Cylindrical inductive proximity sensor: 1, diameter form m4 to m30. Max and min lengths available. 2, cable and connector type optional, rectangle inductive proximity sensor: 1, from size 7*7mm to 210*210mm 2, steady performance due to professional ic design 3, short-circuit, reverse polarity protection 4, widely application such as limit and counter function Plastic bay and box
Plastic column inductive proximtiy sensor 1, easy to adjust due to long-rang sensing distance 2, short-circuit, reverse polarity and surge protection. 3, strong power supply: dc:10...30v, ac: 20...250v 4, ip67(iec) Plastic bay and box
Humidity measuring range: 1%rh~ 99 %rh Supply voltage vs: 10 v Time constant (33 to 80 % rh, still air @ 63%) ta: 3.5 s Deviation to typical response curve (10% to 90%) rh) :+/-2 %rh
A) voltage supply: 5 vdc B) humidity measuring range: 0~100 %rh C) response time (at 63% of signal) 33%rh to 75%rh(3): 5 s D) suitable for small bulk assembly E) reliability not affected by repeated condensations F) full interchangeability. Better than +/-3%rh and +/-0.15oc G) demonstrated reliability and long term stability H) typical 1 to 3.6 volt dc output for 0 to 100% rh at 5 v dc supply I) humidity calibrated within +/- 3% rh @ 55% rh J) temperature measurement through ntc 10 kª+ +/- 1% direct output K) ratiometric to voltage supply within the specified range
Parameter specification : 1 switching capability 10 w (max) 2 switching voltage 100 vdc (max) 3 switching current 0.5 amps (max) 4 contact resistance 1 ohms max 5 dielectric : between terminals 200vdc for 1minute between body & terminal 500vdc for 1minute body & cable insulation 500vdc for 1minute 6 must operating distance 7- 14 mm with tvsc magnet tvsc-mfax-01 7 must release distance 10-25 mm with tvsc magnet tvsc-mfax-01 8 operating temperature 80 deg c max 9 surface temperature 5 deg c max @ ambient 10 ambient temperature -20 to +50 deg c x denotes for high temperature (50 deg c ) 11 IP rating ip 67. 12 sensor dimension 35x19x10 mm 13 Cable 2 core cable with shield 14 Approvals : CE & Atex.
Application: for hydrogen detection; Suitable for people who working in hydrogen environment to improve safety and reliability; With PID light the system is good for all day-long use Power Supply: one 9 Volts Battery Response time: < 3s Recovering Time: 1% Working temperature: 0 íµ - 90 íµ Dimensions: 58 mm 48 mm 113 mm.
1. Center frequency: 40ía1.0khz 2. Echo sensitivity: í²200mv 3. Decay time: ín1.2 ms 4. Directivity: x-axis 110ía15íp Y-axis 75ía10íp 5. Capacitance: 2000ía15%pf 6. Input voltage: ín140vp-p 40khz, pulse width 0.5ms, interval 20ms 7. Mean time to failure : 50000h 8. Operating temperature: -40í½+80íµ 9. Storage temperature: -40í½+85íµ
Features: 1. After entering í¦Rí¦ grade, the system will work automatically. 2. The sensor's sensitivity is 2~3 times better than others. It can even detect 2mm steel wire. The detection error is í_2 cm. 3. Detecting distance is 0.30-2.50m.It has wide detection angle and less blind zone 4. It measures 4 times /second. It can react to quickly moving objectives. 5. It can operate in rainy, snowy and foggy days. It has high anti-electromagnetism. 6. Clear display, self-locking connection, inlay sensor fitting, and anti-mistake distance measuring technology. 7. The product service life is longer than automobile service life. It has 3 years guarantee. 8. It has 4-way sensor. The standard cable of display is 5m. Technical data: 1. Working voltage: DC10V~15V 2. Max. Power: 2W 3. Working temperature: -30íµ~ +70íµ 4. Detecting distance: 0.30m ~ 2.50m 5. Measuring error: í+0.02m 6. Alarming Volume of external Siren: 60dB 7. Response Time: 250ms 8. Ultrasonic Frequency: 40KHz 9. Current Consumption:
Spo2 sensor Compatible to all nellcor monitor series without oximax technology. This model is not oximax compatible. 1 pc per box with user instruction sheet
