1.General description The luminox family (lox) is a range of factory calibrated oxygen sensors which measure ambient oxygen partial pressure (ppo2) levels using the principle of fluorescence quenching by oxygen. By default luminox measures ppo2 (mbar) and temperature (°c). An optional pressure sensor enables luminox to also measure barometric pressure (mbar) and to convert the ppo2 reading to an oxygen concentration (o2%). The sensor benefits from low power operation, traditionally associated with electrochemical sensors, while providing a much longer lifetime due to the non-depleting sensing principle. Luminox is ppo2 and temperature compensated, enabling accurate operation over a wide environmental range without the need for additional system components. Unlike other sensor technologies, luminox is very stable and robust, does not contain lead or any other Hazardous materials and has negligible cross sensitivity to other gases. 2.Cleaning The housing of the sensor can be cleaned using a damp cloth. The sensor should not be immersed in any cleaning media. Full application and technical support can be provided by our knowledgable and highly experienced engineering team if required. 3.Benefits -low power -can also measure o2% & barometric pressure (lox-02) -suitable for battery power use -long life - high accuracy - small & compact - low cost -maintenance free contains no hazardous materials -connects directly to microcontroller - without any additional circuitry. - factory calibrated 4.Applications -oxygen detection -portable equipment - breathing apparatus - inerting - medical -lab equipment - agriculture -incubation -fire prevention - flue gas in condensing boilers
LOX-02-F LuminOx Flow-through Optical Oxygen Sensor General Description The LuminOx Flow-Through Optical Oxygen Sensor Allows For A Clean Gas Sample Stream Directly Into The Sensor Which Can Be Completely Removed From The Process Environment. The LuminOx Flow-through Optical Oxygen Sensor is developed and manufactured by SST, it is part of the LuminOx family, which is a range of factory calibrated oxygen sensors which measure ambient oxygen levels using the principle of fluorescence quenching by oxygen, also known as luminescence quenching. The LuminOx Flow-through Optical Oxygen Sensor (LOX-02-F) is an extension to the standard range of LuminOx oxygen sensors. The original LOX-02 sensor was designed to be completely immersed in the sample gas environment as the base of the sensor is not gas-tight. The flow-through housing style is sealed on the base which allows for a clean gas sample stream into the sensor which can be completely removed from the process environment. A flow-through housing allows for better sample gas management and options in terms of where the sensor can be situated. The patented technology allows SST to produce a range of sensors that are based on a non-depleting operating principle. This can contribute to the LuminOx sensors having a comparably longer lifetime that other competitor technologies, such as galvanic sensors, for similar applications. LOX-02-F LuminOx Flow-through Optical Oxygen Sensor Features * Luminescence-based optical technology, NOT electrochemical * Contains no hazardous materials; RoHS & REACH compliant * Connects directly to a microcontroller without any additional circuitry * Factory calibrated * High accuracy, fast response * Maintenance free LOX-02-F LuminOx Flow-through Optical Oxygen Sensor Benefits * Compact, flow-through housing with sealed base * Low power, long life due to non-depleting sensing principle * Low cos OX-02-F LuminOx Flow-through Optical Oxygen Sensor Technical Specifications *â?¢ Supply voltage: 4.5 - 5.5V DC * Supply current:
