OXYTEK 5 LT CAPACITY OXYGEN (O2) CONCENTRATOR STARTING FROM 335 USD, LOWERS DEPENDING ON QUANTITY ORDERED. TECHNICAL SPECIFICATIONS: K5BW Device's Electric Senif Class II, Type BF Weight 16KG Dimensions 305 x 300 x 535 (Length Width Height) mm Working Type Continuous Flow adjustment button 0-5 LPM Oxygen concentration 931% 3% (0-5LPM) Oxygen concentration sensor's alarm 82% or less Maximum output power (to sdg Average sound level 45dB (A) Power supply 230VAC-50HZ Operating Temperature / Humidity Range and Oxygen Concentration below flow rate CONCENTRATION 96% -06%
580g Disposable Cream Charger Cylinder * Filled with pure Nitrous Oxide N2O * 580g of Nitrous oxide (E942 food grade) * Each cylinder is individually weighed electronically with filling weight * Produced with high graded recyclable rustproof cast iron * 580g of Nitrous oxide (E942 food grade) * Fully disposable and recyclable * Meets all European laws and regulations * Pressure tested at 165 bar * Only use approved cream dispensers (30 bar)
Nitrile gloves, oxygen generator, syringes, energy drinks, soft drinks, wholesale cosmetic, perfume, frozen chicken, frozen pork .
OXYGEN CYLINDERS 150 Bar, Valve: GF-6A, Certificate: ISO9001/ISO13485.
Accu-Chek test strips are essential components of blood glucose monitoring for individuals with diabetes. These strips are designed to work seamlessly with Accu-Chek blood glucose meters, enabling accurate and reliable measurement of blood sugar levels. The strips utilize advanced technology to require only a small blood sample, making the testing process more comfortable. With rapid and precise results, Accu-Chek test strips empower users to effectively manage their diabetes by providing valuable insights into their current glucose levels. This user-friendly and indispensable tool plays a crucial role in facilitating proactive health management for individuals living with diabetes.
Flow: 1-5LPLM Purity: 93% Power: 320VA Input: 220V 50HZ Noise: 45dB Weight: 13.5kgs Sizez;33.5*33*48cm Basic function; Pressure alarm, power offer alarm, timing, abnormal voltage alarm, Optional: nebulizer , purity alarm, remote control
Flow: 1-5LPLM Purity: 3L @93% , 5L @70% Power: 320VA Input: 220V 50HZ Noise: 50dB Weight: 21kgs Sizez;38*32.5*59cm Basic function; Pressure alarm, power offer alarm, timing, abnormal voltage alarm, Optional: nebulizer , purity alarm, remote control
Flow: 1-5LPLM Purity: 3L @93% , 5L @70% Power: 290VA Input: 220V 50HZ Noise: 48dB Weight: 18kgs Sizez;41*28*51cm 1. Atomization build-in 2. Large oxygen flow supply meet daily demand 3. Multiple filter protection for oxygen safety 4. Imported oil-free compressor with USA technology 5. French imported molecular sieve with high effeciency 6. Smart self-diagnostic with multiple alarm system
Flow: 1-5LPLM Purity: 5L @93% Power: 300VA Input: 220V 50HZ Noise: 51dB Weight: 19kgs Sizez;41*28*51cm 1. Atomization build-in 2. Large oxygen flow supply to meet daily demand 3. Multiple filter protection for oxygen safety 4. Imported oil-free compressor with USA technology 5. French imported molecular sieve 6. Smart self-diagnostic with multiple alarm system
This product is from China. Many variants. Please email or call to get the best deals & prices.
