The instrument GF312D1 is a precision 0.05% AC energy meter testing instrument, mainly used to test three phase energy meter error on site, measure all various of AC parameters and CT ratio & phase error, it is also as three phase reference energy meter in the laboratory. Mainly using test single phase or three phase meter error on site. GF312D1 energy meter calibrator is an ideal test tool for the metrological service of electricity power company.
INTRODUCTION: The instrument is a precision AC energy meter testing instrument, mainly used to test three phase energy meter error on site and measure all various of AC parameters. FEATURES Three phase active or reactive electricity energy meter. Calibrate three phase, single phase, and active or reactive meter error. Measure U(voltage) of three phase or single phase. Measure I(current) of three phase or single phase. Measure active power of three phase or single phase. Measure reactive power of three phase or single phase. Measure apparent power of three phase or single phase. Measure power factor of three phase or single phase. Measure phase angle between voltage and current. Measure frequency of power line. Display vector diagram. Display waveform of U and I. Analyze and display content of harmonic of U and I. Measure 2-64 harmonic of U, I. Store and display measured data. Optional 5A, 20A, 100A, 500A, 1000A, 2000A, 3000A current clamp. Measure CT variable ratio. Measure the ratio or lag-angle of low-voltage transformer. Adopt 32 bit ARM processor, multi-channel 16 bit precision A/D convertor, high resolution TFT color LCD. Inner equipped with 0.01% wide-range current transformer and can be equipped with various type current clamps, wide range of measurement and high veracity. Low consumption circuit design, high energy Lithium battery supply, intellectual power management software, which enables the instrument continuously working up to 10 hours.
The Portable Three Phase kWh Meter test equipment is used for grid corporation of measurement and energy test center, management department of power supply bureau, national energy measurement of testing authorities, and also used to test each kind of single/three phase kWh meter of industries and mining enterprises as well as electric meter manufacturers. Meanwhile, the calibrator also can be used as one high precision standard power source.
Product Introduction this instrument is specially used to test power grid waveform distortion voltage fluctuation and flicker harmonic content and unbalanced three-phase power quality problems such as high precision testing instruments; at the same time it also have the the functions of electric parameter test the vector analysis. Product Characteristics Can accurately measure voltage current active power reactive power frequency phase Angle power factor and other electrical parameters It can display the measured voltage and current phasor diagram the users can know the device wiring correctly or not through the analysis of vector diagram . The current is measured by using the clamp transformer.Because using clamp current transformer measurementthe operators do not need to disconnect current loop can be measured convenient and safety. It can be equipped with different range of clamps according to the user's measurement range. It can measure and analysis the power quality from the utility grid to the client's use its measure and analysis frequency deviation voltage deviation voltage fluctuation and flicker unbalanced three-phase voltage allowed degrees and power grid harmonic. Can display the single phase voltage and current waveform and can also show three phase voltage and current waveform. All tests have screen lock function interface to facilitate users to reading and analyze the data.
Product Introduction this instrument is specially used to test power grid waveform distortion voltage fluctuation and flicker harmonic content and unbalanced three-phase power quality problems such as high precision testing instruments; at the same time it also have the the functions of electric parameter test the vector analysis. Product Characteristics Can accurately measure voltage current active power reactive power frequency phase Angle power factor and other electrical parameters It can display the measured voltage and current phasor diagram the users can know the device wiring correctly or not through the analysis of vector diagram . The current is measured by using the clamp transformer.Because using clamp current transformer measurementthe operators do not need to disconnect current loop can be measured convenient and safety. It can be equipped with different range of clamps according to the user's measurement range. It can measure and analysis the power quality from the utility grid to the client's use its measure and analysis frequency deviation voltage deviation voltage fluctuation and flicker unbalanced three-phase voltage allowed degrees and power grid harmonic. Can display the single phase voltage and current waveform and can also show three phase voltage and current waveform. All tests have screen lock function interface to facilitate users to reading and analyze the data.
Product description: Three Phase Energy Meter Field Calibrator is a precision AC energy meter testing instrument, mainly used to test three phase energy meter error on site and measure various of AC parameters. Technical index: Electrical parameters Accuracy class 0.05%, 0.1% Resolution 6 TFT (640-480) Electrical parameters - continued Power supply 220V±10%, 50/60Hz Li-polymer battery (size (mm): 110x51x16, nominal output voltage: 7.2V, capacity: 5000mAh) Power line supply (U1, UN), 85V-265V 50/60Hz Communication port RS232 Test voltage Range 5-480V Error ±0.05% (30V-480V) ±0.1% (5V-30V) Harmonic 2nd-63st Test current Range (direct connection) 5mA-20A Error (direct connection) ±0.05% (100mA-20A) ±0.1% (10mA-100mA) Range (clamp CT) 10mA-3000A Error (camp CT) �±0.2% (100mA-100A) ±0.5% (100A-3000A) Harmonic 2nd-63st
Product description Three Phase Energy Meter Field Calibrator is a precision AC energy meter testing instrument, mainly used to test three phase energy meter error on site and measure various of AC parameters. Technical index Electrical parameters Accuracy class 0.05, 0.1 Resolution 6 TFT 640 480 Electrical parameters - continued Power supply 220V 10%, 50 60Hz Li-polymer battery size mm 110 51 16, nominal output voltage 7.2V, capacity 5000mAh Power line supply U1, UN, 85V-265V 50 60Hz Communication port RS232 Test voltage Range 5-480V Error 0.05% 30V-480V 0.1% 5V-30V Harmonic 2nd-63st
System description: Introducing new epa 300, a portable standard meter Used for the measurement of the three phase power And the energy. Various measuring features combined with its easy operation concept provide the greatest possible flexibility for a comprehensive testing of metering installations on site. Features: 1. On line calibration with external ct 2. Direct current option up to 10a 3. Accuracy < 0.2% 4. Large lcd display. 5. Pulse input & output 6. Sensor for pulse out led Functions: 1. Power and energy measurement of active, reactive and apparent energy 2. Frequency-, phase angle- and power factor measurement. 3. Error measurement on electric meters. Actual values measurement: 1. Rms values of all voltage and current phases 2. Currents for all 3 phases 3. Frequency and power factor - cos ϕ. 4. 3 phase - kw, kwh, kva, kvar, kvarh 5. Percentage of the measurement error with pulse input. Technical data: 1. Power supply: 85-250vac, 50/60hz. 2. Voltage measurement: 0……300v 3. Voltage measurement accuracy: < 0.1% 4. Current measurement: 50ma ….10a (for direct measurement)1 a…1000a (for measurement with clip -on ct) 5. Current measurement accuracy: direct measurement
GF312B portable three phase energy meter calibrator with printer is used to calibrate three phase, single phase, active and reactive energy meters error. And it also can be used as voltage, current and power meter to measure AC parameters of three phase power line. It can measure wave distortion factor and 2nd to 64nd harmonic wave. GF312B calibrator is used for grid corporation of measurement and energy test center, metrological service of power supply bureau, national energy measurement of testing authorities.
Product description Three-phase electric energy meter calibrator is used for grid corporation of measurement and energy test center, management department of power supply bureau, national energy measurement of testing authorities, and also used to test each kind of single/three-phase kWh meter of industries and mining enterprises as well as electric meter manufacturers. Meanwhile, the calibrator also can be used as one high-precision standard power source. Technical index Electrical parameters Accuracy 0.05%, 0.1% Power Supply One Phase AC 180-265V, frequency 50/60Hz. AC Voltage Output Range(U1,U2,U3) 57.7V, 100V, 220V, 380V or 69.3V, 120V, 240V, 480V( optional) Adjustment range (0-120)%RG(1) Adjustment �neness 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional. Electrical parameters - continued AC Voltage Output - continued Stability 0.01%/120s Distortion 0.3% (Non-capacitive load) Output load each phase 25VA Measuring accuracy 0.05%RG AC Current Output Range(I1,I2,I3) 200mA, 1A, 5A, 20A, 100A Adjustment range (0-120)%RG Adjustment �neness 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional. Stability
Three Phase Energy Meter with following features - Dual Source - Prepaid Function with inbuilt relays - Whole Current - Load Curtailment - Modbus/RS485 Protocol Communication - 10-60 Amps Customization as per requirement also possible
GF312B portable three phase energy meter calibrator with printer is used to calibrate three phase, single phase, active and reactive energy meters error. The instrument has a micro printer and portable design. It is very suitable for on-site calibration of electric energy meters. Feature: 1.accuracy:0.05%,0.1%,0.2% 2.Test range:0-600V; 3.With printer 4.Harmonic:2-64times 5.Weight: 12kg 6.IP65
INTRODUCTION GF312V2 portable three phase multifunction energy meter calibrator is with comfort design, small size, and light weight. It is suit for electric power departments, measuring and quality examining departments and electric lab to field use. TECHNICAL SPECIFICATION Electrical parameters Accuracy class 0.05%, 0.1% Power Supply External power, 220V/110V, 50/60Hz Phase voltage supply 45-450V, 50/60Hz Li-Battery supply Voltage measurement Range 30-560V Error ±0.05% Harmonic 2nd-51st Current measurement Range (direct connection) 0.01-10A Range (clamp CT) 5A,100A,500A,1000A,2000A (option) Error (direct connection) ±0.05% Error (clamp CT) ±0.2% (5A, 100A ) ±0.5% (other) Harmonic 2nd-51st Power measure error Active power (direct connection) ±0.05% Active power (clamp CT) ±0.2% (5A, 100A) ±0.5% (other) Reactive power (direct connection) ±0.1% Reactive power (clamp CT) ±0.2% (5A, 100A) ±0.5% (other) Energy measure error Active energy (direct connection) ±0.05% Active energy (clamp CT) ±0.2% (5A, 100A) ±0.5% (other) Reactive energy (direct connection) ±0.1% Reactive energy (clamp CT) ±0.2% (5A, 100A) ±0.5% (other) Phase angle Range 0-360 Resolution 0.01 Error ±0.05 Frequency Range 45Hz-65Hz Resolution 0.001Hz Error 0.002Hz Pulse output Energy constant 25000 Pulse ratio 1:1 Output level 5V Pulse input Input channel 2 Input level 5-10V Input frequency Max. 100Hz Display Resolution 7 TFT color (480-234) Function Vector diagram Waveform Energy accumulation CT ratio test Local parameter input Wiring emulation Self-calibration Recorder check Data storage Data storage qty 5000 External extend memory Screen printing Communication port USB/RS232 Communication with PC Upload data External mini printer External keyboard Dimensions (WHD) (mm) 245-16870 Weight (kg) 1.8 Environmental conditions Ambient temperature -25C to +45C Relative humidity 30%-95%
GF312V2 portable three phase multifunction watt-hour meter calibrator on-site is the newest product produced by our company by widely visiting users and referring to the advantages of the same kind of products home and abroad. The measured part of the product adopts high speed A/D transmission to send DSP to conduct digital processing, which largely improves measured degree of accuracy and stability. Central processing part adopts 32-bit ARM embedded technology to make instrument interface novel, function abundant, operation distinct and easy, and performance steady. Class of accuracy: Class 0.02, 0.05 or 0.1, range from 12A/600V or 120A/600V, with comfort design, small size and light weight. The model GF312V2 watt-hour meter calibrator is suit for electric power departments, measuring and quality examining departments and electric lab to field use.
INTRODUCTION The GF302D1 three phase portable energy meter test system consists of an integrated three phase current and voltage source(up to 500V/120A or 500V/20A) and built-in three-phase electronic reference standard of accuracy class 0.05%. Characteristic features of the GF302D1 are its wide measuring range, high accuracy and high tolerance to unwanted external influences. The equipment offers high functionality combined with an excellent menu guided operation via built-in keyboards and colored 7 touch LCD-display. PARAMETERS Accuracy class 0.05%, 0.1% Power supply One Phase AC 100-265V, frequency 50/60Hz. AC Voltage output Range(U1,U2,U3) 57.7V, 100V, 220V, 380V or 69.3V, 120V, 240V, 480V( optional) Adjustment range (0-120)%RG(1) Adjust fineness 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional. Stability 0.01%/120s Distortion 0.3% (Non-capacitive load) Output load each phase 30VA Measuring accuracy 0.05%RG AC Current output Range (I1, I2, I3 ) 200mA, 1A, 5A, 20A, 100A(optional) Adjustment range (0-120)%RG Adjustment fineness 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional. Stability
Product Description Major technical data: Accuracy class: 1.0 Power consumption: 20 years. Main functions: 1) Measurement of 50hz for 3-phase active power 2) 4 tariffs and 8 time periods for user's option 3) RS 485 communication functions 4) Manual and remote control program, and remote-metering functions 5) To record the parameters automatically through CMRI. Features: 1) High accuracy, reliability, overload capability 2) Low power consumption 3) Smt technology and re-flow soldering technology 4) Light weight, small size, easy to install. Model: DTSF318/DSSF318 Standard: IEC 62052-11 IEC 62053-21 IEC 62056-21 Productivity: 100.000pcs/year.
