Ultrasonic beauty High frequency ultrasound transmits into the skin surface to clean the facial dirt, remove the freckles and wrinkles Frequency:3MHz Mode: Pulsed Wave Treatment area: 3.8cm Switch: ON/OFF Timer setting: 10 minutes Auto off Dimensions: 50 x 45 x 190mm Weight: 200 g
RBEF Tri-clamp Sanitary type electromagnetic flowmeter especially designed for the food & beverage and pharmaceutical industries and is available with hygienic and flexible process connections. It ideals for conductive liquids. It comes in sizes from 15mm to 200 mm. The RBEF Sanitary type electromagnetic flowmeter (EMF) is widely used for is ideal for the food and beverage industries, such as drink water, milk, beer, food & beverage juice filling machine and many other industrial fluid. Itâ??s body and connections are polished 304SS.
SUS304 stainless steel Electromagnetic Flowmeter measurement, high precision, flow range reach to 1500: 1; 4. Converter adopts to 16-bit embedded microprocessor and surface mounting technology, convenient preferences, totally Chinese menu operation, easily use, with self-check and diagnosis functions; 5. With the function of measuring two way flow, can show the positive and reverse flow, also have two way current and rate output, which is convenient for the record and store different flow signal; 6. Inside have three counters, which can separately show positive cumulation, reverse cumulation and D-value calculation; 7. With RS485 or RS232 digital communication signal output; 8. With self-check and diagnosis functions. QTYB G Standard Type R Remote type S Sanitary Type I Insertion Type Medium Conductivity Fluids Accuracy ± 0.5% ± 0.5% ± 0.5% ± 1.5% Repeatability ± 0.25% ± 0.25% ± 0.25% ± 0.75% Fluid Temperature -25° C ~ 130 ° C -25° C ~ 130 ° C -25° C ~ 130 ° C -25° C ~ 130 ° C Conductivity ≥ 5¦Ìs/cm ( soft water should be ≥ 20 ¦Ìs/cm) Size 10mm ~2200 mm 10mm ~2200 mm 10mm ~125 mm 200mm ~3000 mm Operation Pressure 0.6Mpa/1.0Mpa/1.6Mpa/2.5Mpa/4.0Mpa/Others Velocity 0.5 m/s ~ 10 m/s Flow Direction Forward / Reversed Electrodes Material 316L / Hastelloy C2, B4/Tantalum/Titanium/Platinoiridita/others Liner Material Rubber /PTFE/PFA PFA PTFE Electrodes Type Standard Qty of Electrodes 2 pairs ( one pair for measuring, one pair for grounding) 1 pair( for measuring) Measuring tube Material 304 Stainless Steel Flange Material Carbon steel/304 Stainless steel 304 Stainless steel 304 Stainless steel Installation Type Wafer/flange Tri-clamp/screw Flange/plug-in Protection level IP65/P68 ( Remote Version) Power 220VAC ± 20% 60HZ / 24 VDC Signal Output 4~20mA Communication Hart / Modbus/ Profibus Electrical connection 2* M20 * 1.5 Explosive-Proof Exdemib II BT3~T6 Construction Type Compact / Remote Operation Environment Environment temperature: -25 ° C~ + 60 ° C; Relative Humility: 5% ~90% wooden/paper box
Description - It Use A Magnetic Field Applied To The Metering Tube, Which Results In A Potential Difference Proportional To The Flow Velocity Perpendicular To The Flux Lines. Origin - Korea Size - 10a ~ 900a "packaging Details (w*d*h)/mm" - 600*500*500 Weight(kg) - 6 ~ 31 FOB ($) - " Retail Price + (shipping Cost) " MOQ - 1 Set Note - All The Product Information May Be Changed Depending On The Specification.
Description - "it Is A Flowmeter For Measuring Fluid Flow Rates In An Enclosed Conduit. It Has The Karman's Vortex That Is Proportioned To The Velocity Of Fluid In The Down Stream Of Trigonal Prism (delta Body). " Origin - Korea Size - 15a ~ 300a "packaging Details (w*d*h)/mm" - 500*300*200 Weight(kg) - 3 ~ 20 FOB ($) - " Retail Price + (Shipping Cost) " MOQ - 1set NOTE - All the product information may be changed depending on the specification.
Electromagnetic Flowmeter model No FMF 2500 Manufacturing Unit in Coimbatore
Nozzle flowmeter Product name:, nozzle flowmeter Product code:, 152659-821 Processing custom origin:, in kaifeng Type:, type sklgb series Type:, nozzle throttling device Measuring range:, 1932 nozzle: 50 - 500; the length to diameter nozzle: 50-630 Nominal size:, dn50-dn1000 The accuracy of measurement:, 1-2.5 Nominal pressure:, 10 or less (mpa) Scope of application:, gas and liquid.
