Place of Origin: China Brand Name: OEM Model Number: RX16 Power Source: manual Warranty: 1 Year After-sale Service: NONE Material: metal, Resin Shelf Life: 3 years Quality Certification: ce Instrument classification: Class I Safety standard: EN 149 -2001+A1-2009 Name: X-Ray protective collar, Application: X-Ray Room Equivalent:: 0.35mmpb Lead equivalent for options:: 0.25mmpb, 0.35mmpb, 0.5mmpb
DESCRIPTIOn: Titanx100 RADIOGRAPHY RATING: 25-100mA, stations 45kVp to 100 kVp in 15 steps OUTPUT: 8KW RECTIFICATION: Full Wave Rectified TIMER: 0.06 to 5 sec DIGITAL DISPLAY : Digital Display of mAs, kV & mA X-RAY TUBE: XD-3/Imported POWER SUPPLY: 230 Voltage AC, 15 Amps LINE REGULATION: 10% 0.6max PROTECTION: Electronic overload Protection TUBE STAND counter Balance Mobile
DESCRIPTION: Titanx RADIOGRAPHY RATING: 25-100mA, stations 45kVp to 100 kVp in 15 steps OUTPUT : 8KW RECTIFICATION: Full Wave Rectified TIMER: 0.06 to 5 sec DIGITAL DISPLAY: Digital Display of mAs, kV & mA X-RAY TUBE: XD-3/Imported POWER SUPPLY: 230 Voltage AC, 15 Amps LINE REGULATION: 10% 0.6max PROTECTION: Electronic overload Protection TUBE STAND: Floor to Ceiling Column Stand
DESCRIPTION: Titanx100 RADIOGRAPHY RATING: 25-100mA, stations 45kVp to 100 kVp in 15 steps OUTPUT : 8KW RECTIFICATION: Full Wave Rectified TIMER: 0.06 to 5 sec DIGITAL DISPLAY: Digital Display of mAs, kV & mA X-RAY TUBE: XD-3/Imported POWER SUPPLY: 230 Voltage AC, 15 Amps LINE REGULATION: 10% 0.6max PROTECTION: Electronic overload Protection TUBE STAND: Counter Balance Mobile
DESCRIPTION- TITANX 100 RADIOGRAPHY RATING- 25-100mA, stations 45kVp to 100 kVp in 15 steps OUTPUT 8KW RECTIFICATION- Full Wave Rectified TIMER- 0.06 to 5 sec DIGITAL DISPLAY- Digital Display of mAs, kV & mA X-RAY TUBE- XD-3/Imported POWER SUPPLY- 230 Voltage AC, 15 Amps LINE REGULATION- 10% 0.6max PROTECTION- Electronic overload Protection TUBE STAND- Spring Balance
X-ray protective Aprons - Lead Apron - Lead-Free Apron
X ray machines, Mammography machines, digital Xray, OPG machines, C Arm, dental Xray, Portable X ray.Manufacturing and export
Our Coat Aprons provide protection from the Front and 16 cm from the shoulder down. Medical Index X-ray Protection Aprons are Made in Germany. Our lead material are certified according to IEC 61331-1 and IEC 61331-3. Product Specification: Standard Lead Pb value: 0.50 mm Pb Size: MEDIUM Length 110 cm Width 60 cm KV Range: 50-150 Velcro or Snap-lock closure +45 colors available
1.Abt leaded glass: Lead glass is a silica type, of high quality optical grade with over 60 percent heavy metal oxide. Zf2 and zf3 lead glass is mainly used in x-ray room and ct scanning room. Zf6 and zf7 lead glass is mainly used in nuclear industry such as nuclear power station and atomic energy application. 2.Terms: Payment terms:t/t;western union. Shipment terms:fob qingdao, tianjin, shanghai. Delivery time:1-15days to your orders. Packing details:first packed with foams then wooden case 1.With foams 2.With wooden case
1. When adding up voltage, total current is less than 2a and total power is 500w; 2. The current and voltage of x-ray tubes are fixed in three groups, they are: X exposure voltag (kvp) 60 65 70 X-ray current (ma) 0.5 0.85 1.10 3. When adding up voltage, total current is less than 2a and total power is 500w 4. Drain current and earth resistance are in accordant with the stipulates in gb9706.1 5. The three groups of voltage (60kv, 65kv, 70kv) are adjustable. 6. Wireless remote control in any angles within 10 meters part form the control box 7. The parameter of x-ray generator (bulb tube head) the parameter of x-ray tubes A focus index: 0.3*0.3mm2 B. The voltage of the-highest-voltage generator: 90kv C. The highest inverse peak voltage: 90kv D. Filament characteristic: vf=5v+0.5v, f=3a E. Target surface obliquity: 12 F. The cooling manner of bulb tube head: oil immersion The parameter of x-ray generator (bulb tube head): A. Focus-skin distance: 200mm B.The thickness of filter-ray film: more than 1.5mmal C.The leakage rate of x-ray: no more than 0.002mgy/h (no. 29.204.3 in gb9706.12 prescript that the leakage rate of x-ray is no more than 0.25mgy/h) D. The manner of limiting beam: using planigraphic device
Detecting such as stone ,sand,teflon,fe,sus ,non-fe,harder material and so on in the food stuff
Specifications: Tube Voltage): 60kV Tube Current: 1mA Exposure Time: 0.02~2S Tube Focus: 0.3*0.3mm Frequency: 30kHz Battery: DC14.8V 6400mA Rated Power: 60VA Charger Input: AC100V-240V±10% Charger Output:DC16.8V Weight:2.2kg Size:138*165*185mm The distance from skin to cone: 130mm
