HNC-310 non-addressable heat detectors are suitable for connection to 2-wire non-addressable fire detection
control and indicating equipment, or to addressable fire detection control and indicating equipment that can accept
non-addressable type detectors.
An electronic thermistor provides sensitive rate-of-rise operation or fixed-temperature operation when the response
threshold value is exceeded.
Durable heat sensor
Analogue detection discrimination
Dual LEDs for 360° visibility
2-wire and 4-wire models for DC 12 V and DC 24 V operation
Dual LEDs for 360° visibility
4-wire models available with a N/O alarm relay output
4-wire models available with auto-reset
2-wire models available with remote LED output
Connects to zone monitor for use with addressable control and indicating equipment
The FK-5-1-12 Clean Agents, also known as NOVEC1230 Fire Suppression Agents, is a highly efficient and reliable hydro-fluorocarbon fire extinguishing solution. This product is designed to quickly and effectively suppress fires in various settings while being non-toxic, environmentally friendly, and safe to use. Model Number: FK-5-1-12 clean agents Product Name: NOVEC1230 Fire Suppression Agents Reliability: High Model NO.: FK-5-1-12 clean agents Application The FK-5-1-12 Clean Agents is suitable for use in various applications, including but not limited to: Commercial buildings Industrial facilities Data centers Telecommunication rooms Museums and art galleries Power generation plants Server rooms Control rooms Storage facilities
Product categories of Sensor Type of Fire Alarm, we are specialized manufacturers Sensor Type Of Fire Alarm, Sensor Type Fire Alarm suppliers/factory, wholesale high-quality products of Fire Alarm Sensor Type R & D and manufacturing, we have the perfect after-sales service and technical support. Look forward to your cooperation Here you can find the related products in Sensor Type of Fire Alarm, we are professional manufacturer of Sensor Type Of Fire Alarm,Sensor Type Fire Alarm,Fire Alarm Sensor Type,Fire Alarm. We focused on international export product development, production and sales. We have improved quality control processes of Sensor Type of Fire Alarm to ensure each export qualified product. If you want to know more about the products in Sensor Type of Fire Alarm, please click the product details to view parameters, models, pictures, prices and other information about Sensor Type Of Fire Alarm,Sensor Type Fire Alarm,Fire Alarm Sensor Type,Fire Alarm. Whatever you are a group or individual, we will do our best to provide you with accurate and comprehensive message about Sensor Type of Fire Alarm
Sna-360 analogue addressable photoelectric smoke detectors are microprocessor controlled state-of-the-art detectors Compatible with popular control and indicating equipment loop protocols. Advanced electronics in conjunction with a photoelectric smoke sensing chamber provides early detection of fire and High immunity against unwanted alarms. Photoelectric smoke sensor Analogue detection discrimination Dual leds for 360° visibility Dc 24 v operation 2-wire connection to many popular loop protocols Dip switch address setting 125 usable detector address settings per loop Optional remote led output
Specifications:- * Control key switch * Mains healthy indicator * Continuous alarm signal * Built-in battery * Polarity protection for battery * Push buttons for Evacuate, Reset and Alarm silence * Monitored alarm circuits for both open and short circuit * Individual sounder circuits for zones (optional) * Indicators for charger fault and battery fault * All controls are on front fascia * Knockouts on top and bottom sides for easy installation * Main supply - 240 V AC +/- 10%, 50/60 Hz * Battery supply - 24 V DC (Sealed Lead Acid) * Glass fuse protection - Main supply, Charging voltage, Sounder circuit, Reserve battery connection * Auxiliary relay contacts -30 V DC, 1 A, NO/NC
Horizontal split case fire pump system. Diesel engine driven. Pump: horizontal split case from 250 gpm to 2500 gpm. Standard packing.
