It is used for the testing of IPX7, it also provide water and electrical automatic control for IPX1~6` waterproofing test. Parameters: 1. Suitable for IPX1-6 water proof and UL dripping water?IPX7 water immersion test and automatic control of the whole waterproof test system; 2. Water supply method: constant temperature water supply, constant flow water supply, constant pressure water supply. 3. Water supply control process: After user preset the water flow value and water pressure value on the touch screen, electronic meters or digital pressure gauge real-time monitor the current values, read the values into PLC through the data conversion, then automatically adjust the rotational speed of pump through the frequency converter. 4. There are large flow and small flow two ways water supply. 5. Large flow water supply: (a) It is applicable to IPX5~IPX6 strong water spray test and water injection of IPX8 (b) Flow range: 10~100L/min (c) Flow accuracy: ±0.5L/min (d) Flowmeter: Turbine flowmeter (e) Water pump: Stainless steel centrifugal pump 6. Small flow water supply: (a)It is applicable to IPX1,IPX2,IPX3,IPX4 and UL waterproof test (b)Flow range: 1~10L/min (c)Flow accuracy: ±0.5L/min Flowmeter: Turbine flowmeter (d)Water pump: Stainless steel centrifugal pump (e)Pressure range: 0.1-3Kg/cm²; (f)Pressure digital display: Adopt digital pressure gauge; 7. Water storage tank: (a)It is applicable to water storage of IPX5~IPX6 strong water spray test,water injection of IPX8, IPX7 immersion (b)Volume: 500L (c)Dimension: L600mmXW660mmXH1400mm (d)Observation window: toughened glass window (e)Observation window dimension: W200mmXH1250mm (f)Depth gauge: stainless steel (g)Depth gauge height: 1300mm, accuracy 1mm (h)Liquid level control: float switch + overflow pipe 8. Control Cabinet: (a)Flow detection: flow signal feedback through electronic flowmeter (b)Flow setting: set on touch screen (c)Temperature detection: PID (d)Controller: Mitsubishi PLC (e)Friendly interface: 7 inch, color touch screen (f)Control function: constant flow water supply, constant pressure water supply,vertical drop rain motion control, oscillating tube rain motion control, rotation table motion control and test time control. (g)Protection function: leakage protection, overload protection, short circuit protection. 9. Water supply pipeline: water supply of this equipment using PVC hose, it is assigned to each device according to the site layout , and controlled by the electromagnetic water valve. 10. Install the drainage valve on the water supply pipeline, it will automatic discharge the water after the test is completed 11. Filter: stainless steel shell, fine filter element. 12. Machine body material: aluminum alloy profile. 13. Appearance size(WXDXH):1400X750X1600mm;
St907v7.0 industrial pda Android 4.4/4 core/ 4g/wifi/bt/gps/ip65 St907v7.0 mobile android pda terminal is portable and digital data acquisition mobile terminal with the functions of 1d /2d barcode scanning, uhf rfid reader, gps positioning, wifi, bluetooth, camera and so on. Nfc rfid rearder is available with 14443a, 14443b and and iso15693 protocol , uhf rfid 860mhz to 960mhz america standard and european standard. It can be widely used in the area of industrial, industrial manufacturing, logistics management, assets management and routing inspection, motorcycle race, person access control system, electric power inspection domain, warehouse management, animal management, metal management and etc. Your best choice of industrial pda, direct deal from factory. St907v7.0 android4.4 industrial pda with ip65 certificate, 1d/2d barcode scanner pdf417 barcode, qr code rfid reader nfc uhf hf 13.56mhz., lf132.4k hdx/fdx , lf125khz, fingerprinter reader widly use in logistic, power, police, warehourse management, motor race, medical and so on .
Batterytypelithium-ion polymer battery, pluggable, dimension:21.8*92.3*9.5mmstandard:1pcs optional:2pcs Capacity3.7v/10000mah na Endurance8hrs(default 50% volumn, default200nit, play 1080p hd video)na System hardware configuration Typedetailsdescription Cputypeintel baytrail-t(quad-core ), z3735f3735g Speed1.33ghz-1.86ghzna Gputypeintel hd graphic(gen7)na Ramddr3l2gb 1gb Rom emmc32gb 8g/16g/64g/128g G_sensorbuilt-ingravity acceleration sensorna Network connections Typedetailsdescriptions Wifiwifi modulewifi 802.11(a/b/g/n) frequency 2.4g+5.8g dual band wifi, na Bluetoothbuilt-inbt4.0 (bleclass1 transmission distance:10mna 3gbuilt-inic:h350-a50-10 bands:wcdma(900/2100mhz) gsm(900/1800mhz), hsdpa 21mbps, hsupa 5.76 21mbpsh350-a30-10 wcdma(900/2100mhz)hsdpa 7.2mbps, hsupa 5.76 21mbps H350-b50-10 wcdma(850/1900mhz)hsdpa 21mbps, hsupa 5.76 21mbps H350-b30-10 wcdma(850/1900mhz)hsdpa 7.2mbps, hsupa 5.76 21mbps 4gbuilt-inna"ic:l810 bands:5modes11frequency (lte Fdd/lte tdd/wcdma/td-scdma/gsm)" Gpsbuilt-insupport :glonass, qzss, gps;capture sensitivity: -160 dbm;cool start time:
?equipment model and name Csl-y impact specimen gap hydraulic broaching machine ? equipment usage Impact specimen notch broaching machine is the dedicated and affiliated equipment with metallic pendulum impact testing machine, the machine adopts hydraulic drive, electric control the rise and fall of broach, broach lifting speed can be adjusted, adopting the lubricating oil to lubricate blade mouth parts at the same time, to ensure the sample accords with a requirement gap size and surface finish.The machine due to the use of a forming principle, the machining gap of good identity. Broach manufactured high-quality high-speed w18cr4v steel alloy, and its high hardness, good wear resistance, long service life, per knife can be processed more than 20000 samples. ? applicable standard Gb/t229-2007« metal material charpy pendulum impact test method»; Astm e23-02a«metal material gap specimen standard impact test method»; Iso148-2008«metallic materials-charpy pendulum impact test»; Din 50 115-1991«metal material impact test special sample size and fracture judge» Iv main technical parameters Sample notch type U type(u2, u3, u5), v type(v2) Processing sample size 10×10(7.5 or 5)×55mm Broach hardness =hrc65 Installed broach quantity 2 Cutting speed 2.5m/min ( can adjust) System pressure 2.5mpa Hysraulic oil storage 25l Broach stroke 340mm(u2, v2), 390mm(u5) Broach materials W18cv4v Motor power 370w Dimensions 480mm×660mm×1200mm (l×w×h) Weight 200kg V standard configuration 1.Host one 2.V2 broach one 3.U2 broach one Vi optional accessories 1. U3 broach 2. U5 broach
It is suitable for all types of portable lamps and similar electrical appliances products for mechanical stability test, the test sample is placed on countertops, to assess its mechanical stability through different tilt angles. Working condition: Environment:0¡æ¡«+40¡æ;Working power supply:220V¡¨¤10%,50Hz Technical index: 1.Tilt angle:0-30¡ãstepless adjustable,electric control,encoders intelligent digital display; equipped with angle measuring instrument calibration, easy to operate, high accuracy angle,precision ¡¨¤ 0.5 ¡ã. 2.The maximum weight load:50kg,(load can be improved as per customer requirements)steel plate surface is treated by painting; 3.Motor speed: 0.50r/min (frequency control for optional),there are reliable earthing contact and power plug connector on the test bench of accessible metal surface; 4.Table diameter:800mm; 5.The test bench with stable whole structure,and beautiful appearance. Table diameter:800mm
NK series of pointer force gauge (pull force gauge) are portable testing instruments of easy operation, high precision, easy portability, peak value maintenance, and simultaneous display of two scales. The new substitutes of old gauge, such as pull force load testing, pull and push force testing and destructive testing, are also widely used in high-voltage and low-voltage electric appliance, electronics, hardware lock-making, automobile accessories, lighters and igniting devices, pen-making, light industry, constructions, textiles, mechanical engineering, and IT field.
