Application: for hydrogen detection; Suitable for people who working in hydrogen environment to improve safety and reliability; With PID light the system is good for all day-long use Power Supply: one 9 Volts Battery
Response time: < 3s
Recovering Time: <3s
Minimum concentration: >1%
Working temperature: 0 íµ - 90 íµ Dimensions: 58 mm 48 mm 113 mm.
MICROceL HS Hydrogen Sulfide Sensor (H2S Sensor) Description MICRO 3-electrode hydrogen sulphide sensor MICROceL HS Hydrogen Sulfide Sensor (H2S Sensor) Key Features & Benefits * A robust hydrogen sulfide sensor suitable for portable life safety applications * Extremely small size MICROceL HS Hydrogen Sulfide Sensor (H2S Sensor) Technical Specifications * Operating Principle: 3-electrode electrochemical * Measurement Range: 0-100 ppm H2S * Sensitivity: 0.105 ± 0.025 µA/ppm * T50 Response Time:
Supplier: 1. sensor products, includes hydrogen sensor and pressure sensors 2. voltage regulator of alternator 3. module of voltage regulator 4. ic
Supplier: Hydrogen sensors, small-scale fuel-cell stack, fuel cell testing system, fuel cell analysis system, series of constant-current electronic load, micro-gas pressure safety valve
Ulpsm-h2s 968-003 ultra-low power analog h2s sensor module description Quickly integrate hydrogen sulfide sensing into your system with very low power consumption and a simple analog sensor signal output. The ulpsm converts the hydrogen sulfide sensors linear current signal output to a linear voltage signal, while maintaining the sensor at its ideal biased operation settings. Ulpsm-h2s 968-003 ultra-low power analog h2s sensor module benefits 0 to 3 v analog signal output Low power consumption < 45 uw Fast response On-board temperature sensor Easy sensor replacement Standard 8-pin connector Ulpsm-h2s 968-003 ultra-low power analog h2s sensor module applications Fixed industrial safety monitoring Portable industrial safety monitoring Portable personal safety monitor Indoor air quality monitoring Outdoor air quality monitoring Bad breath/halitosis sensing Ulpsm-h2s 968-003 ultra-low power analog h2s sensor module performance characteristics Measurement range: 0 to 50 ppm Lower detection limit: 0.3 ppm Resolution: 0.15 ppm Accuracy: < â± 2 % of reading Response time t90: < 30 seconds Power-on stabilization time: 60 minutes recommended
Gas leak detection in stationary fuel cells combustible gas sensor module Model number:cgm6812--b00 Features: * linear analog output proportional to gas Concentration * maintenance free * compact size * meets rohs requirements Applications: * gas leak detection in fuel cell systems * hydrogen & combustible gas leak Detectors Description: The cgm6812-b00 combustible gas sensor module is A new unit which utilizes tgs6812, figaro's catalytic Pellistor type gas sensor which features durability and stability. This module provides analog output voltage proportional to hydrogen gas concentration. Cgm6812-b00 has conformal coatings for moisture- Proofing and electrical insulation purposes, and is also Capable of detecting sensor wire breakage. The unit has A wide range of operating temperature from -10' to +60'c. Because the tgs6812 sensor can detect methane and lp gas As well as hydrogen, this module is suitable for gas Leak detection in stationary fuel cells which use hydrogen Generated from combustible gases Sensor Module Cgm6812
Cheap voc sensor for air purifiers and ventilation system tgs2600 Model number: tgs2600 1.Features: * low power consumption * high sensitivity to gaseous air contaminants * long life and low cost * uses simple electrical circuit * small size 2.Description The sensing element is comprised of a metal oxide semiconductor layer formed on an alumina substrate of a sensing chip together with an integrated heater. In the presence of a detectable gas, the sensor's conductivity increases depending on the gas concentration in the air. A simple electrical circuit can convert the change in conductivity to an output signal which corresponds to the gas concentration. The tgs 2600 has high sensitivity to low concentrations of gaseous air contaminants such as hydrogen and carbon monoxide which exist in cigarette smoke. The sensor can detect hydrogen at a level of several ppm. Due to miniaturization of the sensing chip, tgs 2600 requires a heater current of only 42ma and the device is housed in a standard to-5 package. 3 applications * air cleaners * ventilation control * air quality m onitors
