Handheld ultrasonic flow meter Installation method: Handheld SD card high memory data logging, maximum memorize 512 days data. Flow range: +/-0.03 ft/s ~ +/-40 ft/s (+/-0.01 m/s~ +/-12 m/s) Accuracy: +/-0.5% of measured value Repeatability: 0.15% Output: 4-20mA Internal lithium power supply: 10hours Pipe size range: 0.6â?³~240â?³(15mm~6000mm) Transducer: IP54, CP magnet portable transducer, 5m cable
Anti-allergic Ultrasonic seam Soft nose Barrett Latex and fiberglass free Single use only Packing: 50 pcs/box, 2.000 pcs/carton 3-PLY DISPOSABLE FACE MASK STRUCTURE 1st Layer: Water-repelling, non-woven fabric. Prevents droplet and spray penetration. 2nd Layer: Electrostatic-induced melt-blown polypropylene, blocks dust and microbes (>99%). 3rd Layer: Fine bicomponent (PP/PE) fabric, absorbs moisture and provides soft and non-sticky feel.
Iv cannulas, syringes, infusion set, rapid malaria test, rapid typhoid test, bp machine, thermometer, latex foley catheter, surgical gown, ppe kit, latex gloves, vaucum drying oven, fume hood (ms/ss), ducted pp fume hood, biological safety cabinet(as per class 2nd), air shower, pass box, bod incubator, incubator shaker, mini dry bath incubator, electronic burette, co2 incubator, seed germinator refrigerated, ceramic magnetic stirrer hot plate, ultrasonic cleaner, autoclave vertical/horizontal, ice flake machine, tube furnace, elisa reader/microplate reader, microplate washer, ultrasonic homogenizer, deep freezer ( 10 c to 40 c), water baths, ph meter, flammable cabinet, heating mental, table top autoclave class b series, semi auto chemistry analyzer, pcr machine, refrigerated chiller, nucleic acid extraction system, mb 6900 plus, mb 1660, mb 2000, mb 2100, high speed table top refrigerated centrifuge, laboratory furniture, lab equipments and devices, herbal extracts, extracts etc..
Ultrasonic Quilt With Poly Microfiber Fabric
Ultrasonic Quilt With Poly Microfiber Fabric
Ultrasonic Quilt With Poly Microfiber Fabric
Ultrasonic Quilt With Poly Microfiber Fabric
Ultrasonic Quilt With Poly Microfiber Fabric
Ultrasonic Quilt With Poly Microfiber Fabric
US$ 2.65 - 5.55 / Piece Get Freight Cost Calculate Margin 10000 Pieces Minimum Order 3 - 30 days Lead Time Product Details Model Number : S M L---#6173 Brand Name : WinHealth Origin : China (mainland) Small Orders : Accepted Key Specifications/Special Features: Surgical gown MATERIAL: SMS ,SMMS , SSMMS , Spunlace Characteristic : Antistatic , anti-blood, water resistant , alcohol resistant Gram weight :30-70g/ Style : with knitted cuff, hook and loo[ fatener Four waist belts with card , book folding Production process : Ultrasonic , double stitch Three line /four line /five lie overlock sewing Size:S,M,L,XL,XXL,XXXL Package:1pc/sterile pouch , , 50pcs /ctn Usage field :suitable for hospital /medical and biological research institution, surgical gown can protect the medical workers from being infected by the blood /body fluid and other infectious material Shipping Information: FOB Port: China (Mainland) Lead Time : 3 - 30 days Dimensions per Unit : 120 X 80 X 35 Centimeters Weight per Unit : 100 Grams Units per Export Carton: 50 Export Carton Dimensions L/W/H : 585 X 450 X 420 Centimeters Export Carton Weight : 11 Kilograms
Re:Velvet ultrasonic quilt We are producing various kind of bedding items We would like to supply our products to you. Please make an enquiry for specific needs for further progress. We will make a nice busness with you. We look forward to hear from you . Thank you Best regards Shim
[ CHARACTERISTICS ] ¶Wide Beam Transducer (Broadband ultrasonic measurement function) ?¢ Determine the transmission frequency by finding the resonance frequency of the pipe according to the outer diameter, material, and thickness of the pipe â?¢ Little error occurs due to stable signal reception â?¢ Excellent measurement stability even when there are air bubbles slurry (30% or less), scale generation, changing temperature and density. How to install â?¶Pipe Configuration (automatic correction of disturbance factors) â?¢ In actual industrial sites, sufficient straight pipe without interference is required for accurate flow measurement â?¢ If no sufficient straight pipe is secured ; * HUF 2000N / HUF 2000DN (Compensation Type Ultrasonic Flow Meter) - Re estimation of correction factors for disturbance factors and distances from disturbance factors, self compensation. - It has the same accuracy as that in which a sufficient intuition is secured even at a short distance from the disturbance factor. â?¶Other Functions * Diagnostic Menu (Self diagnosis function) The attenuation degree, correlation degree, and noise degree of the ultrasonic received signal can be known and quantified to display empty pipe information, strength of the received signal, bubble content, S/N ratio, etc. * Auto Zero (Automatic zero adjustment function) In the first installation, zero point can be automatically adjusted without stopping the flow. Periodic automatic zeroing can prevent zero deformation caused by other factors. * MultiPulse Transmission (Multi pulse function) The pulse signal to analyze the time difference waveform transmit 50 pulse signals per measurement cycle, thus it has excellent measurement sensitivity and stability of ultrasonic signals. * Liquid Class Menu (Fluid selection function) A list of about 30 types of fluids is provided. When selecting fluids, the expected ultrasonic velocity (m / s), viscosity ( cS ), density (SG), and data are automatically entered and the pipe temperature range can be selected. Pipe Data Menu (Pipe selection function With more than 40 types of standard pipes and custom pipes built in, you can enter pipe outer diameter, material, and thickness using a list of pipe class and size options.