Iec60335 temperature black test corner To measure the temperatures in the base or in the fixing surfaces for applicances and luminaires in operation according to iec60335-1/2006-09 clause 11.2 and 11.3. Can be used to the temperature test of all kinds of electronic products supply, in conformity with the standards requirement of the environmental conditions. Advantages Test corner boards are "stand alone basic" and could be easily combined into a test corner by using some track. Packed with strong wooden case
1.Product description Six-channel current output, six-channel voltage output, six-channel share of dc current, six-channel dc voltage output, eight pairs of binary input, four pairs of binary output. 2.Features Integration in the host crystal 8.4 inches true color, light weight and easy to carry Built-in high-speed high-performance industrial computer, embedded operating system, running a stable and reliable also be connected pc testing Panel embedded user-friendly buttons can also be an external keyboard, mouse High-precision dac to 12 road, simultaneous output to ensure that waveform fitting of high precision, good linearity Matching electromagnetic compatibility components, can improve on-site anti-electromagnetic interference, protection devices can be connected electromagnetic compatibility tests Analog output of the front panel, switch the amount of terminal design in the upper cover, all the wiring does not affect the operation of the panels and test parameters of the surveillance Exterior appearance of cabinetImported electromagnetic compatible cabinet, which is made of high-grade all aluminum alloy extruded section and has fine appearance, is selected. Dimension of cabinet: length¡ñwidth¡ñheight¡@360mm ¡ñ195mm ¡ñ365mm Weight of cabinetWeight of host machine ¡@¡@¡@¡@¡@¡@¡@¡@¡@ ¡@16.6kg
Features Troubleshoot real-time: Analyze the trends using the cursors and zoom tools-even while background recording continues. Automatic Transient Mode: Capture 200 kHz waveform data on all phases simultaneously up to 6 kV Measure all three phases and neutral: With included four current probes System-Monitor: Up to ten power quality parameters on one screen according to EN50160 power quality standard View graphs and generate reports: With included analysis software Logger function: Configure for any test condition with memory for over 400 parameters at user defined intervals. Mains signaling: Measure interference from ripple control signals at specific frequencies Inrush mode: For troubleshooting nuisance circuit breaker tripping. AutoTrend: Every measurement you see is always automatically recorded, without any setup. Fully Class-A compliant: Conduct tests according to the stringent international IEC 61000-4-30 Class-A standard. Battery Life: Seven hours operating time per charge on NiMH battery pack High safety rating: 600 V CAT IV/1000 V CAT III rated for use at the service entrance • Comparing to online power quality analyzer, E6000 handheld type with small size, light weight, easy for the engineer to carry and carry out to survey work whenever and wherever. • Easy to wiring • It can operate directly to the line under test under the circumstances that the Power Grid without interrupt. • Multi-range current switching • based on actual demand, the different range of current clamp can be replaced to improve measurement accuracy. Applications Frontline troubleshooting - quickly diagnose problems on-screen to get your operation back online Predictive maintenance - detect and prevent power quality issues before they cause downtime Quality of service compliance - validate incoming power quality at the service entrance Long-term analysis - uncover hard-to-find or intermittent issues Load studies - verify electrical system capacity before adding loads Energy assessments - quantify energy consumption before and after improvements to justify energy saving devices. Specifications Measurement Items Be measured Type of measurement RMS Voltage Voltage RMS Current Current Frequency Deviation Frequency Three-phase Unblanced Voltage, Current Voltage fluctuations Voltage Flicker Voltage Harmonics and inter-harmonics, higher harmonic Voltage, current Power Active, reactive, apparent power factor Event log Transient pulse, the voltage rise, voltage sags, voltage interruption, the impact of current, frequency of abnormal Input parameter Measuring circuit 1P2W, 1P3W, 3P3W, 3P4W The fundamental frequency of the measuring circuit 50Hz/60Hz Number of input channels Voltage, current, 4 Measurement range Voltage Measurement