Jute Products, Fly Ash And Charcoal.
Automobile, auto parts, canadian lumber.
Dried hibiscus flower, sesame seed, ginger, gum arabic, cashew nut, palm oil, charcoal, woods.
Mogul's Universal Sorbents are your versatile solution for quick and efficient clean-ups. Low-linting, bonded, and perforated, these highly absorbent pads and rolls tackle oil, water, coolants, and more. Ideal for machinery, leaky pipes, traffic areas, or general maintenance, they come in various options, from cost-effective basics to durable, low-linting products for high wear resistance. Grey absorbents handle water-based, petroleum-based, and non-aggressive chemical fluids, while perforations offer cost control. Pads are sold in Bales of 50 / 100 / 200 We have all types and weights of Wholesale Sorbent Pads Sorbent Categories - Oil Only, Universal, Hazmat Sorbent Weights - Light, Medium, Heavy (sold by weight in gsm, pounds or kg) Sorbent Fabric Types - Fine Fiber, SMS, MMM, 100% Pure Meltblown Sorbent Colors - White, Blue, Grey, Green, Yellow Average of 1600 x 100 count Bales of 100 pads per 40'HC Average of 750 x 150' foot Rolls per 40'HC
Metal, Wood, Fertilizer, Rice, Paper..
Hand Crank Winch Used to pull various pieces of equipment in the main line sewer, such as sleeve installers, carriers, lateral launcher, deflection gauges, kit of inflatable plugs for segmental testing, etc. Easy to move by flipping the winch on its wheel and using the legs as handles. Setup allows two different speeds. The winch is provided with 500 feet of 3/16" galvanized steel cable. Easily dismantled for convenient storage
Disinfections wipes, brand name clothing hurley, under armor, disney, eddie bauer, american standard toilets, kitchen and bathtub faucets, toilets, bathtubs, eddie bauer lady's boot shoes and clothing : shorts, slippers, baby t shirt brands men's shirt indoor and outdoor air conditioning ac units, cooling/heating units, hvac , 50 samsung air conditioner indoor/outdoor, bathtubs and plumbing supplies.
Artesian water, alkaline water, water, yellow corn, soybean milk, egg whites, limestone, wheat bran, tinctures, flower strains.
Manhole Pulleys Manhole top roller: Made from steel and aluminium. 48 long, for a solid and steady hold on the sides of the manhole. Longer configurations available upon request. Manhole pulley - bottom section: All-steel build, held from the top of the manhole. Bottom manhole pulley: Robust model, all-steel build. Adjustable for installation in the opening of the pipe during use.
Deflection Gauges for Pipe Testing Logiball Deflection Gauges use a nine-arm design to make sure the pipe is accurately tested. Made entirely from steel, their lengths are at least the nominal diameter of the pipe. Stainless steel build also available. Available for 5% or 7.5% deflection for 6â?³ to 21â?³ pipe. Built for the standards required by the customer (BNQ, ASTM or other).
Easy to use. One tablet for 227 liters of water (60 US gallons) Dissolves in 5-8 minutes Available in yellow/green, red or blue. These bright dye tablets are used to: Detect leaks in sewage systems Trace water and industrial effluents Trace cross connection systems Measure power plant discharge Detect toilet tank leaks Detect illegal sewer connections Monitor flow studies and mapping Analyse septic systems Features Available in fluorescent yellow/green, red or blue : Florescent yellow/green : Most popular color Greater apparent contrast in murky brown water May be used for visual, ultraviolet and fluorometric inspections Photo degradation takes plase in sunlight within 2-3 days Blue : Storm & sewer drain Offers excellent contrast in clay pipes when using color cameras May be used for visual inspections Generally blue may be more acceptable to public view Photo degradation starts to take place in 2 to 3 weeks Red : Offers greater contrast to heavy concentrations of green algae May be used for visual, ultraviolet* and fluorometric inspections Has a higher light fastness than FLT Yellow/Green, taking approximately 5-7 days to fade
Segmental Sewer Air Test Kits Segmental testing is used to identify and pinpoint leaking joints in sewer collection systems. The inflatable plugs are winched in tandem down the line and positioned to straddle the joint or span to be tested. Once the plugs are inflated, a low-pressure air test is performed to verify the integrity of the joint or span and to localize sewer defects. Lateral connections and lines can also be tested when there is an above ground access for the introduction of an inflatable sewer plug from the cleanout. The mainline plugs are positioned on each side of the lateral connection and the push plug is inserted into the cleanout access isolating the lateral connection and lateral line. Flexible Push-Type Test Rigs are used to perform low pressure air tests on laterals from an above ground access. Contact us with your application and requirements.
Flexible Push-Type Test Rig for Segmental Pipe Testing Logiball Push-Type Test Rig is used for segmental air testing of lateral lines, from the cleanout or above ground access. The standard test chamber between the two inflatable bladders is 5 feet long. A 3/4 semi-rigid hose is used as a push rod and to inflate both bladders in one operation. Air for the test chamber is supplied thru a 1/2 semi-rigid hose to be used as a second push rod and lateral test line. Logiball Flexible Push-Type Test Rig can be used in lines 4 to 6 inch in diameter. For sealing defective laterals using chemical grout, use the Flexible Push/Pull Type Packers The control system for inflation & test is offered separately.
PR11 TEA, a Triethanolamine (TEA) Activator, is a catalyst to be used with PR10 ACLM acrylamide products as an activator for reaction. TDS SDS PR11 TEA Canadian French SDS PR11 TEA Canadian English SDS PR11 TEA US English SDS PR12 APSF is a catalyst to be used with PR10 ACLM acrylamide. It is a white crystalline solid and used as a polymerization initiator. Ammonium persulfate is a powder that is a required grout component. PR12 APSF decomposes over time as it is a strong oxidizing material TDS SDS PR12 APSF Canadian French SDS PR12 APSF Canadian English SDS PR12 APSF US English SDS PR13 SPSF (Sodium Persulfate) is a catalyst to be used with PR10 ACLM acrylamide. It is a white crystalline solid and used as a polymerization initiator. Sodium persulfate is a powder that is a required grout component and can be increased from 5 lbs. (1% by total mix weight of 500 lbs., 60 oz. by volume to a maximum of 15 lbs. (3% by total mix weight of 500 lbs., 180 oz. by volume). PR13 SPSF decomposes over time as it is a strong oxidizing material. TDS SDS PR13 SPSF Canadian French SDS PR13 SPSF Canadian English SDS PR13 SPSF US English SDS PR17 LYTX is a water-based additive to strengthen gel and reduce shrinkage. With acrylamide, replace up to 2 gallons mix water with PR17 LYTX in each tank. Seals leaks in sanitary and storm water mainlines, pipe penetrations, laterals, lift stations and manholes. TDS SDS PR17 LYTX Canadian French SDS PR17 LYTX Canadian English SDS PR17 LYTX US English SDS
Design allows to seal laterals connected to manholes. Injections have been done up to 30 feet. Logiball Man Entry Pipe Lateral Grouter is an inflatable bladder with threaded adapter used to install our standard lateral grouting plugs to seal laterals from a man entry pipe or a manhole. It includes one inflation port for the lateral bladder, one inflation port for the 4-6 bladder, two ports for the chemical grout and one void liquid filled pressure sensor line.
