DC9V battery powered smoke alarm.
Smoke detector Specification: 1. Battery operated: dc 9v. 2. Rechargeable lion battery 10 year 9 dc battery. 3. Photoelectric sensor. 3. Red led indicate alarm. Green led mains indicator light to confirm battery power supply 4. Test button, low battery alarm 5. Relay contacts-volt free with normally open and normally closed options and rated to 24 volts/1 amp resistive. 6. Alarm supplied with "connector plug" for easy of installation, built in sounder to give a minimum sound output of 85 db at 3 m senses smoke using the light scatter principle-quick response to visible smouldering smoke, test button simulates smoke- use to check performance at least monthly, option current
Model No. SR-812DC-4 Operating voltage DC9~35V Alarm temperature 57 Static current 13mA(NC);4mA(NO) Alarm current 9mA(NC);19mA(NO) Alarm output Relay output Installation Ceiling mounted Sensitivity 2.06%ft±1.3%ft Working environment -10~+50(â?¤95%RH No congelation) Dimension 100*46mm
Supply voltage: 9 V DC Sensor type: photoelectric sensor Power Type: Battery (1 x 6F22 9V) Alarm Current: 20-50mA Recommended installation location: ceiling or wall Sound level: 85 dB Flash alarm indicator: red Test button: Yes Low battery indication: Yes Temperature range of sensor operation: 0C ~ + 50C Dimensions: 110 x 28 mm Packaging type: Color box
Smoke detector
Place of Origin: Guangdong, China (Mainland) Brand Name: SUMRING Model Number: SR-820PHS COLOR: whitePower: 9V BatteryAlarm output: sound and flash alarm Photoelectric sensing technology: yes Sending frequency: N/ASensitivity: 2.06%ft±1.3%ft Sound level: 85dB/3m Installation: Wall or Ceiling mountedDimension: 128*38mm
Place of Origin: Guangdong, China (Mainland) Brand Name: SUMRING Model Number: SR-820PHS COLOR: whitePower: 9V BatteryAlarm output: sound and flash alarm Photoelectric sensing technology: yes Sending frequency: N/ASensitivity: 2.06%ft±1.3%ft Sound level: 85dB/3m Installation: Wall or Ceiling mountedDimension: 128*38mm
Model NO SR-825PHS Operating voltage 3V lithium battery Static current 8uA Alarm current 35mA Alarm output Sound & Flash alarm Sound level 85dB/3m Installation Ceiling mounted Sensitivity 1.8%ft ±0.8%ft Working environment -10~+50,(95%RH No congelation) Dimension 95*41mm
SAFETY- SECURITY: Smoke alarms that are properly installed & maintained, play a vital role in reducing fire deaths and injuries. Smoke alarms save lives. If there is a fire in your home, smoke spreads fast and you need smoke alarms to give you time to get out. Having a working smoke alarm cuts the chances of dying in a reported fire in half. Almost two-thirds of home fire deaths resulted from fires in homes with no smoke alarms or no working smoke alarms. We create the best products in Fire Safety industry, just give us your requirements and we will provide you quote at best prices.
HS-DG812 Battery Powered Photoelectric Smoke Alarm with excellent stability and high-sensitivity. Our standard battery is 6F22, lithium battery is optional. Key Specifications/Special Features Power Source: 9V Battery (included). Audio Alarm: 85dB/3m Temperature Range: 0 to 40 Humidity Range: 5%-95% relative humidity(RH) Sensor: Photoelectric Size: diameter 106mm in diameter x32mm depth Interconnects: No Easy to install with mounting base included Suitable for any room Low battery signal Test button for simple testing
"Instant Test Button,Dual sensor,Low battery warning Operating voltage: 9V battery Fixed Temperature alarm:57 Alarm indication: red LED flash Sound level: â?¥85dB/m Smoke Alarm Point:2.06%/ft Detecting area: 20 square meters Alarm output: sound and flash alarm "
"Test Button; Hush button Auto reset ASIC adopted;Anti-light, mothproof;Strong adaptability for circumstance; SMT design, high stability Technical specification: Operating voltage: 9V battery Alarm output: sound and flash alarm Sound level: 85dB/3 meters Sensitivity:2.06%/ft Detecting area: 20 square meters Dimension: 128*38mm Execute criterion:EN14604,UL217"
2 or 4 wire models * Dual LEDs for 360�‹visibility * Advanced detection and discrimination algorithms * Easy installation and maintenance * Sleek low-profile housing design * Durable sensor head, no need for replacement * SMD circuit board design-satisfactory quality and reliability guaranteed * Integrated heat detector for NB326-H-2 and NB326-H-4 models * N/C (normal/close)-N/O (normal/open)selectable relay output * AR (Auto Reset) function for security systems (optional for 4 wire models) * Sensor base option: standard and Shottky Diode.
Smoke detector ox-8 Remote control 12 metres Operation voltage-10ÿ30 v Economy mode consumption current-0, 1 ma Normal mode consumption current-0, 25 ma Alarm mode consumption current up to-20 ma Smoke sensitive range-0, 05ÿ0, 2 db/m Models with possibility setting by user (ir transmitter) Sensibility value-0, 05;0, 10;0, 15 db/m Visual check-out of function ability for smoke channel The response time of temperature canal depends on speed of temperature alternation and meets with en-54-7 Operation temperature range-minus 25up to+70 Dimensionns 100x54 mm Weight & 0, 17 kg
Main Feature: reset after power disconnection infrared photoelectric sensor network output / LED indicator stainless steel shield for anti-EMI SMT adopted Strong adaptability to circumstance Dustproof, mothproof, anti-white light Technology parameter: Operating voltage: DC12V Standby current: 2mA Alarm current: 10mA Operating temp.: -10-50 Working humidity: 95%RH Alarm mode: network output / LED indicator Detecting area: 20 square meter Sensitivity: class I Alarm output: relay output (N.C.)
1. Easy installation and maintenance 2. Light Labyrinth with High stability & High accuracy 3. High adaptability to the ambient, with dustproof, mothproof, moisture proof and anti-white light function 4. This is 4 wire type 5. DC 9-35V wide voltage operating a range 6.Low standby current 7. Power supply non-polarized input 8. Twin LED for 360 degrees visual 9. Flashing LED power indicator 10. The alarm output is relay output 11. Metal shield, anti-electromagnetic interference 12. Two-year limited warranty 13. Suit for detecting the smoke in the house, shop, hotel, restaurant, office building, school, etc...
48VDC Wired Smoke detector is a safety device to detect smoke, and prevent fire. When it detects smoke, the detector sent a relay signal to fire alarm system to remind with LED lit on. It used for Telecom or Mobile's machine room or computer room of factory or electric power. Features: * 4 wire interconnection * 48V DC powered * Frosting plastic * High sensitivity * To Set NC or NO Description: * Working voltage: DC48V * Static current::
We have available following Ship Spares for sell. Product Description: Product Name-Optical Smoke Detector Maker-Tyco Model-601P-M Part No-1709 Country of Origin-United Kingdom
Features  � High stability optical chamber � Circular LED indicator for 360° visibility � Network by current, NONC optional � Adapts CMOS with low power consumption � High adaptability to the ambient with dustproof, mothproof,  moistureproof, anti-white light and high EMI immunity � Input voltage: 10-35V DC � Orientation differences: