Transport tubes, sometimes called mailing tubes, are used in multiple sectors of the laboratory market, including environmental, independent testing, food testing, and biological research labs. PekyBio's transport tubes are made from polypropylene (PP), and screw caps are Polyethylene (PE). Tubes are self-standing with conical bottom and molded graduations. Vailable in 5 mL and 10 mL, non-sterile and gamma radiation sterilized.
LYBCON Vacutainer GEL-SST Advance tubes During the centrifugation of the LYBCON Vacutainer GEL-SST Advance tubes, an inert LYBCON Vacutainer gel separates the serum and the blood clot preventing the contamination of the serum from the separated cellular components. For example, the serum for certain analytes such as potassium, phosphorus and glucose must be separated from the cells within a few hours - otherwise the results will be significantly distorted. Using LYBCON GEL-SST Advance tubes routine analyses in clinical chemistry such as potassium and glucose are still stable after a week of storage at 2-8 C. Clinical evaluations of special chemistry demonstrate a high degree of analyte stability with the acrylic gel in the LYBCON GEL-SST Advance, with detection of >90% of the therapeutic drugs and other special analytes(proteins/peptides, steroids and vitamins) tested. As a result of the type of gel used in the GEL-SST Advance tubes, LYBCON Vacutainer short centrifugation times of 5 minutes at 3000g can be achieved. The stability of the gel barrier is a distinct advantage during transport and storage. The main advantages of gel tubes versus non-gel tubes are: Stable barrier between serum and clotted blood, therefore better analyse stability. Better sample quality. Optimisation of the work flow: Short centrifugation time, sample processing and archiving in the primary tube. No possibility of misidentification due to the use of secondary tubes. CLOTTING TIMES The minimum recommended coagulation time for GEL-SST Advance tubes for patients who have not LYBCON Vacutainer received anticoagulation treatment is 30 minutes. CENTRIFUGING CONDITIONS 1600-2000g for 10 minutes MIXING RECOMMENDATION Serum Separation Tubes should be gently inverted 180 and back 6-8 times. EFFECTS OF TEMPERATURE LYBCON Vacutainer GEL-SST Advance should be stored at 4-25C and protected from direct sunlight during storage. Cooling of the tube by or during centrifuging can affect the movement capability of the gel. The optimum separation of serum and coagulated blood is achieved at a temperature of 20-25C. Serum Separation Tubes should be gently inverted 180 and back 6-8 times. CLOT ACTIVATOR LYBCON Vacutainer GEL-SST Advance tubes contain silica particles. SPECIFICATION Specimen: Serum Additive: Gel & Clot Activator Cap color: Dark yellow Tube Size: 13x75mm Draw Volume: 3.5mL Max. draw volume Tolerance: ±10%
CE&ISO certified professional manufacturer of medical supplies lab consumables vacutainer since2009-Hebei Chaoran Medical Instruments Vacuum blood collection tubes are applicable to the clinical blood test and the blood cells analysis The internal walls of the tubes are coated with different additives designed to stabilize and preserve the specimen prior to analytical testing *Red: Non-additive - Serum *Red: Clot Activator-Serum *Yellow: Gel & Clot Activator -Serum *Purple: ETDA K2 / ETDA K3 - Whole blood *Black: 3.8% Sodium Citrate (1:4)- Whole blood *Blue: 3.2% Sodium Citrate (1:9)- Whole blood or Plasma *Green: Lithium Heparin / Sodium Heparin-Plasma *Grey: Glucose - Plasma Material:PET plastic or Glass Tube size :13*75mmï¼?13*100mm Volume:1ml,2ml,3ml,4ml,5ml,6ml,7ml Etc Shelf Life:2years Disinfecting Type:gamma ray Sterilized:yes Band:Chaoran Sample:Availible OEM:Available Certificate:CE/ISO
CE&ISO certified manufacturer of medical supplies medical lab consumables since2009, Vacuum blood collection tubes are applicable to the clinical blood test and suitable for the blood cells analysis The internal walls of the tubes are coated with different additives designed to stabilize and preserve the specimen prior to analytical testing *Red: Non-additive Serum *Red: Clot Activator Serum *Yellow: Gel & Clot Activator Serum *Purple: ETDA K2 / ETDA K3 Whole blood *Black: 3.8% Sodium Citrate (1:4) Whole blood *Blue: 3.2% Sodium Citrate (1:9) Whole blood or Plasma *Green: Lithium Heparin / Sodium Heparin Plasma *Grey: Glucose Plasma Material:PET plastic or Glass Tube size :13*75mm,13*100mm Volume:1ml,2ml,3ml,4ml,5ml,6ml,7ml Etc Shelf Life:2years Disinfecting Type:gamma ray Sterilized:yes Brand:Chaoran Sample:Availible OEM:Available Certificate:CE/ISO
Length:144mm Certificate:CE DMF and ISO Material:PE,PP Color:Customized Logo:Customer's Logo Acceptable Printing:Customized Packaging:standard export carton or as your requriements 1.Medical grade materials and produced in GMP workshop. 2.Printing,Color,Logo can be customized. 3.Tube height range from 84mm to 144mm 4.Desiccant is silica gel or molecular sieve which can keep the tube dry 5.Anti-theft ring protects the table which is in the tube 6.Spiral caps can prevent tablets waggle and avoid tablets damaging.
Butterfly Blood Collection Set. EO STERILIZATION Single Blister Package Specification: 21G, 23G, 25G, CUSTOMIZED MOQ 100K Sterile Pack, Single use only Color coded for easy identification of needle sizes Ultra-sharp needle tip minimizes patient discomfort More comfortable double wings design, easy operation Customized sizes available 510K approved CE approved ISO
Product Details: Brand SD Biosensor Specimen Whole blood Specimen volume 1 mL Storage temperature 2-25 C / 36-77 F Cat. No 07TBF10C Blood collection vacuum tube for diagnosis of latent tuberculosis infection Intented Use Blood collection vacuum tube which is used with STANDARD E TB-Feron ELISA for diagnosis of latent tuberculosis infection Advantage Specific detection of human IFN-I related to TB Sensitive and specific IGRA test.
Product Details: Brand SD Biosensor Specimen Whole blood Specimen volume 1 mL Storage temperature 2-25 C / 36-77 F Cat No 07TBF10C Intented Use : Blood collection vacuum tube which is used with STANDARD E TB-Feron ELISA for diagnosis of latent tuberculosis infection Advantage: Specific detection of human IFN-I³ related to TB Sensitive and specific IGRA test
15 ml conical bottom centrifuge tubes (falcon type) with screw cap water and air tight. with volume graduation with sanded blurred writing area. sterile or nonsterile polypropylene excellent quality
EDTA salts (ethylene diamine tetra acetic acid) are used for the anticoagulation of whole blood for haematological investigations as the cellular components of the blood are particularly well preserved by EDTA. It works as an anticoagulant as it forms complexes with metal ions such as calcium, therefore inhibiting the coagulation cascade. Anticoagulation with EDTA is irreversible. The EDTA concentration in tubes is LYBCON Vacutainer 1.8mg per ml of complete blood when the fill level is correct, as recommended by the ICSH (International Council Society of Haematology) and the CLSI (Clinical and Laboratory standards institute). The institutes recommend dipotassium EDTA salt (K EDTA) for 2 haematological investigation. K EDTA is used in 2 LYBCON Vacutainer tubes in spray dried form.
SODIUM CITRATE Trisodium citrate is used as an anticoagulant for coagulation investigations. It works as an anticoagulant as it forms complexes with metal ions such as calcium inhibiting the coagulation cascade. Anticoagulation with trisodium citrate is reversible. LYBCON Vacutainer Citrate tubes contain buffered citrate in accordance with recommendations: 0.105 M or 0.109 M of buffered trisodium citrate solution, equivalent to 3.2% trisodium citrate The blood to additive ratio is 9:1. The citrate solution in the acts as LYBCON Vacutainer a buffer. Therefore, no additional buffer substances are added as these can adversely affect laboratory analysis. LYBCON Vacutainer Citrate tubes are also suitable for carrying out special test procedures such as the platelet function test PFA-100. Special tubes and the associated additional costs are therefore unnecessary. FILL LINE MARKING The significance of the correct ratio of blood to additive for coagulation samples is well documented. The correct fill amount is critical for correct coagulation analysis. All LYBCON Vacutainer coagulation tubes have a mark indicating the minimum fill level. CENTRIFUGING CONDITIONS For coagulation analysis different plasma specifications can be obtained from the citrated blood. Platelet rich plasma:150-200g for 5 minutes at 18-25 C Platelet poor plasma:2000-2500g for 10-15 minutes at 18-25 C Platelet free plasma: >3000g for 15-30 minutes at 18-25 C MIXING RECOMMENDATION Citrate tubes should be gently inverted 180 and back 3-4 times. SPECIFICATION Specimen: Plasma or Whole Additive: Sodium citrate 3.2% or 3.8% (9NC) Cap color: Blue Tube Size: 13x75mm Draw Volume: 1.8mL, 2.7mL Max. draw volume Tolerance: ±10%
