Electrolyte analyzer series, auto hematology analyzer series, automatic elisa plate washer series, semi-auto chemistry analyzer series, b/w ultrasound consumables, patient monitor, fetal monitor, handheld fetal doppler.OEM
Medical products used in hospitals and clinics, such as EKG machine, multiparameter patient monitor, defibrillator, ultrasound scanner, pulse oximeter, fetal doppler, fetal monitor, blood pressure, visual stethoscope.
Test Method:Dispersion light nephelometric analysis Test Principle:The highest point on first order differentiation,Percentage analysis Zero point correction:auto track the zero point,eliminate the interference of sample and reagent Wavelength:470nm Light Source:Cold Lamp with high brightness and long lifetime Detector:unique Dispersion light detector with high sensitivity and repeatability,immunized the effect on result of jaundice¡¢hemolysis¡¢chyle and turbidity on plasma Test Channel:each channel is independent,one or more,same or different items can be tested Simultaneously Incubator:Provide reagent and sample with stable incubator, Incubator Temperature:37¡À0.2oC Measure trigger:Auto trigger the measurement through configured pipette Item modify:easy to add or edit items,easy to set the items parameters Calibration:single-point calibration;multipoint calibration;auto store and match with calibration curve Quality control:auto draw the quality figure Reagent:open reagent system Reagent volume:40 Sample volume: 40 Memory:Save more than 10000 samples results,and auto recovering the results when power is off during working Repeatability:CV¡Ü5% Calculative item:S¡¢%¡¢PTR¡¢INR,Fib can be get through PT,This leads to lower the cost of reagent Printer:Inner thermal printer,can be connected to external printer Information edit:easy to input and edit the detail information of patients Interface:RS-232 serial port,can be connected to external printer Working Environment:Temperature:10 oC~30 oC Humidity: ¡Ü70%RH Voltage:85-264V,Auto adapt according to the input voltage Power: ¡Ü80W Quality System:Recognized by CE,TUV and CMD Test Items PT AT-¢ó APTT Protein-S TT Protein-C Fib LA RepT Hep VT. 260mm*257mm*133mm 3.6kg.
Features: 1.English menu display 2.Lead off/on signal by indicator light 3.Selectable multi-recording modes:3 channels,3 channels + rhythm 60 sec compressible: select simultaneously acquisition of 12-lead ECG signals 4.Automatic diagnosis and analysis 5.Save the half record paper and the half record time 6.The body check mode can record the patient ECG 15 seconds/each 7.Thermal printer (dot array),40 dot/mm,precise waveform 8.Rechargable battery pack 9.Hidden handle. Specifications: Acquisition mode: simultaneous 12 leads Operating mode: auto/manual Recording format: auto/manual/simultaneously 60 sec compressible LCD display: operation mode/ Status, HR Input Condition: against defibrillation Input impedance: >50MQ Patient Leakage Current: 3.2 s CMRR: > 100dB Filter:50Hz or 60 Hz (-20dB) prift(0.5Hz-3dB) Sensitivity Option: Auto,2.5,5,10,20,40mm/mv=2% Resist to polarization voltage:=500mV Electrical noise level:
1.Notebook style,special backpack,lightweight and convient 2.Intelligent ports, 5 available different probes 3.Portable and trolley optional 4.7 segment intelligent STC adjustment, high resolution images 5.Low radiative 15 inch TFT LCD display 6.Great capacity of cineloop ,high definition dynamic images 7.Chinese and english operation interface. Specifications: Scanning Mode: wide frequency electronic Convex/ Linear Display Mode: B, B+B, B+M, M, 4B, 8B Scanning Depth: 220 mm Gray Scales Transformation: gamma correction Image Magnification: 1.0, 1.2, 1.5, 2.0 Monitor: 15 inch TFT LCD display Image Conversion: up and down, left and right, black and white Focusing: variable aperture for section 1,2,3,and 4 available Electronic Focuses: 4 sector dynamic ( Random Combination ) Probe FRE. Support: Convex, Linear, Micro convex, Vaginal, Rectum Resolution: Lateral less than 2mm, Axial less than 1mm Body Marks: 24 Obstetric calculation: BPD, FL, CRL, GS, HC, AD AC, and display fetus age, fetus weight, expected birth date, heart rate, slope ratio, period. Measurement: Distance, Circumference, area, heart rate, EDD, etc. Pseudo-color: 8 available colors Display: Date, Time, Name, Sex, Age, Hospital, Obstetric list, annotation, edit menu, etc. Video Output: PAL, VGA Size:280mmX240mmX210mm Net Weight: 6.5Kg.
Features: 1. Laptop design 2. 3. 8 TGC controls 4. High-quality images 5. Broadband multi-frequency transducers 6. Leading digital technologies: Digital beam forming, Real time dynamic filtering, Dynamic frequency scanning, Real time dynamic aperture 6. Cineloop 7. Two USB ports 8. Two probe connectors 9. Pseudo colors. Technical Specifications: Display: 15 inches high-resolution LCD Scanning Mode: Electronic convex array, Electronic linear array Display Mode: B, B+B, B+M, M Magnification: X0.8,X1.0,X1.2,X1.3,X1.5,X1.6,X1.8,X2.0 Gray Scales: 256 shades Y adgustment: A,B,C,D,E,F,G,H Resolution: Horizontal less than 2mm, Vertical less than 1mm Geometrical Precision: less than 5% Blind Area: less than 3mm TGC: 8 section TGC adjustment Pseudo Colors: Yes Display Depth: 240mm and depth could be increased Image Polarity: Left/right, Positive/negative and up/down Cineloop: Successive 256 frames Output Lnterface: Three output interface 1 VGA and 2 PAL video signal output Power Supply Range: AC 110V 60Hz, 220V 50Hz Net Weight: 6.5Kg Size: 280mmX240mmX210mm.
