Product Nam : Dehydrated White Onion Minced HS Code : 07122000 Category ; White, Pink, Red Packaging Options : 10/12/14 Kgs PP Bag/Cartoon Box or Customized Loading Option : 7.5 MTS (20 FT), 16 MTS (40FT) Aroma : sweet and spicy Size : 1 to 3 mm Product Expiry 2 Years in 5 C - 12 C Storage at Dry Place Source / Origin : India The dehydrated onion minced is a processed form of the dry onion flakes, which are primarily manufactured from the fresh onion to persist the onion flavor for a longer time. Since old age, the fresh onion has taken place in our foods due to its distinct aromatic flavor and medicinal benefits in human life. The onion minced is widely added as an ingredient in various vegetarian and non-vegetarian dishes to add the pungent aromatic flavor of onion. The dried onion minced is produced from the dried onion flakes. Firstly, in this procedure, the plant roots and outer skins from the onion flakes are removed by the sorting process, which improves the quality of the final product. Thereafter, it is processed further through a cutting machine to segregate into smaller pieces. Lastly, it is passed through the Vibro forming table, having 1 x 3 mm size. These fine 1 to 3 mm dried onion particles are also known as the Dried Onion Minced PHYSICAL ANALYSIS Appearance : White Size : 1 to 3 mm Texture : Minced Taste/Flavour : Characteristic aroma, fragrant and pungent CHEMICAL ANALYSIS Moisture Content : 8.0 % Max Total Ash on dry basis : 5.0 % Max Ash Insoluble in dil HCL : 0.5 % Max Peroxide : Negative MICROBIOLOGICAL ANALYSIS Total Viable Count (CFU/g) :
Specifications Fluoroscopic capacity Max rated capacity : tube current 4ma, tube voltage 110kv Automatic fluoroscopy : tube voltage:40kví½110kv adjust Automatically Tube current : 0.3maí½4ma set manually Manual fluoroscopy : continuous tube voltage:40kví½110kv Continuous tube current : 0.3maí½4ma Pulse fluoroscopy : continuous tube voltage 40kví½110kv Continuous tube current 4.1maí½8ma Photography capacity Max rated capacity : 3.5 kw Tube voltage and cur- Rent combination : 40kví½49kv 1 í½125 mas 50kví½59kv 1 í½110 mas 60kví½69kv 1 í½90 mas 70kví½79kv 1 í½80 mas 80kví½89kv 1 í½71 mas 90kví½99kv 1 í½63 mas 100kví½110kv 1 í½40 mas Plateholder size : 200mmíß250mm(8ísíß10ís)or 250mmíß300mmú¿10ísíß12ísú¬ X-ray tube X-ray tube special for high frequency Fixed anode Dual-focus: large focus: 1.5, small focus: 0.6 Inverter frequency: 40khz Thermal capacity: 30kj (40hu) Videosystem Image intensifier : image intensifier made by toshiba (9ísíó 6ísíó4.5ís) Ccd vidicon : ultra low-light ccd camera imported from japan Monitor : horizontal 1000 lines and vertical 800 lines, Bandwidth : 12.5mhz, Image/sec : 75 Ccu(central control) : recursive filter: k=8, 8 images storage, Image upright, image overturnú¼positive & Negative imageú+lih(last image freeze, and Osdú¿monitor displayú¬ Structure Directive wheel : ía90íprevolutionú¼can freely change the moving Direction of the unit. Ascending & descend- Ing range of pillar : í²400mm C-arm : forward and backward movement: 200mm Revolution around horizontal axis: ía180íp Revolution around vertical axis : ía15íp Slip on orbit: 120íp(+90ípí½ -30íp) Packing details : 2440mmíß1100mmíß1420mm N.W. 300kgs g.W.400kgs Packing details : 2440mmíß1100mmíß1420mm N.W. 300kgs g.W.400kgs
*High-frequency generator deliver the power you need for all the typical applications in spine surgery, orthopedics, traumatology, urology and pain management. *Unique design of large thermal capacity(>1000kJ) with advanced heat dissipation technology, allows for clear images, even for long or repeated procedures. *High-resolution CCD camera with 1K x 1K image matrix, over 4000 shades of gray, realizes more accurate diagnose. *Advanced functions of images optimization, strengthen module, real-time displaying the clear clinical images. *Professional working station has more image post-processing functions such as the image W/L adjustment, region of interest balance, GAMMA correction, flip, noise reduction, smoothing, sharpening etc. *Two monochrome 19'' flat-screen monitors clearly visualize the smallest anatomical details.
Cone beam multi-angles radiography *190�°orbital rotation and continuous pulse exposure realize Maximum density projection. *Multi-angle dynamic continuous images on same part can be acquired. *Replay the whole rotation dynamic images,volume rendering technique(VRT). *Multi-angles observation during prepperative,intraoperative and postoperative,ensure accurate and efficient diagnosis and treatment. *Choose appropriate sequence frames according to clinical need.both image quality and radiation protection can be assured. Application *Widely use in Orthopedics,general surgery,orthopedic surgery,urology,spinal surgery, abdominal surgery,gastroenterology department,gynecology and operating room etc. *Bone tissue biopsy,spine pedicle screw implantation,long tubal bone marrow nail fixation and hand,foot fracture surgery with screw fixation. Precise imaging and Perfect visualization *Digital High frequency X-ray generator with micro-focus improve resolution and sharpness. *Intraoperative 3D imaging enables intraoperative revisions and evaluation and replaces postoperative CT control. *High frequency technology generator assures the best image in every operating condition along with reduced patient dose and extended x-ray tube lifetime.
1 x Used Hitachi ZX130LCN-6 Excavator. Year of Manufacture: 2018. Specification: 14,400kg, Hydraulic Quick Coupler, Auxiliary Line, Boom & Dipper Check Valves, A/C, Heated Seat, Good Undercarriage Approximately 70% good. EPA & CE Machine. Working Hours: 5,900. Price: Euro 38,500 GBP ex works United Kingdom. Machine Location: West Yorkshire, United Kingdom Origin: The Netherlands, European Union. Minimum Order: 1 Unit Available. Shipping Terms: Ex Works United Kingdom. Price is Ex Works United Kingdom. We are happy to provide transportation & Shipping Prices should you require this. Payment Terms: 100% TT Before Shipping
Peripheral angiography by chinese c-arm system plx7000b Usage of good quality c arm x ray machine plx7000b 6.0kw diagnostic mobile c arm x-ray machine plx7000b is wildly used in department of orthopedics, department of general surgery, orthopedics, urology surgery, spine surgery, abdominal surgery, department of pain treatment, cardiology, gastroenterology, gynecology, operating room, etc. Features of c-arm mobile digital x-ray machine plx7000b 1 .High-power, micro-focus and high-frequency generator optimize digital images. 2 .Intelligent control of exposure makes low dose. 3 .Many operating modes meet various clinical needs. 4 .Muti-leaf and vertical light control reduces soft x-ray and the skin dose effectively. 5 .Imported well-known image intensifier and full-digital ccd camera provide high-quality and high-resolution images. 6 .Dual high-resolution lcd monitors assure image quality. 7 .The powerful digital graphic workstation supports dicom 3.0, the registration of worklist and manual registration. 8 .Workstation has the function of high-capacity digital storage. Fluoroscopy and digital spot film are stored in lossless digital format. It has powerful processing capabilities like edge enhancement, gamma correction, multiple images, movie playback, window width/level, template experts, burn, etc. 9.Four-d electric motion control, accurate positioning, flexible and comfortable control, large frame design provides lager diagnostic spaces and comfortable surgical Environment. New design and new ideas brings superior experience. 10. Two panels of human graphical lcd touch screen provide intelligent and convenient operation. Dual motion control system and double foot brake make this machine greatly meet the demands of clinical operations.
