Application Used as internal wiring of appliances and electronic equipment, instruments, meters. Also used for wiring and cable assemblies in data and electronic equipment. Specification Inner conductor: Solid or stranded Copper conductor Insulation: PVC Reference standard: UL758 UL items: UL1015, UL1007, UL1028, UL1080, UL1430, UL1761, UL1800,UL1331, UL1332, UL1333, UL1569, UL1617, UL1672, UL1673 CONSTRUCTION ITEMGAUGEConductorInsulation mm UL100726AWG7/0.161.33 UL100726AWG1/0.4041.3 UL100724AWG11/0.161.47 UL100724AWG1/0.5111.42 UL100722AWG17/0.161.65 UL100722AWG1/0.6431.6 UL100720AWG26/0.161.82 UL100720AWG1/0.8131.76 UL101524AWG11/0.162.23 UL101524AWG1/0.5112.16 UL101522AWG17/0.162.4 UL101522AWG1/0.6432.33 UL101520AWG26/0.162.6 UL101520AWG1/0.8132.55
We are manufacturer of UL style wires and cables. Customized according to standards
Decorative Christmas wire / UL Wire Application: The lighting soft wire is used in outdoor for decorative , as well as can be used in household. Working conditions: Rated voltage:300V Rated temperature: 105°C Conductor can be single wire, standard wires or thinner soft copper wire Insulation material complies with the requirements of ROHS Wire has the flame test of ULVW-1 and CSA FT2
UL2464 Wire and Cable Applications: As measuring, monitoring and control cable, it is suitable for the places of machine tool manufacturing, complete equipment installation engineering, power station, refrigeratory equipment, OA equipment, data processing system and heating and air-condition system. Properties: Heat resistance, good insulation property, excellent chemical performance, extruding sheath Standards: UL 758 Structure: Conductor: fine strands of tinned copper wire, exellent corrosion resistance. Insulation: special PVC Colour: acc. to UL 758 Sheath: 80 heat-resistant flame-resistant PVC, pass VW-1 flame testing Colour: black (RAL9005) green (RAL6018) Orange(RAL2003) purple(RAL4001) Or refer to customers requirement. Technical data: Rated voltage: 300V Test voltage: 2000V Temperature range: Fixed installation: -40--+80 Flexing installation: -10--+80 The minimum bending radius: Fixed installation: 4×external diameter Flexing installation: 15×external diameter.
Rated temperature:105 deg c Rated voltage:600v Reference standard:ul 758, ul 1581, csa c22.2no.210.2 Flame test:ul vw-1, csa ft1 Pvc insulation , rohs compliant 305m/coil or 610m/coil
UL 1592 AWG 14 Teflon Insulated Tinned Copper Stranded Wire TECHNICAL DATA Nominal Voltage:300V Temperature Range:-100C~+200C/150C Conductor:Tinned Copper, silver-plated Copper or Nickel-plated Copper Insulator:FEP TEFLON O.D.Tolerance:±0.03mm Testing Volta:2000V Colour: white, blue, red, black, brown, orange, purple, gray, yellow, green, transparent, yellow-green, etc CHARACTERISTIC High temperature resistance, low temperature resistance, anti-acid, anti-oil, antisepsis and moistureproof, UL 758, RoHs compliance. APPLICATION Apply to household appliance, illumination & lighting & headlamp, electric machines, temperature sensor, military series, metallurgy chemical series, motor cars & ships electrical installation.
UL 1015 Approved PVC Insulated Tinned Copper Conduct Electric Electrical Wire TECHNICAL DATA Rated voltage: 600V Rated temperature:-40�ºC~+105�ºC Conductor: Tinned or bare copper Insulator: PVC OD Tolerance: �±0.10mm Colour: white, blue, red, black, brown, orange, purple, gray, yellow, green, transparent, yellow-green, etc CHARACTERISTIC Flexible, easy assemble, cold resistance, stable performance, UL 758, RoHs compliance. APPLICATION Apply to household appliance, illumination & lighting & headlamp, electric machines, temperature sensor,metallurgy chemical series, motor cars & ships, electrical installation.
Product features: Rated voltage:600v Rated temperature:-60+200 Conductor: nickel-coated, tin-coated and silver-coated copper wire Insulator: silicone rubber Applicable for electron, electrical household appliance, lamps and lanterns, And the internal high temperature environment of combustion equipment Wire lettering: ul awm3135 Items Technical datas Applied standard Outer appearance Smooth, even, without loose Ul 758 Ul 62 Ul 1581 Spark test Ac6kv/ 0.15 s Vol. Test 2 kv/1 min Insulation resistance 30.5m¦¸.Km Mechanical properties of insulation material Before aging Tensile strength 3.45n/mm² Elongation at break 100% After aging Tensile strength 60% of the tensile strength before aging (2101¡á1440h) Elongation at break 25% of the elongation before aging Poisonous substance control Comply with rohs rule Eu2002/95/ec Packed in roll or on woooden reel, then packed in carton, 500-1000cartons/20'fcl
UL 1332 Power Cable Fiber Optic Teflon Insulated Electronics Electric Wire TECHNICAL DATE Nominal Voltage:300V Temperature Range:-100�ºC~+200�ºC Conductor:Tinned Copper Insulator:FEP TEFLON O.D.Tolerance:�±0.10mm Testing Volta:2500V Colour: white, blue, red, black, brown, orange, purple, gray, yellow, green, transparent, yellow-green, etc CHARACTERISTIC High temperature resistance, low temperature resistance, anti-acid, anti-oil, antisepsis and moistureproof, UL 758, RoHs compliance. APPLICATION Apply to household appliance, illumination & lighting & headlamp, electric machines, temperature sensor, military series, metallurgy chemical series, motor cars & ships electrical installation.