The luminox family is a range of factory calibrated optical sensors which measure ambient o2 levels using the principle of fluorescence quenching by oxygen. Our unique patented process allows us to produce an oxygen sensor that benefits from low power, traditionally associated with electrochemical sensing devices, while providing a much longer lifetime due to the non-depleting sensing principle. * low drift * rohs compliant * extended temperature range compared to electrochemical sensing devices * low in cost * factory calibrated * measures temperature and pressure (if selected) * small and compact * maintenance free Luminox unlike other sensor technologies is stable and robust, it is rohs compliant as it does not contain lead or any other hazardous materials and has negligible cross sensitivity. Luminox can be purchased as a single optical sensor, or as part as an evaluation kit which includes the luminox sensor evaluation interface board, which was designed to allow customers to easily evaluate the sensor with minimum effort or design work. Typical applications for the luminox optical oxygen sensor are; * oxygen detection * portable equipment * breathing apparatus * inerting * medical * lab equipment * agriculture * incubation * fore prevention * flue gas in condensing boilers Part numbering system Lox - xx 01: measures 0-300 mbar ppo 2 and temperature (â°c) 02: measures 0-300 mbar ppo 2 , 0-25% o 2 , temperature (â°c) and 500-1200mbar barometric pressure -
LOX-02-S LuminOx Sealed Optical Oxygen Sensor General Description The LuminOx Sealed Optical Oxygen Sensor Range Offers Users With Application Requirements To Only Measure Sample Gas At The Front Face Of The Sensor. The LuminOx Sealed Optical Oxygen Sensor is developed and manufactured by SST, it is part of the LuminOx family, which is a range of factory calibrated oxygen sensors which measure ambient oxygen levels using the principle of luminescence quenching. The LuminOx Sealed Optical Oxygen Sensor (LOX-02-S) is an extension to the standard range of LuminOx oxygen sensors. It is a similar diffusion type sensor like the original LOX-02 sensor. However, the LOX-02-S has a sealed base that is gas-tight, meaning only the face of the sensor with the protective membrane needs to be in the sample gas environment, externally leaving easy access to the pins of the sensor. LOX-02-S LuminOx Sealed Optical Oxygen Sensor Features * Luminescence-based optical technology, NOT electrochemical * Contains no hazardous materials; RoHS & REACH compliant * Connects directly to a microcontroller without any additional circuitry * Factory calibrated * High accuracy * Maintenance free LOX-02-S LuminOx Sealed Optical Oxygen Sensor Benefits * Compact, diffusion-type housing with sealed base * Low power, long life due to non-depleting sensing principle * Low cost LOX-02-S LuminOx Sealed Optical Oxygen Sensor Technical Specifications * Oxygen range: 0 - 25% O2 * Oxygen pressure range: 0 - 300mbar ppO2 * Response time: T90 < 30s (typical) * Supply voltage: 4.5 - 5.5V DC * Supply current:
Pale yellow liquid at room temperature characteristic odor and taste or nearly odorless, free from rancidity or any objectionable odor and taste. Each batch of materials shall undergo strict sampling,inspection and screening for guaranteeing the affluent oil production and the excellent oil fragrance. Groundnut OIL Taste Neutral Impurities Negative Free Fatty Acid ( % ) max 0,10 Moisture ( % ) max 0,05 Peroxide Value ( meq O2/ kg ) max 5 Specific gravity at 20 degr C 0,91 - 0,93 Iodine value ( g / 100 g ) 82 - 110 Colour Lovibond 5 1/4 " Red max 2,5 Colour Lovibond 5 1/4 " Yellow max 25 C 12:0 C 14:0 (Myristic Acid) C 16:0 ( Palmitic Acid ) 6 - 14 C16:1 (Palmitoleic Acid) C 18:0 ( Stearic Acid ) 1 - 5 C 18:1 ( Oleic Acid ) 35 - 72 C 18:2 ( Linoleic Acid ) 13 - 44 C 18:3 ( Linolenic Acid )
optical oxygen sensor O2 Gas sensor LOX-02 Description The LuminOx Family is a range of factory calibrated optical sensors which measure ambient O2levels using the principle of fluorescence quenching by oxygen. Our unique patented process allows us to produce an oxygen sensor that benefits from low power, traditionally associated with electrochemical sensing devices, while providing a much longer lifetime due to the non-depleting sensing principle. Applications Typical applications for the Cheap Price Oxygen Sensor LOX-02 are; Oxygen detection Portable equipment Breathing apparatus Inerting Medical Lab equipment Agriculture Incubation Fore prevention Flue gas in condensing boilers