Vacuum Blood Collection Tube/Disposable Vacuum Blood Collection Tube Blood Collection Tube Materials: PET/Glass Blood Collection Tube Size: 1ml-10ml available Additive Type available: Blood Collection Tube + No additive Blood Collection Tube + EDTA k2 Blood Collection Tube + EDTA k3 Blood Collection Tube + Heparin sodium Blood Collection Tube + Heparin lithium Blood Collection Tube + Sodium citrate1: 9 Blood Collection Tube + Sodium citrate1: 4 Blood Collection Tube + Seprate Gel+Clot activator Blood Collection Tube + Fluoride/oxalate Blood Collection Tube + Clot activator cap color normal specification material blood drawing volume packing additive red 13*75 PET 1-5ml 1200pieces/carton non 16*100 PET 8-10ml 1200pieces/carton purple 13*75 PET 1-5ml 1200pieces/carton EDTA-K3 black 8*120 glass 1.28ml 1200pieces/carton 0.129M sodium citrate 1:4 blue 13*75 PET 1.8ml 1200pieces/carton 0.109M sodium fluoride/CTAD 1:9 green 13*75 PET 1-5ml 1200pieces/carton heparin lithium yellow 13*75 PET 1-5ml 1200pieces/carton separation gel/coagulation accelerator 13*100 PET 5-7ml 1200pieces/carton Lithium Heparin/Sodium Heparin Vacuum Blood Collection Tube
CE&ISO certified professional manufacturer of medical supplies lab consumables vacutainer since2009-Hebei Chaoran Medical Instruments Vacuum blood collection tubes are applicable to the clinical blood test and the blood cells analysis The internal walls of the tubes are coated with different additives designed to stabilize and preserve the specimen prior to analytical testing *Red: Non-additive - Serum *Red: Clot Activator-Serum *Yellow: Gel & Clot Activator -Serum *Purple: ETDA K2 / ETDA K3 - Whole blood *Black: 3.8% Sodium Citrate (1:4)- Whole blood *Blue: 3.2% Sodium Citrate (1:9)- Whole blood or Plasma *Green: Lithium Heparin / Sodium Heparin-Plasma *Grey: Glucose - Plasma Material:PET plastic or Glass Tube size :13*75mm,13*100mm Volume:1ml,2ml,3ml,4ml,5ml,6ml,7ml Etc Shelf Life:2years Disinfecting Type:gamma ray Sterilized:yes Band:Chaoran Sample:Availible OEM:Available Certificate:CE/ISO
Product Name:HA prp tube 10ml Material:PET Feature: 1. Triple-sterilization 2. Non-pyrogenic 3. 2 ml non-crosslink HA 4. 2 years shelf life Draw volume:10 ml Cercificate:ISO13485, CMDEAS Label:MANSON/OEM Closure type:Safety plastic cap Additive:ACD+Sparation GEL+ 2ml Hyaluronic acid Founction Description 1.Vacauum Tube 2. Pyrogen-free, Sterile 3. ACD & GEL+HA 4. Sterile Packing 5. 10ml The Usage of this HA prp tube, both Anticoagulant ,HA and Gel in the tube: Beauty treatment: Facial rejuvenation. Skin Rejuvenation, wrinkles, eye bags, dark circles, allergic skin, large pores Orthopedics: including osteoarthritis,nerve injury, tendinitis,cardiac muscle injury, bone repair and regeneration. Scar: Facial scar or body scar, women stretchmark. operative wound healing, skin burn.
Sterile E.O Gas Filter Material Static Cotton Bacterial Filter Rate 99.99977% Virus Filter Rate 99.99926% Capacity No Tube 45mL / With Tube 78mL Resistance cmH2O@15L/min
Sterile E.O Gas Filter Material Static Cotton Bacterial Filter Rate 99.99977% Virus Filter Rate 99.99926% Capacity 35mL Resistance cmH2O@15L/min
PU or PVC material The size is high precision with excellent appearance. Pressure rated to different grade, 300PSI, 500PSI, 900PSI, 1200 PSI
Properties: Medical Polymer Materials & Products Type: Pipe,Drainage Tubes & Containers Brand Name:RIYUEXINGCHEN Model Number: F6-F18 Place of Origin: Jiangsu, China (Mainland) Name: Suction Catheter Mucus Extactor Material:Medical grade PVC,PP,AS,ABS Capacity:25ml-40ml Size:F6-F18 Package:Plastic bag,blister pouch Trade ability:MOH docs,legalization/CIQ/SAI/VOC/FTA etc. MOQ:20000pcs Certificates:93/42/EEC(CE0123),ISO13485 Sterile: EO gas sterile Supply Ability: 3000cs
This tubes have silica particles added to trigger the coagulation within an acceptable time Material: PET & PP Type of Additive: Clot Activator Size: 13X75 mm, 13X100mm Capacity: 1 mL, 2mL, 3mL, 4mL and 6mL Available in: Vacuum and Non Vacuum Colour Code: Red Available Packaging: Inner Packaging 100 pieces, Outer Carton Packaging 1200 pieces Used for: Chemistry enzymes, electrolyte Immunology presence of antibodies to a pathogen Serology protein made by human immune system Blood bank cross matching of blood types.
Material: PET & PP Type of Additives: Potassium Oxalate & Sodium fluoride Size: 13X75 mm, 13X100mm Capacity: 2mL,3mL Available in: Vacuum and Non-Vacuum Colour Code: Grey Available Packaging: Inner Packaging 100 pieces, Outer Carton Packaging 1200 pieces Used for: Specially used for sugar tests FBS, PPBS, RBS.