Features: 1.English menu display; 2.Lead off/on signal by indicator light; 3.Selectable multi-recording modes:single channel, 2 channels,2 channels + rhythm; 60 sec compressible: select simultaneously acquisition of 12-lead ECG signals; 4.Save the half record paper and the half record time; 5.The body check mode can record the patient ECG 15 seconds/each; 6.Thermal printer (dot array),40 dot/mm,precise waveform; 7.Rechargable battery pack; 8.Hidden handle. Specifications: Lead: Standard 12 leads Acquisition mode: simultaneous 12 leads Operating mode: auto/manual Recording format: auto/manual/simultaneously 60 sec compressible LCD display: operation mode/ Status,HR Input Condition: against defibrillation Input impedance: >50MQ Patient Leakage Current: 3.2 s CMRR: > 100dB Filter:50Hz or 60 Hz (-20dB) prift(0.5Hz-3dB) Sensitivity Option: Auto,2.5,5,10,20,40mm/ mv=2% Resist to polarization voltage:=500mV Electrical noise level:
Ge-utah ibp cable , (original no:7000078-001) 3.8m, Grey or white cable available, Rect.11pin >utah-4pin Compatible with ge solar, dash, eagle, tram .
Product operation scope : The fingertip oximeter can be used to measure human hemoglobin saturation and heart beat through finger. The product is suitable for use in family, hospital (including clinical use internist/surgery, anesthesia, pediatrics, intensivecare and etc), oxygen bar, social medical organizations, physical care in sports (it can be used before or after sports. Continually monitoring is not commended). Technical parameters: Display format: led spo2:35-99% in two-digit 7-segment digital;pulse ratio:30-240bpm in 3-digit 7-segment digital;pulse wave: 6-segment bargraph;battery voltage low indication: led signals.-fff Power requirements: two aaa size 1.5v alkali battery;ffff Power consumption: less than 40ma.-f Resolution: f+1% for spo2 and f+1 bpm for pulse ratio. Measurement accuracy: f+2% in stage of 70%-99% spo2 and meaningless when stage being smaller than 70%. -+2 bpm for pulse ratio. Measurement performance in weak filling condition: oxyhemoglobin and pulse value can be shown correctly when pulse-filling ratio is 0.5%. Interference resistance capacity against ambient light: deviation is smaller than f+1% between value of oxyhemoglobin measured in natural lighting indoor condition and present lighting sources and that measured in dark room. Product properties : Operation of the product is simple and convenient.-fff The product is small in volume, light in weight (total weight is about 50g including batteries) and convenient in carrying.-fff Power consumption of the product is low and the two originally equipped two aaa batteries can be operated continuously for 30 hours.-fff Low voltage warning will be indicated in visual window when battery voltage is so low that normal operation of the oximeter might be influenced.-fff The product will automatically be powered off when no signal is in the product for more than 8 seconds. Suitable for adult and pediatric patient 0.15kg/pc
Ultrasonic vascular Doppler, BF series fetal Doppler, BFM series fetal/maternal monitor, BD series disposable syringe destroyer, ECG series, BEU series ultrasound scanners, BPM series multi-parameter patient monitor.
Ultrasonic fetal doppler, BV series ultrasonic vascular doppler, BFM series fetal, maternal monitor, BPM series multi-parameter patient monitor, BD series disposable syringe destroyer, ECG series, BEU series ultrasound scanners, BFW series medical fluid infusion.
Needle destroyer features: Electrodes made from peculiar heat-resisting material can work for long time, too low working voltage7vinsures the operators safety. After melting the needle, then meld the syringe tube, all work finish in one time, easy and safe. The controlling curcuit desgned for safety insures the operators safety. Very simple operation Empty the liquid in the syringe during use, then insert the needly into hole to melt the needly first, and then move toward the left cutting hilt. (refer to s 7, 8). It needs totally 6 seconds to destroy the syringe and needle. Convenient to carry, work with ac. Portable desisn can be directly moved, model bd-310 can directly use ac220, convenient to supply electricity.
Alkaline water ionizer, detox foot spa, pulse oximeter, fetal doppler, electric toothbrush, blood pressure monitor, compressor nebulizer, massager.
Integrated with SPO2 probe and processing display module Can be used in: hospital, home, community medical treatment, sports healthcare, etc. Can measure SPO2 and PR accurately SPO2 and PR display, bargraph display Battery voltage low indication Low power consumption; shut off automatically when no signal Small volume(57(L) ¡Á 33(W) ¡Á32(H) mm)light,convenient to carry.
1.Clean surface of the fingertip oximeter before it is used in diagnosis for patients 2.Remove the batteries inside the battery cassette if the oximeter will not be operated for a long time 3.It is best to preserve the product in a place whtere ambient temperatures 10~40¡æ(14~104¡ãf£©and humidity is 10%~80% 4.It is best to storage the product in a place where ambient temperatures -20~70¡æ and humidity is
Massager, exercise machine, hand held massager, massage cushion, mini massager.
Metal detectors- walk thru, hand held, body scanners.
Hand held fiber microscope, visual fault locator, cable continuity tester.
Walk through metal detector, hand held metal detector.
You can diagnose and repair simple fiber link problems with our visual fault locator-cable continuity tester. The laser-powered cable continuity tester locates fibers, verifies continuity and polarity. This cable continuity tester helps find breaks in cables, connectors and splices. Continuous and flashing modes make for easier identification. Compatible with 2.5mm and 1.25mm connectors for easy connection. Ruggedly constructed for demanding field-testing. Long battery life for hours of use.