Range: Nominal value: 100V, 230V, 400V, maximum 1000V Current measurement range: Depending on the current clamp, current clamp the output voltage signal, the maximum voltage: 10V peak Environmental security parameters Use of the environment 0 ° C to +45 ° C, humidity 90rh% Storage environment -20 ° C to +50 ° C, 95RH% humidity (non-condensing) Power input voltage +100VAC ~ +240VAC Electromagnetic Compatibility Level 3: GB / T 17626.2-2006 Electrostatic Discharge Immunity Level 3: GB / T 17626.3-2006 RF electromagnetic radiation the Immunity Level 3: GB / T 17626.4-2008 electrical fast transient burst immunity Level3: GB / T 17626.5-2008 surge (impact) Immunity Level 3: GB / T 17626.8-2006 frequency magnetic field immunity Level 3: GB / T 17626.9-1998 Pulse magnetic field immunity Level 3: GB / T 17626.12 -1998 Oscillatory waves immunity Environmental reliability GB/T 2423.1-2008 low temperature GB/T 2423.2-2008 high temperature GB/T 2423.4-2008 alternating hot and humid GB/T 2423.5-1995 impact GB/T 2423.10-2008 vibration GB/T 2423.22-2002 temperature changes Dustproof, waterproof IP20(GB 4208-93/IEC 529:1989) Security 500V/10M,2KV:GB/T 15479-1995 External interface parameters USB Device 1 The upload power quality data TF card to expand storage 1 Built-in capacity Optional, up to 8G Battery 1 4500mAh Ni-MH battery LCD 1 26 million color 5.6-inch LCD screen with a resolution of 640 * 480 Voltage and current measurement interface 8 Test voltage and current input port Frequency Measurement method 10 waveform (50Hz) the calculated frequency Display Display of a channel frequency value Measuring range / resolution 50.0000Hz/0.0001Hz Measurement bandwidth 42.5000~57.5000Hz Measurement accuracy ±0.001Hz 1/2 rms voltage 1/2 rms, current Measurement method Once every two cycle operations, a waveform operations per cycle to take 1/2 cycle Sampling Frequency 200K Measuring range / resolution 120V/0.01,230V/0.01,400V/0.01,Based on the use of current clamp Measurement accuracy 0.1% of the nominal voltage RMS voltage Measurement method 10 waveforms (50Hz) the operator Display Per channel RMS voltage Sampling Frequency 200K Measuring range / resolution 120V/0.01,230V/0.01,400V/0.01 Measurement accuracy 0.1% of the nominal voltage RMS voltage Measurement method 10 waveforms (50Hz) the operator Display Current per channel RMS Sampling Frequency 200K Measuring range / resolution Based on the use of current clamp Measurement accuracy 0.1% of the nominal voltage Harmonic voltage, harmonic current Measurement method According to IEC61000-4-7, the magnitude of the analysis window 10 cycles Window points Every 10 cycles of 5120 points Display Histograms, tables Sampling Frequency 200KHz Number of measurements 0~50 Measuring range / resolution 120V/0.01,230V/0.01,400V/0.01 Measurement accuracy voltage harmonics greater than 1% of the nominal value: Error is less than 1% rdg voltage harmonics less than 1% of the nominal value:Error is less than 0.05% rdg the nominal voltage current harmonics greater than 3% of the nominal value: the error is less than 1% edg current harmonics is less than 3% of the nominal value:Error is less than 0.05% of the nominal voltage interharmonic voltage interharmonic current Measurement method According to IEC61000-4-7, the magnitude of the analysis window 10 cycles Window points Every 10 cycles of 5120 points Display Form Sampling Frequency 200KHz Number of measurements 1~16 Measuring range / resolution 120V/0.01,230V/0.01,400V/0.01 Measurement accuracy voltage harmonics greater than 1% of the nominal value: Error is less than 1% rdg voltage harmonics less than 1% of the nominal value:Error is less than 0.05% rdg the nominal voltage current harmonics greater than 3% of the nominal value: the error is less than 1% edg current harmonics is less than 3% of the nominal value:Error is less than 0.05% of the nominal voltage High harmonic voltage, high harmonic currents Measurement method Every 10 cycles of 5120 points Window points Every 10 cycles of 5120 points Display Form Sampling Frequency 200KHz Number of measurements 1 to 35 group Measuring range / resolution 120V/0.01,230V/0.01,400V/0.01 Measurement accuracy voltage harmonics greater than 1% of the nominal value: Error is less than 1% rdg voltage harmonics less than 1% of the nominal value:Error is less than 0.05% rdg the nominal voltage current harmonics greater than 3% of the nominal value: the error is less than 1% edg current harmonics is less than 3% of the nominal value:Error is less than 0.05% of the nominal voltage Active power, reactive