Hand function position fixed splint (AJY-S09) It is used for the fixation of stable fractures of the hand and wrist, the fixation of neuromuscular and tendon injuries, and the fixation of functional positions after orthopaedic surgery. Prevent deformity caused by bone and joint disease in thumb-to-finger and palm-to-hand positions shape. 337*170*3.2mm LOW TEMPERATURE THERMOPLASTIC SHEET Product features: Low temperature thermoplastic sheet is a new type of material made of specially synthesized polymer polycaprolactone treated by a series of chemical methods. Molecules are in a stable state at room temperature (10-30C), and can be softened after being heated in 65-70C water for 1-3 minutes. Curing in 3-5 minutes at room temperature. It has the advantages of light weight, high strength, good air permeability, not afraid of water, non-toxic, odorless, non-irritating to the skin, etc., and has biodegradability. Scope of application: 1. Fixation after reduction of fractures and joint dislocations 2. Postoperative fixation of soft tissue injuries such as joint ligaments, nerve and tendon injuries 3. Bone, joint tuberculosis, acute and chronic osteomyelitis, septic arthritis, primary bone Fixation during conservative treatment such as tumor metastasis or after debridement 4. Joint deformity, nerve palsy, cerebral palsy, scoliosis correction and postoperative fixation in children and fixed 5. Fixation after burns and other plastic surgery operations 6. Production and application of rehabilitation braces and orthoses 7. Posture placement and fixation during radiotherapy
Hand rest position fixed splint (AJY-S08) It is used for fixation after orthopedic surgery such as hand and wrist fractures, nerve tendon injuries, scar contractures, etc., to prevent or correct the deformities caused by bone and joint, neuromuscular disease. 360*210*3.2mm LOW TEMPERATURE THERMOPLASTIC SHEET Product features: Low temperature thermoplastic sheet is a new type of material made of specially synthesized polymer polycaprolactone treated by a series of chemical methods. Molecules are in a stable state at room temperature (10-30C), and can be softened after being heated in 65-70C water for 1-3 minutes. Curing in 3-5 minutes at room temperature. It has the advantages of light weight, high strength, good air permeability, not afraid of water, non-toxic, odorless, non-irritating to the skin, etc., and has biodegradability. Scope of application: 1. Fixation after reduction of fractures and joint dislocations 2. Postoperative fixation of soft tissue injuries such as joint ligaments, nerve and tendon injuries 3. Bone, joint tuberculosis, acute and chronic osteomyelitis, septic arthritis, primary bone Fixation during conservative treatment such as tumor metastasis or after debridement 4. Joint deformity, nerve palsy, cerebral palsy, scoliosis correction and postoperative fixation in children and fixed 5. Fixation after burns and other plastic surgery operations 6. Production and application of rehabilitation braces and orthoses 7. Posture placement and fixation during radiotherapy
Thumb-fixed splint (Herringbone) AJY-S02 It is used for thumb metacarpal bone, acute metacarpal arthritis, thumb sprain, rheumatoid arthritis, post-tiger occidental occidental surgery and thumb function fixation after median nerve injury. 200*165*3.2mm LOW TEMPERATURE THERMOPLASTIC SHEET Product features: Low temperature thermoplastic sheet is a new type of material made of specially synthesized polymer polycaprolactone treated by a series of chemical methods. Molecules are in a stable state at room temperature (10-30C), and can be softened after being heated in 65-70C water for 1-3 minutes. Curing in 3-5 minutes at room temperature. It has the advantages of light weight, high strength, good air permeability, not afraid of water, non-toxic, odorless, non-irritating to the skin, etc., and has biodegradability. Scope of application: 1. Fixation after reduction of fractures and joint dislocations 2. Postoperative fixation of soft tissue injuries such as joint ligaments, nerve and tendon injuries 3. Bone, joint tuberculosis, acute and chronic osteomyelitis, septic arthritis, primary bone Fixation during conservative treatment such as tumor metastasis or after debridement 4. Joint deformity, nerve palsy, cerebral palsy, scoliosis correction and postoperative fixation in children and fixed 5. Fixation after burns and other plastic surgery operations 6. Production and application of rehabilitation braces and orthoses 7. Posture placement and fixation during radiotherapy