Operation interface: mobile APP (Android, iOS) Smart Intelligent LCD display function Display Interface: English or Chinese Easy to Setup and install/Variety of sizes range. High Accuracy:±0.5% of reading(RD) Flow direction function: Plus or Reverse Alarm Function: Excitation and No fluid tubes Alarm. Install Way: Adjustable and Flange type. https://www.fgttw.com/en/products/flow-meter-oem-odm-solution/water-flow-meter/fmg-w-wireless-type-electromagnetic-flow-meter
Turbine flowmeter can be divided according to function name gas flow meter,flue gas meter,steam flow meter,gas flow meter,compressed air flow meter,liquid flow meter. LWG type turbine flow sensor and receiving electrical signals of the display instrument of turbine flowmeter, which is used to measure low and medium viscosity closed pipes Degree of fluid (liquid or gas), the total volume flow and in petroleum, chemical industry, metallurgy, aviation and scientific research departments for a wide range of applications. Sensor is composed of turbine sensor components and amplifier, the structure of the two together for one-piece: to measure the structure of the positive and negative flow For two-way type; With inserted rod can be installed in the large diameter pipe flow body flow structure for a plug-in. Based on the principle of moment balance sensor work. When the fluid flows through the sensor, promote the impeller rotation, when the flow rate must be dynamic torque Maintain and drag torque balance, the impeller speed. Evenly distributed on the permeability of the impeller blade with the impeller rotation, to periodically change detection The reluctance of the magnetic field sensor (coil), electrical pulse signal detector, after the amplifier amplification output. The output electric pulse frequency and impeller speed Is proportional to the impeller speed is proportional to the flow in, so the output electric pulse frequency is proportional to the flow sensor flow, 4-20 ma signal is converted is proportional to the flow.
LUGB type vortex flowmeter is according to the principle of Carmen (Karman vortex street measuring gas, steam or the volume of liquid flow, the volume of the standard condition or volume flow to mass flow meter. And can be used as flow transducer is applied to automatic control system.Vortex flowmeter can be divided according to function name gas flow meter,flue gas meter,steam flow meter,gas flow meter,compressed air flow meter,liquid flow meter. The instrument adopts the advanced differential technology, cooperate the measures such as isolation, shielding, filtering, overcome the similar products such problems as poor vibration resistance, small signal data disorders, using a unique sensor encapsulation technology and protective measures, to ensure the reliability of the product. Products are both basic and compound type, basic measuring single traffic signal; Compound can be realized at the same time temperature, pressure, flow rate measurement. Each type has overall, fission structure, in order to adapt to different installation environment. Vortex flowmeter classification: LUCB series plug-in vortex flowmeter, LUCB series of vortex flowmeter is mainly used for industrial piping medium fluid flow measurement, such as gas, liquid and vapor, and other media. Is characterized by small pressure loss, wide range, high precision, working condition of the measurement volume flow is almost not affected by the fluid density, the influence of the parameters such as pressure, temperature, viscosity. No moving mechanical parts, so high reliability, small amount of maintenance. Instrument parameters can be long-term stability. Vortex street flowmeter using piezoelectric stress sensor, high reliability, can be in - 20 ~ + 250 temperature range. There are standard signal simulation and digital pulse signal output, easy with the computer and digital systems, is a more advanced, the ideal flow meter.
SKLD type electromagnetic flowmeter is the intelligent electromagnetic with research and development, which adopts domestic and foreign advanced technology. Electromagnetic transducer with high-speed central processing unit (CPU) and the features of rapid computing speed and high precision, reliable performance measurement are in both Chinese and English menu.Electromagnetic flowmeter is divided into one type of electromagnetic flowmeter and split electromagnetic flowmeter,Insert electromagneticflowmeter. Electromagnetic flowmeter can be divided according to the use of function:liquid flow meter,water flow meter,sewage flow meter,Intelligent electromagnetic flowmeter,explosion-proof flow meter,irrigation flow meter,mud flow meter Sensor uses non-uniform magnetic field technology and special magnetic circuit structure. Magnetic field is stable and reliable, and the circuit structure reduces the volume, The sensor can reflect the traffic change timely and effectively, and have a stable value of measuring water, sewage, slurry, pulp, acid, alkali, salt slurry liquid and food, etc. There are lots of wide applications in the petroleum chemical industry, metallurgy, coal, water conservancy project of water supply and drainage, sewage treatment etc. The electromagnetic flowmeter has two types: the compact and the sensor for remote transmitter.