power, apparent power Measurement method Active power: 10 cycles computing Apparent power: Valid values of voltage and current operations Reactive Power: apparent power, active power is calculated Display Real-time data display Sampling Frequency 200KHz Measuring range / resolution Determined based on the voltage and current range Measurement accuracy ±0.5%rdg Power Factor Measurement method Rms, current rms voltage, active power is calculated Display Real-time data display Sampling Frequency 200KHz Measuring range / resolution -1.0000~1.0000 Measurement accuracy ±1%rdg Voltage unbalance, current unbalance (negative and zero sequence) Measurement method when 3-phase 3-wire or 3-phase 4-wire, calculate by three-phase fundamental ingredients Display Voltage unbalance current imbalance Sampling Frequency 200KHz Measuring range 0.00%~100% Measurement accuracy Voltage unbalance: ± 0.5% Current imbalance: ± 0.5% Voltage fluctuations Measurement method Half-wave to calculate the mean square Display The fluctuation trends, real-time values of voltage fluctuation Sampling Frequency 200KHz Measuring range 0.00%~100% Measurement accuracy ±1% IEC Flicker Measurement Item The short flicker (PST), long flicker (Plt) Measurement method According to IEC61000-4-15 10 minutes PST continuous measurement, continuous measurement and calculation 2 hours Plt Display The flicker trends, Pst value, Plt Measuring range 0~20 Measurement accuracy ±5% The impact of current Measurement method Half-wave rms current exceeds the set value of the positive impact of current Display The impact of current waveform, the impact of the current maximum Measurement accuracy 0.10% Measurement method Temporary swell: half-wave rms voltage positive direction exceeds a set value, it is determine as Temporary swell temporary sag: Valid values are negative direction exceeds a set value, determine as temporary sag Short interruptions: half-wave RMS voltage exceeds the set value in the negative direction, the decision for an instant interrupt Display Temporary swell, sag, short interruptions waveform duration, amplitude etc. Measurement accuracy 0.10% Temporary swell, sag, short interruptions waveform duration, amplitude etc
Application It is suitable for power department, measuring department, quality control department, research units, and institutions of higher learning, and electric energy meter, power distribution terminals, power supply management, load control, power quality, reactive power compensation device and production of the enterprise and so on. Main Functions and Features To set up and take the load regulation of voltage, current, phase and frequency of the power factor; To be set to 2 ~ 128 times of the amplitude and phase harmonics, and it can be added to the base wave in every harmonic output; Voltage, current output a wide range, big power, high stability, waveform distortion degree is very small; To have strong with load ability, and take capacitive, sensibility, resistance of composite type load or load and load regulation is higher than 0.01% ; To apply the 32 bit MPU + DSP + FPGA, powerful flexible; To use hardware PID, fast response, the change of load will not cause output volatility; Industrial frequency waves as high as 50000 points a week of the wave kneading, signal output without filter, precise output waveform, the harmonic output precision, harmonic distortion degree is small; Range switching automatically; To use software calibration, simple operation, stable and reliable; To have the big screen, 320 x 240 LCD display, Chinese or English interface, operating simplely; To have perfect over-current, over-voltage, heat, a shorts-and-opens, overload protection, automatic failure detection; With RS232 interface, and PC connection; To take place machine software, it can be output through the PC software of program. Technical Data AC voltage output Range: 57.7 V / 100 V / 220 V / 380 V / 750 V, range switch automatically Adjust fineness: 0.01% RG Accuracy: RG is higher than 0.05% Stability: better than 0.01% RG / 1 min Distortion degree: better than 0.1% (not capacitive load) Output power: the rated each phase is 40 VA Full load regulation rate: less than 0.01% RG Full load regulation time: less than 1mS Temperature drift: 8 PPM / ¡æ Long-term stability: 60 PPM/year AC current output Range: 0.1/0.25 A / 0.5/1 A / 5 A / 10 A / 20 A / 50 A / 100 A, range switch automatically Adjust fineness: 0.01% RG Accuracy: RG is higher than 0.05% Stability: better than 0.01% RG / 1 min Distortion degree: better than 0.1% (not capacitive load) Output power: the rated each phase is 40 VA Full load regulation rate: less than 0.01% RG Full load regulation time: less than 1mS Temperature drift: 8 PPM / Long-term stability: 60 PPM/year Phase angle Adjusting range: 0 ~ 359.99 Resolution: 0.0 Accuracy: 0.03 Frequency Adjusting range: 40 Hz ~ 65 Hz Resolution: 0.001 Hz Accuracy: 0.002 Hz Temperature drift: 0.5 PPM / Long-term stability: 4 PPM/year Work power Single phase AC 22015% , Frequency 50/60 Hz. Volume and weight Size: 420 mm x 320 mm x 155 mm (long x width ¡Á high) weight: 12 kg Environmental conditions Working temperature: 0 ~ 40 Relative humidity: 85% Storage conditions: -30
