To facilitate the clients, further we are offer authentic range of impact & environmental recorders that is used for recording varied environment conditions during transportation, storage as well operation. These recorders are assembled and incorporated with latest gps / gprs tracking module required to record any kind of impact and generate reports so as to decrease the rate of products damaging. The various environmental factors like humidity, temperature changes, till and atmospheric pressure can be recorded in this devise and can be rectified to reduce the damaging of the products. They are capable of recording shock, vibration or any environment related impact conditions and can exactly record the time duration of the mishandling. These devices are incorporated with advance triaxial piezoelectric accelerometer technology is used for recording the exact amplitude and direction of impact that enables to set certain control measures to prevent the products from damaging further.
Shockwatch tip and tilt sensors continually monitor and/or report the conditions products are exposed to during transit, storage, and operation. Attach one of the tiltwatch family of products directly to a package or container’s exterior surface, to monitor the ‘care in handling’. Tiltwatch xtr tip indicator monitors goods that must remain upright to ensure intact delivery. Tiltwatch xtr is a single-use tip indicator that does not activate until it is at an 80o angle +/-5% from vertical. Tiltwatch plus attached to package’s exterior surface, ‘peel and stick’ pressure sensitive label, is actually three separate registers in a single tilt indicator unit, providing inexpensive 360° tilt monitoring for the entire duration of shipping transit and an unalterable record of damaging excesses.
The skid-mate is an air dampened cushioning device that provides a fast, cost effectiveand durable customized solution to protect sensitive products from shock and vibration. Theskid-mate can be easily mounted on a crate or pallet base creating an air-ride cushion in placeof hardwood skid runners eliminating the need for expensive air-ride trucks.Each color coded skid-mate corresponds to a specific load range and allows users to calculatetheir requirements simply and easily to avoid potential laboratory testing and use of expensivepackaging materials. Reduce packaging design & assembly time and cost• eliminate costly damage from handling hazards during shipment• reduce costs associated with shock and vibration damage
Woodward Easygen 3000 XT Genset Controller, 12-24 V DC, IP Rating: IP20 Woodward Easygen 5000 XT Genset Controller, 12-24 V DC, IP Rating: IP20 Woodward raised the standard in genset paralleling control and power management system with the easYgen3000XT Series controllers. These controllers come with standardized software that is simple to configure, yet easily customized for individual applications. Enhanced connectivity enables fast and secure interfacing to other controls and communications systems while the enhanced hardware is a drop-in replacement for previous generation easYgen-3000 Series Controls.
DEIF GENSET CONTROLLER Automatic Genset Controller AGC-4 Mk II The automatic genset controller AGC-4 MK II can be used as a single genset controller. Also, several AGCs can be connected in a complete power management system for synchronising projects, islanded or paralleled to the mains. The generator controller is ideal for mission-critical applications such as hospitals and data centres, and it is capable of delivering backup power in only six seconds.
'ALSTOM' Protection Relay MODEL NO:- P94VP16A7C0540A; Advanced Transformer Protection, Control and Condition Monitoring Transformers are high capital cost assets in electrical power systems. Internal faults are a risk for all transformers, with short-circuits dissipating the highest localised energy. Unless cleared quickly, the possibility of rewinding will diminish and core damage may become irreparable.The MiCOM Agile P642, P643 and P645 address all these issues - preserving service life and offering fast protection for transformer faults. A transient bias technique has been included, enhancing relay stability and CT requirements. CT saturation and no gap detection techniques have been included to improve the low set differential element operating time during CT saturation where the second harmonic blocking might be asserted. An external fault detection algorithm has been incorporated to prevent the CT saturation and no gap detection from affecting the second harmonic blocking .
ALSTOM GBCDG31EG014SDCH NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E Model No - CDG31EG014SD(M) RELAY TYPE - CDG 31 APPLICATION - 2 O/C + 1 E/F BURDEN / D.M.T - 3 VA / 1.3 SEC C.T. SECONDARY - 1 AMP CT. CASE SIZE - 3D HORZ. CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R E/F SETTING - 0.1 - 0.4 Amps FLAG - YES FREQUENCY - 50 HZ MOUNTING - FLUSH O/C SETTING - 0.5 - 2 Amps. NAME PLATE - RFG9125 901 Outline Diagram MFJ 014 Wiring Diagram MADZ802.64-1
ALSTOM GBCDG31EG604SBCH NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E Technical Details RELAY TYPE - CDG 31 Model No - CDG31EG604SBCH Application - 2 O/C + 1 E/F Case Size - 3D HORZ. C.T. Secondary - 1 Amp O/C Setting - 0.5 - 2 Amps. E/F Setting - 0.1 - 0.4 Amps. Burden /D.M.T - 3 VA /3 Sec. Taps - Std Contacts - 3 N/O S/R Output Contacts - 2 N/O S/R Flag - Yes Frequency - 60 Hz Mounting - Flush Write in Name Plate As 60 Hz instead of 50 Hz. Name Plate - RFG9126 901 Outline Diagram MFJ014 Wiring Diagram MADZ802.63-1
GBCDG31EG8101LCH INV TIME 3O/C OR 2O/C &1E/FT RELAY AC SE Model No - CDG31EG8101L(M) RELAY TYPE - CDG31S/T APPLICATION - 2 O/C + 1 E/F BURDEN / D.M.T - 3 VA / 3 SEC. C.T. SECONDARY - 5 AMP C.T. CASE SIZE - 3D HORZ. CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R E/F SETTING - 1 - 4 Amps. FLAG - YES FREQUENCY - 50 HZ MOUNTING - FLUSH O/C SETTING - 2.5 - 10 Amps. Name Plate - RFG9126 904 Outline Diagram MFJ014 Wiring Diagram MADZ821-17
ALSTOM GBCDG31EG8102LCH INV TIME 3O/C OR 2O/C &1E/FT RELAY AC SE Model No : - CDG31EG8102L(M) RELAY TYPE - CDG31S/T APPLICATION - 2 O/C + 1 E/F BURDEN / D.M.T - 3 VA / 3 SEC. C.T. SECONDARY - 5 AMP C.T. CASE SIZE - 3D HORZ. CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R E/F SETTING - 0.5 - 2 Amps. FLAG - YES FREQUENCY - 50 HZ MOUNTING - FLUSH O/C SETTING - 2.5 - 10 Amps. Name Plate - RFG9126 903 Outline Diagram MFJ014 Wiring Diagram MADZ821-17
ALSTOM GBCDG31EG8111LCH INV TIME 3O/C OR 2O/C &1E/FT RELAY AC SE TECHNICAL SPECIFIFICATION Model No : CDG31EG8111LCH CDG31S/T APPLICATION - 2 O/C + 1 E/F BURDEN / D.M.T - 3 VA / 1.3 SEC. C.T. SECONDARY - 5 AMP C.T. CASE SIZE - 3D HORZ. CONTACTS (S/R OR H/R) - 2 N/O 2 N/C H/R E/F SETTING - 1 - 4 Amps. FLAG - YES FREQUENCY - 50 HZ MOUNTING - FLUSH O/C SETTING - 2.5 - 10 Amps Name Plate - RFG9125 904 Outline Diagram MFJ014 Wiring Diagram MADZ821-17
ALSTOM GBCDG31EG8114LCH INV TIME 3O/C OR 2O/C &1E/FT RELAY AC SE TECHNICAL SPECIFIFICATION Model No : CDG31EG8114LCH CDG31 Ac Series Trip Application - 2 O/C + 1 E/F Case Size - 3D Horz C.T. Secondary - 1 Amp Burden / D.M.T - 3 Va / 1.3 Sec O/C Setting - 0.5 - 2 Amps Tap - Std. E/F Setting - 0.1 - 0.4 Amps Contacts - 2 N/O 2 N/C H/R Flag - Yes Frequency - 50 Hz Mounting - Flush Name Plate - RFG9125 901 Outline Diagram MFJ014 Wiring Diagram MADZ821-17
ALSTOM GBCDG31FF001SBCH NON DIRECTIONAL INV TIME 3O/C OR 2O/C&1E Technical Specifications Model No - CDG31FF001SB(M) RELAY TYPE - CDG 31 APPLICATION - 2 O/C + 1 E/F BURDEN / D.M.T - 3 VA / 3 SEC. C.T. SECONDARY - 5 AMP C.T. CASE SIZE - 3D VERT. CONTACTS (S/R OR H/R) - 2 N/O S/R E/F SETTING - 1 - 4 Amps. FLAG - YES FREQUENCY - 50 HZ MOUNTING - FLUSH O/C SETTING - 2.5 - 10 Amps. NAME PLATE - RFG9126 904 Outline Diagram MFJ 013 Wiring Diagram MFDZ801-101-1
