagnosis of Zika virus infection. Results of this test are intended to be used in conjunction with clinical observations, patient history, epidemiological information, and other laboratory evidence to make patient management decisions. Zika IgM levels are variable over the course of the infection and may be detectable near day four post onset of symptoms and persist up to approximately 12 weeks following initial infection. Negative results may be seen in specimens collected before day four post onset of symptoms or after the window of detectable IgM closes, and therefore do not preclude the possibility of Zika virus infection, past or present. 1st Commercial serology kit to receive FDA Marketing Authorization CE Marked Differentiates Zika IgM positive patients from those infected with other flaviviruses such as West Nile or Dengue Sensitivity: >90% Specificity: >96% Results in 4 hours Tests up to 28 unknown specimens.
Product Name: Surplex(R)-COVID-19 IgM/IgG Rapid test Product Description: Surplex(R)-COVID-19 IgM/IgG Rapid test is a serology test intended for the qualitative detection of IgM and IgG antibodies of the novel coronavirus (the SARS-COV-2 virus) in human serum, plasma or whole blood. It is CE marked and approved in Brazil (ANVISA approved). We are motivated to aggressively price our product and ready to send 20 tests (one box) to qualified buyers for evaluation, free of charge. Price of product: FOB USD $1.50 - $2.50 per test, volume dependent. Product origin : China. Key Specifications/Special Features : - Competitively priced and ready to ship in volume. - Currently shipping in volume to Brazil. - Highly accurate and specific - performance independently confirmed. - Results ready in 15 minutes. - Harmonization System (HS) Code: 382200. - We provide a full support during regulatory application. Minimum Order Size and Packaging details: MOQ: Flexible. Box of 20 or 50 test kits. Storage: 2-30C. Shelf Life: 10 months.
Sesame Seeds Commercial Ventures takes pride in providing high- quality Sesame seeds to global markets. Sesame seeds are small, oil- rich seeds derived from the Sesamum indicium plant, widely recognized for their culinary nutritional significance. Our sesame seeds are sourced from Toba, Jhang, Fateh Jhang, Hyderabad, Nawabshah, etc. We deal in both black and white sesame seeds which are processed as per customer requirements. Hulled Sesame Seeds: Our hulled sesame seeds are meticulously processed to remove the outer husk, resulting in a creamy-white seed with a mild, nutty flavor. They are a popular choice for baking, confectionery, and garnishing due to their clean appearance. Product Specifications Sesame Physical Characteristics Colour Hulled (creamy white) Machine Washed (natural) Sortex (uniform) Size Varies by grade (Standard, Premium, Superior) Moisture Content Below 6% Impurities Less than 0.1% Foreign Material Nil As per our latest test results, product specifications are as follows : Hulled S.No PARAMETERS METHODS USED ANALYSIS RESULTS UNIT 1 TOTAL AFLATOXIN (B1=B2=G1+G2) ELISA KIT METHOD
Intended Use The One Step HAV IgG/IgM Test is a rapid chromatographic immunoassay for the qualitative detection of antibodies (IgG and IgM) to Hepatitis A Virus (HAV) in Whole Blood /Serum / Plasma to aid in the diagnosis of Hepatitis A Virus. Summary Hepatitis A is an acute, usually self-limiting disease of the liver caused by hepatitis A virus (HAV). HAV is transmitted from person to person, primarily by the faecal-oral route. The incidence of hepatitis A is closely related to socioeconomic development, and seroepidemiological studies show that prevalence of anti-HAV antibodies in the general population varies from 15% to close to 100% in different parts of the world. One step HAV IgG/IgM Test is a simple, visual qualitative test that detects Hepatitis A Virus antibodies in human Whole Blood /Serum / Plasma. The test is based on immunochromatography and can give a result within 15 minutes. Principle The One Step HAV IgG/IgM Test is a qualitative membrane strip based immunoassay for the detection of Hepatitis A Virus antibodies (IgG and IgM) in Whole Blood /Serum / Plasma. The test device consists of: 1) a burgundy colored conjugate pad containing HAV recombinant envelope antigens conjugated with Colloid gold (HAV conjugates) and rabbit IgG-gold conjugates,2) a nitrocellulose membrane strip containing two test bands (T1 and T2 bands) and a control band (C band). The T1 band is pre-coated with the antibody for the detection of IgM anti-HAV, T2 band is coated with antibody for the detection of IgG anti-HAV, and the C band is pre-coated with goat anti rabbit IgG. When an adequate volume of test specimen is dispensed into the sample well of the test cassette, the specimen migrates by capillary action across the cassette. IgG anti-HAV, if present in the specimen, will bind to the HAV conjugates. The immunocomplex is then captured by the reagent pre-coated on the T2 band, forming a burgundy colored T2 band, indicating a HAV IgG positive test result and suggesting a recent or repeat infection. IgM anti-HAV if present in the specimen will bind to the HAV conjugates. The immunocomplex is then captured by the reagent coated on the T1 band, forming a burgundy colored T1 band, indicating a HAV IgM positive test result and suggesting a fresh infection. Absence of any T bands (T1 and T2) suggests a negative result. The test contains an internal control (C band) which should exhibit a burgundy colored band of the immunocomplex of goat anti rabbit IgG/rabbit IgG-gold conjugate regardless of the color development on any of the T bands. Otherwise, the test result is invalid and the specimen must be retested with another device. Storage and Stability Store as packaged in the sealed pouch at room temperature or refrigerated (4-30 or 40-86). The test device is stable through the expiration date printed on the sealed pouch. The test must remain in the sealed pouch until use.
