EAC 44 Engine: CUMMNS Engine Model : 4BT3.9-G1 Stand By kVA: 44 Stand By kW : 35,2 Prime kVA: 40 Prime kW : 32 Rated Current : 57,6 Engine - CUMMNS heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed Alternat - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine CUMMNS Engine Model 4BT3.9-G1 Number of Cylinders 4 Inline Injection System Direct Compression Ratio 17.3: 1 Bore 102 Strok 120 Displacement L 3,9 Air Intake Turbocharged Speed (RPM) 1500 Oil Capacity L 3,9 Standby Power kw / Hp 40 /54 Prime Power Hp 36 /48 Fuel Type Euro Diesel Governor System Mechanical Cooling System Water Cooling Coolant Capacity L 8,3 Fuel Consumption (lt / h) L Full Load 10 L %75 LOAD 7,9 L %50 LOAD 5,9 Frequency Hz Power kVA 44 Voltage V 230 / 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation 1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 DIMENSIONS Weight (Silent) Kg 1050 Weight (Open) Kg 865 Width (Silent) Mm 1000 Length (Silent) Mm 2400 Height (Silent) Mm 1500 Fuel Tank Capacity L 180 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnt permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAC 30 Engine: CUMM NS Engine Model : 4B3.9-G1 Stand By kVA: 30 Stand By kW : 24 Prime kVA: 27,2 Prime kW : 21,8 Rated Current : 39,2 Engine - CUMM NS heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed Alternat - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis â?? ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine CUMM NS Engine Model 4B3.9-G1 Number of Cylinders 4 Inline Injection System Direct Compression Ratio 17.3: 1 Bore 102 Strok 120 Displacement L 3,9 Air Intake Natural Aspiration Speed (RPM) 1500 Oil Capacity L 3,9 Standby Power kw / Hp 27 / 36 Prime Power Hp 24 / 32 Fuel Type Euro Diesel Governor System Mechanical Cooling System Water Cooling Coolant Capacity L 8,3 Fuel Consumption (lt / h) L Full Load 7,1 L %75 LOAD 5,7 L %50 LOAD 4,3 Frequency Hz Power kVA 30 Voltage V 230 / 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation 1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 DIMENSIONS Weight (Silent) Kg 880 Weight (Open) Kg 725 Width (Silent) Mm 900 Length (Silent) Mm 2200 Height (Silent) Mm 1350 Fuel Tank Capacity L 135 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAR 200 Engine: RICARDO Engine Model : R6110-IZLD Stand By kVA: 200 Stand By kW : 160 Prime kVA: 181 Prime kW : 145 Rated Current : 260 Engine - RICARDO heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed Alternator - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis â?? ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine RICARDO Engine Model R6110-IZLD Number of Cylinders 6- Sral Injection System Direkt Compression Ratio 16:01 Bore 110 Strok 135 Displacement Lt 7,01 Air Intake Turbo�?arj Intercooled Speed (RPM) 1500 Oil Capacity Lt 18 Standby Power kw / Hp 173 / 231,8 Prime Power Hp 157 / 210,4 Fuel Type Euro Dizel Governor System Mechanical Cooling System Water Cooled Coolant Capacity Lt 25 Fuel Consumption (lt / h) Lt Full Load 39,5 Lt %75 LOAD 29,6 Lt %50 LOAD 19,8 Frequency Hz 50 Power kVA 200 Voltage v 230 / 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation �±1% Insulation Class H Protection Standard IP21 - IP23 Power Factor 0,8 Weight (Silent) Kg 1730 Weight (Open) Kg 1480 Width (Silent) Mm 1000 Length (Silent) Mm 3150 Height (Silent) Mm 1700 Fuel Tank Capacity Lt 220 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAR 175 Engine: RICARDO Engine Model : R6105-IZLD Stand By kVA: 175 Stand By kW : 140 Prime kVA: 160 Prime kW : 128 Rated Current : 230,4 Engine - RICARDO heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed Alternatr - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis â?? ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine RICARDO Engine Model R6105-IZLD Number of Cylinders 6 Inline Injection System Direct Compression Ratio 16:01 Bore 105 Strok 135 Displacement L 7,01 Air Intake TURBO INTER - COOLED Speed (RPM) 1500 Oil Capacity L 15 Standby Power kw / Hp 145,2 /194,6 Prime Power kw / Hp 132 / 176,9 Fuel Type Euro Diesel Governor System Mechanical Cooling System Water Cooling Coolant Capacity L 25 Fuel Consumption (lt / h) L Full Load 33,5 L %75 LOAD 25,2 L %50 LOAD 17 Frequency Hz Power kVA 175 Voltage V 230 / 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation ±1% Insulation Class H Protection Standard IP21 - IP23 Power Factor 0,8 Weight (Silent) Kg 1660 Weight (Open) Kg 1410 Width (Silent) Mm 1000 Length (Silent) Mm 3150 Height (Silent) Mm 1700 Fuel Tank Capacity L 250 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnot permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAR 125 Engine: RICARDO Engine Model : R6105-ZLD Stand By kVA: 125 Stand By kW : 100 Prime kVA: 113 Prime kW : 90 Rated Current : 162,72 Engine - RICARDO heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed Alternat�¶r - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis â?? ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine RICARDO Engine Model R6105-ZLD Number of Cylinders 6 Inline Injection System Direct Compression Ratio 16:01 Bore 105 Strok 130 Displacement L 6,49 Air Intake Turbocharged Speed (RPM) 1500 Oil Capacity L 13 Standby Power kw / Hp 110 / 147,45 Prime Power kw / Hp 100 / 134 Fuel Type Euro Diesel Governor System Mechanical Cooling System Water Cooling Coolant Capacity L 23 Fuel Consumption (lt / h) L Full Load 25,6 L %75 LOAD 19,2 L %50 LOAD 12,8 Frequency Hz Power kVA 125 Voltage V 230 / 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation ±1% Insulation Class H Protection Standard IP21 - IP23 Power Factor 0,8 Weight (Silent) Kg 1540 Weight (Open) Kg 1290 Width (Silent) Mm 1000 Length (Silent) Mm 3150 Height (Silent) Mm 1700 Fuel Tank Capacity L 250 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAR 110 Engine: RICARDO Engine Model : R6105-ZD Stand By kVA: 110 Stand By kW : 88 Prime kVA: 100 Prime kW : 80 Rated Current : 144 Engine - RICARDO heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed Alternator - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis â?? ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine RICARDO Engine Model R6105-ZD Number of Cylinders 6 Inline Injection System Direct Compression Ratio 16:01 Bore 105 Strok 130 Displacement L 6,49 Air Intake TURBO Speed (RPM) 1500 Oil Capacity 16 Standby Power kw / Hp 115,5 / 154,8 Prime Power kw / Hp 105 / 140,7 Fuel Type Euro Diesel Governor System Mechanical Cooling System Water Cooling Coolant Capacity L 23 Fuel Consumption (lt / h) L Full Load 22,2 L %75 LOAD 16,7 L %50 LOAD 11,1 Frequency Hz Power kVA 110 Voltage V 230 / 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation ±1% Insulation Class H Protection Standard IP21 - IP23 Power Factor 0,8 Weight (Silent) Kg 1480 Weight (Open) Kg 1230 Width (Silent) Mm 1000 Length (Silent) Mm 3150 Height (Silent) Mm 1700 Fuel Tank Capacity L 250
EAR 60 Engine: RCARDO Engine Model : D4105-ZD Stand By kVA: 60 Stand By kW : 48 Prime kVA: 54,5 Prime kW : 43,6 Rated Current : 78,5 Engine - RCARDO heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed Alternatr - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis â?? ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system ENGINE Engine R�°CARDO Engine Model D4105-ZD Number of Cylinders 4 Inline Injection System Direct Compression Ratio 17:01 Bore 105 Strok 115 Displacement L 3,61 Air Intake TURBO Speed (RPM) 1500 Oil Capacity L 13 Standby Power kw / Hp 60,5 / 81 Prime Power kw / Hp 56 /75 Fuel Type Euro Diesel Governor System Mechanical Cooling System Water Cooling Coolant Capacity L 18 Fuel Consumption (lt / h) L Full Load 14,5 L %75 LOAD 11 L %50 LOAD 7,6 Frequency Hz Power kVA 66 Voltage V 230 / 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation ±1% Insulation Class H Protection Standard IP21 - IP23 Power Factor 0,8 Weight (Silent) Kg 1100 Weight (Open) Kg 900 Width (Silent) Mm 1000 Length (Silent) Mm 2400 Height (Silent) Mm 1500 Fuel Tank Capacity L 180 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
Food products, fruit and recreational plants, palm trees, generators, transformers, household electronics, ev charging stations, accumulators and battery systems, cooling appliances and frigotic systems for vehicles, furnitures (office and household types), copper tubes, powder metals for 3d printers, electrical equipment, defense products most notably drones (strategic /tactical), carrying boxes..Trade, sourcing and investment intelligence, supply chain development services, trade facilitation, inspection, operations support, full fledged trade/supply chain agency services
En590 diesel 10ppm, d6, jet a1 fuel, a1 fuel, urea 46%.Export
Silica sands, frozen vegetable and fruits, generators.
Shellbau sip panels, fuel (diesel, jet fuel, wood (logs) and fertilizer (urea 46) .Transportation and shipping
D2 gas oil , diesel en590 10 ppm , light circle oil (lco) , mazut m100 , jet fuel jp54 / jet a1 , liquified petroleum gas (lpg) 60/40, 50/50 and 80/20 , d6 fuel oil, heavy fuel oil (hfo), pet coke, brazilian sugar icumsa 45.Trader
Maximum Engine Power (Stand-By) 25 kVA Maximum Engine Power (Prime) 22 kVA Voltage 230/400 V Light Power 4x1000 W Total Light Power 4000 W Brightness Level 30400 (5 Lumen/m2) Auxiliary Car Plugs 2 x 220 V - 380 V Tower Rise Capacity 9000 mm. Rotation Capacity 360 Angle Tower Movement System Hydrolic Slope Angle
Diesel Additive
Pomsan offers you various and optional tools for different diesel systems. You will be able to use these apparatus for systems like: - Unit Injection Systems - Common Rail Injection Systems - Hydraullic Injection Systems - Electronic Diesel Systems - Mecahnical Pumps and many more.
Diesel.
Structure Size : 90 - 355 Rated Power : 0.37 / 1.66 30/37 kW Pole Number : 16 / 4-12 / 4-16 / 6-8 / 4-6 / 4-12 / 6-16 / 2-4 / 2 Protection Class : IP55 (up to 280 types), IP65 (315 types and above) (Contact us for higher protection classes.) Voltage : 380 V (Contact us for different voltages.) Frequency : 50 Hz (Contact us for different frequencies and speed control devices.) Build Type : B3 (Contact us for different structure types.) Mechanical Structure : Body and covers are cast iron, legs are ductile iron Cooling Type : IC 411 (Contact us for different cooling types and for forced cooling.) Insulation Class : F / H (Contact us for different insulation classes.) Working Regime : S1 (Contact us for S2..S10 operating regimes.) Ambient temperature : 40 C (Contact us for higher ambient temperatures.) Motor Protection : Thermistor and motor protection relay for over 250 types (Applicable to smaller types.)
Structure Size : 58-63-74-81-93 / MR65-MR71-MR-80/112 Rated Power : 1.1-7.5 kW Pole Number : 2 - 4 Protection Class : IP55 Voltage : 380 V Frequency : 50 Hz Build Type : B3 Mechanical Structure : Aluminum or Iron Body Cooling Type : IC 411 Insulation Class : F Working Regime : S1, S6- 40% Ambient temperature : 40 C Motor Protection -
Diesel.