T1000 primary injection test set is the model featured with light weight and 2 minutes output time at 1000A. This ideal primary injection test set with LCD display,quick control button and rotating mouse is very easy and convenient to operate. Features 2 minutes continuous output at 1000A Flexible control over output, such as manual, ramp, etc Independent Aux DC supply In-built multi-meter facility Typical CT testing functions are also included Weight : 30kg
T1000 primary injection test set is the model featured with light weight and 2 minutes output time at 1000a. This ideal primary injection test set with lcd display, quick control button and rotating mouse is very easy and convenient to operate. Features 2 minutes continuous output at 1000a Flexible control over output, such as manual, ramp, etc Independent aux dc supply In-built multi-meter facility Typical ct testing functions are also included Weight : 30kg
T1000 primary injection test set is the model featured with light weight and 2 minutes output time at 1000A. This ideal primary injection test set with LCD display,quick control button and rotating mouse is very easy and convenient to operate. Features 2 minutes continuous output at 1000A Flexible control over output, such as manual, ramp, etc Independent Aux DC supply In-built multi-meter facility Typical CT testing functions are also included Weight : 30kg
Features Permanent current up to 1000 A, 5KVA Max current output up to 1100A. Built-in digital ammeter 0.5% accuracy. Built-in digital timer resolution 1 ms (Optional). Made up of two units, control and power unit Thermal and short-circuit protection. With 6m length 1000A heavy current test cable With contact Applications TEST-901 primary current injection test set adopts ARM Chip to control its output process and large capacity of toroidal transformers. It is equipped with LCD display and current meter; it can show primary current value, second current value, turn ratio and the action time. Packing is used as aluminum alloy body with PC panel. TEST-901 is mainly applied to CT turn ratio testing in the power system and contact resistance test which need large current. Circuit Breaker Test Current Transformer Test Resistance Test Power Transformer Test Primary current injection test TEST-901 primary current injection test system is a necessary equipment in all walks of life in electrical commissioning needs large current place, used in power plants, substations, electrical manufacturers and scientific research, laboratory and other units, belonging to short-term or intermittent working system, It has a small size, light weight, good performance, easy to use and maintenance features.
TEST-200 200A primary current injection test kit adopts ARM Chip to control its output process and large capacity of toroidal transformers. It is equipped with current meter; it can show primary current value, second current value, the action time and voltage value. Packing is used as aluminum alloy body with PC panel. LCD screen display single-phase protective relay test device of voltage and current output stopwatch; a full isolation, adjustable AC and DC voltage, AC direct current; an adjustable DC voltage and an adjustable AC voltage; output circuit with double overload protection, high output capacity, small size, light weight, high reliability. PARAMETERS Electrical parameters Accuracy ±0.5% Power Supply(AC) 220V±10%·2000VA, 50Hz/60Hz or 110V±10%2000VA, 50Hz/60Hz Current Output (AC) 200A5V or 100A10V Capacity 2KVA The current output waveform distortion 5% Dual protection overload electronic protection and software protection Primary current Range 0-250A Resolution 0.1A Accuracy
TEST-903 primary current injection test kit adopts ARM chip to control the output process and large capacity of toroidal transformer. It is equipped with LCD screen display current meter, also showed primary current value, secondary current value, turn ratio and the phase shift. Aluminum alloy body with PC panel component the shell. TEST-903 is mainly applied to test CT turn ratio and polarity in the power system, the contact resistance, high voltage circuit breaker protection test and high voltage generator test etc, which need large current on-site or in the lab.
TEST-901 primary current injection test set adopts ARM Chip to control its output process and large capacity of toroidal transformers. It is equipped with LCD display and current meter; it can show primary current value, second current value, turn ratio and the action time. Packing is used as aluminum alloy body with PC panel. TEST-901 is mainly applied to CT turn ratio testing in the power system and contact resistance test which need large current.
For in vitro qualitative detect of Covid-19 antigen in nasal(NS) swab specimens directly from individuals who are suspected of COVID-19 by their healthcare provider within the first 5 days of the onset of the symptoms. This test is only provided for use by clinical laboratories or to healthcare workers for point-of-care testing, and not for at home testing. 1.Easy to collect samples simple operation without professional equipment. 2.The test results are available in 15 minutes, and the test results are clearly visible. 3.Convenient transportation and low price, higher accuracy. 4.Suitable for large-scale rapid screening. Shelf life: 24 Months Test Result time: 10 Mins Packing: 25 Pieces per Box