Specification Strength/ Size Packing Size Packed In Filariasis Kit Includes One test Strip, Desiccant and Dropper 50 Strip Test Per Pack 50 Box Pack
The Typhoid IgG/IgM Rapid Test is a lateral flow immunoassay for the simultaneous detection and differentiation of anti-Salmonella typhi (S. typhi)G and IgM in human serum or plasma. It is intended to be used as a screening test and as an aid in the diagnosis of infection with S. typhi. Any reactive specimen with the Typhoid IgG/IgM 2.0 Rapid Test must be confirmed with alternative testing method(s).
The Herpes Simplex Virus Rapid Test is a rapid qualitative lateral flow test designed for the quantitive detection of IgG antibodies to Herpes Simplex Virus (HSV) in human serum/plasma samples. HSV-1 is usually associated with infection in oropharyngeal area and eyes, while HSV-2 causes mostly genital and neonatal infections (5, 6), however, the tissue specificity is not absolute (7). HSV-2 can be isolated occasionally from the oropharynx and 5-10% of primary genital infections may be caused by HSV-1. Infants infected with HSV appear normal at birth, but almost invariably develop symptoms during the newborn period (5, 8, 9). Neonatal HSV infection may remain localized or become disseminated. Localized infection may involve one or a combination of sites. These are skin, eyes, mouth or the central nervous system. Disseminated infection is manifested by pneumonitis, hepatitis, disseminated intravascular coagulopathy and encephalitis. Of the infants with neonatal HSV, about one half of those surviving will develop severe neurological or ocular sequelae. A number of serological procedures have been developed to detect antibodies to HSV. These include complement fixation, indirect immunofluorescent antibody, plaque neutralization, and ELISA (6, 8, 10). Antibody of the IgG class is produced during the first 2-3 weeks of infection with HSV and exists only transiently in most patients. Serologic procedures, which measure the presence of IgG antibodies, help discriminate between primary and recurrent infections, since IgG antibodies is rarely found in recurrent infections. High affinity IgG antibodies to HSV, if present in a sample, may interfere with the detection of IgG specific antibody (9). High affinity IgG antibody may preferentially bind to HSV-1 antigen leading to false negative IgG results. Also, rheumatoid factor, if present, along with antigen specific IgG, may bind to IgG causing false positive IgG results. Both problems can be eliminated by deactivating IgG in the sample before testing for IgG.
INTENDED USE THE ONE STEP ANTI-DENGUE (IGM & IGG) TRI-LINE TEST IS A COLLOIDAL GOLD ENHANCED, RAPID IMMUNOCHROMATOGRAPHIC ASSAY FOR THE QUALITATIVE DETECTION OF ANTIBODIES (IGM & IGG) TO DENGUE VIRUS (DV) IN HUMAN WHOLE BLOOD, SERUM OR PLASMA. THIS TEST IS A SCREENING TEST, AND ALL POSITIVES MUST BE CONFIRMED USING AN ALTERNATE TEST SUCH AS WESTERN BLOT. THE TEST IS INTENDED FOR HEALTHCARE PROFESSIONAL USE ONLY. 25PCS/BOX
Intended use The one step anti-dengue (igm & igg) tri-line test is a colloidal gold enhanced, rapid immunochromatographic assay for the qualitative detection of antibodies (igm & igg) to dengue virus (dv) in human whole blood, serum or plasma. This test is a screening test, and all positives must be confirmed using an alternate test such as western blot. The test is intended for healthcare professional use only.
INTENDED USE The One Step RV IgG/IgM Test is a rapid chromatographic immunoassay for the qualitative detection of antibodies (IgG and IgM) to Rubella (Virus) in Whole Blood /Serum / Plasma to aid in the diagnosis of RV infection. The test is based on immunochromatography and can give a result within 15 minutes. PRINCIPLE The One Step RV IgG/IgM Test is a qualitative membrane strip based immunoassay for the detection of RV antibodies (IgG and IgM) in Whole Blood /Serum / Plasma. The test device consists of: 1) a burgundy colored conjugate pad containing RV recombinant envelope antigens conjugated with Colloid gold (RV conjugates) and rabbit IgG-gold conjugates,2) a nitrocellulose membrane strip containing two test bands (T1 and T2 bands) and a control band (C band). The T1 band is pre-coated with the antibody for the detection of IgM anti-RV, T2 band is coated with antibody for the detection of IgG anti-RV, and the C band is pre-coated with goat anti rabbit IgG. When an adequate volume of test specimen is dispensed into the sample well of the test cassette, the specimen migrates by capillary action across the cassette. IgG anti-RV, if present in the specimen, will bind to the RV conjugates. The immunocomplex is then captured by the reagent pre-coated on the T2 band, forming a burgundy colored T2 band, indicating a RV IgG positive test result and suggesting a recent or repeat infection. IgM anti-RV if present in the specimen will bind to the RV conjugates. The immunocomplex is then captured by the reagent coated on the T1 band, forming a burgundy colored T1 band, indicating a RV IgM positive test result and suggesting a fresh infection. Absence of any T bands (T1 and T2) suggests a negative result. The test contains an internal control (C band) which should exhibit a burgundy colored band of the immunocomplex of goat anti rabbit IgG/rabbit IgG-gold conjugate regardless of the color development on any of the T bands. Otherwise, the test result is invalid and the specimen must be retested with another device. Storage and Stability Store as packaged in the sealed pouch at room temperature or refrigerated (4-30â?? or 40-86â??). The test device is stable through the expiration date printed on the sealed pouch. The test must remain in the sealed pouch until use.