1. Principle This test kit is based on the competitive enzyme immunoassay for the detection of Gentamicin in the sample. The coupling antigen is pre-coated on the micro-well stripes. The Gentamicin in the sample and pre-coated coupling antigen on the micro-well stripes compete for the anti-Gentamicin antibody. After the addition of the enzyme conjugate, the TMB substrate is added for coloration. The optical density (OD) value of the sample has a negative correlation with the Gentamicin in it. The value is compared to the standard curve and the Gentamicin concentration is subsequently obtained. 2. Technical specifications Sensitivity: 0.05 ppb Incubator temperature: 25 Incubator time: 30minï½?15min
1 Principle This test kit is based on the competitive enzyme immunoassay for the detection of Fluoroquinolones in the pork, chicken, fish and shrimp, etc. The Fluoroquinolones in the sample and the coupling antigens pre-coated on the micro-well stripes compete for the anti-Fluoroquinolones antibodies. After the addition of the enzyme conjugate, the TMB substrate is added for coloration.The optical density (OD) value of the sample has a negative correlation with the Fluoroquinolones in the sample. This value is compared to the standard curve and the Fluoroquinolones concentration is subsequently obtained. 2 Technical specifications Sensitivity: 0.1 ppb Incubation Temperature: 25 Incubation Time: 30min15min
1. Principle This test kit is based on the competitive enzyme immunoassay for the detection of Florfenicol in samples. The coupling antigens are pre-coated on the micro-well stripes. The Florfenicol in the sample and the conjugate antigens pre-coated on the micro-well stripes compete for the anti-Florfenicol antibodies. After the addition of the enzyme conjugate, the TMB substrate is added for coloration. The optical density (OD) value has a negative correlation with the Florfenicol concentration in the sample. This value is compared to the standard curve and the Florfenicol concentration is subsequently obtained. 2. Technical specifications Sensitivity: 0.1 ppb Incubator temperature: 25 Incubator time: 30minï½?15min
1. Principle This test kit is based on the competitive enzyme immunoassay for the detection of Tylosin in the sample. The coupling antigens are pre-coated on the micro-well stripes. The Tylosin in the sample and the coupling antigens pre-coated on the micro-well stripes compete for the anti-Tylosin antibody. After the addition of the enzyme conjugate, the TMB substrate is added for coloration. The optical density (OD) value of the sample has a negative correlation with the Tylosin in it. This value is compared to the standard curve and the Tylosin concentration is subsequently obtained. 2. Technical specifications Sensitivity: 0.5 ppb Incubator temperature: 25 Incubator time: 75 min
ROC-F-OR003K Melamine ELISA Test Kit 1. Principle This test kit is based on the competitive enzyme immunoassay for the detection of Melamine in the sample. The coupling antigen is pre-coated on the micro-well stripes. The Melamine in the sample and the coupling antigens pre-coated on the micro-well stripes compete for anti-Melamine antibodies. After the addition of the enzyme conjugate, the TMB substrate is added for coloration. The optical density (OD) value of the testing sample has a negative correlation with the Melamine concentration in the sample. This value is compared to the standard curve and the Melamine concentration is subsequently obtained. 2. Technical specifications Sensitivity: 0.5 ppb Incubator temperature: 25 Incubator time: 30minï½?15min Detection limit: Milk powder 10 ppb Milk 1 ppb Feed 50 ppb Cross-reaction rate: Melamine 100% Cyanuric acid 60% Triazine
Gentamicin is a broad spectrum antibiotic which is widely used as bacteriostatic agents in animal husbandry and veterinary practice. It may cause side effects on gastrointestinal tract, kidney, liver, hematological system. What is worse, it may cause allergic shock. Therefore, it is possible that tetracycline residues, after use in illegal practice, may lead to a risk for consumers.
The kit uses a double-antibody sandwich enzyme-linked immunosorbent assay (ELISA) to assay the level of Human Androgen in samples. Add Androgen to monoclonal antibody Enzyme well which is pre-coated with Human Androgenmonoclonal antibody, incubation; then, add Androgenantibodies labeled with biotin, and combined with Streptavidin-HRP to form immune complex; then carry out incubation and washing again to remove the uncombined enzyme. Then add Chromogen Solution A, B, the color of the liquid changes into the blue, And at the effect of acid, the color finally becomes yellow. The chroma of color and the concentration of the Human Substance Androgen of sample were positively correlated. Standard; 128nmol/L.