Brief introduction 1. Fast processor Cpu is msm7627 aa and the system adopts android 4.0 ics operating system. 2. Strong protection for bad environment It can apply to the bad environment, which can resist multiple dropping impact from 1.2m high; apply to ip65 protection grade with good water-proof and dust-proof effect; durable and long life span. 3. Visible 3.5 inch lcd in the sunlight It is 3.5 inch vertical screen lcd, 480*640 high resolutions; with pressure sensitive touch screen and semi permeable tft lcd readable display. Its particular non glare and reflective technology make the work in the wild sunlight more easy and convenient. 4. The storage capacity is big and extensible Tf card supports no less than 8g cards, which can basically satisfy regular information and data storage. It adopts portable change design. There is no need to open the tester and you can remove the battery with the knob. The battery capacity is as high as 6000 mah. 5. Advanced battery installation design and strong endurance Due to the lithium battery capacity of 6000 mah and low-power design, the duration will be more than 3 days under routine operation. 6. Multi-functional module integration --the built-in fixed network test module can do adsl test, lan test and modem emulation. --5 million pixels camera makes the image data collection convenient. --support bluetooth, which is convenient provide data transmission between any compatible electronic equipment. --built-in gps module can realize the position location. --support 1d/2d red light/ laser bar codes scan. 7. Reliable process design It adopts advanced manufacturing process which is reliable and convenient to assemble. Paper carton package.
Parameters: - simulation and measurement: thermocouple signals J, K, T, R, S, B, U, L, E, N, with auto-compensation of terminal temperature, signals in thermocouple and thermostat system, resistance thermometer signals: Pt 100, Pt 500, Pt 1000, Ni 100, Cu 100, resistance signals from 10 up to 5 , voltages and currents in range: -11 V...+11 V and 22 mA...+ 22 mA - accuracy 0.025% - STEP and RAMP function, - led out 24 V terminals, - RS 232C interface, - available in the option for pressure calibration. The INMEL 60 calibrator is destined to check and control systems, industrial automatic control engineering devices such controllers, recorders, meters, etc. This instrument has the possibility to generate and measure signals from ten thermocouples, five thermometer resistances, four voltage ranges, two current ranges, two resistance ranges. Thermoelectric terminals have an internal temperature measurement and for this reason make possible the generation or measurement of thermoelectric signals with the compensation for the given thermocouple. In this working mode, a real thermocouple is added to thermoelectric measuring terminals, and compensation conductors to thermoelectric generating terminals. The calibrator ensures the simultaneous generation of the signal on output terminals and the measurement of the signal on measuring terminals, thanks to this feature the calibrator is suitable to check transducers. The INMEL 60 calibrator enables to check two-wire transducers. the used graphical display contains a lot of information on a screen with a good readability. The display ground-lighting, which can be switched off, is especially useful in conditions of an insufficient lighting. The internal supply from the battery enables the work not only in laboratory conditions but also on the object. The calibrator can also be used to the maintenance and servicing of industrial measuring instruments, systems and electronic equipment. Application: Checking and calibration: - measuring transducers controlled by a voltage or current signal, a thermoelement or resistance thermometer, - two-wire transducers, - temperature meters, - pressure transducers, - manometers, - measuring and control lines.
Technical parameters: - Voltage ranges from 200 V up to 1000 V, - Current ranges from 200 A up to 20 A, - Frequency ranges from 20 Hz up to 100 kHz, - Resistance from 1 up to 19 M, - Voltage accuracy from 35 ppm, - Current accuracy from 150 ppm, - Ample software, - High output load, - RS 232C , IEEE488 interfaces. The INMEL 7000 calibrator is device with very high precision and simultaneously high load, thanks that it pulls ones weight very well with checking modern type as well older types of meters. It is characterized elastic and open systemic structure. We offer varius version of this calibrator from very simple e.g the DC voltage calibrator up to full configuration : DCV, DCI,ACV,ACI and R. Thanks to ergonomic desc and rich internal software the INMEL 7000 calibrator is very handly. In calibrator INMEL 7000 used modern construction solution, in which used new generation of electronics elements of renowned worldwide companies. Thanks that ones received very good metrological parameters, reduced quantity of compnents, and in this way augment the reliability of this calibrator. Application: Checking and calibration: - AC and DC voltmeters, - AC and DC ammeters, - frequency meters, - measuring transducers, - ohmmeters.
Technical parameters: - Voltage ranges 0.2 do 1000 V, - Current ranges od 20 mA do 20 A, - Frequency ranges od 40 Hz do 5000 Hz, - Voltage and current accuracy DC 0.02%, - Voltage and current accuracy AC 0.05%, - Load carrying capacity 40 VA, - Serial interface RS232, USB, Ethernet. The INMEL 1000 calibrator was made on base of modern componenets of microprocessor technologies. Applicated technologies are comparable with technologies used by leading global companies.The INMEL 1000 calibrator characterize oneself the innovative structure of operation in range of output signals and operation of measuring and regulatory loop.For AC course possible is the synchronous operation with the main. This possibility influence on output parameters, reliability, comfort of work, the communication way with user and external devices. The calibrator INMEL 1000 fulfils directives of the European Union within the range safeties and the electromagnetic compatibility:The production of the INMEL 1000 calibrator does not create threats for environment. Application: Checking ang calibration: - AC and DC voltmeters, - AC and DC ammeters, - frequency meters, - measuring transducers.
Parameters: - voltage measure: 0 100mV, 0 10V, - current measure: 0-24 mA, - voltage generation: 0 100 mV, 0 10V, - current generation: 0 24 mA, - voltage accuracy: 0.02% + 2 digits, - current accuracy: 0.015% + 2 digits, - loop power output: 24V Calibrator INMEL 50 integrate generation and measurement function of electric signals, used in automatic industry. The main features of this devices is high accuracy and resolution of generating or measuring signals, friendly operation and large display. Application: Checking and calibration: - measuring transducers, - measuring and control lines, - current loop.