Alstom Gbcdg31ff001scch Idmt 3 O/c Relays Relay Model Cdg31ff001scch Cdg31 Application 3 O/c Burden / D.m.t 3 Va / 3 Sec. C.t. Secondary 5 Amp C.t. Case Size 3d Vert. Contacts (S/r or H/r) 2 N/o 2 N/c H/r Flag Yes Frequency 50 Hz Mounting Flush O/c Setting 2.5 - 10 Amps. Name Plate-1 Rfg9126674 Outline Drawing Mfj013 Wiring Diagram Mfdz801-103-1
ALSTOM GBCDG61EG006SXCH IDMT THREE O/C RELAY WITH HIGH-SET Technical specification Relay model no CDG61EG006SXCH Relay type CDG 61 Case size 3D HOR.30T Application O/C Current setting - O/C 0.5 to 2 amps Contacts 3M S/R Output contacts 2M S/R C.T.Secondary 1 amps Taps Std Frequency 50 Hz Burden 3 VA Operating time 3 secs Flag Yes High set - O/C Setting 4 to 16 amps High set/High set contact CAG 13 / 2M S/R Name plate RFG9126 771 Outline drawing MFJ 014 Wiring diagram MADZ 821.27-1
GBCDG61EG011SGCH IDMT 3 O/C OR 2O/C& 1 E/F RELAY WITH HI Technical specification Relay model no CDG61EG011SGCH Relay type CDG 61 Case size 3D HOR. Application 2 O/C & 1 E/F Current setting - O/C 2.5 to 10 amps Contacts 3M S/R Output contacts 2M S/R C.T.Secondary 5 amps Taps / Frequency STD / 50 Hz Burden 3 VA Operating time 3 secs Flag Yes Current setting - E/F 1 to 4 amps High set - O/C Setting 20 to 80 amps High set - E/F Setting 10 to 40 amps High set/High set contact CAG 13 / 2M S/R Name plate RFG9126 904 Outline drawing MFJ 014 Wiring diagram MADZ 821.27-1
ALSTOM Reverse Power Relay CCUM 21 High Res GBCCUM21PF101A DEFINITE TIME REVERSE POWER RELAY Technical Specifications Model No : CCUM21PF101A CCUM21 AUX. CURRENT OR VOLTAGE - 24V DC C.T. SECONDARY - 5 AMP C.T. CASE SIZE - 1-1/2D VERT. 10T CONTACTS (S/R OR H/R) - 2 N/O S/R FLAG - YES FREQUENCY - 50 HZ MOUNTING - FLUSH MTA PHASE-CHAR ANGLE - 30 DEGREES TIME DELAY P/U OR D/O - 0.5 - 5 SECS. V.T/P.T SECONDARY - 110V AC External Resistor Name Plate RFH9072-604 RZF9151-601 Outline Diagram MFJ013 Wiring Diagram MPDZ609-01-1
ALSTOM Reverse Power Relay CCUM 21 High Res GBCCUM21PF103A DEFINITE TIME REVERSE POWER RELAY Technical Specifications Model No : CCUM21PF103A CCUM21 AUX. CURRENT OR VOLTAGE - 24V DC C.T. SECONDARY - 5 AMP C.T. CASE SIZE - 1-1/2D VERT. 10T CONTACTS (S/R OR H/R) - 2 N/O S/R FLAG - YES FREQUENCY - 50 HZ MOUNTING - FLUSH MTA PHASE-CHAR ANGLE - 30 DEGREES TIME DELAY P/U OR D/O - 2.5 - 25 SECS. V.T/P.T SECONDARY - 110V AC External Resistor Name Plate RFH9072-604 RZF9151-601 Outline Diagram MFJ013 Wiring Diagram MPDZ609-01-1
ALSTOM Reverse Power Relay CCUM 21 High Res GBCCUM21PF104A DEFINITE TIME REVERSE POWER RELAY WITH S Technical Specifications Model No : CCUM21PF104A CCUM21 AUX. CURRENT OR VOLTAGE - 24 V DC C.T. SECONDARY - 5 AMP C.T. CASE SIZE - 1-1/2D VERT. 10T CONTACTS (S/R OR H/R) - 2 N/O S/R FLAG - YES FREQUENCY - 50 HZ MOUNTING - FLUSH MTA PHASE-CHAR ANGLE - 30 DEGREES TIME DELAY P/U OR D/O - 6 - 60 SECS V.T/P.T SECONDARY - 110 V AC External Resistor Name Plate RFH9072-604 RZF9151-601 Outline Diagram MFJ013 Wiring Diagram MPDZ609-01-1
ALSTOM Reverse Power Relay CCUM 21 High Res GBCCUM21PF106A DEFINITE TIME REVERSE POWER RELAY RELAY MODEL CCUM21PF106A CCUM21 AUX. CURRENT OR VOLTAGE 24V DC C.T. SECONDARY 5 AMP C.T. CASE SIZE 1-1/2D VERT. 10T CONTACTS (S/R OR H/R) 1 N/O 1 N/C S/R FLAG YES FREQUENCY 50 HZ MOUNTING FLUSH MTA PHASE-CHAR ANGLE 30 DEGREES TIME DELAY P/U OR D/O 0.5 - 5 SECS. V.T/P.T SECONDARY 110V AC NAME PLATE-2 RZF9151-601 NAME PLATE-1 RFH9072-604 OUTLINE DRAWING MFJ013 WIRING DIAGRAM MPDZ609-01-2