Manufacturer:Panasonic Product category:Low signal relays - pcb Rohs:Rohs compliant by exemption compliant Brand:Panasonic industrial devices Product:Low profile relays Type:Miniature Contact form:Dpdt (2 form c) Contact current rating:3 a Coil voltage:5 v Maximum switching current:2 a Coil current:40 ma Coil type:Non-latching Power consumption:200 mw Contact rating:3 a Contact termination:Solder pin Mounting style:Through hole Packaging:Tube Factory pack quantity:50 Search:
ECG cables also referred to as an ECG patient cable, is a type of cable connection designed for non-invasive heart monitoring, typically used to help diagnose potential heart issues. The ECG cable connects to electrodes which are positioned at specific locations on the patientâ??s body to detect and record heart muscle electrical activity. The cables then transmit the electrical activity back to the ECG device for analysis and diagnosis by medical professionals. ECG Cable Feature [Multiple Leads]: ECG cables usually have several leads placed in specific areas on the patientâ??s body, such as the chest, arms, and legs, to measure the heartâ??s electrical activity from different angles. [Durability]: ECG cables are constructed from top-quality, sturdy materials that can endure repeated bending, tugging, and twisting without sustaining any damage. This ensures that the cables can withstand the rigors of frequent use and remain reliable over time. [Shielding]: ECG cables are shielded to block out external electrical signals, which can interfere with the accuracy of the readings. [Connector Compatibility]: The ECG cables are available with various connector types, including snap, clip, and banana, to fit different types of ECG machines. [Safety]: ECG cables are designed to meet strict safety standards and regulations to ensure patient safety. This helps to ensure that patients are protected from any potential harm during the monitoring process. [Cleaning and Disinfecting]: The ECG cables are easy to clean and disinfect to maintain hygienic conditions, as they come into contact with the patientâ??s skin. ECG Cable Advantages [Excellent Performance]: ECG cables are built to withstand the rigors of twisting and bending, and have been thoroughly tested to ensure optimal performance. The cables are also equipped with electrical shielding to protect the signal integrity, ensuring accurate readings. [Non-Invasive]: ECG cables are non-invasive, which means that they do not require any incisions or invasive procedures. This reduces the risk of infection and makes the monitoring process much safer for patients. Instead, the cables are simply attached to the patient's skin, making it a quick and painless process.
ALSTOM GBCDG61EG040SGCH IDMT TWO O/C & ONE E/F RELAY WITH HIGH-S Relay Technical specification Relay model no CDG61EG040SGCH Relay type CDG 61 Case size 3D HOR. Application 2 O/C & 1 E/F Current setting - O/C 2.5 to 10 amps Aux.Contacts With Flag 3M S/R Output contacts 2M S/R C.T.Secondary 5 amps Frequency 50 Hz Burden 3 VA Operating time 1.3 secs Current setting - E/F 0.5 to 2 amps High set - O/C Setting 20 to 80 amps High set - E/F Setting 5 to 20 amps High set conts.With flag CAG 13 / 2M S/R Name plate RFG9125 903 Outline drawing MFJ 014 Wiring diagram MADZ 821.27-1
ALSTOM GBCDG61EG041SGCH IDMT TWO O/C & ONE E/F RELAY WITH HIGH-S Technical specification Relay model no CDG61EG041SGCH Relay type CDG 61 Case size 3D H 30T Application 2 O/C & 1 E/F Current setting - O/C 2.5 to 10 amps Contacts / Output contacts 3M S/R / 2M S/R C.T.Secondary 5 amps Frequency 50 Hz Burden 3 VA Operating time 3 secs Current setting - E/F 0.5 to 2 amps High set - O/C Setting 20 to 80 amps High set - E/F Setting 5 to 20 amps High set CAG 13 Name plate RFG9126 903 Outline drawing MFJ 014 Wiring diagram MADZ 821.27-1