PLX101 Series High Frequency Mobile X-ray Equipment PLX101/101A/101C Rocker safety lock design, make your operate much safer High quality x-ray monoblock assures more details, less dose Symmetrical adjustable collimator for accurate positioning and better exposure protection Aviation aluminum connectors, connection reliable, more safety Advanced dislocation braking system, flexible movement, flexible braking Multifunctional cassette storage box design Features Our high frequency technology assures the best image in every operating condition Along with reduced patient dose and extended x-ray tube life time The generator provide the right amount of penetration, reducing exposure times and retakes. The parameter can be adjusted by the kV and mAs. Multiple security protect function such as over-voltage, over-current. 50 preset exposure programs allow extensive possibilities to optimize the exposure and processing parameters according to your preferences. Fault automatic protection setting and fault alarming display Parameters are automatically storage when power cut off. Adopt rotating beam limiting device to adjust the X-ray field and angle freely. Adopt manual controller and remote controller to do exposure. Optional: PLXF152 mobile table for high frequency mobile X-ray equipment. PLX101D is equipped with built-in battery, can take 200 films when full charged. Rocker can move up and down, automatically balance High quality X-ray monoblock can rotate in ±90 Options PLXF152 Mobile Bed For Mobile X-ray Machine Size: 2000 X 700X 500mm Range of grid box movement 1210mm Size of grid box: 430X 430(17 X 17) Bucky Stand Height: 1770mm Vertical movement range: 470-1470mm Grid density: 103L/inch Grid radio: 10:1 Focus distance: 150cm Maximum grid box: 17 X 17 Technical Parameters
X - Ray Tubes , CT tubes Our products are with german brand NAGO and german technology. We provide X-ray tubes for medical ,industry and inspection systems . The tubes can replace Siemens , Philips , Varian ,Toshiba ,IAE and other brand tubes . We provide also X-ray tube accessories like glassbulb, target , rotor and so on. Offering mechanical parts processing work according to customer's drawing and requirements .
100 mA, 100 KVP Mobile X-ray Machine 100mA, 100 KVP, Mobile X-ray Machine for Radiography only Electronic Timer Electronic Overload Protection Device Stationary Anode X-ray Tube : BEL or Imported Collimator Counter Balanced Mobile Stand Suitable for Bed Side X-rays
Suited to a range of imagers and general radiology applications Five film sizes on 7-mil blue polyester base AIQC system-matched with the DRYVIEW Laser Imagers AIQC ensures contrast and density meet preset user preferences Quality control performed without operator intervention to enhance productivity Storage and Handling of Film Unexposed DRYVIEW DVE Film must be stored at 39 to 75�?�°F (4 to 24�?�°C), at 30 to 50% RH, and properly shielded from x-rays, gamma rays, or other penetrating radiation in order to achieve consistent results up to the expiration date indicated on the film package. Note that DRYVIEW models 8700, 8150 and 8300 are not compatible with DVE Film. To determine if your laser imager needs a software upgrade or is compatible with DVE �¢?? download our information sheet here. Choose from five sizes on 7-mil polyester base to suit your DRYVIEW Laser Imager and imaging applications: 14 x 17 in. (35 x 43 cm.) 11 x 14 in. (28 x 35 cm.) 10 x 12 in. (25 x 30 cm.) 8 x 10 in. (20 x 25 cm.)
There are many different models available for an X-ray baggage scanner, depending on the location and purpose of the X-ray scanner. The tunnels of the x-ray baggage scanner are determined according to the place to be used. 50x30 tunnels are usually suitable for places entered with handbags, such as shopping mall entrances, public institutions, and organizations; as the size of the package to be controlled increases; 65x50, 80x65, or 100x100 will be more convenient. Sites such as airports, bus terminals, hotel entrances should prefer devices with large tunnel measurements.
We're a leading XRay machine and accessories manufacturer company with over 29 years of experience and global presence and distributor network in 7 different countries. We have Line Frequency & High Frequency, APR X-Ray Machine, Dental X-Ray Machine, Mobile 100MA X-Ray Machine, 300MA X-Ray Machine, 500MA XRay Machine, Vertical Bucky, Multi-Position Bucky Table, 4 & 2 Way Floating Bucky Table Etc Beside new machines, we offer complete modification & repairing of any brand XRay machines, Rotating Anode Tube Head, HT 100MA, 300MA, 500MA Etc
Power Output 5.0KW x ray machine Main Inverter frequency 40 KHz X-ray Tube of radiography machine fixed anode focus: 1.5 (X-ray tube for high frequency) Power Supply 220V�±10% 50Hz Inner-resistance â?¤1.0�© Operation Method Wire/wireless control mobile x-ray machine safety mobile x ray machine cost mobile x ray machine price