Specifications: Tube Voltage): 60kV Tube Current: 1mA Exposure Time: 0.02~2S Tube Focus: 0.3*0.3mm Frequency: 30kHz Battery: DC14.8V 6400mA Rated Power: 60VA Charger Input: AC100V-240V±10% Charger Output:DC16.8V Weight:2.2kg Size:138*165*185mm The distance from skin to cone: 130mm
PLX7000B High Frequency Mobile C-arm System Make your diagnose More accurate location: Products> Surgical C-arm System Introduce 丨 Pictrue 丨 Video Introduce Features & Benefits Make your diagnose More accurate High-frequency generator deliver the power you need for all the typical applications in spine surgery, orthopedics, traumatology, urology and pain management. Unique design of large thermal capacity with advanced heat dissipation technology, allows for clear images, even for long or repeated procedures. High-resolution CCD camera with image matrix, over shades of gray, realizes more accurate diagnose. Reduce the X-ray radiation to the minimum Short, sharp pulses for clear images and the radiation exposure for the operators and patients can be reduced to a minimum. Motorized iris collimator with multi-leaf, supports high accuracy for selected x-ray field size. Crosshair overlay corresponding with laser light, designed for easily checkpoint location before operation, avoiding unnecessary exposure. Professional remote controller for exposure, allows operators retreating to X-ray exposure. Professional storage system for single and continuous images, reducing the repeatability of the exposure. Perfect Digital Image Chain Advanced functions of Images optimi-zation, strengthen module, real-time displaying the clear clinical images. Professional working station has more image post-processing functions such as the image W/L adjustment, region of interest balance, GAMMA correction, flip, noise reduction, smoothing, sharpening etc. Two monochrome lat-screen monitors clearly visualize the smallest anatomical details. Intelligent control system make the operation more efficient and easier than ever before Hand controller on C-arm stand: control the mechanical and collimator movement, improve your workflow even you are away from the unit. Hand controller on the work station trolley: select the mode of fluoroscopy. Synchronized dual touch-screen panels mounted on C-arm stand, with intuitive user interface and APR parameters setting, make the exposure control at your hand all the time. Double rotatable flat-screen monitors on the trolley, clearly visualize the smallest anatomical details even at an angle. The wide opening and depth of the arc make for precise alignment with minimum interference with the operating area.
100 mA, 100 KVP Mobile X-ray Machine 100mA, 100 KVP, Mobile X-ray Machine for Radiography only Electronic Timer Electronic Overload Protection Device Stationary Anode X-ray Tube : BEL or Imported Collimator Counter Balanced Mobile Stand Suitable for Bed Side X-rays
We're a leading XRay machine and accessories manufacturer company with over 29 years of experience and global presence and distributor network in 7 different countries. We have Line Frequency & High Frequency, APR X-Ray Machine, Dental X-Ray Machine, Mobile 100MA X-Ray Machine, 300MA X-Ray Machine, 500MA XRay Machine, Vertical Bucky, Multi-Position Bucky Table, 4 & 2 Way Floating Bucky Table Etc Beside new machines, we offer complete modification & repairing of any brand XRay machines, Rotating Anode Tube Head, HT 100MA, 300MA, 500MA Etc
Power Output 5.0KW x ray machine Main Inverter frequency 40 KHz X-ray Tube of radiography machine fixed anode focus: 1.5 (X-ray tube for high frequency) Power Supply 220V�±10% 50Hz Inner-resistance â?¤1.0�© Operation Method Wire/wireless control mobile x-ray machine safety mobile x ray machine cost mobile x ray machine price
2.5kw high frequency portable X-ray machines PLX101 x ray tube Fixed Anode Power Output of x ray machine 2.5kW Frequency 25kHz Tube voltage 40~100kV Power Supply 220V�±10%, 50kHZ Operation Method Wire/ Wireless control price list of x-ray machine price of 500ma x-ray machine price of medical x ray machine
