SS-49:S3 UPPER : Micro â??Fiber Leather LINING : Leather Lining TOE CAP : Steel Toe Cap PENETRATION RESISTANCE : Stainless Steel Midsole FOOTBED : Moulded Stock- Insole SOLE : Direct Injection Double Density 2 Layer Sole A) Low Density Polyurethane Midsole B) High Density Polyurethane Outsole SIZE : 38-49
SS-45:S1P UPPER : Split Barton Print 1.8-2.0mm LINING : Mesh Lining TOE CAP : Steel Toe Cap PENETRATION RESISTANCE : Stainless Steel Midsole FOOTBED : Moulded Stock- Insole SOLE : Direct Injection Double Density 2 Layer Sole A) Low Density Polyurethane Midsole B) High Density Polyurethane Outsole SIZE : 38-47
SS-25:S1P UPPER : Split Barton Print 1.4-1.6mm LINING : Spacer Lining TOE CAP : Steel Toe Cap PENETRATION RESISTANCE : Stainless Steel Midsole FOOTBED : Moulded Stock- Insole SOLE : Direct Injection Double Density 2 Layer Sole A) Low Density Polyurethane Midsole B) High Density Polyurethane Outsole SIZE : 39-46
SS-16:S3 UPPER : Buff Smooth CG S2 Leather LINING : Cambrelle Lining TOE CAP : Composite Toe Cap PENETRATION RESISTANCE : Kevlar Sheet FOOTBED : Moulded Stock- Insole SOLE : Direct Injection Double Density 2 Layer Sole A) Low Density Polyurethane Midsole B) High Density Polyurethane Outsole SIZE : 39-46
SS-26:S1P UPPER : Split Barton Print 1.4-1.6mm LINING : Spacer Lining TOE CAP : Steel Toe Cap PENETRATION RESISTANCE : Stainless Steel Midsole FOOTBED : Moulded Stock- Insole SOLE : Direct Injection Double Density 2 Layer Sole A) Low Density Polyurethane Midsole B) High Density Polyurethane Outsole SIZE : 39-46
SS-13:S1P UPPER : Split Barton Print 1.8-2.0mm LINING : Mesh Lining TOE CAP : Steel Toe Cap PENETRATION RESISTANCE : Stainless Steel Midsole FOOTBED : Moulded Stock- Insole SOLE : Direct Injection Double Density 2 Layer Sole A) Low Density Polyurethane Midsole B) High Density Polyurethane Outsole SIZE : 38-47
SS-101:S1P UPPER :Microfiber Leather With Mesh Fabric LINING : Mesh Lining at Vamp & Quarter s TOE CAP : Campsite Toecap PENETRATION RESISTANCE : Kevlar Midsole SOLE : Direct Injection Double Density 2 Layer Sole A) Low Density Polyurethane Midsole B) High Density Polyurethane Outsole SIZE : 35-42
UPPER: Full Grain Cow Leather Water Resistance Thickness 2.0 â?? 2.20 MM LINNING: High Abration Mesh Lining with padded Foam with Codura Outer Lining SIDE ZIP: YKK Original FOOTBED: Sweat absorbtion Cushioned Insole for Comfort SOLE: Direct Injection 2 Layer Sole with Rubber/PU MIDSOLE: Low Density Polyurethane for shock absorbtion & under foot comfort OUTSOLE: Rubber outsole designed for maximum grip and oil & heat resistance
Limestone Supplier We are a professional organization that specializes in mining high and low purity limestone for your needs with the upmost quality and efficiency with best Price. We are currently sitting on 25 million tons reserve of limestone in our Quarry and have a fully functional state of the art operation that can produce more than 80,000 tons of limestone monthly. Our Product use for : Cement Factories , Steel Industry , Chemical Industries , Ball Mill Divisions , Quick and Hydrated Lime Industries , Ceramics Tile Industries , Artificial Stone Industries , Agriculture
Limestone has a diversified use in today's Industrial world. As a raw material it is used in the following industries and construction projects Glass Industry: Limestone is used in the purification of molten glass. Most glass is made by fusing a mixture of silica sand and soda ash, limestone dolomite and other material. Generally very high purity (CaCO3 98.5 % or CaO 55.2) is required for this application. Iron Industry: Limestone is used to remove impurities from molten iron. Limestone or lime is used as a flux to assist melting. The lime reacts with silica and alumina impurities in the ore and forms a slag which floats on the surface of the Melt Steel Industry: Limestone is also used as a flux in the steel industry and is required to remove silica and phosphorus from pig iron. The limestone required should be of high purity with low silica (5 to 2%) and sulphur of less than 0.1%.