Elbow Joint Splint (AJY-S12) It is used for elbow joint fixation for tendon, soft tissue, and nerve injury in the elbow joint in time for postoperative fixation of the joint. 448*260*3.2mm LOW TEMPERATURE THERMOPLASTIC SHEET Product features: Low temperature thermoplastic sheet is a new type of material made of specially synthesized polymer polycaprolactone treated by a series of chemical methods. Molecules are in a stable state at room temperature (10-30C), and can be softened after being heated in 65-70C water for 1-3 minutes. Curing in 3-5 minutes at room temperature. It has the advantages of light weight, high strength, good air permeability, not afraid of water, non-toxic, odorless, non-irritating to the skin, etc., and has biodegradability. Scope of application: 1. Fixation after reduction of fractures and joint dislocations 2. Postoperative fixation of soft tissue injuries such as joint ligaments, nerve and tendon injuries 3. Bone, joint tuberculosis, acute and chronic osteomyelitis, septic arthritis, primary bone Fixation during conservative treatment such as tumor metastasis or after debridement 4. Joint deformity, nerve palsy, cerebral palsy, scoliosis correction and postoperative fixation in children and fixed 5. Fixation after burns and other plastic surgery operations 6. Production and application of rehabilitation braces and orthoses 7. Posture placement and fixation during radiotherapy
Achilles tendon dorsal splint (AJY-S11) It is used for dorsal fixation after Achilles tendon injury, topological fixation of supporting foot. 442*247*3.2mm LOW TEMPERATURE THERMOPLASTIC SHEET Product features: Low temperature thermoplastic sheet is a new type of material made of specially synthesized polymer polycaprolactone treated by a series of chemical methods. Molecules are in a stable state at room temperature (10-30C), and can be softened after being heated in 65-70C water for 1-3 minutes. Curing in 3-5 minutes at room temperature. It has the advantages of light weight, high strength, good air permeability, not afraid of water, non-toxic, odorless, non-irritating to the skin, etc., and has biodegradability. Scope of application: 1. Fixation after reduction of fractures and joint dislocations 2. Postoperative fixation of soft tissue injuries such as joint ligaments, nerve and tendon injuries 3. Bone, joint tuberculosis, acute and chronic osteomyelitis, septic arthritis, primary bone Fixation during conservative treatment such as tumor metastasis or after debridement 4. Joint deformity, nerve palsy, cerebral palsy, scoliosis correction and postoperative fixation in children and fixed 5. Fixation after burns and other plastic surgery operations 6. Production and application of rehabilitation braces and orthoses 7. Posture placement and fixation during radiotherapy
Wrist Splint (Tubular Type) AJY-S07 For wrist or distal forearm fractures, functional fixation of wrist arthroplasty, and rest for wrist arthritis and other lesions Position immobilization or lunate dislocation colles fracture fixation. 300*280*3.2mm LOW TEMPERATURE THERMOPLASTIC SHEET Product features: Low temperature thermoplastic sheet is a new type of material made of specially synthesized polymer polycaprolactone treated by a series of chemical methods. Molecules are in a stable state at room temperature (10-30C), and can be softened after being heated in 65-70C water for 1-3 minutes. Curing in 3-5 minutes at room temperature. It has the advantages of light weight, high strength, good air permeability, not afraid of water, non-toxic, odorless, non-irritating to the skin, etc., and has biodegradability. Scope of application: 1. Fixation after reduction of fractures and joint dislocations 2. Postoperative fixation of soft tissue injuries such as joint ligaments, nerve and tendon injuries 3. Bone, joint tuberculosis, acute and chronic osteomyelitis, septic arthritis, primary bone Fixation during conservative treatment such as tumor metastasis or after debridement 4. Joint deformity, nerve palsy, cerebral palsy, scoliosis correction and postoperative fixation in children and fixed 5. Fixation after burns and other plastic surgery operations 6. Production and application of rehabilitation braces and orthoses 7. Posture placement and fixation during radiotherapy