The kit uses a double-antibody sandwich enzyme-linked immunosorbent assay (ELISA) to assay the level of Rat Dehydroepiandrosterone sulfate(DHEAS) in samples. Add Dehydroepiandrosterone sulfate(DHEAS) to monoclonal antibody Enzyme well which is pre-coated with Rat Dehydroepiandrosterone sulfate(DHEAS)monoclonal antibody, incubation; then, add Dehydroepiandrosterone sulfate(DHEAS)antibodies labeled with biotin, and combined with Streptavidin-HRP to form immune complex; then carry out incubation and washing again to remove the uncombined enzyme. Then add Chromogen Solution A, B, the color of the liquid changes into the blue, And at the effect of acid, the color finally becomes yellow. The chroma of color and the concentration of the Rat Dehydroepiandrosterone sulfate(DHEAS) of sample were positively correlated. Standard; 240pg/ml.
TEST KIT, INFLUENZA A&B SOFIA (25/KT 12KT/CS) UOM: 25/CS Product Number: 20218 Manufacturer: Quidel
Kit Includes: Povidone Iodine Prep, Tegaderm Dressing, Frame Style, (2) 1"x2" Gauze Sponges, ¾" Roll Transpore Tape, Tourniquet, (2) Alcohol Wipes, 25/bx, 8 bx/cs (24 cs/plt) UOM: 200/CS Product Number: 386150 Manufacturer: BD
IV Kit Includes Tegaderm 2.375 2 3/4 2 2 4-Ply NW Gauze Chloraprep Sepp, Transport Tape Roll 24 Tourniquet Change Label, 100kit/cs UOM: 100/CS Product Number: 69244 Manufacturer: Medical Action Industries
Cannula, Nasal Optiflow Jr-2 Vent Transition Kit Xlg (5/pk) UOM: 5/BX Product Number: OJR418VT Manufacturer: Fisher Paykel
Cannula, Nasal Optiflow Jr-2 Vent Transition Kit Lg (5/pk) UOM: 5/BX Product Number: OJR416VT Manufacturer: Fisher Paykel
Cannula, Nasal Optiflow Jr-2 Vent Transition Kit Med (5/pk) UOM: 5/BX Product Number: OJR414VT Manufacturer: Fisher Paykel
Cannula, Nasal Optiflow Jr-2 Vent Transition Kit Sm (5/pk) UOM: 5/BX Product Number: OJR412VT Manufacturer: Fisher Paykel
Cannula, Nasal Optiflow Jr-2 Vent Transition Kit XS (5/pk) UOM: 5/BX Product Number: OJR410VT Manufacturer: Fisher Paykel
Control Kit Cobas Liat Influenza A + B / Respiratory Syncytial Virus (RSV) Positive Level / Negative Level 3 Sets UOM: 1/EA Product Number: 07402686190 Manufacturer: Roche
Our Precision DX Superior Drug Test Cups stand alone with USA Made Strips & Reagents as the most accurate drug test cups in the market place. Use our Precision cups for your drug test needs whether its workplace, clinical, or probation, and have peace of mind because your results are 99% accurate. Tests for THC/COC/AMP/OPI/mAMP/PCP/BAR/BZO/MTD/MDMA/OXY/BUP+PH/SG/CREA Pallet Size: 48x40x72 Pallet Weight: 504lbs Shelf Life is 24 Months from date of manufacture Up to 99% Accuracy, USA Made Strips and Reagents Instant Results, Read Negatives within 1 minute & Positives in 5 minutes Includes Celsius/Fahrenheit temp strip Lock lid, no leakage Design is sturdy, durable, and plastic to maintain sample volumes for lab receiving Choose from 40 different drugs These are screening devices only and although very accurate if you get a non negative result and have questions we recommend you send to our certified lab for LC-MS/MS Confirmation.
Abbott BinaxNOW Covid 19 rapid antigen SELF test cards. Results in fifteen minutes. Available for use in the USA only. (Abbott PANBIO covid 19 rapid self test cards are available for outside the US). May be used with Abbott's NAVICA, a smartphone app which allows you to display test results to organization where people gather. 40 tests per kit. 160 kits per pallet. Special one-time test order of 10 kits, (400 tests) at $10.50 USD
A convenient digital stick thermometer kit for clinic or physician office. The Adtemp 413BRKIT kit features: (2) Adtemp 413 thermometers One Oral (Blue), One Rectal (Red) Compact size - under 5 long, weighs just 11 grams Range 90 F-109.9 F +.2 F or 32 C - 43.2 C +.1 C depending upon scale selection Reads in as little as 30 seconds (typical response time 30-40 seconds) Replaceable 1.55v (LR41) type battery provides up to 1,500 measurements Scabbard carry case keeps instrument sanitary Meets the accuracy requirements for intermittent thermometers under ASTM E1112 (100) Adtemp Disposable Thermometer Sheaths Non-sterile, disposable design helps eliminate cross contamination Cost effective and easy-to-apply Suitable for oral or rectal use Designed for use with ADC and most comparably sized digital thermometers (1) Adtempâ?¢ Countertop Dispenser Tray Molded plastic tray with rubberized feet conveniently holds both thermometers and sheaths ready for use