X-ray machine Technical parameter 1. The numbers of x-ray tubes used in the product are also used as product number and x-ray generator (bulb tube head) number. 2. The current and voltage of x-ray tubes are fixed in three groups, they are: X exposure voltageú¿kvpú¬ 60 65 70 X-ray currentú¿maú¬ 0.50 0.85 1.10 3. When adding up voltage, total current is less than 2a and total power is 500w 4. Drain current and earth resistance are in accordant with the stipulates in gb9706.1 5. The three groups of voltage (60kvíó65kvíó70kv) are adjustable. 6ú«wireless remote control in any angles within 10 meters part form the control box 7. The parameter of x-ray generator (bulb tube head) 7.1. The parameter of x-ray tubes A. Focus index: 0.3í-0.3mm2 Bú«the voltage of the-highest-voltage generator: 90kv C. The highest inverse peak voltage: 90kv D. Filament characteristic: vf=5ví+0.5vú¼if=3a E. Target surface obliquity: 12íp F. The cooling manner of bulb tube head: oil immersion 8.7.2 the parameter of x-ray generator (bulb tube head): A. Focus-skin distance: 200mm B. The thickness of filter-ray film: more than 1.5mmal C. The leakage rate of x-ray: no more than 0.002mgy/h (no. 29.204.3 in gb9706.12 prescript that the leakage rate of x-ray is no more than 0.25mgy/h) D. The manner of limiting beam: using planigraphic device
Technical parameter 1. The numbers of x-ray tubes used in the product are also used as product numbers and x-ray generator (bulb tube head) numbers. 2. The current and voltage of x-ray tubes are fixed in three groups, they are: X exposure voltage (kvp) 60 65 70 X-ray current (ma) 0.50 0.85 1.10 3. When adding up voltage, total current is less than 2a and total power is 500w 4. Drain current and earth resistance are in accordant with the stipulates in gb9706.1 5. The three groups of voltage (60kv, 65kv, 70kv) are adjustable. 6. Wireless remote control in any angles within 10 meters part form the control box 7. The parameter of x-ray generator (bulb tube head) 7.1. The parameter of x-ray tubes A. Focus index: 0.3í-0.3mm2 B. The voltage of the-highest-voltage generator: 90kv C. The highest inverse peak voltage: 90kv D. Filament characteristic: vf=5ví+0.5v, if=3a E. Target surface obliquity: 12íp F. The cooling manner of bulb tube head: oil immersion 7.2 the parameter of x-ray generator (bulb tube head): A. Focus-skin distance: 200mm B. The thickness of filter-ray film: more than 1.5mmal C. The leakage rate of x-ray: no more than 0.002mgy/h (no. 29.204.3 in gb9706.12 prescript that the leakage rate of x-ray is no more than 0.25mgy/h) D. The manner of limiting beam: using planigraphic device
100 mA Mobile x-ray machine. very good image quality. built in stabilizer. works on 220v AC.
Tube stand (xts-01) Type : floor-to-ceiling rail Distance of longitudinal travel : 2550mm Distance of vertical travel : 1600mm Rotation of x-ray tube : ±180° Lock system : electromagnetic lock by manual Weight : 170kg Ceiling (xce-01, option) Type : ceiling rail Distance of longitudinal travel : 2800mm Distance of vertical travel : 1200mm Rotation of x-ray tube : ±180° Lock system : electromagnetic lock by manual Weight : 130kg Bucky stand (xbs-01, option) Type : vertical travel Distance of vertical travel : 120mm ~ 1780mm X-ray grid : grid ratio of 8:1, 103 line/inch Front plate to film distance : 50mm Weight : 105kg 4way type bucky table (xbt4-01) Type : 4way travel Longitudinal distance of tabletop sliding : 420±5mm Lateral distance of tabletop sliding : 120±5mm Tabletop to floor distance : 665mm X-ray grid : grid ratio of 8:1, 103line/inch Dimensions : 2000l x 750w x 665h (mm) Weight : 150kg 6way type bucky table (xbt6-01, option) Type : 6way travel Drive type : electric motor drive X-ray grid : grid ratio of 8:1, 103line/inch Longitudinal distance of tabletop sliding : 420±5mm Lateral distance of tabletop sliding : 120±5mm Vertical distance of tabletop : 300±5mm Tabletop to floor distance : 689(880)mm Dimensions : 2000l x 750w x 680(880)h (mm) Weight : 170kg High voltage cable (hvc-6/8) Length : 6m/8m Maximum voltage : dc 75kv The number of core line : 3 lines