Fsm-t-04a combustible gas sensor module description The fsm-t-04a combustible gas sensor module is a new unit which utilizes tgs6812, catalytic pellistor type gas sensor which features durability and stability. This module provides analog output voltage proportional to hydrogen gas concentration.(there is a memory in module, where factory calibration data has been store). Fsm-t-04a has conformal coatings for moisture proofing and electrical insulation purposes, and is also capable of detecting sensor wire breakage. The unit has a wide range of operating temperature from -10 to +70'c. Furthermore, the unit can detect ch4, lpg, h2. It is less sensitivity to vocs gas, it immunes poison by silicon compounds, it suits to work at rugged environment. Fsm-t-04a combustible gas sensor module features: * linear analog output proportional to gas concentration * maintenance free * compact size * meets rohs requirements Fsm-t-04a combustible gas sensor module applications: * gas leak detection in fuel cell systems * hydrogen & combustible gas leak detectors Fsm-t-04a combustible gas sensor module specification * gas sensor: tgs6812 (catalyâ??tic type) * detection range: 0 ~ 50, 000ppm ch4 * error: 3%lel * response time (t90): 30s * operating temperature: -10'c ~ +70'c * operating humidity: 20~95%rh (no condensing) * input voltage: 5.00.2v dc, 3.00.1v dc * power consumption: 1.5w
IoLine High Performance pH Electrodes Iodine glass pH electrodes with temperature sensor IoLine-HPB IoLine High Performance pH Electrodes Description The IoLine high performance pH electrodes use a patented three chamber system with an iodine reservoir in the iodine/iodide reference electrode. The standard hydrogen electrode has proven too difficult in practical use to gain more than a mere theoretical importance. The Ag/AgCl reference system, which is the most common reference system, can cause measuring instabilities originating from potential variations with changing temperature or reactions between silver ions and the measuring solution in the area of the diaphragm. IoLine pH electrodes, in contrast, have the advantage of a much lower temperature sensitivity and a metal ion free reference system. IoLine-HPB IoLine High Performance pH Electrodes Features * Unique iodine/iodide reference system * Tris buffer compatible * Exchangeable bridge electrolyte * Integrated refill port * Excellent for a wide range of applications * Integrated temperature sensor IoLine-HPB IoLine High Performance pH Electrodes Specifications * pH Range: 0 to 14 * Temperature Range: 23 to +212'F (-5 to +100'C) * Shaft: Glass * Zero Point: pH = 7.00 +/- 0.25 * Reference System: iodine/iodide
Nap-50a is a miniature & low power consumption type sensor. Nap-50a is Mainly used for gas detectors. Compared to nap-55a, nap-50a has a lower Alcohol sensitivity to eliminate false alarms caused by alcohol, thus more reliable Gas detectors can be produced with nap-50a. The following are the basic Characteristics but it is recommended to refer to the individual user’s manual for Further information. See nap-66a for measuring circuit for sensor evaluation. Target gases and concentration GasesDetection range MethaneCh40.05 - 5% (0.05 - 2%) EthaneC2h60.05 - 3.2% (0.05 - 1.5%) HydrogenH20.05 - 4% (0.05 - 1.5%) HydrocarbonsCnh2n+21 - 100%lel (1 - 50%lel) ( )is a detection range in high accuracy Gas sensitivity characteristics Gas & concentrationOutput voltage Output in clean air-35 - +35 mv Methane 3, 000 ppm10 - 16 mv Hydrogen 1, 400 ppm7 - 12 mv Ethanol 1 %Less than 10 mv Ratings ItemsRatings Supply voltageDc 2.5±0.25v Ac 2.5±0.25v(r.M.S. 50-60hz) Current (2.5v supplied)Dc 150 - 170ma Ac 150 - 170ma(r.M.S. 50-60hz) Ambient temperatureIn operation -10 - +50°c In storage -10 - +50°c Ambient humidityIn operation 95%rh or less In storage 99%rh or less(no dew condensation)