Measuring Range - 0-100% Range of Precision - 70-10% Measuring Precision - 2% Resolution - 1% Data update time - 1s Pulse Rate Measuring Range - 18-250bpm Range of Precision - 25-250bpm Measuring Precision - 3bpm Resolution - 1bpm Data update time - 1s Packing Information Working Size - 7cm*3cm*2.4cm Packing Size - 40cm*37cm*24cm N.W. - 0.075kg G.W - 0.15kg
Taste Neutral Impurities: Negative Free Fatty Acid (%): max 0,10 Moisture (%): max 0,05 Peroxide Value (meq O2/kg): max 5 Specific gravity at 20 degr C: 0.91 - 0.93 Iodine value (g/100g): 103 - 128 Colour Lovibond 5 1/4 " Red: max 2.5 Colour Lovibond 5 1/4 " Yellow: max 25 C 12:0 C 14:0 (Myristic Acid) C 16:0 ( Palmitic Acid ): 10 - 15 C16:1 (Palmitoleic Acid) C 18:0 ( Stearic Acid ): 1 - 4 C 18:1 ( Oleic Acid ): 23 - 39 C 18:2 ( Linoleic Acid ): 42 - 61 C 18:3 ( Linolenic Acid ): 0.5 - 1.5 C 20:0 ( Arachidic Acid ): 0.2 - 1.2 C 20:1 ( Gadoleic Acid ):0.1 - 1 C 20:2 (Eicosenic Acid) C 22:0 ( Behenic Acid ): 0.1 - 1 C 22:1 ( Erucic Acid ): < 0.3 C 24:0 ( Lignoceric Acid )
Luminox ppm fluorescence o2 sensors features * fluorescenceâ??based optical technology * contains no hazardous materials; rohs & reach compliant * factory calibrated * high accuracy * maintenance free * long life, non-depleting technology - can be stored in any oxygen % Luminox ppm fluorescence o2 sensors benefits * low power, long life due to non-depleting sensing principle * compact footprint Luminox ppm fluorescence o2 sensors technical specifications Supply voltage (vs) : 8-30v dc Supply current (ls) :
The Gurjun Balsam Essential Oil from Aromas Oils is 100 pure and natural crafted from the resinous gum of the Gurjun tree This topquality essential oil is renowned for its numerous benefits to consumers Botany Scientifically named Dipterocarpus Turbinatus Gurjun Balsam is a deciduous tree belonging to the Dipterocarpaceae family Native to Southeast Asia this towering tree reaches a height of 3035 meters Its bark is dark brown shallow and flaky Overview of Gurjun Essential Oil Gurjun Balsam Essential Oil also known as Gurjun balsam oil is a clear pale yellow liquid with a natural woody and zesty fragrance Extracted through steam distillation from the wood of the Gurjun tree it is extensively used in perfume cosmetics and medicinal formulations Benefits of Gurjun Essential Oil Assists in relieving muscle and joint pains by eliminating toxins from the body The nutty and woody scent makes it suitable for use in perfumeries Promotes skin health by treating wounds cuts rashes ringworm boils and psoriasis Aids in addressing respiratory problems such as asthma chest congestion and bronchitis Blends well with Gurjun Balsam essential oil blends harmoniously with Black pepper Ginger and Patchouli Precautionary Measures Dilute Gurjun Essential Oil with coconut oil olive oil or almond oil before topical application Pregnant or breastfeeding women are advised against using Gurjun Essential Oil Botanical Name Dipterocarpus Turbinatus CAS 8030555 Color amp Odor Pale yellow to amber clear oily liquid amp Fresh nutty scent odor FEMA No Methods of Extraction Steam Distillation Constituents Bcaryophyllene agurjunene Bgurjunene Solubility Soluble in alcohol insoluble in water Specific Gravity 09070 09250 Flash Point 210 F Optical Rotation 60 to 0 Major Constituents Bcaryophyllene agurjunene Bgurjunene Volume 100 ml 250 ml 500 ml 1 Ltr 5 Ltr 10 Ltr 25 Ltr