NDT X ray equipment is used for inspect the inner fault of the material. It adopts radiography theory to make the image on the film, in order to evaluate the work piece. Features of X Ray Generator: Adopt high temperature installation technology and high pure degree aluminum radiator to improve 30% heat radiation. Portable design, light weight and easy operation. SF6 gas insulator, grounded-anode design to keep the operator safety. Strictly follow 1:1 work and rest radio, eliminating the disoperation. Good HV coil made by imported enamel wire in the generator to improve the power. Glass tube Panoramic XXH-1005 Power(KW) >1.0 , Beam Angle: 360*25 ,Max.Penetration A3 steel (mm) : 6 XXH-1605 Power(KW) >1.5 , Beam Angle: 360*25 ,Max.Penetration A3 steel (mm) : 18 XXH-2005 Power(KW) >2.0 , Beam Angle: 360*25 , Max.Penetration A3 steel (mm) : 26 XXH-2505 Power(KW) >2.5 , Beam Angle: 360*25 , Max.Penetration A3 steel (mm) : 36 XXH-3005 Power(KW) >3.0 , Beam Angle: 360*25 ,Max.Penetration A3 steel (mm) : 46 XXH-3505 Power(KW) >3.5 , Beam Angle: 360*25 , Max.Penetration A3 steel (mm) : 56 Glass tube Directional XXQ-1005 Power(KW) >1.0 , Beam Angle: 40 , Max.Penetration A3 steel (mm) : 8 XXQ-1605 Power(KW) >1.5 , Beam Angle: 40 , Max.Penetration A3 steel (mm) : 20 XXQ-2005 Power(KW) >2.0 , Beam Angle: 40 , Max.Penetration A3 steel (mm) :29 XXQ-2505 Power(KW) >2.5 , Beam Angle: 40 , Max.Penetration A3 steel (mm) : 39 XXQ-3005 Power(KW) >3.0 , Beam Angle: 40 , Max.Penetration A3 steel (mm) : 49 XXQ-3505 Power(KW) >3.5 , Beam Angle: 40 , Max.Penetration A3 steel (mm) : 59 Ceramic tube directional XXG-1605 Power(KW) >1.5 , Beam Angle: 40 , Max.Penetration A3 steel (mm) : 20 XXG-2005 Power(KW) >2.0 , Beam Angle: 40, Max.Penetration A3 steel (mm) : 29 XXG-2505 Power(KW) >2.5 , Beam Angle: 40 , Max.Penetration A3 steel (mm) : 39 XXG-3005 Power(KW) >3.0 , Beam Angle: 40 , Max.Penetration A3 steel (mm) : 49 XXG-3505 Power(KW) >3.5 , Beam Angle: 40°, Max.Penetration A3 steel (mm) : 59 wooden case 80KG
APR Model with Digital Display and Feather Touch Panel. Suitable for all type of X-Rays Mobile as well as Fixed Horizontal Bucky Table / Floating Table Top Table Exposure Counter Stationary as well as Rotating Anode. Counter Balanced and Spring Balanced Mechanical. One Unit, Approx Weight 300Kg.
PLX101 Series High Frequency Mobile X-ray Equipment PLX101/101A/101C Rocker safety lock design, make your operate much safer High quality x-ray monoblock assures more details, less dose Symmetrical adjustable collimator for accurate positioning and better exposure protection Aviation aluminum connectors, connection reliable, more safety Advanced dislocation braking system, flexible movement, flexible braking Multifunctional cassette storage box design Features Our high frequency technology assures the best image in every operating condition Along with reduced patient dose and extended x-ray tube life time The generator provide the right amount of penetration, reducing exposure times and retakes. The parameter can be adjusted by the kV and mAs. Multiple security protect function such as over-voltage, over-current. 50 preset exposure programs allow extensive possibilities to optimize the exposure and processing parameters according to your preferences. Fault automatic protection setting and fault alarming display Parameters are automatically storage when power cut off. Adopt rotating beam limiting device to adjust the X-ray field and angle freely. Adopt manual controller and remote controller to do exposure. Optional: PLXF152 mobile table for high frequency mobile X-ray equipment. PLX101D is equipped with built-in battery, can take 200 films when full charged. Rocker can move up and down, automatically balance High quality X-ray monoblock can rotate in ±90 Options PLXF152 Mobile Bed For Mobile X-ray Machine Size: 2000 X 700X 500mm Range of grid box movement 1210mm Size of grid box: 430X 430(17 X 17) Bucky Stand Height: 1770mm Vertical movement range: 470-1470mm Grid density: 103L/inch Grid radio: 10:1 Focus distance: 150cm Maximum grid box: 17 X 17 Technical Parameters
Tunnel size:650(w)*500(h)mm Conveyor speed: 0.22m/s Conveyor max load: 170kg Wire resolution: 32awg to 40awg Spatial resolution: horizontal:1.3 or 1.0mm, vertical: 1.3 or 1.0mm, Penetration: 30 to 32mm steel Film safety: guarantee iso1600 film X-ray leakage: