Mini Trek Rapid Coronary Dilatation Catheter, 1.5 mm x 8 mm UOM: 1/EA Product Number: 1012269-08 Manufacturer: Abbott Vascular
ABBOTT MINI TREK CORONARY DILATATION CATHETER
Being a renowned and the highly trusted enterprises in this industry, we are offering an optimum quality assortment of Sapphire Coronary Dilatation Catheter.
Terumo Runthrough NS PTCA is a medical device designed for use in percutaneous transluminal coronary angioplasty (PTCA) procedures. PTCA is a minimally invasive procedure used to treat coronary artery disease by widening narrowed or blocked coronary arteries. Here are some key points about the Terumo Runthrough NS PTCA: Manufacturer: Terumo Corporation is a Japanese company known for its medical devices and healthcare products. Type: The Runthrough NS PTCA is a guide wire used in PTCA procedures. Guide wires are essential tools that help navigate catheters and other interventional devices through blood vessels during angioplasty. Function: The guide wire assists in guiding and positioning the catheter within the coronary arteries. It helps the interventional cardiologist navigate through the blood vessels and reach the site of the blockage or narrowing. Features: The "NS" in Runthrough NS may refer to "non-support" or "normal support," indicating the level of support provided by the guide wire. The choice of guide wire depends on factors such as the location and severity of the arterial blockage. Usage: The Terumo Runthrough NS PTCA guide wire is specifically designed for use in PTCA procedures to help facilitate the placement of angioplasty balloons and stents.
1) More options in diameter ranges(CTO: 1.0mm-1.25mm; SC:1.5mm-4.0mm & NC: 2.0mm-5.0mm ); 2) More choices in balloon length (CTO &SC: 10mm-30mm; NC:8mm-18mm ) 3) Higher Rated Pressure (16atm for CTO& SC; 20-22 atm for NC); In addition, the average balloon burst pressure for NC reaches 35-40atm 4) Special hydrophilic coating on balloon, dismal shaft and tip, which made our frictional coefficient merely half of competitors' 5) Better flexibility thanks to Pebax-made balloon 6) Extraordinary minor balloon axial growth(3%) while inflation and 5F guiding cathether compatible 7) Tip Entrance Profile is 0.016'', Crossing profile for 3.0mm-diameter balloon is 0.0355''
the Boston Scientific Promus Elite is a coronary drug-eluting stent system. It is designed for use in patients undergoing percutaneous coronary intervention (PCI) procedures to treat coronary artery disease. Here are some key features and points related to the Boston Scientific Promus Elite coronary stent: Drug-Eluting Stent: The Promus Elite is a drug-eluting stent (DES), meaning it is coated with medication to help prevent the re-narrowing (restenosis) of the treated coronary artery. Drug Coating: The stent typically features a polymer coating containing an anti-proliferative drug. This drug is slowly released over time to inhibit the growth of tissue inside the stent, reducing the risk of restenosis. Cobalt Chromium Alloy: The stent is often made of a cobalt chromium alloy, known for its strength and flexibility. This material allows for a thin stent strut design, which can be beneficial in terms of deliverability and conformability. Delivery System: The stent is delivered to the target area using a catheter-based delivery system. The catheter is guided through the blood vessels to the site of the coronary artery lesion. Radiopaque Markers: Radiopaque markers on the stent aid in proper placement and visualization under X-ray guidance during the procedure.
he Terumo Runthrough NS PTCA (Percutaneous Transluminal Coronary Angioplasty) guide wire is a product manufactured by Terumo Corporation, a global medical device company. Guide wires are essential tools used in cardiovascular procedures, particularly in angioplasty and stenting, to navigate through blood vessels and provide support for the delivery of catheters and other interventional devices. Key features and characteristics of the Terumo Runthrough NS PTCA guide wire may include: Hydrophilic Coating: Many Terumo guide wires, including the Runthrough NS, are known for their hydrophilic coating. This coating facilitates smoother navigation through blood vessels, reducing friction and enhancing steerability. Flexible Design: The guide wire is designed to be flexible, allowing it to navigate tortuous vessels and reach target locations with precision. Radiopaque Tip: The tip of the guide wire is often radiopaque, making it visible under fluoroscopy or other imaging modalities. This feature helps interventional cardiologists visualize the position of the guide wire during the procedure. Different Tip Configurations: Guide wires may come with different tip configurations, such as soft or floppy tips for ease of navigation or more supportive tips for crossing lesions. Various Lengths and Diameters: Terumo typically offers guide wires in various lengths and diameters to accommodate different patient anatomies and procedural requirements.
BOSTON SCIENTIFIC MAVERICK MONORAIL DILATATION CATHETER H7493892815200 BOSTON SCIENTIFIC MAVERICK MONORAIL DILATATION CATHETER H7493892820200 BOSTON SCIENTIFIC MAVERICK MONORAIL DILATATION CATHETER H7493892815250
BOSTON SCIENTIFIC QUANTUM MAVERICK DILATATION CATHETER H7493808012300 BOSTON SCIENTIFIC QUANTUM MAVERICK DILATATION CATHETER H7493808012350 BOSTON SCIENTIFIC QUANTUM MAVERICK DILATATION CATHETER H7493808012250
PTA scored balloon dilatation catheter (abbreviated as balloon catheter) is composed of a tip, a marker ring, a balloon, a metal scored stent, a welded tube, an elastic connecting tube, an inner tube, an outer tube, a catheter reinforcement tube and a catheter seat. The surface of the balloon catheter is coated with a hydrophilic coating, and the hydrophilic coating covers a length area of 400 mm �± 50 mm from the outer tube connected to the elastic connecting tube to the position of the catheter reinforcing tube . PTA scoring balloon dilatation catheter positioning global products, we gradually follow up planning to sell to the European Union, users are needed for the peripheral vascular system ( including the iliac artery, femoral artery, iliofemoral artery, iliac artery, inferior iliac artery and renal artery ) Patients undergoing percutaneous transluminal angioplasty (PTA) surgery are suitable for the treatment of occlusive lesions of arteriovenous fistula for autologous or artificial dialysis
NC Trek Catheter, Rapid, 3 mm x 12 mm UOM: 1/EA Product Number: 1012449-12 Manufacturer: Abbott Vascular
NC Trek Catheter, Rapid, 4.5 mm x 12 mm UOM: 1/EA Product Number: 1012454-12 Manufacturer: Abbott Vascular
NC Trek Catheter, Rapid, 3.75 mm x 15 mm UOM: 1/EA Product Number: 1012452-15 Manufacturer: Abbott Vascular
NC Trek Catheter, Rapid, 3.5 mm x 15 mm UOM: 1/EA Product Number: 1012451-15 Manufacturer: Abbott Vascular
NC Trek Catheter, Rapid, 2.5 mm x 15 mm UOM: 1/EA Product Number: 1012447-15 Manufacturer: Abbott Vascular
BOSTON SCIENTIFIC NC QUANTUM APEX PTCA DILATATION CATHETER
We Can Supply Boston Scientific Coyote Over The Wire Pta Balloon Dilatation Catheter H74939186201010 Please Don't Hesitate To Contact Us In Case Of Any Interested
Coyote ES Over-the-Wire Balloon Dilatation Catheter with 145 cm Shaft and 3 x 40 mm Balloon UOM: 1/EA Product Number: H74939134304010 Manufacturer: Boston
NC Trek Catheter, Rapid, 2.5 mm x 8 mm UOM: 1/EA Product Number: 1012447-08 Manufacturer: Abbott Vascular
Mowell Central Venous Single Lumen Catheter 16G X 6.29 Product Code: MW-LUMEN-01 Specifications: Guide wire Marked : 032"(.81mm) dia "J" Tip (Y-Shape) introducer Needle : 18G X70mm | Fastener Catheter clamp Normal Syringe 5ml | Dilator : 6.5F X 10cm | Catheter : clamp Injection cap | injection needle | Scaple # 11 Size/Strength: SIZE : Single , Double and Triple Single Lumen Central Venous Catheter Set Centrally inserted, single lumen central venous catheter. For administration of hyperosmolar solutions, measuring CVP, hemodialysis, plasmapheresis, rapid infusion of fluid among other uses. Mowell provides the benefit of polyurethane catheter which is soft, kink resistant, extremely biocompatible with excellent wear properties and elastic memory.