LSG-1800BCCD Goniospectroradiometer is high precision automatic goniophotometric instrument for luminous intensity distribution measurements with facility for turning the light source. The LSG-1800BCCD can do the spatial CCT test when do the intensity distribution test. It is for industrial laboratory measurements the photometric data of luminaires such as LED luminaries, HID lamps, fluorescent lamps and so on. Measurement: Luminous Intensity Data, Luminous Intensity Distribution, Zonal Luminous Flux, Luminaries Efficiency, Luminance Distribution, Coefficient Of Utilization, Luminance Limitation Curves Glare, Maximum Ratio of Distance to Height, Equal Illuminance Diagrams, Curves of Luminaires VS Lighting Area, Isocandela Diagrams, Efficient Luminescence Angle, EEI, UGR, CCT, CRI, Color Temperature Distribution, Spectrum, (x, y)/(u, v) and etc. Specification: LSG-1800BCCD Goniospectroradiometer=LSG-1800B Goniophotometer System + LPCE-2 Integrating sphere Spectroradiometer System The Europe classical goniophotometer which is fully meet EN13032-1 clause 6.1.1.3 goniophotometer type 1. â?¢ The goniophotometer can do the B-β test with two pillars and C-γ test with single pillar & multi-function jigs â?¢ The accuracy of angle: 0.1° (LSG-1800XCCD/LSG-1800BCCD) and 0.2° (LSG-1700BCCD) â?¢ Work with High Accuracy and quick CCD Spectraidomeeter to measure spatial color parameters. â?¢ Accuracy of chromaticity coordinate: ±0.0005 (under standard A lamp) â?¢ Spectral Range Wavelength: 380nm ~780nm; Accuracy of wavelength: ±0.5nm â?¢ Accuracy of photo detector: CIE Class A (Class L is for option) â?¢ Connect to PC via USB, English version software can be run in Win7, Win8 or Win10 â?¢ The test result can be exported as CIE, IES, LDT and other format files. This kind of format files can be transferred by other illumination and luminaire design software such as DiaLux Max Size for the Testing Lamp (mm) The Max Size for the Testing Lamp Max Weight Non-Flood Lamp Diameter*Depth Flood Lamp (L*M) LSG-1800XCCD Φ 2500*550mm 700*600mm 60Kg LSG-1800BCCD Φ 1600*550mm 700*600mm 50Kg LSG-1700BCCD Φ 1600*580mm 700*600mm 30Kg
LSG-5000 Moving Detector Goniophotometer completely meets LM-79 Clause 9.3.1 and EN13032-1 clause 6.1.1.3 goniophotometer type 4 requirements. The LSG-5000 is an automatic light distribution intensity 3D curve testing system for measuring light. The measuring distance is from 5m to 30m. It can measure all types of lighting sources, LED or HID luminaires such as indoor and outdoor luminaires, roadway luminaires, street lamps, flood lights and other kinds of luminaires. Measurement: Luminous Intensity Data, Luminous Intensity Distribution, Zonal Luminous Flux, Luminaries Efficiency, Luminance Distribution, Coefficient Of Utilization, Luminance Limitation Curves Glare, Maximum Ratio of Distance to Height, Equal Illuminance Diagrams, Curves of Luminaires VS Lighting Area, Isocandela Diagrams, Efficient Luminescence Angle, EEI, UGR and etc. Features: â?¢ The near field detector moved together with the big mirror in a line, the big mirror and far field detector move synchronously. â?¢ The lumainares will be keep the burning position without moving at all, and the detector will always sense the light directly from the luminares. â?¢ The rotation motor is from Japan MITSUBISHI MOTORS and it uses Germanic angle decode system, it will help smoothly and high accuracy rotation. It is very stable when start and stop. â?¢ The working principles are according to IESNA and CIE. The LSG-5000/LSG-3000 are completely meet the LM-80, LM-79, LM-75, GB, EN and CIE121-1996. â?¢ Special collimation device with laser cross line, conveniently and accurately fix the position of the tested luminaries. Specifications: â?