Thumb plate (tubular type) AJY-S03 For the first metacarpophalangeal joint, thumb phalanx, metacarpal fracture and wrist dislocation fixation. 210*145*3.2mm LOW TEMPERATURE THERMOPLASTIC SHEET Product features: Low temperature thermoplastic sheet is a new type of material made of specially synthesized polymer polycaprolactone treated by a series of chemical methods. Molecules are in a stable state at room temperature (10-30C), and can be softened after being heated in 65-70C water for 1-3 minutes. Curing in 3-5 minutes at room temperature. It has the advantages of light weight, high strength, good air permeability, not afraid of water, non-toxic, odorless, non-irritating to the skin, etc., and has biodegradability. Scope of application: 1. Fixation after reduction of fractures and joint dislocations 2. Postoperative fixation of soft tissue injuries such as joint ligaments, nerve and tendon injuries 3. Bone, joint tuberculosis, acute and chronic osteomyelitis, septic arthritis, primary bone Fixation during conservative treatment such as tumor metastasis or after debridement 4. Joint deformity, nerve palsy, cerebral palsy, scoliosis correction and postoperative fixation in children and fixed 5. Fixation after burns and other plastic surgery operations 6. Production and application of rehabilitation braces and orthoses 7. Posture placement and fixation during radiotherapy
Thumb wrist joint splint (tubular type) AJY-S06 For the first metacarpophalangeal joint, interphalangeal joint and acute arthritis, wrist sprain, synovitis, carpal navicular fracture fixation. 325*185*3.2mm LOW TEMPERATURE THERMOPLASTIC SHEET Product features: Low temperature thermoplastic sheet is a new type of material made of specially synthesized polymer polycaprolactone treated by a series of chemical methods. Molecules are in a stable state at room temperature (10-30C), and can be softened after being heated in 65-70C water for 1-3 minutes. Curing in 3-5 minutes at room temperature. It has the advantages of light weight, high strength, good air permeability, not afraid of water, non-toxic, odorless, non-irritating to the skin, etc., and has biodegradability. Scope of application: 1. Fixation after reduction of fractures and joint dislocations 2. Postoperative fixation of soft tissue injuries such as joint ligaments, nerve and tendon injuries 3. Bone, joint tuberculosis, acute and chronic osteomyelitis, septic arthritis, primary bone Fixation during conservative treatment such as tumor metastasis or after debridement 4. Joint deformity, nerve palsy, cerebral palsy, scoliosis correction and postoperative fixation in children and fixed 5. Fixation after burns and other plastic surgery operations 6. Production and application of rehabilitation braces and orthoses 7. Posture placement and fixation during radiotherapy
Wdj-ssz-1 micro bldc motor surgery system Controller/bldc motor/foot switch Be suitable for all kind of surgery 1. Micro bldc motor surgery system is a set of medical micro-motor system 2. Offer 1,000rpm to 50,000rpm of revolution and greater than 40w output power 3. Motor adopts type-e international standard 4. Can be used in coordination with any type-e standard hand-piece for different surgery 5. It's suitable for craniofacial surgery and maxillofacial surgery, such as harvesting of carnial bone grafts, osteotomy of the frontal bandeau including orbitotomy, osteotomy within the nasal ethmoidal complex, inter dental osteotomy,etc. 6. Both motor and cable can be sterilized in an autoclave (134oc, 2pa) 7. Motor: high torque micro bldc motor 8. Torqure: 230g.Cm , at 20,000rpm 9. Motor speed : 1000rpm---30,000rpm or 1000rpm-50,000rpm 10. Mechanical power output : 45w 11. Nine speed reducing ratios are for selection: 1:1, 4:1, 10:1, 16:1, 20:1, 30:1, 64:1, 100:1 and 256:1 12. Safety classification : type b 13. Interface of motor and hand piece: type e 14. Power supplied: 110v or 220v , 50hz---60hz.
Material: titanium alloy/stainless steel Diameter: ha3.5 length:12-44 ( a group of 2mm) Diameter: ha4.0 length:14-50 ( a group of 2mm) Diameter: ha4.5 length:20-60 ( a group of 2mm). Pe film + dailynizing paper
Material: titanium alloy/stainless steel Diameter:HB3.5 length:12-44 (a group of 2mm) Diameter:HB4.0 length:14-50 (a group of 2mm) Diameter:HB4.5 length:20-60 (a group of 2mm) Diameter:HB6.5 length:30-120 (a group of 5mm). Pe film + dailynizing paper
Material:titanium alloy/stainless steel Diameter: hb4.0 length:16-50 (a group of 2mm ) Diameter: hb6.5 length:30-120 (a group of 5mm ). Pe film +dailynizing paper
Diameter: 0.8 length:50-250 ( a group of 10 mm) Diameter: 1.0 length:50-250 ( a group of 10 mm) Diameter: 1.2 length:50-250 ( a group of 10 mm) Diameter: 1.5 length:50-250 ( a group of 10 mm) Diameter: 2.0 length:50-250 ( a group of 10 mm) Diameter: 2.5 length:250 Diameter: 3.0 length:250 Diameter: 3.5 length:250 Diameter: 4.0 length:250 Diameter: 4.5 length:250 Pe film+dailynizing paper
Material: titanium alloy/stainless steel Diameter: 2.4 Length(mm): 8, 10, 12, 14, 16, 18, 20, 22, 24, 26, 28, 30. Pe film +dailynizing paper