Manufacturer:Panasonic Product category:Low signal relays - pcb Rohs:Rohs compliant by exemption compliant Brand:Panasonic industrial devices Product:Slim form relays Contact form:Dpdt (2 form c) Contact current rating:1 a Coil voltage:24 v Maximum switching current:1 a Coil current:9.6 ma Coil type:Non-latching Power consumption:230 mw Contact rating:1 a at 30 vdc / 300 ma at 125 vac Contact termination:Solder pin Mounting style:Through hole Packaging:Tube Factory pack quantity:50 Search:
* 10 A switching capability * subminiature, standard PCB layout * 1 Form A and 1 form C configurations * plastic sealed and flux proofed types available * contact arrangement 1H 1Z * Max. switching current 10A * Max. switching voltage 250VAC/30 VDC * insulation resistance 100m Ω
* outline dimension 18.4*10.2*15.3 * 10A switching capability * 1 Form A and 1 Form C configurations * standard PCB layout * Plastic sealed and flux proofed types available * contact arrangement 1H 1Z * Max. switching current 3A 10A * Max. switching voltage 250VDC/ 30VDC * insulation resistance 1000 Ω
* outline dimension 32.2*27.5*19.8 * 30A switching capability *UL insulation systemï¼? Class F *PCB layout , contact QC layout * Has a set of normally open, normally closed, switch contact form * plastic sealed and dust protected types available * contact arrangement 1A 1B 1C * Max. switching current 30A 15A 20A * Max. switching voltage 277VAC/ 30VDC
Manufacturer:Panasonic Product category:Low signal relays - pcb Rohs:Rohs compliant by exemption Brand:Panasonic industrial devices Product:Slim form relays Contact form:Dpdt (2 form c) Contact current rating:1 a Coil voltage:12 v Maximum switching current:1 a Coil current:11.7 ma Coil type:Non-latching Power consumption:140 mw Contact rating:1 a at 30 vdc / 300 ma at 125 vac Contact termination:Solder pin Mounting style:Through hole Packaging:Tube Factory pack quantity:50 Search:
Features: Small size, light weight. Low price reliable quality. Pc board mounting. Suitable for household electrical appliance, automation system, electronic equipment, instrument, meter, telecommunication facilities and remote control facilities.
GBCDG61EG046SGCH IDMT TWO O/C & ONE E/F RELAY WITH HIGH-S Technical specification Relay model no - CDG61EG046SGCH Relay type - CDG 61 Case size - 3D H 30T Application - 2 O/C & 1 E/F Current setting O/C- 2.5 to 10 amps Contacts / Output contacts 3M S/R / 2M S/R C.T.Secondary - 5 amps Frequency - 50 Hz Burden - 3 VA Operating time - 3 secs Current setting - E/F - 1 to 4 amps High set - O/C Setting- 25 to 100 amps High set - E/F Setting- 10 to 40 amps High set - CAG 13 Name plate - RFG9126 904 Outline drawing - MFJ 014 Wiring diagram - MADZ 821.27-1
GBCDG61EG042SHCH IDMT 2 O/C & 1 E/F RELAY WITH HIGH SET Technical specification Relay model no- CDG61EG042SHCH Relay type - CDG 61 Case size - 3D H 30T Application - 2 O/C & 1 E/F Current setting - O/C - 0.5 to 2 amps Contacts - 2M2B H/R 2M S/R Output contacts - 2M2B H/R 2M S/R C.T.Secondary - 1 amps Frequency - 50 Hz Burden - 3 VA Operating time - 3 secs Current setting - E/F - 0.2 to 0.8 amps High set - O/C Setting- 4 to 16 amps High set - E/F Setting - 1 to 4 amps High set - CAG 13 Name plate - RFG9126 902 Outline drawing - MFJ 014 Wiring diagram - MADZ 821.29-1
GBCDG61EG054SGCH IDMT 3 O/C OR 2O/C& 1 E/F RELAY WITH HI Technical specification Relay model no - CDG61EG054SGCH Relay type - CDG 61 Case size - 3D H 30T Application - 2 O/C & 1 E/F Current setting - O/C - 0.5 to 2 amps Contacts - 3 N/O S/R Output contacts - 2 N/O S/R C.T.Secondary - 1 amps Frequency - 50 Hz Burden / Operating time - 3 VA / 1.3 secs Current setting - E/F 0.2 to 0.8 amps High set - O/C setting 4 to 16 amps High set - E/F setting 2 to 8 amps High set CAG 13 Name plate RFG9125 902 Outline drawing MFJ 014 Wiring diagram - MADZ 821.27-1