* HV power filter (also Capacitive Voltage Divider) * Exciter transformer * Voltage regulator * Control and Measuring System (manual operation or computer-aided automatic systems)
Parameters WEW-100 Accuracy 1% of indicated value Measuring range of force(kN) 2-100kN Subsection of force 1,2,5,10 Accuracy of deformation measurement 0.5%F.S Clamping diameter for round specimen(mm) ;6-22 Clamping width of flat specimen(mm) 40 Clamping thickness of flat specimen(mm) 0-15 Testing space Tension 550 Compression 500 Platen size 100 Distance of bending by pass roll(mm) 30-400 Piston stroke(mm) 250 Power supply : 50Hz Working environment Room temperature : relative humidity Overall dimension(mm) Frame machine730x500x2000 Control System 1070x810x1730 Weight(Kg) 1370
Digital control hydraulic compression testing machine 1. Maximum Testing Load: 600kN 2. Measuring Range of Load: (24-600) kN 3. Accuracy of Testing Load: 1% 7. Distance between Upper and Lower Platen: 225mm (Adjustable) 8. Size of Upper Compression Platen: 180mm 9. Size of Lower Compression Platen: 250mm 10. Piston Ram Stroke: 150mm 11. Power Supply: three phase, 380/220V;50/60Hz 12. Working Environment: 80% Overall dimension: Frame: 1120, 1650(MM) Weight: Frame:950kg
1. Maximum Testing Load: 2000kN 2. Measuring Range of Load: (80-2000) kN 3. Accuracy of Testing Load: 1% 4. Rate of Loading Speed: 0.5N/s~10kN/s 5. Accuracy of Rate of Loading Speed: 5% 6. Accuracy of constant testing Loading: 1% 7. Distance between Upper and Lower Platen: 500mm (Adjustable) 8. Size of Upper Compression Platen: 230;280mm 9. Size of Lower Compression Platen: 230;280mm 10. Piston Ram Stroke: 200mm 11. Power Supply: three phase, 380/220V;50/60Hz 12.Working Environment: 80% Overall dimension: Frame: 1115 Control System : 187; Weight: Frame:4850kg, 200kg
his series testing machine is suitable for tensile, compression, bending, shearing, peeling and tearing test of metal and nonmetal materials, such as rubber, plastic, electrical wire and cable, composite, profiled bar, bar metal, board, spring, components and so on. It confirms to ISO 75001ú¼ASTM A370, ASTM E4 ASTM E8 and JIS, DIN, BSEN testing standards. AD800 in this machine is whole digit multi center closed loop measuring and control system. It adequately absorbs advanced functional characteristics and integrates the latest international professionally developed measuring and control system. Control software can automatically finger out routine data, such as tensile strength, yield strength, modulus of elasticity, extend rate after rupture, non-proportional extend strength RP0.2, etc. It can adopt many kinds of controlling modes, such as constant force, constant displacement, constant deformation, and real time display many testing curves of force-displacement, force-time, stress-strain. These curves automatically switch. Testing process control and data processing conform to the requirements of International standards. This machine is beautiful, multifunctional, safe and easy. Parameters: WDW-1 WDW-2 WDW-5 Maximum force: 1KN 2KN 5KN Accuracy: í_í+1% (0.5% as special order) Measuring range of force (KN): 0.2%--100%FS Resolution of force: 1/200000 of maximum force and no subsection of all scale Accuracy of displacement measuring: í+0.5% Resolution of displacement: 0.03ª¦m Speed adjusting range of displacement: 0.001-500mm/min Accuracy of deformation measuring: í+0.5% Range of deformation measuring: 2%í½100%FS Speed adjusting range of force; 0.005-5%F.S / S Speed controlling accuracy of force: ¿Qí+2.0% of the set value (speedú+0.05%FS/S) ¿Qí+0.5%/í+1.0% of the set value ( speed¿R0.05%FS/S) Speed adjusting range of deformation: 0.005-5%FS/S Speed controlling accuracy of deformation:¿Qí+2.0% of the set value (speedú+0.05%FS/S) ¿Q í+0.5% of the set value ( speed¿R0.05%FS/S) Valid tension testing space: 800 Compression testing space: 700 Clamping sample: Flat and round sample Power supply: 380V/220ú¼50/60Hz Working environment: Room temperature 10íµí½30íµ, relative humidityí_80% Base configuration : Panasonic servo motor, precision photoelectric encoder Weight(Kg): 300