Flow: 1LPLM Purity: 1L @93% Input: 220V 50HZ Power: 150VA Noise: â?¤40dB Weight: 7.2kgs Size:34*20.2*39cm 1. Simple and fashion 2. Silent and comfortable 3. Compact and light 4. French imported molecular sieve 5. Real-tiem oxygen purity display 6.Build-in atomization function 7. Intelligent alarm system Oxygen concentrator
Max. Flow: Approx 3+/-1.5L/min (standard atmospheric pressure) Oxygen density:29%+/-2% (standard atmospheric pressure) Size: 230(L)*110(W)*160(H)mm Weight: Generating unit+ adapter 2.00KG AC100V-240V(according to/DC12V-16.8V(direct) adapter) Power Consumption: average below 32W Noise: below 48dB
Flow: 1-5LPLM Purity: 3L @93% , 5L @70% Power: 320VA Input: 220V 50HZ Noise: 45dB Weight: 13.5kgs Sizez;33.5*33*48cm Basic function; Pressure alarm, power offer alarm, timing, abnormal voltage alarm, Optional: nebulizer , purity alarm, remote control
Flow: 1-10LPLM Purity: 93% Power: 750VA Input: 220V 50HZ Noise: 52dB Weight: 24kgs Sizez;39*32.5*59cm Basic function; Pressure alarm, power offer alarm, timing, abnormal voltage alarm, Optional: nebulizer , purity alarm, remote control
Flow: 1-8LPLM Purity: 93% Power: 750W Input: 220V 50HZ Noise: 52dB Weight: 23kgs Sizez;38*32.5*59cm Basic function; Pressure alarm, power offer alarm, timing, abnormal voltage alarm, Optional: nebulizer , purity alarm, remote control
>>24 hours continuously >>Four alarm systems: power off alarm, pressure circulation fault alarm and compressor fault alarm, oxygen purity alarm >> AVG oxygen purity: 93% >> Low sound level: less than 48dB (A) >> Net weight: 19.2kg >> Strong ABS shell: Anti-aging, deluxe design. >> 1 year warranty for main machine, 5 years for compressor. Oxygen flow:1 -8 LPM Oxygen purity: 93% ±3% Operating temp : 5 C--40 C Operation noise(dB): 48dB A Power Supply:AC 220V±22V, 50Hz or 110V±10V /60Hz Power Consumption:540 W Output pressure:58.6 ±6KPa Equip. Classification:Class II Type B Dimensions(L W H): 43 cm x 32 cm x 62 cm
Flow: 1-5LPLM Purity: 93% Power: 480VA Input: 220V 50HZ Noise: 45dB Weight: 13.5kgs Sizez;33.5*33*48cm Basic function; Pressure alarm, power offer alarm, timing, abnormal voltage alarm, Optional: nebulizer , purity alarm, remote control
The Haemonetics Cell Saver 5/5+ Bowl Kit with the product code 225M004C is a component of the Haemonetics Cell Saver 5 and Cell Saver 5+ autotransfusion systems. These systems are used in medical settings, particularly during surgeries, to collect, process, and reinfuse a patient's own blood that is lost during the procedure. Here are some general features and considerations related to the Haemonetics Cell Saver 5/5+ Bowl Kit: Autotransfusion System: The Haemonetics Cell Saver 5/5+ is an autotransfusion system designed for blood salvage during surgery. It helps minimize the need for allogeneic blood transfusions. Bowl Kit: The Bowl Kit is a critical component of the system, and it typically includes a collection bowl where blood is collected, processed, and washed before being returned to the patient. Compatibility: The Bowl Kit is designed to be compatible with the Cell Saver 5 and Cell Saver 5+ devices. Processing Blood: The autotransfusion system processes shed blood from the surgical field, removes unwanted materials, and returns the washed blood to the patient. 225M004C: The specific product code is used for identification and ordering purposes. It helps in ensuring that the correct component or kit is being used.
From as little as $1.00 FoB per test - including IFU in Language of your choice! COVID Rapid Test / Lateral Flow - SARS-CoV-2 Antigen Kit Self Test Kit - Nasal Swab based - Qualitative - IVD (Invitro diagnostic medical device) - Rapid immunochromatographic assay - 12 Minutes to result - Shelf Life 18 months - EU common list approved. - In use: BE, BG, CY, FR, RO, SI, ES - Validation Completed: - FR, DE, ES UK DHSC Approved. - Validation completed & In use - Specificity 100.0% - Sensitivity 93.0% Certifications: EU HSC Approved UK DHSC Approved (included in JRC database) CE Directive 98/79/EC EN ISO 13485:2016 BS EN 13612:2002 ISO 14971:2019 EN ISO 23640:2015 ISO 15223-1:2016 EN ISO 18113-1:2011 EN ISO 18113-4:2011 EN 62366-1:2015 More Information is available at our website. Please contact us directly, visit our website, follow us on LinkedIn and/or Instagram. @fiigureofficial in = fiigureofficial
Great for Kids. From as little as $1.00 FoB per test - including IFU in Language of your choice! COVID Rapid Test / Lateral Flow - SARS-CoV-2 Antigen Kit Self Test Kit - Saliva based - Lollipop Style - Qualitative - IVD (Invitro diagnostic medical device) - Rapid immunochromatographic assay - 15 Minutes test to result - Shelf Life 18 months - EU common list approved. - In use: BE, BG, CY, FR, RO, SI, ES - Validation Completed: - FR, DE, ES UK DHSC Approved. - Validation completed & In use - Specificity 100.0% - Sensitivity 93.0% Certifications: EU HSC Approved UK DHSC Approved (included in JRC database) CE Directive 98/79/EC EN ISO 13485:2016 BS EN 13612:2002 ISO 14971:2019 EN ISO 23640:2015 ISO 15223-1:2016 EN ISO 18113-1:2011 EN ISO 18113-4:2011 EN 62366-1:2015 More Information is available at our website. Please contact us directly, visit our website, follow us on LinkedIn and/or Instagram. @fiigureofficial in = fiigureofficial