DESCRIPTION Adopting large scale IC and SMT processes,the DTSD1088 DLMS meter is made to accurately total active/reactive energy,forward and reverse active/reative energy and maximum demand.And in real-time it also measures and takes in process parameters like active/reactive power,apparent power,Voltage,current,power factor,frequency and so on,and implements time-of-use control,automatic stroge of reading-day demand,and records load profile and events.And with infrared,RS485,PLC communications equipped,the DTSD1088 DLMS meter is an ideal device to realize time-of use energy measurement and efficient processing in ease.It complies with applicable standards of IEC62052-11,IEC62053-21,IEC62053-61,IEC62054-21,IEC62056-61,IEC62059-11,IEC62059-21. FEATURES 1. Energy measurement (separate and total):Forward and reverse,active,four-quadrant,time-of use,sub-phase. 2. Demand record 3. Real-time parameters 4. Data archive 5. Data freezing 6. Events record 7. Optional infrared,PLC,M-BUS,Ethernet,GPRS communication
DESCRIPTION DTSD1088 three phase multifunctional meter is made to accurately measures total active/reactive energy, forward and reverse active/reactive energy and maximum demand. And in real-time it also measures and takes in process parameters like active/reactive power, apparent power, voltage, current, power factor, frequency and so on, and implements time-of-use control, automatic storage of reading-day demand, and records of load profile and events. DTSD1088 meter realizes time of use energy measurement and efficient processing in ease. It complies with applicable standards of IEC62052-11, IEC62053-21, IEC62053-23, IEC62053-661, IEC62054-21, IEC62056-61, IEC62059-11 and IEC62059-21. FEATURES 1.Customized meter design for Finland Utility. 2.Special terminal block connection for easy wiring. 3.Terminal cover &front cover with detecting features. 4.With backup battery for RTC. 5.Load Profile(Optional) 6.MD measurement 7.Over-load protection: Automatic power-off as load exceeds the specified value(optional) 8.With optical communication port(IEC1107) 9.Open protocol: DLMS/COSEM(Optional)
DESCRIPTION DTSD1088 three phase multifunctional meter is made to accurately measures total active/reactive energy, forward and reverse active/reactive energy and maximum demand. And in real-time it also measures and takes in process parameters like active/reactive power, apparent power, voltage, current, power factor, frequency and so on, and implements time-of-use control, automatic storage of reading-day demand, and records of load profile and events. With infrared, RS485, PLC and GPRS communication equipped, DTSD1088 meter realizes time of use energy measurement and efficient processing in ease. It complies with applicable standards of IEC62052-11, IEC62053-21, IEC62053-23, IEC62053-661, IEC62054-21, IEC62056-61, IEC62059-11 and IEC62059-21. FEATURES 1.Functional LCD displays(menu driven, scrolling function, IR remote control mode) 2.Events record: Power-on/power-off (latest ten time), power quality monitoring(10 times), meter cover open(10 times recorded and can be read by MDM software). 3.Load curve recording: Active/reactive energy, voltage(3 phases), current(3 phases), power factor(3 phases) and time stamp(DD/MM/HH/YY) 4.External relay 5.Over-load protection: Automatic power-off as load exceeds the specified value(optional) 6.RTC, broadcast time synchronization via communication interface(could be set by GPS time via the MDM) 7.Optional multi-communication: PLC based on OFDM according to CENELEC standards(A-band), GPRS(SIMCOM-chip), RS485, integrated M-Bus(extended connection to gas and water meters) according to OMS standard. 8.Open Protocol: DLMS/COSEM 9.Advanced AMI integration (Optional)
DESCRIPTION The DDSY1088 single phase two wire postpaid meter is made of high quality optimized long life components and designed in advanced SMT technique with good performances on reliability, accuracy and load ranges.DDSY1088 provides metering solution benefiting both consumers and power utilities. It complies with the applicable standards of IEC1036, IEC62052-11, IEC62053-21. FEATURES 1. High accuracy measurement with LCD display,5 integers. 2. Wide operating voltage range 0.8Un ~ 1.15Un. 3. Long time precisely works without calibration and limit error linear maintains flat during heavy loading from start to end. 4. With active impulse LED indicator and reverse energy LED indicator 5. With cover of terminal block made by transparent material. 6. Measures active energy,reactive energy and reverse always add to positive. 7. Meter base and cover ultrasonic sealed 8. The communication between meter and CIU is PLC
Three Phase Energy Meter with following features - Dual Source - Prepaid Function with inbuilt relays - Whole Current - Load Curtailment - Modbus/RS485 Protocol Communication - 10-60 Amps Customization as per requirement also possible
Standards 1, IEC62052-11:2003 2, IEC62053-21:2003 Features 1.Measurment: Measure total active energy and tariffs. 2.Meaure total active max demand and four tariffs total active max demand. 3.multi-tariff function. 4.Record previous 12 months data.
1, The core components are all imported, adopting the sixth generation IPM module from Mitsubishi, which has stable performance, long service life, strong protection functions and convenient replacement and maintenance. 2, Adopt the central processor DSP28335 chip from American TI Company, respond quickly and accurately, and provide stable and clean power for the load to provide protection. 3, The whole machine adopts modular design and plug-in design, which is convenient for maintenance and reduces the hidden cost of machine failure to repair. 4, According to the product configuration conditions, adjustment the system usage mode: DC(Battery/Solar) priority or AC mains bypass priority can be set. 5, Two kinds of start mode: Reduction Voltage Start and Variable Frequency Start. Customers can set start mode according to the type of their load. This function is very convenient for users and also reduce frequency converterâ??s usage, which reduced the cost of equipment investment, easy to connect wires and control. 6, The output voltage can be set between -40 % to +20 % of rated voltage. And the output voltage is very accuracy �±1%. 7, The DC input voltage range can be set. Over-voltage point, under-voltage point, over-voltage recovery point, under-voltage recovery point all can be setting via the LCD panel. 8, Output AC Power is suitable for all types of electrical equipment, CNC machines, electric tools, motors, pump and air conditioner etc. It has higher efficiency and higher capability of driving load. 9, Humanized safety design, using isolation transformer design, input and output are completely electrically isolated, input and output are equipped with circuit breakers, which saving costs for the user and easy to installation, the electric parts are completely closed to prevent electric shock. 10, Wide input voltage can be set according to customer's requirement. Input voltage range can be selected from 100-300V, 200-500V or 500-850V, suitable for solar/wind system without backup batteries, it can save many cost and maximization use the solar/wind energy. 11, Using SVPWM space vector algorithms, high conversion efficiency, high instantaneous power and low losses conversion efficiency up to 94%. 12, Powerful data display function. LCD + LED display, can display input and output voltage, current, KWH, fault display, convenient for customers to quickly find faults and guide maintenance. 13, European CE (EMC, LVD, UL1741) and ISO9001 certificates. [Optional] A, RS485 communication; B, AC bypass complementary function; C, Built-in charger
Product description Three-phase electric energy meter calibrator is used for grid corporation of measurement and energy test center, management department of power supply bureau, national energy measurement of testing authorities, and also used to test each kind of single/three-phase kWh meter of industries and mining enterprises as well as electric meter manufacturers. Meanwhile, the calibrator also can be used as one high-precision standard power source. Technical index Electrical parameters Accuracy 0.05%, 0.1% Power Supply One Phase AC 180-265V, frequency 50/60Hz. AC Voltage Output Range(U1,U2,U3) 57.7V, 100V, 220V, 380V or 69.3V, 120V, 240V, 480V( optional) Adjustment range (0-120)%RG(1) Adjustment �neness 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional. Electrical parameters - continued AC Voltage Output - continued Stability 0.01%/120s Distortion 0.3% (Non-capacitive load) Output load each phase 25VA Measuring accuracy 0.05%RG AC Current Output Range(I1,I2,I3) 200mA, 1A, 5A, 20A, 100A Adjustment range (0-120)%RG Adjustment �neness 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional. Stability
Pure sine wave off grid inverter, energy storage lithium battery, solar charge controller, ac/dc battery charger and single phase to 3 phase converter, pv combiner box and power supply.
Product Description Major technical data: Accuracy class: 1.0 Power consumption: 20 years. Main functions: 1) Measurement of 50hz for 3-phase active power 2) 4 tariffs and 8 time periods for user's option 3) RS 485 communication functions 4) Manual and remote control program, and remote-metering functions 5) To record the parameters automatically through CMRI. Features: 1) High accuracy, reliability, overload capability 2) Low power consumption 3) Smt technology and re-flow soldering technology 4) Light weight, small size, easy to install. Model: DTSF318/DSSF318 Standard: IEC 62052-11 IEC 62053-21 IEC 62056-21 Productivity: 100.000pcs/year.
1.Starting test and creeping test 2.Measuring the different constant meters synchronously. 3.With the protect function of overload, short voltage circuit and open current circuit. 4.The testing software with friendly windows 2000 and xp interface, include functional module of all kinds of modern energy meter needed, to reality error test, harmonic test, demand test, influence test. 5.The stored testing data can be transferred to multi-format for other program using
Features: 1. Check the error of active and reactive of watt-hour meter at the same time, and meanwhile check the error of main and secondary meter in the same circuit. 2. Display the electrical constants such as: voltage, current, power, power factor, phase and frequency and etc. 3. Measure ct ratio, wave form display. 4. Measure 2-51 voltage and current harmonics. 5. Judge wrong wiring. 6. Measure the baud rate for multi-function energy meter and meter number reading. ¦ct secondary loading function. 8. Automatically correct the clamp error.