TI UNITS Reciprocating Water Chillers are available in two types of air cooled and water cooled in capacity range of 5 to 240 tons of refrigeration and compressor configurations of one to four. Evaporators and condensers are high efficiency shell and tube heat exchangers designed based on TEMA (Tubular Exchanger Manufacturers Association) standards. Safety controls installed on all units include high and low pressure cut-outs, compressor oil pressure safety cut-out, water anti freeze thermostat, water flow switch and evaporator entering water thermostat. Whatever mentioned above, are all chosen from the most recognized controls manufacturers in the air conditioning industry. Compressors are by DWM COPELAND and BITZER which happens to be one of the best and the most reliable brands. Raw materials such as copper tubes, fittings and valves are supplied by well respected manufactures. Electrical safety measures such as three phase controller and circuit breakers are available on all units. A fault detection system for the whole unit is available upon request. Microprocessor based PLC controller is also available as needed.
Each union is thoroughly inspected to ensure long, dependable service in the most extreme conditions. Available in stock at our distribution center in houston. Three lug nuts and self-locking acme threads provide quick make-up and break-out Color coded for quick identification Unique identification for sour gas unions Meet or exceed national association of corrosion engineers standard nace mr-01-75 and api rp-14e Manufactured from quality steel meeting astm and/or aisi standards All unions provide pressure-tight & positive sealing for low-pressure services (500 to 2, 000 psi) The spherical surface male sub and angular surface female sub form a metal-to-metal seal, the ball and tangent provides a perfect seal Range from 1/2 to 12 with cold working pressures from 500 to 20, 000 psi Fully interchangeable with most major brands of hammer unions
TI UNIT compact roof top chiller units are manufactured in type of air cooled in capacities of 5 to 360T.R. in one to four circuited configurations. In all TI UNIT compact roof-top chiller units the frames and body are from galvanized steel & stainless steel (316l) (option) the chassis made steel channel in appropriate thicknesses and all of units are completely painted in the proper thickness. Evaporators are high efficiency shell and tube heat exchangers, designed based on TEMA. Condenser of compact rooftop chiller unit made of plated coil, designed based on TEMA. Chillers with plate type heat exchangers are available upon request. TI UNIT compact roof top chillers can be designed to operate with R-22, R-407C and R-134a refrigerants. Safety controls installed on all units include high, oil and low pressure cut-outs, compressor safety cut-out, water anti freeze thermostat, water flow switch and evaporator entering water thermostat and compressor operation time logger. The above mentioned are all chosen from the most recognized controls manufactures in the air conditioning industry. Automatic condensing temperature control: A controller, factory installed on each unit automatically stages the condenser fans allowing the unit to start. With this controller the condenser fans start stage by stage. Raw materials such as copper tubes, fittings and valves are supplied by well-respected manufacturers. Electrical safety measures such as three phase controller and circuit breakers are, available on all units. A fault detection system for the whole unit is available upon request. Microprocessor based PLC controller is also available as needed. Suitable accessories make the chillers operable in all seasons according to the application requirements without any problems.
TI UNIT screw chillers are manufactured in two types of air cooled and water cooled in capacities from 50 to 560 T.R. in one to four circuited configurations. Evaporators and condenser Chillers with plate type heat exchangers are available upon request. For further related technical information, please send your inquiries to TI UNIT mfg. group. TI UNIT screw chillers can be designed to operate with R-22 and R-134a refrigerants. Bitzer screw compressors suitable for use with R-134a refrigerant are available in two versions (m.vr.1 & m.vr.2) which can be used in the chillers as required. Safety controls installed on all units include high and low pressure cut-outs, compressor oil level control safety cut-out, water anti freeze thermostat, water flow switch and evaporator entering water thermostat and compressor operation time logger. The above mentioned are all chosen from the most recognized controls manufactures in the air conditioning industry. Compressors are by Bitzer which happens to be one of the best and most reliable brands. Raw materials such as copper tubes, fittings and valves are supplied by well-respected manufactures. Electrical safety measures such as three phase controller and circuit breakers, are available on all units. A fault detection system for the whole unit is available upon request. Microprocessor based PLC controller is also available as needed. TI UNIT screw chillers are also available upon request for industrial applications in both Air Cooled and Water Cooled types; Suitable accessories make the chillers operable in all seasons according to the application requirements without any problems.