Nozzle flowmeter nozzle flowmeter manufacturer Product name: nozzle flowmeter Product code: 152659-821 Update time: 2015.08.25 Views: 1277 Processing custom origin: in kaifeng Type: type SKLGB series Type: nozzle throttling device Measuring range: 1932 nozzle: 50 ~ 500; The length to diameter nozzle: 50-630 Nominal size: DN50-DN1000 The accuracy of measurement: 1-2.5 Nominal pressure: 10 or less (Mpa) Scope of application: gas and liquid throttling device, also kn own as differential pressure flowmeter, Orifice flowmeter contains (integrated orifice flow meter, standard orifice, annular orifice flow meter, integrated annular orifice flow meter) Nozzle flow meter (integrated no zzle flow meter)can be divided according to function name gas flow meter, flue gas meter, steam flow meter, gas flow meter, compressed air flow meter, liquid flow meter. Throttling coffret - nozzle flowmeter has many advantages, but generally feel pressure pipeline installation on site work is large, also easy to leak, congestion and other issues. Differential pressure transducer made by leaps and bounds in recent years of development, not only the small size, and stable performance, easy to adjust, in use process basically don't need to adjust the zero point. These advantages contribute to a body orifice flowmeter (including orifice plate, the annular orifice, nozzle, etc.) in the development and application. Nozzle flow meter is to measure flow differential pressure generator, cooperate with all sorts of differential pressure gauge or differential pressure transmitter to measure all kinds of fluid flow in pipes. Standard nozzle throttling device with differential pressure transmitter, can measure the rate of flow of liquid, steam, gas, nozzle flowmeter has a long history background, all kinds of test data is complete. Simple structure, no moving parts, stable and reliable long-term use, rich experience in design and manufacture and application. Doesn't need a high degree of standardization, solid flow calibration. Standard orifice has reliable experimental data and improve the international and national standards. In foreign countries and has its inherent in the huge domestic market, users are familiar with, data; Follow the international standard calculation and processing, use agile and convenient; According to relevant data of estimate of flow meter between 60% and 70% of the total consumption. It is widely used in petroleum, chemical, metallurgical, power, light industry and other departments.
Turbine flowmeter Product name:turbine flowmeter Product code:164912-752 Update time:2015.08.25 Views:346 Processing custom origin:in kaifeng Type:type flow meter lwg series Type:impeller type flowmeter Measuring range:0.4-20000 (m3 / h) Summary: Turbine flowmeter can be divided according to function name gas flow meter, flue gas meter, steam flow meter, gas flow meter, compressed air flow meter, liquid flow meter.
Electromagnetic flowmeter Electromagnetic flowmeter Product code:145538-152 Processing custom origin:in kaifeng Type:type flow meter skld series Measuring range:2000 (m3 / h) Level of accuracy:0.5 Nominal diameter:dn3-3000 (mm) Working pressure:0.6 ~ 4 (mpa) Working temperature:- 10 - 150 Product overview Skld type electromagnetic flowm eter is the intelligent electromagnetic with research and development, which adopts domestic and foreign advanced technology. Electromagnetic transducer with high-speed central processing unit (cpu) and the features of rapid computing speed and high precision, reliable performance measurement are in both chinese and english menu.Electromag netic flowmeter is divided into one type of electromagnetic flowmeter and split electromagnetic flowmeter, insert electromagnetic flowmeter. Electromagnetic flowmeter can be divided according to the use of function:liquid flow meter, water flow meter, sewage flow meter, intelligent electromagnetic flowmeter, explosion-proof flow meter, irrigation flow meter, mud flow meter Sensor uses non-uniform magnetic field technology and special magnetic circuit structure. Magnetic field is stable and reliable, and the circuit structure reduces the volume, the sensor can reflect the traffic change timely and effectively, and have a stable value of measuring water, sewage, slurry, pulp, acid, alkali, salt slurry liquid and food, etc. There are lots of wide applications in the petroleum chemical industry, metallurgy, coal, water conservancy project of water supply and drainage, sewage treatment etc. The electromagnetic flowmeter has two types: the compact and the sensor for remote transmitter.