.1 Description DEM8900-1/DEM8900-2/DEM8900-3 (short form for DEM8900) is designed by adopting the updated microprocessor and digital signal processing technology, which can be applied for monitoring the electrical system. DEM8900 can measure and analyze the real time electrical parameters, such as I,kWh,kvarh., Meanwhile, DEM8900 has functions of multi-tariff,RS485 communication ( MODBUS protocol),analog output, remote input and electrical pulse output. All our instruments fulfill all important requirements and regulations concerning electromagnetic compatibility and safety isolation (IEC61000, IEC1010 standard and EN61010 standard). The devices have been developed, manufactured, and tested in accordance with Quality Assurance System ISO 9001. 1.2 Measured parameters Note 1. DEM8900-1 measure current, active energy, active power (optional, with analog output) 2. DEM8900-2 measure current, reactive energy, reactive power (optional, with analog output) 3. DEM8900-3 measure Current, active energy, reactive energy, active/reactive power (optional, with analog output) 1.3 EMC and Safety standard IEC61000-4-2 (GB/T17626.2) IEC61000-4-8 (GB/T17626.8) IEC61000-4-4 (GB/T17626.4) IEC61010-1 (GB/T4793.1). Exterior Size:91*91*72mm 0.5KGS.
Overview: The RT6303-S Three Phase Energy Meter Test Instrument(Split Type) adopts internationally advanced new-generation digital power source technologt,integrates all the technological advantages of both domestic and foreign watt-hour meter calibration software, and is introduced to global market by Rowwin Test in a powerful and sensational way.The Three phase energy meter test instrument¡¯s power source uses MCU single chip microprocessor as its core technology and adopts various techniques as digital synthesis,digital frequency modulation,digital amplitude modulation,digital phase-shifting,pulse width modulation and so on to bring you such important features as high reliability and good load characteristics.Its more humane and intelligent meter calibration software makes it possible for an ordinary,heavy and boring calibration to be carried out more easily and efficiently. Technical Parameters: 1. Accuracy class: 0.1/0.05 2. Reference standard energy meter: Three phase wide-measurement range standard energy meter,Accuracy class:0.1/0.05 3. Output voltage: 3* 57.7/100/220/380V Y/¡÷,0~120%Adjustment fineness:0.01% full range,adjustable phase by phase 4. Output current: 3* 0.1~100A(200A also available),0~120%Adjustment fineness:0.0001A(minimum),adjustable phase by phase 5. Phase shift:0~360¡ãAdjustment fineness:0.01¡ã,adjustable phase by phase 6. Frequency:45Hz~65Hz,Adjustment fineness:0.01Hz 7. Output waveform distortion:Both voltage and current
Product description: Three Phase Energy Meter Field Calibrator is a precision AC energy meter testing instrument, mainly used to test three phase energy meter error on site and measure various of AC parameters. Technical index: Electrical parameters Accuracy class 0.05%, 0.1% Resolution 6 TFT (640-480) Electrical parameters - continued Power supply 220V±10%, 50/60Hz Li-polymer battery (size (mm): 110x51x16, nominal output voltage: 7.2V, capacity: 5000mAh) Power line supply (U1, UN), 85V-265V 50/60Hz Communication port RS232 Test voltage Range 5-480V Error ±0.05% (30V-480V) ±0.1% (5V-30V) Harmonic 2nd-63st Test current Range (direct connection) 5mA-20A Error (direct connection) ±0.05% (100mA-20A) ±0.1% (10mA-100mA) Range (clamp CT) 10mA-3000A Error (camp CT) �±0.2% (100mA-100A) ±0.5% (100A-3000A) Harmonic 2nd-63st
The instrument GF312D1 is a precision 0.05% AC energy meter testing instrument, mainly used to test three phase energy meter error on site, measure all various of AC parameters and CT ratio & phase error, it is also as three phase reference energy meter in the laboratory. Mainly using test single phase or three phase meter error on site. GF312D1 energy meter calibrator is an ideal test tool for the metrological service of electricity power company.
The GF302D3 portable three phase energy meter test bench consists of an integrated three phase 120A current source and 600V voltage source and a class 0.02 three phase electronic reference standard meter. The energy meter test bench is particularly designed for analysis of complete metering installations and local mains conditions. The meter test bench offers high functionality combined with an excellent menu guided operation via built-in thirty keys and colored 7" touch LCD-display. It can auto & manual test all kinds of energy meter error. Using on site or in the laboratory. It can preset a variety of test schemes for testing energy meter.
The GF302D1 three phase portable energy meter test equipment consists of an integrated three phase current source(up to 500V/120A or 500V/20A) and built-in three-phase electronic reference standard of accuracy class 0.05%. Characteristic features of the GF302D1 are its wide measuring range, high accuracy and high tolerance to unwanted external influences. The equipment offers high functionality combined with an excellent menu guided operation via built-in keyboards and colored 7" touch LCD-display. Voltage & current harmonics output from 2 to 63 times. This model portable meter test equipment can be programmable by PC, automatic generation of energy meter error test report.