With multi-direction air flow supply, automatic swing wind, users can set auxiliary wind gap to send part of air to other place, so as to improve the indoor temperature and the air flow uniformity. System adopts big diameter vortex centrifugal fan to make running silently, and optional anion generator to make pure and fresh indoor air. Ultrathin frame, min-thickness for frame is only 260mm, users can chose installation direction for connection pipe depending on spot situation, the overall dimension for part of unit is only 590x590mm easy installation with low installation cost. Remote control is available, flexible control method. High lift water pump design (750mm); Disposal of condenser water pipes is easy and flexible. Water level switch protection ensures no water leakage, water in the discharge pan can be discharged manually; and the water holder pan is designed with discharge hole, which can discharge the remaining condenser water on time, so as to reduce the possibility for bacteria growth, meanwhile discharging dirt in the regular time reduces clogging probability for water pump. â??Câ?? type heat exchanger can aid terminal air flow and the uniformity for cooling system, the effect for 4-way air-out can be more balanced, and system leak out possibility can be lower. Hydrophile aluminum coil fin can greatly reduce condensation water remaining on the fin, therefore it reduces the windage and the effect for heat exchange is also improved. Available for BMS concentrate intelligent control system. And some more designs for easy installation including built-in water valve (optional) for easy exterior connection installation, hand protection grilling and stainless steel soft pipe connection.
In all TI UNIT air handling units the frames are from aluminum profiles while the chassis and body panels are made from galvanized steel sheets in appropriate thicknesses. All units are completely painted in the proper thickness. Blower(S): Double width-double inlet centrifugal fans with forward curved blades are normally used for low pressure drop requirements as opposed to fans with backward curved blades which are for high pressure drop applications. Fans and housings are made of galvanized steel each set off a plus other related components such as shafts are statically and dynamically balanced, shafts are selected from proper material and size. Other power transmission components such as pulleys and belts are also suit ably chosen depending on the required fan speed and electric motor power. Fan(s) and the corresponding electric motor(s) are installed on an independent chassis which is itself installed on the main chassis using vibration dampers in order to eliminate transfer of vibrations to the structure. To further reduce the effects of vibrations, fan outlet (s) are also connected to the structure via flexible material such as canvous. All 380V/3/50Hz electric motors are selected with insulation class of (f) and ingress protection of (IP- 54). Electric motors with ingress protection of (IP- 55) are also available upon request. Coil (S): Cooling and heating coils or either one of the two depending on the Requirement May be installed. Cooling coils are available in two, types of chilled water and direct expansion (D.X.) as per clients requirements. The chilled water coils are constructed of 5/8 O.D copper tubes plate finned (8, 10, 12 or 14 FPI) in aluminum or copper upon request. The D.X. Coils are constructed of 3/8 OD copper tubes also plate finned (10, 12 or 14 FPI) in aluminum or copper as required. The chilled water for cooling coils in to be supplied by a water chiller and in the D.X. coils cooling is provided through the use of refrigerant such as R-22, R-407c or R-134a. Chilled water coils may be requested in 4 or 6 rows and as to the D.X. coils, they are available in 4 or 6 row configurations. Heating coils are available in two types of hot water and steam. The hot water coil similar to chilled water coil is offered in 1 or 2 row configurations. Steam heating coils are constructed of 1/2 seamless steel pipe spiral finned in aluminum or copper. Coils in 1 & 2 -row configurations are available upon request. Mixing box: Fresh and return air streams are mixed in the mixing box .An independent air damper is included for each air stream. Air Dampers are manufactured from aluminum in opposed blade configuration and are air sealed through the use of rubber strip gasket. Damper actuators ma y be easily installed when required. Washable aluminum filter modules 2 inches in thickness are arranged in (V) type configuration inside these boxes. Housing for
Chairs And Tables..
Low Fat Dry Milk, Full Fat Dry Milk.
Types: 1- Fresh 2- Al Kalized Powder Cocoa High and low fat 3- Natural Powder Cocoa High and low fat
Home ,office and working site furniture.