GBCDG61EG057SGCH IDMT 3 O/C OR 2O/C& 1 E/F RELAY WITH HI Technical specification Relay model no - CDG61EG057SGCH Relay type - CDG 61 Case size - 3D HOR. Application - 2 O/C & 1 E/F Current setting - O/C 0.5 to 2 amps Contacts 3 N/O S/R Output contacts 2 N/O S/R C.T.Secondary 1 amps Frequency 50 Hz Burden / Operating time 3 VA / 3 secs Current setting - E/F 0.2 to 0.8 amps High set - O/C setting 4 to 16 amps High set - E/F setting 1 to 4 amps High set CAG 13 Name plate RFG9126 902 Outline drawing MFJ 014 Wiring diagram MADZ 821.27-1
GBCDG61EG044SHCH IDMT 3 O/C RELAY WITH HIGH SET CAG 13 Technical specification Relay model no - CDG61EG044SHCH Relay type - CDG 61 Case size - 3D H 30T Application - 3 O/C Current setting - 0.5 to 2 amps Contacts / Output contacts - 2 N/O 2 N/C H/R C.T.Secondary - 1 amps Frequency - 50 Hz Burden - 3 VA Operating time - 3 secs High set - O/C Setting - 4 to 16 amps High set - CAG 13 High set contacts - 2 N/O S/R Name plate - RFG9126 771 Outline drawing - MFJ 014 Wiring diagram - MADZ 821.29-1
GBCDG61EG058SGCH IDMT 3 O/C OR 2O/C& 1 E/F RELAY WITH HI Technical specification Relay model no - CDG61EG058SGCH Relay type CDG 61 Case size - 3D H 30T Application - 2 O/C & 1 E/F Current setting - O/C - 2.5 to 10 amps Contacts - 3 N/O S/R Output contacts - 2 N/O S/R C.T.Secondary - 5 amps Frequency - 50 Hz Burden / Taps - 3 VA / Std Operating time - 1.3 Secs Current setting - E/F - 0.5 to 2 amps High set - O/C Setting - 25 to 100 amps High set - E/F Setting - 10 to 40 amps High set / High set cont. - CAG 13 / 2 N/O S/R Name plate - RFG9125 903 Outline drawing - MFJ 014 Wiring diagram - MADZ 821.27-1
GBCDG61EG101ZRCH IDMT 3 O/C OR 2O/C& 1 E/F RELAY WITH HI Technical Specification Model No - CDG61EG101ZRCH Relay Type - CDG61/CAG17(MRK-III) Application - 2 O/C + 1 E/F Case Size - 3D Horz C.T. Secondary - 5 Amp C.T. O/C Setting - 2.5 - 10 Amps. E/F Setting - 0.5 - 2 Amps Contacts - 2 N/O S/R Flag - Yes Frequency - 50 Hz Burden / D.M.T - 3 Va / 3 Sec High Set Type / Conts. - CAG17 / 2 N/O S/R Highset O/C Setting - 12.5 - 100 Amps. HighSet E/F Setting - 5 - 40 Amps Mounting - Flush Name Plate - RFG9126 903 Outline Diagram - MFJ 014 Wiring Diagram - MADZ821.31
Gbcdg61eg101zmch Idmt 3 O/c or 2o/c& 1 E/f Relay With Hi Model No : Cdg61eg101zm(M) Cdg61/cag17(Mrk-iii) Application - 3 O/c Burden / D.m.t - 3 Va / 3 Sec. C.t. Secondary - 5 Amp C.t. Case Size - 3d Horz. Contacts (S/r or H/r) - 2 N/o S/r Flag - Yes Frequency - 50 Hz High Set Type - Cag17 Highset Contacts - 2m S/r Highset O/c Setting - 12.5 - 100 Amps. Mounting - Flush O/c Setting - 2.5 - 10 Amps. Name Plate - Rfg9126 774 Outline Diagram - Mfj 014 Wiring Diagram - Madz821.31
GBCDG61EG102ZMCH IDMT 3 O/C OR 2O/C& 1 E/F RELAY WITH HI Model No : CDG61EG102ZMCH CDG61/CAG17(MRK-III) APPLICATION - 3 O/C BURDEN - 3 VA C.T. SECONDARY - 1 AMP CT. CASE SIZE - 3D HORZ. CONTACTS (S/R OR H/R) - 2 N/O S/R D.M.T - 3 SEC. FLAG - YES FREQUENCY - 50 HZ HIGH SET TYPE - CAG17 HIGHSET CONTACTS - 2M S/R HIGHSET O/C SETTING - 2.5 - 20 Amps. MOUNTING - FLUSH O/C SETTING - 0.5 - 2 Amps. Name Plate RFG9126 771 Outline drawing MFJ 014 Wiring Diagram MADZ821.31
Gbcdg61eg101znch Idmt 3 O/c or 2o/c& 1 E/f Relay With Hi Model No : Cdg61eg101zn(M) Cdg61/cag17(Mrk-iii) Application - 3 O/c Burden / D.m.t - 3 Va / 3 Sec. C.t. Secondary - 5 Amp C.t. Case Size - 3d Horz. Contacts (S/r or H/r) - 2 N/o 2 N/c H/r Flag - Yes Frequency - 50 Hz High Set Type - Cag17 Highset Contacts - 2m S/r Highset O/c Setting - 12.5 - 100 Amps. Mounting - Flush O/c or O/v Setting - 2.5 - 10 Amps. Name Plate Rfg9126 774 Outline Diagram Mfj 014 Wiring Diagram Madz821.32