DESCRIPTION Adopting large scale IC and SMT processes,the DTSD1088 DLMS meter is made to accurately total active/reactive energy,forward and reverse active/reative energy and maximum demand.And in real-time it also measures and takes in process parameters like active/reactive power,apparent power,Voltage,current,power factor,frequency and so on,and implements time-of-use control,automatic stroge of reading-day demand,and records load profile and events.And with infrared,RS485,PLC communications equipped,the DTSD1088 DLMS meter is an ideal device to realize time-of use energy measurement and efficient processing in ease.It complies with applicable standards of IEC62052-11,IEC62053-21,IEC62053-61,IEC62054-21,IEC62056-61,IEC62059-11,IEC62059-21. FEATURES 1. Energy measurement (separate and total):Forward and reverse,active,four-quadrant,time-of use,sub-phase. 2. Demand record 3. Real-time parameters 4. Data archive 5. Data freezing 6. Events record 7. Optional infrared,PLC,M-BUS,Ethernet,GPRS communication
DESCRIPTION DTSD1088 three phase multifunctional meter is made to accurately measures total active/reactive energy, forward and reverse active/reactive energy and maximum demand. And in real-time it also measures and takes in process parameters like active/reactive power, apparent power, voltage, current, power factor, frequency and so on, and implements time-of-use control, automatic storage of reading-day demand, and records of load profile and events. DTSD1088 meter realizes time of use energy measurement and efficient processing in ease. It complies with applicable standards of IEC62052-11, IEC62053-21, IEC62053-23, IEC62053-661, IEC62054-21, IEC62056-61, IEC62059-11 and IEC62059-21. FEATURES 1.Customized meter design for Finland Utility. 2.Special terminal block connection for easy wiring. 3.Terminal cover &front cover with detecting features. 4.With backup battery for RTC. 5.Load Profile(Optional) 6.MD measurement 7.Over-load protection: Automatic power-off as load exceeds the specified value(optional) 8.With optical communication port(IEC1107) 9.Open protocol: DLMS/COSEM(Optional)
DESCRIPTION DTSD1088 three phase multifunctional meter is made to accurately measures total active/reactive energy, forward and reverse active/reactive energy and maximum demand. And in real-time it also measures and takes in process parameters like active/reactive power, apparent power, voltage, current, power factor, frequency and so on, and implements time-of-use control, automatic storage of reading-day demand, and records of load profile and events. With infrared, RS485, PLC and GPRS communication equipped, DTSD1088 meter realizes time of use energy measurement and efficient processing in ease. It complies with applicable standards of IEC62052-11, IEC62053-21, IEC62053-23, IEC62053-661, IEC62054-21, IEC62056-61, IEC62059-11 and IEC62059-21. FEATURES 1.Functional LCD displays(menu driven, scrolling function, IR remote control mode) 2.Events record: Power-on/power-off (latest ten time), power quality monitoring(10 times), meter cover open(10 times recorded and can be read by MDM software). 3.Load curve recording: Active/reactive energy, voltage(3 phases), current(3 phases), power factor(3 phases) and time stamp(DD/MM/HH/YY) 4.External relay 5.Over-load protection: Automatic power-off as load exceeds the specified value(optional) 6.RTC, broadcast time synchronization via communication interface(could be set by GPS time via the MDM) 7.Optional multi-communication: PLC based on OFDM according to CENELEC standards(A-band), GPRS(SIMCOM-chip), RS485, integrated M-Bus(extended connection to gas and water meters) according to OMS standard. 8.Open Protocol: DLMS/COSEM 9.Advanced AMI integration (Optional)