¡¾application¡¿£º Adapt to pvc, pp, pe plastic high-speed extrusion, mainly used in the production line of ul electronics, computer wire core cable, power cable core wire, automotive wire, bv, bvv building wire, power cable, computer cable, insulated wire outside the sheath extrusion, power cable, power cable extrusion production.
Sna-360 analogue addressable photoelectric smoke detectors are microprocessor controlled state-of-the-art detectors Compatible with popular control and indicating equipment loop protocols. Advanced electronics in conjunction with a photoelectric smoke sensing chamber provides early detection of fire and High immunity against unwanted alarms. Photoelectric smoke sensor Analogue detection discrimination Dual leds for 360° visibility Dc 24 v operation 2-wire connection to many popular loop protocols Dip switch address setting 125 usable detector address settings per loop Optional remote led output
HNC-310 non-addressable heat detectors are suitable for connection to 2-wire non-addressable fire detection control and indicating equipment, or to addressable fire detection control and indicating equipment that can accept non-addressable type detectors. An electronic thermistor provides sensitive rate-of-rise operation or fixed-temperature operation when the response threshold value is exceeded. Durable heat sensor Analogue detection discrimination Dual LEDs for 360° visibility 2-wire and 4-wire models for DC 12 V and DC 24 V operation Dual LEDs for 360° visibility 4-wire models available with a N/O alarm relay output 4-wire models available with auto-reset 2-wire models available with remote LED output Connects to zone monitor for use with addressable control and indicating equipment
Application Use for control and connecting cable on data transmission within building management system, speaker audio system and control measurement. Suitable for use in dry and damp environment. Cable Structure & Features Conductor Material : Tinned copper stranded Insulation : Semi-Rigid PVC Drain Wire : Tinned copper stranded Shielding : Aluminium foil laminated screen Outer Sheath ; PVC Sheath Colour : black or gray Technical Data Standard : UL Style 2464 Approvals : UL apporoved Rated Voltage : 300V Testing Voltage : 1500V Flame Retardant : VW-1 Insulation Resistance : Min 20Mx km Min. Bending Radius : 10 x cable diameter Operating Temp. : -30C / +80C
Features of insulated pvc wiring ducts: Material: hard pvc Temperature range: -40 degree~70 degree Fire rating: UL94V-0 Certificate: UL, CE Designs: slotted, solid Color: grey, white, blue, black We are insulated pvc wiring ducts, slotted wiring ducts, solid wiring ducts, slotted cable ducts, solid cable ducts, pvc wiring trunking, pvc cable trunking manufacturer in china. 50m in a carton
We deals in the following products of India, China, Taiwan and Korea Origin:- 1) Hot Rolled Steel (Hot Rolled Sheets, Hot Rolled Coils, Hot Rolled Plates, Hot Rolled Bars etc.) 2) Galvanized Steel (Galvanized Steel Tapes, Galvanized Steel Wires, Galvanized Steel Strips, Galvanized Steel Coils, Galvanized tubes etc.) 3) Cold Rolled Steel (Cold Rolled Steel Strips, Cold Rolled Steel Coils, Cold Rolled Sheets etc.) 4) Stainless Steel (Stainless Steel Strips, Stainless Steel Coils, Stainless Steel Wire, Hardened and Tempered Spring Steel, Stainless Spring Steel, Spring Steel Wires etc.) 5) Steel Tube and Pipes (ERW, CRW, CRS, Black, Galvanized, Stainless) 6) Forged Column Clamps, Girder Clamps, Pressed Clamps, Rapid Clamps, Support Clamps & Wedge Clamps. 7) Heavy Duty Props & Light Duty Props. 8) Nuts, Bolts, Nails & Fasteners 9) System Scaffolding, Base Plate & Adjustable Base. 10) Steel Tie Rod, Waller Plates and Wing Nuts. 11) Drop Forged and Pressed Sheet Metal Couplers of all types. 12) Steel Billets, Steel Angle & Steel Channels. Price: After receiving complete details
The Tire derived Steel or Tire Wire Scrap is a light melting scrap obtained during the shredding and granulation process of used tires. Generally 10% - 20% of the weight of an old passenger car tyre usually consists of steel. An average shredding plant produces about 100-200 MT of steel tyre wire and its quality can vary according to technology, storing and management systems adopted by the producing plants. We can provide tire wire scrap that still contains up to 20% rubber/fiber. This percentage is detected by manual separation test. The material can be loaded loose in 40 HC container. For further details, please feel free to contact us.