RCCB: CL7 (Magnetic type) Type: AC, A No. of poles: 2P, 4P 6KA at 230/400V In: 10A, 16A, 25A, 32A, 40A, 63A, 80A, 100A, 125A n: 10mA, 30mA, 100mA, 300mA, 500mA. 50pcs/ctn for 4p. 100pcs/ctn for 2p.
Characteristics: Standard: IEC60898 Rated current In (A): 1,2,3,4,6,10,13,16,20,25,32,40,50,63 Rated voltage Ue (V): 230/400 Poles: 1P, 1P+N, 2P, 3P, 3P+N4P Rated insulation voltage Ui (V): 500 Rated impulse withstand voltage (V): 6000 Rated breaking capacity: 10KA Rated frequency: 50/60Hz Trip curve: B, C, D Thermal operating limit: (1.13~1.45)¡ÁIn Energy limiting cass: 3 Mechanical lfe: 20 000 Electrical lfe: 4000 Mount: on 35mm DIN rail. The Gross weight 14kg The dimension 46.5*23.5*17 cm M.O.Q 500pcs (Samples Excepted) Payment term T/T, L/C,D/P,O.A Delivery time Usually 25 days (Negotiable for different order quantity) Promote the products with our own brand (As one of our agents in your market) Promote the products with neutral packing.
MCB 6A - 32A 1Pole Make: LS, Korea. 12.
ST Series of wall mounting metal cabinet Features: 1) Construction: A) Body and door manufactured in 1. 5mm sheet steel. B) Flat mounting plate in 2. 5mm sheet steel 2) Finish A) Case and door RAL 7032 textured finish B) Mounting plate in RAL 2004 smooth finish 3) Protection degree: IP65 to EN60 529 NEMA 4
SG2008 Automatic 12kV Capacitance & Dissipation Factor Test Set is designed to measure dissipation (Dielectric Loss Angle tgª-) or power factor (cosª+) in heavy electromagnetic interference environment such as in power plants or substations. Also it can be used in laboratory for high accurate test. The test set is all-in-one structure: including precision digital bridge, 12kV/200mA frequency conversion power unit, reference capacitor (CN), and other electronic circuits. An external power supply can expand the test range. True portability is realized by the lightweight. Simple usage is realized by the full automation. High performance is realized by the digital process. We can also provide the professional solutions and equipments for: withstanding voltage testing, c & tan-delta (power factor) testing, partial discharge (PD) testing and impulse voltage testing.
òConstructed of super nylon. òIn front of the lockout,90¦curved mental hook sets on left and right respectively, used for plug in the two holes of power switch. òUsed for open circuit breaker or closed circuit breaker.
HKKC1L Series of Mini. Breakers HKKC1L-63 series of residual Mini breakers is mainly used in AC. 50Hz/60Hz, rated voltage up to 400V below lines to protect load/lines from over-load, short-circuit and Elec. leakage. The product has a beautiful out-looking, light weight, perfect & reliable Elec. performances, high breaking capacity, rapid tripping and reliable mounting channel
CHZ series vacuum auto-recloser utilizes the model ZW7-40.5 circuit breaker and high-reliable MGK intelligent controller. The auto-recloser is designed mainly applying on the medium-voltage overhead distribution lines as well as substations, it is used to make & break the load current, overload current and short-circuit current, also auto-reclosing up to three times. 200~400KG
3VL MCCB 3VL series MCCB is one of our new products developed and manufactured by adopting international advanced technology. It is supplied with rated insutaling voltage 690V and used for circuit of A.C.50/60Hz, rated operating voltage A.C. 415V or below, rated operating current from 16A to 250A. It is designed for protection of electric circuit, motors, transformers and other equipments. The products conforms to GB14048.4, IEC60947-1, IEC60947-2 & VDE0660 standards.
Graphic overlays
Circuit breaker
Vacuum interrupters Hanguang electron device factory(4404), has been manufacturing wide range of high quality vaccum interrupters for medium and high voltage switch circle in china since 1969's. Outstanding vacuum interrupter manufactleader techniques used by hanguang result in the highest quality and the largest voltage range of vacuum interrupters available today.
4P 63A RCCB Brand: Indoasian Rated Voltage: 415V Model No: IPF63301
POCT (Smart Power-Free Shockproof Overcurrent Trip) POCT is like a vaccine for power accidents. It can accurately detect the fault current and trip the circuit breaker within 0.02 seconds (faster than IEEE-39.07 std. 0.025~0.033 seconds), effectively avoiding the expansion of short-circuit accidents. The high-voltage circuit breakers in the world can only trip when there is control/working power supply. But Long Men POCT can work without power POCT completed all functions and seismic verification and certification in 2018, wining glory for Taiwan. So far, it has obtained invention 12 patents in 10 countries (U.S.A, U. K., Germany, France, Russia, India, China, Japan, South Korea, Taiwan) and 10 awards from 6 countries.
EZ9R36225 // Easy9 Residual Current Circuit Breaker - 2P - 25 A - 30 mA - AC type - 230 V EZ9F56232 // Miniature circuit breaker, Easy9, 2P, 32 A, C curve, 6000 A
Miniature circuit breaker - Acti 9 xC60 MCBs Acti 9 xC60 Miniature Circuit Breaker (MCB) up to 63 A (MCB)
MCB 6A to 63 A - 6KA & 10KA : - 1P, 1PN, 2P, 3P, 3PN,4P.
Jovean&Rogy electrical is the specialized manufacturer of modular electric terminal devices for household and similar installations. We selling MCB,RCBO,RCCB,Switch-disconnector,Distribution Box etc.Ourproduct passed lab.test and obtained safety approvals:CE(Europe),S(SEMKO Sweden),B(Poland),CCC(China),CB,TUV(Germany),DVE(Germany),KEMAEUR(Netheland),UL(USA),IRAM(Argentina) contact with me for more information . YongYi Zheng, zhengyy(at)rogy(dot)cn Thanks
Provide Miniature Circuit Breaker, contact zhengyy@rogy.cn for more information. Pole No:1,1P+N,2,3,3P+N,4 Rated voltage:AC 230/400V Rated current(A): 1,2,3,4,6,10,13,16,20,25,32,40,50,63
MCB enclose waterprrof box: 1.4P or 8P; 2.Material:PC or ABS; 3.IP66; 4.With MCB or without MCB. info@new-pv.com http://www.new-pv.com/products_show.asp?id=220