Lateral Test and Seal Packers Logiball 2001L packers are used to test and seal off infiltration in sewer laterals, from the mainline, without any access to cleanouts. The lateral grouting plug is inverted and deployed into the lateral from the mainline packer assembly. The mainline sleeve then expands to create a minimal grout mixing chamber. The grout is pumped and migrates freely along the restricted expansion of the lateral plug and out through existing pipe defects into the surrounding bedding to seals defects, leaving only a thin layer of grout in the lateral. The packers are available with different void pressure monitoring systems; a conventional localized liquid filled sensor (S), recommended for acrylamide and acrylate grouts, an in-wall water chamber sensor (W), recommended for stickier grouts such as urethanes and polyurethanes, or both systems (S+W) for a more versatile use. The 2001L Lateral Packer comes standard with two grout ports and a third port dedicated for the test medium (air or water). 2001L Lateral packers work best with a five-hose system. Lateral Grouting Plugs can be interchanged in a matter of minutes to grout distances up to 30 feet if necessary. Lateral Grouting Plugs are available for 4, 5 or 6 diameter laterals. Flexible housing extensions are needed for lateral grouting plugs 24 or longer. ICGA promotes the proper use of chemical grouting as a safe, economical and effective means to reduce ground water infiltration into sewer collection systems. The 2001L model is available for 6â?³, 8â?³, 9â?³, 10â?³, 12â?³, 15â?³, 18â?³, 21â?³, 24â?³ and 30â?³ mainlines. For larger diameter contact our sales department. For larger diameters, see our Man Entry Lateral Packers for 36â??â?? & up or contact our sales department. Features * As measured on the rubber. Specifications subject to change without notice. Logiball Lateral Packer Approximate Void Volumes. View list of parts for the lateral packers 2001L. (pdf file) A Control Panel is available to operate the lateral packer from the truck.
Reprocessing Plugs Logiball Reprocessing Plugs are field-tested and approved by relining contractors around the world. Ideal for reprocessing the CIPP liners or installing FF liners in pipe sizes ranging from 6â?? to 21â??. These plugs come with a 1/2â?? thick rubber sleeve, reinforced with multiple layers of fabric, and molded on an aluminum core. Steel or stainless-steel construction are also available upon request. FEATURES Rubber sleeves can be factory-replaced. Larger and custom-made configurations are possible. Contact us with your requirements to request a quote.
Controlling the live flows from the surface Logiball multisize high/low flow inflatable sewer plugs allow for optimal flow control during CCTV inspection, pipe reinstatement or sectional lining. By maintaining the sewer flow active, under control and at a reasonable level, work can be performed downstream without completely blocking the flow or requiring bypass pumping. The active flow is controlled from above ground, with the Logiball High Flow/Low Flow Plug. When inflating the plug, the outer bladder expands and seals the host pipe. A separate controlled air line is used to expand the internal sleeve, similar to a pneumatic pinch valve, which reduces the amount of flow going through the center of the plug. The operator can decide how much water flow is allowed to go through the plug by pressurizing or depressurizing the internal seal from the surface, never having to enter the manhole. By releasing the pressure in the internal sleeve, flow is allowed to go through the plug, reducing the back pressure applied on the plug and allowing for a safe plug removal. Features Logiball High Flow/Low Flow Plugs cannot be used for air testing. Air hoses sold separately.
Lightweight inflatable type E plugs Logiball lightweight inflatable type E plugs are your best option for submerged pipes and short sections of pipes. Each plug is factory-tested at the factory at twice the recommended inflation pressure. The light and compact structure of these multisize plugs makes it possible to safely plug small pipes from the surface, using a pipe handle. Perfect for tight, hard-to-reach places, these rubber plugs come with a strong anchoring chain and are made to be used with a standard pipe handle.
Logiball Type D inflatable sewer plug Logiball Type D inflatable sewer plugs are a great tool for by-pass pumping and/or flow diversion when performing manhole and invert rehabilitation. Our Type D pipe plugs feature a double-action bladder: When inflating the plug, the inner bladder forms a tight seal around the by-pass pipe or the pump suction hose, while the outer bladder completely seals against the pipe wall. This â??slip it in and inflate unique feature will save you both time and effort. Logiball Type D plugs are available for pipe sizes ranging from 3â up to 16 in diameter.