Sodium Fatty Acid Methyl Ester Sulfonate, MES 70% paste Essential details Classification: Sulfonic Acid CAS No.: 27176-87-0 Other Names: LABSA,DBSA,DDBSA MF: R-C6H4-SO3H(R=C12) EINECS No.: 204-489-3 Grade Standard: Industrial Grade Purity: 96% Appearance: brown adhesive liquid Application: Washing Powder & liquid detergent Product name: LABSA Production standard: international standards Surfactant: Anion Surfactant Feature: High purity Sulfonic Acid Purity of Sulfonic Acid: 96% Supply Ability 5000 Metric Ton/Metric Tons per Month Packaging Details 210kg/drum: 16.8MT/20'FCL 1000kg/IBC: 18MT/20'FCL Hot sale daily chemical & detergents LABSA 96 Storage of labsa: Store labsa in dry and cool place, kept away from sunshine and rain. 1. Product identification of Sulfonic Acid LABSA 96% Product name Linear Alklybenzene Sulphonic Acid Chemical synonym LABSA Formula RC6H4SO3H, R=C10H21-C13H27 Properties Brown Viscous liquid; Boiling Point(�°C): >100; Specific Gravity/Density (g/ml): 1.029 HS No. 34021100 CAS No 27176-87-0 EINECS No 287-494-3 2. Specification of Sulfonic Acid LABSA 96% Item Specification Measuring Method First class quality Qualified product Alkyl benzene Sulfonate(%) â?¥96.0 â?¥96.0 GB/T 8447 Color Klett 20 Max 40Max Free Oil (%) 1.5Max 1.8Max Sulfuric Acid (%) 1.5 Max 1.5Max Chemical Formula R-C6H4-SO3H Appearance 25 C The viscous liquid with pale yellow and brown CAS No. 27176-87-0
Mowell Non-Contact Infrared Forehead Thermometer Gun Type For Fever used for Baby and Adult Specifications: One Second Measurement: The high technology and quality sensor can be used to measure body more quickly and confortably. LED Luminous Display Function: Easily taking measurement during night, without disturbing baby 1-second rapid measurement temperature, especially the forehead readings, as it does not bother the patient during crucial rest moments. Non-Contact Digital Infrared Temperature Gun not only supports forehead function but is able to take room/object temperature. Forehead Thermometer is ideal for forehead readings, and have a very small error margin(0.2F for body mode, and 1.0F for ambient mode. It is actually more accurate than standard mercury thermometers. Health Indicator and alarm colors for monitoring the health of the baby all the time. The value of the memory data indicates the early measurements. Taking your babyâ??s temperature with this digital thermometer is as simple as pointing and pressing a button. It uses infrared technology and can show readings in Celsius or Fahrenheit.This thermometer for fever readings can be used in the dead of night without even switching on the light. Because the HD LED screen will display clear and crisp numbers that are easy to read. â??Measured body temperature, surface temperature of body, for example monitor children fever or not Soil temperature.Measured surface temperature of object, such as cup, cake and frozen foods etc.Liquid temperature:Measured liquid temperature, such as baby bath water, milk in feeder, baby rice paste etc. Product unique selling point:Wide temperature range, multi-purpose.Temperature range from 0 to 100, both measured body temperature, also surface temperature of body. Measured temperature of environment, baby feeder, rice paste and bath water, besides, displayed clock. Most of thermometer without wide temperature range design, or just only measured 60 C
Mowell Non-Contact Infrared Forehead Thermometer Gun Type For Fever used for Baby and Adult Specifications: One Second Measurement: The high technology and quality sensor can be used to measure body more quickly and confortably. LED Luminous Display Function: Easily taking measurement during night, without disturbing baby 1-second rapid measurement temperature, especially the forehead readings, as it does not bother the patient during crucial rest moments. Non-Contact Digital Infrared Temperature Gun not only supports forehead function but is able to take room/object temperature. Forehead Thermometer is ideal for forehead readings, and have a very small error margin(0.2�°F for body mode, and 1.0�°F for ambient mode. It is actually more accurate than standard mercury thermometers. Health Indicator and alarm colors for monitoring the health of the baby all the time. The value of the memory data indicates the early measurements. Taking your babyâ??s temperature with this digital