Ethicon, a subsidiary of Johnson & Johnson, is a well-known manufacturer of surgical products, including staplers and cutters. Key features and characteristics of the Ethicon Echelon 60 Endoscopic Linear Cutter may include: Endoscopic Application: The Echelon 60 is designed for use in endoscopic or laparoscopic procedures, allowing surgeons to perform surgeries through small incisions. Linear Cutting: It is categorized as a linear cutter, indicating its ability to make linear incisions or cuts in tissues. This is commonly used for procedures like bowel resections or other surgeries requiring precise cutting and stapling. Stapling Mechanism: In addition to cutting, the device typically includes a stapling mechanism. The stapling function is important for creating secure anastomoses (connections) or closures in surgical procedures. Various Staple Sizes: The Echelon 60 may offer multiple staple sizes to accommodate different tissue thicknesses and surgical requirements. Reloadable Cartridges: The device often uses reloadable cartridges containing staples, allowing surgeons to perform multiple staple applications without having to change the entire device. Advanced Surgical Techniques: The Echelon series is known for incorporating advanced technologies to enhance the precision and efficiency of surgical procedures.
"Bipolare Pinzette SuperGliss" likely refers to bipolar forceps with a feature or technology named "SuperGliss." Here's a general description of the components: Bipolar Forceps: Bipolar forceps are surgical instruments used in various medical procedures, especially those requiring precise control of electrical current. They are often used in electrosurgery for tasks such as coagulation. SuperGliss: "SuperGliss" may be a proprietary technology or feature associated with the bipolar forceps. It could imply a specific coating, design, or functionality that enhances the performance or ease of use of the forceps.
Covidien ABSTACK30 Absorbatack Fixation Device Part # ABSTACK30 Exp 3/19 Covidien ABSTACK30 Absorbatack Fixation Device is an absorbable tack fixation device, for use in laparoscopic hernia repair. The NEW AbsorbaTack (ABSTACK30X) fixation device for laparoscopic hernia repair continues to deploy tacks when the shaft is flexed over 3 cm. Covidien ABSTACK30 Absorbatack Fixation Device Features Designed with patient comfort in mind No metal required for fixation Supports a minimally invasive approach through 5 mm shaft and easy-to-use design Fixation strength Provides strong temporary mesh fixation, with retention strength comparable to the â??gold standardâ?? ProTackâ?¢ fixation device at 1 week and 2 months in an animal model1 Peace of mind Reduces the likelihood of inadvertent needle sticks in the OR, since no sharp piloting needles are required for deployment Potentially fewer visceral attachments than permanent tack fixation1 Violet tack with black-dot visualization feature to optimize visibility In Perfect sealed condition but past expiration date. Not for human use in the US. Expiration dates have mostly to do with sterilization and not the integrity of the product. The manufacturers sterilize the products after they are packaged and it lasts so many years. The only products we caution customers about are ones that are absorbable or drug coated.
Echelon Endopath Staplers with gray, white, blue, gold, and green reloads deliver six staggered rows of staples with a single cut line in-between. A safety lock-out feature in the Ethicon reloads is designed to prevent a used reload from being re-fired. A staple retaining cap on the Echelon reload, protects the staple leg points during shipping and transportation. All Echelon Endopath Cartridges are compatible only within the Echelon Endopath Family of Staplers. Wide range of cartridges: Accommodates various tissue thicknesses, all with 6-row stapling capability. All cartridges fit through a 12mm trocar. Endoscopic Linear Cutter Reloads
Gripping Surface Technology Bariatric Surgery cartridges The Echelon+ Stapler advances security to deliver fewer leaks at the staple line and better staple formation, even in challenging conditions.
this is use for gastrpoic procedure Olympus GIF-H170 Gastroscope in excellent condition
- Ethicon Echelon 60 Endopath Stapler Reload - Blue 6 Rows Reload For Endopath60 Stapler 60mm 3.5mm - Echelon60 - Blue 3.5mm, 6 Rows
Long Articulating Endoscopic Linear Cutter Articulating Shaft 60mm Staple Line For use with any ECHELON60 Reload
Circular Stapler, 31 mm Size, Green, Titanium (Staples), Circular, 22 or 35 cm Shaft Length, Squeeze Handle, DST Series Staple Technology, Tilt-Top Anvil Stapler, 4.8 mm Open Height, Single-Use, Sterile
Bariatric Surgery cartridges The Echelon+ Stapler advances security to deliver fewer leaks at the staple line and better staple formation, even in challenging conditions.