EN 45545-2 New Fire test to railway vehicles EN 45545-2 New Fire test to railway vehicles -Standard Brief EN45545 This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by September 2013, and conflicting national standards shall be withdrawn at the latest by March 2016. EN 45545 supersedes BS 6853, DIN5510-2,NFF16-101 national standards. This European Standard exists in three official versions (English, French, German). EN 45545-2 New Fire test to railway vehicles - European Standard EN 45545-2:2013+A1:2015: Fire protection of railway vehicles - Part 2: Requirement for fire behaviors of materials and components EN 45545-2 New Fire test to railway vehicles-Scope This part of EN 45545 specifies the reaction to fire performance requirements for materials and products used on railway vehicles as defined in EN 45545-1. For each hazard level, this part specifies the test methods, test conditions and reaction to fire performance requirements.It is not within the scope of this European Standard to describe measures that ensure the preservation of the vehicles in the event of o fire. EN 45545-2:2013+A1:2015 Fire Test to railway components -Hazard levels HL1, HL2, HL3 EN 45545-2 New Fire test to railway vehicles -Test Method EN 45545-2 R1: Surface Products EN 45545-2 R10: Flooring Covering EN 45545-2 R15, R16: Wire & Cable EN 45545-2 R22/ R23: Interior seals, Electrical Equipment EN 45545-2 R24 : Electrotechnical products EN 45545-2 R24/R25 : PCB Printed circuit boards EN 45545-2 R26 : Small electrotechnical products EN 45545-2 New Fire test to railway vehicles -Reference Standard EN 45545-1: Fire Protection of railway Vehicles â?? Part 1: General EN 45545-2: Requirement for fire behaviour of materials and components EN 45545-3: Fire resistance requirements for fire barriers and partitions EN 45545-4: Fire safety requirements for railway rolling stock design EN 45545-5: Fire safety requirements for electrical equipment EN 45545-6: Fire control and management system EN 45545-7: Flammable liquid and flammable gas installations We also can provide the following service of fire test to Railway EN45545-2 Fire protection of railway vehicles: Requirement for fire behaviors of materials EN45545-3 Fire resistance requirements for fire barriers NFPA 130 Standard for fixed guideway transit and passenger rail systems DIN5510-2 Fire behaviour of materials and parts, classification, requirement BS6853 Code of practice for fire precautions in the design and construction NF F16-101 Railway Rolling Stock Fire Behavior Choice of Material CASfire Technical Co.,Ltd 8F Building 4, Chinese Academy of Science, No.255 South Duiying Road,Jimei, Xiamen 361021, China Tel: (+86) 0592-3500085 MP: (+86) 18906059211 Email: info@casfire.cn Website: http://www.casfire.cn
EN 45545-2:2013+A1:2015: Fire protection of railway vehicles - Part 2: Requirement for fire behaviors of materials and components Standard Brief EN45545 This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by September 2013, and conflicting national standards shall be withdrawn at the latest by March 2016. EN 45545 supersedes BS 6853, DIN5510-2,NFF16-101 national standards. This European Standard exists in three official versions (English, French, German). Scope This part of EN 45545 specifies the reaction to fire performance requirements for materials and products used on railway vehicles as defined in EN 45545-1. For each hazard level, this part specifies the test methods, test conditions and reaction to fire performance requirements.It is not within the scope of this European Standard to describe measures that ensure the preservation of the vehicles in the event of o fire. Hazard levels HL1, HL2, HL3 Test Method EN 45545-2 R1: Surface Products EN 45545-2 R10: Flooring Covering EN 45545-2 R15, R16: Wire & Cable EN 45545-2 R22/ R23: Interior seals, Electrical Equipment EN 45545-2 R24 : Electrotechnical products EN 45545-2 R24/R25 : PCB Printed circuit boards EN 45545-2 R26 : Small electrotechnical products Reference Standard EN 45545-1: Fire Protection of railway Vehicles â?? Part 1: General EN 45545-2: Requirement for fire behaviour of materials and components EN 45545-3: Fire resistance requirements for fire barriers and partitions EN 45545-4: Fire safety requirements for railway rolling stock design EN 45545-5: Fire safety requirements for electrical equipment EN 45545-6: Fire control and management system EN 45545-7: Flammable liquid and flammable gas installations We also can provide the following service of fire test to Railway EN45545-2 Fire protection of railway vehicles: Requirement for fire behaviors of materials EN45545-3 Fire resistance requirements for fire barriers NFPA 130 Standard for fixed guideway transit and passenger rail systems DIN5510-2 Fire behaviour of materials and parts, classification, requirement BS6853 Code of practice for fire precautions in the design and construction NF F16-101 Railway Rolling Stock Fire Behavior Choice of Material
Standard Brief EN45545 This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by September 2013, and conflicting national standards shall be withdrawn at the latest by March 2016. EN 45545 supersedes BS 6853, DIN5510-2,NFF16-101 national standards. This European Standard exists in three official versions (English, French, German) Scope This part of EN 45545 specifies the reaction to fire performance requirements for materials and products used on railway vehicles as defined in EN 45545-1. For each hazard level, this part specifies the test methods, test conditions and reaction to fire performance requirements.It is not within the scope of this European Standard to describe measures that ensure the preservation of the vehicles in the event of o fire. Hazard levels HL1, HL2, HL3 Test Method EN 45545-2 R1: Surface Products EN 45545-2 R10: Flooring Covering EN 45545-2 R15, R16: Wire & Cable EN 45545-2 R22/ R23: Interior seals, Electrical Equipment EN 45545-2 R24 : Electrotechnical products EN 45545-2 R24/R25 : PCB Printed circuit boards EN 45545-2 R26 : Small electrotechnical products Reference Standard EN 45545-1: Fire Protection of railway Vehicles â?? Part 1: General EN 45545-2: Requirement for fire behaviour of materials and components EN 45545-3: Fire resistance requirements for fire barriers and partitions EN 45545-4: Fire safety requirements for railway rolling stock design EN 45545-5: Fire safety requirements for electrical equipment EN 45545-6: Fire control and management system EN 45545-7: Flammable liquid and flammable gas installations We also can provide the following service of fire test to Railway EN45545-2 Fire protection of railway vehicles: Requirement for fire behaviors of materials EN45545-3 Fire resistance requirements for fire barriers NFPA 130 Standard for fixed guideway transit and passenger rail systems DIN5510-2 Fire behaviour of materials and parts, classification, requirement BS6853 Code of practice for fire precautions in the design and construction NF F16-101 Railway Rolling Stock Fire Behavior Choice of Material