thermometer is as simple as pointing and pressing a button. It uses infrared technology and can show readings in Celsius or Fahrenheit.This thermometer for fever readings can be used in the dead of night without even switching on the light. Because the HD LED screen will display clear and crisp numbers that are easy to read Measured body temperature, surface temperature of body, for example monitor children fever or not Soil temperature.Measured surface temperature of object, such as cup, cake and frozen foods etc.Liquid temperature:Measured liquid temperature, such as baby bath water, milk in feeder, baby rice paste etc. Product unique selling point:Wide temperature range, multi-purpose.Temperature range from 0 to 100, both measured body temperature, also surface temperature of body. Measured temperature of environment, baby feeder, rice paste and bath water, besides, displayed clock. Most of thermometer without wide temperature range design, or just only measured 60C
Autoclave Pressure cooker type, Mirror Finish, Non-Electric (External Fuel Heated), Capacity 40 Ltrs Specifications: It uses steam to sterilize medical equipment, surgical dressings, glass, utensils, etc. rapidly and efficiently. Made of heavy duty seamless aluminum sheet. Long lasting. The lid is equipped with both a safety valve and steam release valve. A pressure gauge allow precise pressure tracking and safety. Mirror Finish. External Fuel Heated. Perfect for hospitals, public health centers, health stations, clinics, and research institutes. Size (D x H) : 350mm X 330mm + 90mm Lid. (14x16). Approximate Capacity (Ltrs.) : 40 Liters. With lid. Finish : Mirror Finish. Suitable for two Sterilizing / Dressing Drum (11x9) & (11x4.5) (Drum Not Included Drum Cost is Extra). Supplied with inner & outer stand. OPERATING INSTRUCTION / INSTRUCTION MANUAL : PASTED ON THE AUTOCLAVE. All aluminum deep-drawn seamless construction Mirror Finish. External Fuel Heated Supplied with inner & outer stand. All autoclaves are constructed from heavy gauge aluminum. It generates steam under pressure and temperature between 120C to 135C. Made from seamless Aluminium, top-loading autoclaves. Seamless construction ensures a bacteria-free environment, 25-30 minutes sterilizing cycle at 121c. With two stages overpressure protection system incorporating a calibrated continuous bleeding pressure stopcock and pressure release weight valve. With heat-resistant handles and steam release/control valve. Pressure Gauge: Color-coded pressure gauge showing internal chamber conditions during the cycle. The sterilization zone in green color is shown from 15 psi to 20 psi (OR 1.034 bar to 1.378 bar) which is equivalent to temperature of 121c to 127c. Dial size- 2.5?,Dial show measurement in 2 units (i) kg/cm² (ii) lb/inch². Full scale dial of pressure gauge is 0-30 lb/ inch or 0-2 kg/ cm. Caution zone in red color.
Thank you for purchasing and using our company's ultrasonic oxygen concentration / flow sensor. 1, please carefully read the instructions and fully understand the contents of the sensor after operation and maintenance. Improper use may cause damage to the sensor. (no violent impact and falling ground) 2, without the consent of the company, it is strictly prohibited to alter the structure and components of the sensor without authorization. The company is not responsible for any personal safety incidents or sensor abnormalities caused by unauthorized alterations. 3, the specifications and instruction contents of this sensor may be changed due to the technical improvement of the product. 4, this instruction manual must be handed to the actual user of the sensor and stored in it, and placed at any time where the actual user of the sensor can access it. 5, the company has the right to interpret the instructions for the sensor. 2ã??technical parameter Measurement parameters measuring method range Resolution accuracy O2 Ultrasonic 20.5%-95.6% 0.1% �±1.8%FS 5-45â?? Note: the range can be customized according to customer requirements. Sample gas requirements Water removal (no condensation); dust filtration (