mini flowmeter Porter:sales9@gnflowmeter.com Site:www.microflowmeter.com Skype:shcixi_ru mini flowmeter(mini oil water flow meter) principle is a liquid pushing one pair of oval gears; volume of each cavity is a fixed volume; gear speed leads, the sensor sends the sync pulse count, oval gear rotated by the magnetic seal coupling and reduction gear mechanism passed directly to the counter indicates the total flow through the meter. If the additional transmission means, the display together with electrical instrument can achieve remote only instantaneous flow or accumulated flow. The mini flowmeter with 0.2% accuracy and low flow range.the high temperature is 200C,the max pressure is 1000Bar.the output is pulse and material is stainless steel and aluminum. Model Flow range Connection CX-M2-SS/AL 0.5~150 ml/min G1/8 female thread CX-M3-SS/AL 1-300 ml/min G1/8 female thread CX-M5-SS/AL 5-1000 ml/min G1/8 female thread CX-M6-SS/AL 0.5-100 l/H G1/4 female thread CX-M9-SS/AL 5-550 l/H G1/4 female thread CX-M12-SS/AL 1~30 L/min G1/2 female thread CX-M25-SS/AL 5-110 l/min G1 female thread CX-M40-SS/AL 10-250L/min G1 1/2 female thread CX-M50-SS/AL 10-500L/min G2 female thread select the JSN and mini flowmeter we will provide the professional service for you.
Width: 1.2 m to 4.2 m Thickness: 35 micron to 500 micron Ultrasonic welding bottom: 0,8mm In addition, we also accept sample orders, according to the requirements of customers.
Disposable gloves, rapid test, protective masks, hand sanitizers, disinfectants, ppe, thermometers, ventilators, oxygen concentrators, oximeters, humidifiers, flowmeters, nebulizers, suction devices, oxygen cylinders, high pressure gases regulators, medical gases installation systems, medical air and vacuum plants, medical oxygen generators.
Alumina Oxide ceramic balls may be used at temperatures up to 3180 'F. Ceramic balls are extremely hard, resistant to abrasion, and immune to all furnace atmospheres. Applications, where alumina oxide balls are used, include chemical pumps, down-hole pumps, valves, bearings, gauges, flowmeters, etc.
Now, the market of Low Cost Electromagnetic Flowmeter,China supplier 4-20ma output digital Magnetic Water Flow Meter Priceis very hot. There exist about 80 factories located in the suburb of Dongtai city in Zhejiang province, the cluster of this industry. But the market there is also filled with chaos. Many companies live on purchasing components to reassemble; some company may think it too troublesome and the work as Briefcase Company to declare that they are manufactures of Diesel industry oil oval gear flow meter of high quality. This situation is worrying. The so-called manufactures do not have their own calibrator at all; leave alone the accuracy of Diesel industry oil oval gear flow meter of high quality. Facing this complicated situation, the chief engineer, Mr. Tu Jianwen, who worked as a senior engineer in Siemens in Germany, came to Shanghai from his hometown Cixi in 2008. He was determined to create the world-class Low Cost Electromagnetic Flowmeter,China supplier 4-20ma output digital Magnetic Water Flow Meter Priceand established Shanghai Cixi Instrument Co. Ltd by the name of his hometown. The Low Cost Electromagnetic Flowmeter,China supplier 4-20ma output digital Magnetic Water Flow Meter Pricewere produced and developed by the technology of Siemens numerical control system. Once upon a time, China, the worlds factory, is always the synonym with the low quality. Especially, the Low Cost Electromagnetic Flowmeter,China supplier 4-20ma output digital Magnetic Water Flow Meter Pricewhich are used to control in automatic process are produced cumbersome and noisy and can not measure the sticky medium. Thus, whether the quality is stable has become users greatest concern. So, sometimes buying Low Cost Electromagnetic Flowmeter,China supplier 4-20ma output digital Magnetic Water Flow Meter Priceis like buying a lottery ticket. Whats more, the quality is left to chance and cannot be guaranteed. That Shanghai Cixi Instrument Co. Ltd has introduced the technology from Siemens in Germany has greatly improved the quality of Low Cost Electromagnetic Flowmeter,China supplier 4-20ma output digital Magnetic Water Flow Meter Priceto the world leading level. To be frank, the accuracy of our products is double higher than the similar products in Japan.
Four pieces Electrode design(2pcs for measuring, and 2pcs for grounding), easy to install, no need to install the grounding ring; Wide range of flow measurements, range ratio reaches 20:1; Pipe size range: DN15-DN2000; Strong resistance of interference, different exciting current frequency adopted for different diameter sizes; No movable part in the measuring pipe, no pressure-loss, low requirements for straight pipelines; Five-part nonlinear modification function of sensor, automatic operation of average flow, and easy for calibration.