Artificial joints Cast artificial joint products mainly include cast hip joints, cast knee joints, and corresponding operating instruments, etc. Through ten-odd years of trial-manufacture, development and production, rough cobalt-based alloy artificial joints have become one of our symbol products. The company has established the enterprise standard (q/cpchj001-2005) as its internal control standard, whose indicators are higher than those of the industry standard, and the products chemical compositions and performances have been up to or beyond the requirements of astm and iso standards. We are currently supplying products and providing services for more than 20 artificial joint producers in china, and has started to export its products to european and american countries. Our products are well accepted for their good quality and performance. Standard packing
Limited Contact Dynamic Compression Plates for Upper Limbs(LC-DCP)(S/A) Thicknessú¦3mm Holeú¦5ú¼6ú¼7ú¼8ú¼10mm Lengthú¦64ú¼77ú¼90ú¼103ú¼129
Material: Belt:rubber+Nylon Belt length:45cm, width:2.5cm Packing: 1pc/PE bag 300pcs/carton Carton size :58*39*20cm Weight: G.W:11kgs N.W:10kgs
Good X-ray transmission Good waterproof and moisture resistance Good waterproof and moisture resistance Introduction: The polymer fracture splint is a functional polymer, in which the peptide fiber layer is sterilized by ethylene oxide and used in combination with the polymer bandage to achieve a double-effect combination, used for fixation and bandaging of fracture, dislocation, soft tissue injury and other parts. Outstanding advantages Good X-ray transmission Good waterproof and moisture resistance Good waterproof and moisture resistance Usage 1.Select the appropriate type of polymer splint according to the required fixed part. 2.Open the packaging (open one bag at a time, not more than one at a time to avoid failure), remove the splint, soak it in room temperature water for 3~4 seconds and squeeze it for 2~3 times. 3.Remove the excess water and wipe off the water droplets on the surface of the splint. 4.Put it on the place that needs to be fixed, shape it, wrap it with gauze bandage or elastic bandage in spiral form, with moderate tightness. Scope of application Orthopedic or orthopedic fixation, used for orthopedic, hand surgery fracture, sprain, soft tissue, joint ligament tendon fixation, braking.Production of molds, prosthetic AIDS, protective supports for burns, etc. Matters needing attention 1.This product is only for use by medical practitioners 2.If more than two bags are needed, open the second bag after using one bag, and do not open the second bag at the same time. 3.Store it in a dry environment at room temperature, and the packaging bag should not leak air to avoid hardening and failure
Orthopaedic polymer splint is composed of multilayer polymer fiber soaked by polyurethane and polyester. Product Details Introduction:Orthopaedic polymer splint is composed of multilayer polymer fiber soaked by polyurethane and polyester.This product is used in the medical field because of its good biocompatibility. Medical polyurethane is non-toxic and has no teratogenic effect. It has no local irritation and allergic reaction The basic information Name Orthopedic Polymer Splint Appropriate people Fracture patients, orthopedic fixation, sprain Side effects No Storage Store at room temperature and dry place Advantage Convenient operation Sanitary Light, comfortable and suitable Easy to observe injured part Air permeability Good chemical stability The material classification Glass fiber and polyester,namely glass fiber high polymer splint and polyester high polymer splint. Scope of application Orthopaedic or orthopedic fixation, joint ligament tendon fixation, braking. Production of molds, prosthetic AIDS, protective supports for burns, etc.
The high polymer splint is composed of many layers of high polymer fiber soaked by polyurethane and polyester. Product Details Introduction The high polymer splint is composed of many layers of high polymer fiber soaked by polyurethane and polyester. Feature High hardness and light weight Little and light Equivalent to the 1/5 weight of gesso,1/3 weight of polyester Smaller load on injured body Better blood circulation Advantage High hardening speed High strength Waterproof Will not cause itching, ulceration and odor. Method of use 1.Select the appropriate type of polymer splint according to the required fixed part. 2.Open the packaging (open one bag everytimeto avoid failure), remove the splint, soak it in room temperature water for 3~4 seconds and squeeze it for 2~3 times. 3.Remove the excessive water and wipe off the water droplets on the surface of the splint. 4.Put it on the place that needs to be fixed, shape it, wrap it with gauze bandage or elastic bandage in spiral form, with moderate tightness. Samples Photos