Specifications: Individually pack in a corrugated box with Accessories Suitable for adult, pediatric and neonatal patients Up to 24 hours of tabular and graphical patient data trends High resolution Graphic TFT color display for on screen preview Audio tones to differentiate oxygen saturation level Built-in rechargeable battery support up to 3 hours Peak detection alarm O2 probe sensor Off indication Portable and battery operated Digital display for clear viewing from distance High/Low limit alarm for SPO2 & Pulse Rate Adjustable audible and visual alarms
O2-M2 Oxygen Sensor Description Alphasense Oxygen sensors use capillary flow control. Unlike partial pressure oxygen sensors, they have good pressure and temperature dependence, making them the best choice in safety applications. Standard galavanic sensors use lead for greatest reliability but fixed lifetime. Specifications * Output: 80 to 120 uA @ 20.9% O2 * Response time t90: < 15 (s) from 20.9% to 0% O2 * Linearity: 0.6 % O2 deviation @ 10% O2 * Operating life: > 24 months *Temperature range: -30 to 55 'C * Pressure range: 80 to 120 kPa * Humidity range: 5 to 95 % rh continuous * Diameter: 20.0 mm (including label) * Heigh: 17.4 mm (including foam ring) * Weight: < 16g
Features * oxygen pressure range 2 mbar - 3bar * zirconium dioxide (zro2 ) sensing elements * non-consumption technology * integral heating element * no need for temperature stabilisation * no reference gas required * high accuracy * linear output signal * operates with external interface boards Specifications Heater voltage: Porous cap (15mm): 4.35v dc +/- 0.1v dc (1.85a) Stand by: 2v dc (0.85a) Pump resistance @ 700'C: < 6kOhm Permissible gas temperature: -100 to 250C Gas flow rate: 0 to 10 m/s Repetitive permissible acceleration: 5 g Incidental permissible acceleration: 30 g
O2-a2 oxygen sensor Performance Output î¼a @ 20.9% o2 80 to 120 Response time t90 (s) from 20.9% to 0% o2 < 15 Zero current î¼a in n2 < 2.5 Linearity % o2 deviation @ 10% o2 0.6 Lifetime Output drift % change in output @ 3 months < 1 Operating life months until 85% original output of 20.9% o2 > 24 Environmental Humidity sensitivity % o2 change: 0% to 95% rh @ 40â?? < 0.7 Co sensitivity % (change o2 reading) / % co2 @ 5% co2 0.1 Pressure sensitivity (% change of output)/(% change of pressure) @ 20kpa < 0.1 Key specifications Temperature range â?? -30 to 55 Pressure range kpa 80 to 120 Humidity range % rh non-condensing (0 to 99% rh short term) 5 to 95 Storage period months @ 3 to 20â?? (store in sealed pot, open circuit) 6 Load resistor î© (recommended) 47 to 100 Diameter mm (including label) 20.0 Height mm (including foam ring) 17.4 Weight g < 16 -
Zirconia O2 Sensors Probe Series - Short Housing The Probe Range of zirconium dioxide oxygen sensors are available in three lengths. Suitable for aggressive and polluted applications such as boiler exhausts. Longer probes are an ideal solution for thicker walled, insulated flue pipes. FEATURES * Zirconium dioxide (ZrO2) sensing elements * Long life, non-depleting technology * Integral heating element * High accuracy * Requires an external interface board to operate BENEFITS * No reference gas required * No need for temperature stabilisation * Compact enclosure TECHNICAL SPECIFICATIONS Heater voltage Operating (standard response) 4V DC ± 0.1V DC (1.7A) Standby 1.65V DC (0.7A) Operating (fast response) 4.35V DC ± 0.1V DC (1.85A) Standby 2V DC (0.85A) Pump impedance at 700'C < 6kΩ Permissible gas temperature -100'C to +250'C Gas flow rate 0 ~ 10 m/s Repetitive permissible acceleration 5g Incidental permissible acceleration 30g OUTPUT VALUES Oxygen pressure range 2mbar ~ 3bar max Accuracy 5mbar max Internal operational temperature 700'C Response time (10 - 90% step) Standard response sensor < 15s Fast response sensor < 4s Warm up time (prior to sensor operation) 60s Warm up time (from standby) 20s Output stabilisation time ~ 180s