All material meets ASTM or AMS specifications with ultrasonic testing as required Test certificates are maintained to ensure full material traceabilityWaterjet cut parts for special shapes can be provided with close tolerances and minimal distortion Applicationsmarkets Aerospace Commercial Transportation Building amp Construction Infrastructure Electrical Renewable Energy Mass Transportation Grades 2024 amp 7075
All material meets ASTM or AMS specifications with ultrasonic testing as required Test certificates are maintained to ensure full material traceability Waterjet cut parts for special shapes can be provided with close tolerances and minimal distortion Grades 1100 2024 2124 3003 5052 5083 5086 6013 6061 7050 7075 7475 ProductAluminium sheet plates coil BrandRenaissance Pipe Fitting Inc SizesRefer the specification ConditionNew Rating44 based on 45 reviews priceStart from 50 USD
SL1168 Ultrasonic Flowmeter Specifications: Accuracy: +/-1.0% of reading from 0.03 to 16fts (0.01 to 5m/s) Repeatability: +/-0.3% of reading Wide turndown ratio Bi-directional flow range of 0.03 to 16 ft/s (0.01 to 5m/s) Pipe sizes from 1 to 48 inches (25 to 1200mm) Process pipe-wall temperature: 32 to140 (0 to 60) Power supply: 10 to 24 V AC or 10 to 36 V DC at 1A Output signals: 4-20mA Pulse (configurable) Relay (configurable) Digital communications: RS-232, RS-485, Modbus RTU
Accuracy & repeatability · Accuracy: +/-0.5% of reading from 0.03ft/s to 40ft/s (0.01 to 12m/s) · Repeatability: +/-0.15% of reading Description · Transit-time ultrasonic · Clamp on transducer and insertion transducer versions · High accuracy at low and high flows · Bi-directional flow · Clear, user-friendly menu selections Fluids measured · Water and liquids, tolerant of liquids with small amounts of air bubbles or suspended solids Flow range · Bi-directional flow range of 0.03ft/s to 40ft/s (0.01 to 12 m/s) Pipe sizes from 1 to 200 inches (25 to 5000mm) Digital communications · RS-485, Modbus RTU SD card · Standard SD card · Max record: 512 days · Record time interval Outputs · OTC pulse output :0~9999 Hz · Analog output : 4~20mA · Max load 750Ω Temperature · Transmitter: -40-140F (-40-60C) · Transducer: -40-176F (-40-80C)
Accuracy & repeatability Accuracy: +/- 1.0% of reading from 0.03ft/s to 40ft/s (0.01 to 12m/s) Repeatability: +/- 0.3% of reading Description ·Transit-time ultrasonic ·Handheld, easy to carry ·Clamp-on outside of pipe for easy set up ·No pipe cutting or process shutdown ·High accuracy at low and high flows ·Bi-directional flow Fluids measured Water and liquids; Tolerant of liquids with small amounts of air bubbles or suspended solids Flow range Bi-directional flow range of 0.03 ft/s to 40 ft/s (0.01 to 12 m/s) Pipe sizes from 1 to 48 inches (25 to 1200mm) Pipe material Carbon sheet ; stainless sheet ; PVC Digital communications RS-485, Modbus RTU Out puts OTC pulse output :0~5000 Hz Analog output : 4~20m A , max load 750Ω Temperature Transmitter: 14F~122F(-10C~50C) Transducer: 32F~176F(0C~80C)
SL1168 Ultrasonic Flowmeter Flow range: 0-40ft/s,o--40ft/s Accuracy: 1.0% of measurement value Repeatability:0.3% Pipe size: 1 in to 48 in Fluid: water Pipe material: carbon steel, stainless steel, pvc, copper, etc Communication interface: RS232, RS485.
- Material: ASTM B337, ASTM B338 Gr 1, Gr 2, Gr 3, Gr 7, Gr 9, Gr 12, Gr 16; - Technical: Seamless; - Process: Cold Rolled, Annealed or CWSR; - Grade: Gr.1 (CP titanium, low oxygen), Gr.2 (CP titanium, standard oxygen), Gr.7 ( Ti-Pa, standard oxygen), Gr.9 (Ti-3Al-2.5V), Gr.11 ( Ti-Pa, low oxygen), Gr.12 (Ti-Mo-Ni), Gr.16 (Ti-Pa,standard oxygen), Gr.17 (Ti-Pa,low oxygen) - Diameter: OD 6.0-273 mm, Wall thickness 0.3-22 mm, Length Within 18000 mm or Customized; - Application: Heat exchangers and condensers, Corrosive fluid transmission pipeline system, Titanium bicycle tube, automobile exhaust pipe,Offshore aquaculture; - Features: Light weight, excellent corrosion resistivity, strongly heat-resistance, high strength. - Inspection: Ultrasonic testing, Hydrostatic testing, Flattening testing, visual surface inspection, Dimensional inspection, tensile properties inspection and Chemical elements analysis.