4.Electrical characteristics 4.1 input power: 1vac (sine wave), 1khz 4.2 operating temperature range: -20=j ~ 70=j 4.3 operating humidity range: 95 %rh or less 4.5 accuracy: f+5 %rh (at 25=j, 60 %rh) 4.6 hysteresis: within 2 %rh (40 %rh ~ 80 %rh) 4.7 stability: 1 year < 2 %rh 500pcs/bag 10000pcs/carton
Smoke sensor Wired/wireless defense zones, which are compatible Diy project users can add/delete detectors/sensors freely Has many arming methods such as away arming, stay arming, -hour arming, away/stay arming and separate arming Long distance operation to the main panel by password Can freely select entry delay timer, exit delay timer, the time of siren sounds Program alarming phone numbers, can alarm automatically when the phone line is disconnected or destroyed record message for seconds Time auto-adjusted with fsk caller id All the info stored will not lose when power off Can store items info about arming, disarming, alarming and the number of remote controls, the type and number of detectors and so on Support connecting to monitoring receive center with ademco contact id, bsia fast format protocol Built in ni-h chargeable battery auto chargeable/ dischargeable Built in db siren, wired/wireless siren selected mute alarm and audible alarm is at user's option
Tilt sensor 1.Measuring range1p2p5p10p15p30p45p60p70p 2.The highest resolution0.0003p 3.Degree of accuracy0.0010.0020.0030.0050.010.020.030.050.1 4.Linearity error
Torque sensor
Discription: CJBPZ-I all-in one vibration sensor integrates piezoelectric acceleration sensor with precision measuring circuit that composes high precision vibration measure system. The sensor can connect with DCS, PLC or other equioment directly. It is ideal for measuring vibration of fan, motor, water pump factory equipment etc. Features: Wide measure range All material is Stainless steel Various port type Protection Grade: IP65 Performance Parameters: Frequency Response: 5-1000Hz Natural Frequency of Vibration: 10Hz Measurement Range: Displacement Range: 0-200um, 0- 500um, 0-1000um (opitional) Speed Range: 0-10.0mm/s,0-20.0mm/s, 0-100.0mm/s (optional) Working Voltage: 24V DC Output Currency: 4-20mA Output Impedance: â?¤500 Signal line Specification: wires (DV24V power supply&4-20mA output uses these 2 wires together) 3 wires (earth wire, power supply wire, output wire) Max Acceleration: 10g Measurement Direction: vertical or horizontal Working Ambient: Temperature: -40°C to 85°C, Relative humidity â?¤90% Size: Ï?45Ã?80ï¼?mmï¼? Weight: 450g Thread: M10Ã?1.5 Protection Grade IP65
We are proud to say that for the first time in India, we are launching Battery temperature sensors for commercial purposes. The specialty of the sensor is that we can measure the in situ temperature. So far, the widely popular technique is to monitor the battery temperature by placing a sensor adjacent to it. As expected, the accuracy of this method is not up to the mark. Now with the advent of Arcotherm's unique sensors, more accurate values can be obtained. Currently, we are exporting these to the European market.
We manufacture Automobile Industry related temperature sensors. In BULK: 1) Automatic transmission (position sensor and ATF temperature sensor) 2) Motor temperature sensor 3)Battery temperature sensor/ current senso 4) Exhaust gas temperature sensor (recirculation) 5) Ambient air temperature sensor 6) Steering wheel and seat heat temperature sensor 7) Air duct temperature sensor
PCFS-IR2125A level sensor contact type, it is used for tube. The principle is infrared, output signal is analog. When there is no water, the sensor outputs low voltage value; When there is water, the sensor outputs a high voltage signal. The size can be customized. The photoelectric liquid level switch has high precision, low price, high reliability and wide application environment, it is less affected by strong acid, alkali and viscosity. Photoelectric level sensors can be used for higher liquid level accuracy requirements.
Alphasense now provides a solution to some old problems: * Palmes-type diffusion tubes are commonly used for indicative measurement of nitrogen dioxide (NO2) in cities for Local Air Quality Management. But sampling over several weeks gives only one average concentration for the entire sampling period and the result is reported weeks after the measurement. * Odours which were previously ignored by local industry and city councils are now headline problems. There is a growing requirement to monitor odour plumes around landfills, waste water treatment plants, agricultural/ poultry farms and industrial sites- but the cost of the necessary network of monitoring nodes is prohibitive. Hydrogen sulfide (H2S) or ammonia (NH3) are the two mot commonly measured gases for odour detection. Alphasense introduces the Electronic Diffusion Tube (EDT): a single gas data logger with ppb resolution using the proven Alphasense A4 family of electrochemical ppb gas sensors. EDT-01 Electronic Diffusio n Tube Features include: The low cost EDT makes networks affordable User- adjustable logging interval from one minute to four hours Also records relative humidity and ambient temperature * Eight months battery life from two Lithium AA cells * Data is downloaded in seconds via Bluetooth to the Android smart phone app * Designed for waterproof to IP 67 * Mounting bracket connects easily to both walls and poles * Gases include NO2 , NO2 + O3, H2S, NH3 and CO. Sensor data sheets specify performance. Data analysis support available EDT-01 Electronic Diffusion Tube SPECIFICATION * Range: 0-5 ppm (NO2) 0-50 ppm (H2S) 0-500 ppm (CO) 0-100 ppm (NH3) * Temperature range: -20 to +50 'C * Humidity range: 10 to 90%rh continuous * Temp. accuracy: ±0.5'C (-20 to +50'C) * Sampling time: 1 to 256 min EDT-01 Electronic Diffusion Tube Applications include: * Co-locating with Palmes-type diffusion tubes to record diurnal and weekly patterns and peaks * Monitoring urban construction sites for compliance, especially for peak concentrations * Ring-fencing odour sources for plume monitoring- daily downloads provide regular feedback * Tracking ammonia plumes on poultry farms * Detecting fugitive emissions from industrial sites for both leak detection and ensuring compliance * Low cost educational tool when teaching about air quality
SICK connects - complete connectivity from a single source. SICK provides connection devices that easily connect to other devices in your machine, regardless of the selected automatic identification technology. These devices enable easy integration of field bus gateways into the modular connection boxes, making it possible to incorporate the scanner, camera or RFID systems into different field bus technologies. A field bus proxy, external parameter memory, display, and power modules provide a high degree of application flexibility. At A Glance: Connection module for one ID pro sensor Clearly visible, easily accessible screw- and spring-loaded terminals Connection diagram on the inside of the lid Configuration with switches IP 65 connection for one ID pro sensor using standard connection cable Basis for CMC600 parameter cloning module Service plug for direct access to the AUX interface Your benefits: Compact design fits into small spaces Two mounting holes for fast, precise installation saves on installation costs Clearly labeled, easily accessible screw- and spring-loaded terminals save time when connecting to peripherals Quick, easy configuration with switches reduces installation time Industrial-standard connection guarantees a reliable application solution CMC600 parameter cloning module allows rapid exchange and replacement of connected sensors Product Family: In this type of sensors CDM, CDF, CDB series are available. Protection Class Protection class can be up to IP69K.
NH3-3E100SE Ammonia Sensor NH3 Sensor Description NH3-3E100SE Ammonia Sensor, 3 Electrode sensor; available in Mini, Classic, 4-Series and 7-Series formats. NH3-3E100SE Ammonia Sensor NH3 Sensor FEATURES * Amperometric 3 electrode sensor cell * Very stable zero reading * Very selective * Highly sensitive * Hydrous electrolyte NH3-3E100SE Ammonia Sensor NH3 Sensor TYPICAL APPLICATIONS * TLV-monitoring, leakage detection * portable & fixed point applications * Food & Refrigeration Industry, General Industry, Semiconductor Industry NH3-3E100SE Ammonia Sensor NH3 Sensor TECHNICAL SPECIFICATIONS * Measuring Range: 0-100 ppm * Sensitivity Range: 130 nA/ppm ± 30 nA/ppm * Resolution at 20°C: < 1 ppm * Linearity: < 10% full scale * Operation Temperature Range: -20°C to +40°C * Operation Humidity Range: 15-90% r.H, non-condensing