Surgical diathermy Electric Bistori Electro surgical unit Cautery
Surgical Mist Blower Snugger Set Chest Drainage Catheter Under Water Seal Drainage System
Description 60mm Gold Reload Brand ECHELON ENDOPATH Staple Technology B-Form Device Technology Natural Articulation Size 60mm Color Gold Staple Rows 6 Tissue Thickness Regular/Thick Open Staple Height 3.8mm Closed Staple Height 1.8mm Category Surgical Stapling QTY/BX 12
Description 60mm Gold Reload Brand ECHELON ENDOPATH Staple Technology B-Form Device Technology Natural Articulation Size 60mm Color White Staple Rows 6 Tissue Thickness Regular/Thick Open Staple Height 3.8mm Closed Staple Height 1.8mm Category Surgical Stapling QTY/BX 12
Description 60mm Green Reload Brand ECHELON ENDOPATH Staple Technology B-Form Device Technology Natural Articulation Size 60mm Color GREEN Staple Rows 6 Tissue Thickness Thick Open Staple Height 4.1mm Closed Staple Height 2.0mm Category Surgical Stapling QTY/BX 12
Description 60mm Green Reload Brand ECHELON ENDOPATH Staple Technology B-Form Device Technology Natural Articulation Size 60mm Color GREEN Staple Rows 6 Tissue Thickness Thick Open Staple Height 4.1mm Closed Staple Height 2.0mm Category Surgical Stapling QTY/BX 12
GST60G ECHELON ENDOPATH Control Tissue Slippage During Firing 4x less tissue slippage for the most precise transection. Uniquely designed for better grip to provide the least tissue slippage§ for the most precise transection. Proprietary Gripping Surface Technology provides superior tissue grip without additional trauma during firing. This means you can transect more of the tissue you intended - especially in very thick tissue - with each firing.
GST60B ETHELON Control Tissue Slippage During Firing 4x less tissue slippageâ? for the most precise transection. Uniquely designed for better gripâ?¡ to provide the least tissue slippage§ for the most precise transection. Proprietary Gripping Surface Technology provides superior tissue gripâ without additional trauma during firing. This means you can transect more of the tissue§ you intended - especially in very thick tissue - with each firing.
ADVAPD Suture is synthetic absorbable sterile surgical suture composed of a copolymer made from polyester and Polydioxanone. The advanced extrusion process of the molecule of Polydioxanone gives ADVAPD: ADVAPD Suture is indicated for use in soft tissue approximation, including use in pediatric cardiovascular tissue where growth is expected to occur and ophthalmic surgery. PDS II Suture is not indicated in adult cardiovascular surgery, microsurgery and neural tissue. ADVAPD Suture is particularly useful where the combination of an absorbable suture and extended wound support (up to six weeks) is desirable. ADVAPD Suture, being absorbable, is not to be used where prolonged (beyond six weeks) approximation of tissues under stress is required and is not to be used in conjunction with prosthetic devices (i.e. heart valves or synthetic grafts). Suture absorption occurs by means of hydrolysis. Absorption begins as a loss of tensile strength followed by a loss of mass.
ADVALON Suture is indicated for use in general soft tissue approximation and/or ligation, including use in cardiovascular, ophthalmic, and neurological procedures. ADVALON Suture elicits a minimal acute inflammatory reaction in tissue, which is followed by a gradual encapsulation of the suture by fibrous connective tissue. While nylon is not absorbed, progressive hydrolysis of the nylon in vivo may result in gradual loss of tensile strength over time. Due to the gradual loss of tensile strength which may occur over prolonged periods in vivo, nylon suture should not be used where permanent retention of tensile strength is required. Features Benefits Excellent pliability Provides exceptional handling and knot tying properties Monofilament construction Easy passage through tissue with low frictional co-efficient Inert polymer Ideal for infected wound closure Suture of choice for desired cosmetic outcomes Excellent elasticity Superior tactile feedback to the surgeon, minimal suture breakage Tyvek packaging Durable protection & long lasting sterility Gamma radiation of sterilization Environmental friendly & less hazardous 300 Series premium cutting needles Strong & sharp needles for minimal bending & desired cosmetic outcomes Durable silicon coated needles Significantly enhanced initial and multi-pass penetration Ribbed bodied needles Better grasping & superior needle control