¢ The tested luminaire rotates around the mirror with an angle of (γ) ±180° (or 0-360°) and the tested luminaire rotates around itself with an angle of (C) ±180° (or 0-360°). â?¢ The accuracy of angle: 0.05°, Resolution of angle: 0.001° â?¢ Accuracy of photo detector: Constant temperature photo detector DIN5032-6/CIE pub1. No. 69 Class L (LSG-5000) â?¢ The test result can be exported as CIE, IES, LDT and other format files. This kind of format files can be transferred by other illumination and luminaire design software such as DiaLux. â?¢ Connect to PC via USB, English version software can be run in Win7, Win8 or Win10 â?¢ LSG-5000 can be used with a USB CCD Spectroradiometer to test spatial CCT Distribution and other Spectral color parameters. We call this system Goniospectroradiometer (LSG-5000CCD). LSG-5000CCD Goniospectroradiometer=LSG-5000 Goniophotometer System + LPCE-2 Integrating sphere Spectroradiometer System. Please download the LSG-5000CCD Brochure. Model No LSG-5000B (Big Size) LSG-5000 (Standard Size) LSG-5000S/LSG-3000B (Small Size) Measure Non-Flood Lamp Φ 1600*800mm, 50kg Φ 1400*500mm, 40kg Φ 1000*460mm, 30kg Measure Flood Lamp 600*600mm, 50kg 600*600mm, 40kg 400*400mm, 30kg Measure Power (W) 600V/10A, AC/DC 600V/10A, AC/DC 600V/10A, AC/DC PS. The LSG-5000X are special size which According to customers request
LSG-5000 Moving Detector Goniophotometer completely meets LM-79 Clause 9.3.1 and EN13032-1 clause 6.1.1.3 goniophotometer type 4 requirements. The LSG-5000 is an automatic light distribution intensity 3D curve testing system for measuring light. The measuring distance is from 5m to 30m. It can measure all types of lighting sources, LED or HID luminaires such as indoor and outdoor luminaires, roadway luminaires, street lamps, flood lights and other kinds of luminaires. Measurement: Luminous Intensity Data, Luminous Intensity Distribution, Zonal Luminous Flux, Luminaries Efficiency, Luminance Distribution, Coefficient Of Utilization, Luminance Limitation Curves Glare, Maximum Ratio of Distance to Height, Equal Illuminance Diagrams, Curves of Luminaires VS Lighting Area, Isocandela Diagrams, Efficient Luminescence Angle, EEI, UGR and etc. Features: â?¢ The near field detector moved together with the big mirror in a line, the big mirror and far field detector move synchronously. â?¢ The lumainares will be keep the burning position without moving at all, and the detector will always sense the light directly from the luminares. â?¢ The rotation motor is from Japan MITSUBISHI MOTORS and it uses Germanic angle decode system, it will help smoothly and high accuracy rotation. It is very stable when start and stop. â?¢ The working principles are according to IESNA and CIE. The LSG-5000/LSG-3000 are completely meet the LM-80, LM-79, LM-75, GB, EN and CIE121-1996. â?¢ Special collimation device with laser cross line, conveniently and accurately fix the position of the tested luminaries. Specifications: â?¢ The tested luminaire rotates around the mirror with an angle of (γ) ±180° (or 0-360°) and the tested luminaire rotates around itself with an angle of (C) ±180° (or 0-360°). â?¢ The accuracy of angle: 0.05°, Resolution of angle: 0.001° â?¢ Accuracy of photo detector: Constant temperature photo detector DIN5032-6/CIE pub1. No. 69 Class L (LSG-5000) â?¢ The test result can be exported as CIE, IES, LDT and other format files. This kind of format files can be transferred by other illumination and luminaire design software such as DiaLux. â?¢ Connect to PC via USB, English version software can be run in Win7, Win8 or Win10 â?¢ LSG-5000 can be used with a USB CCD Spectrometer to test spatial CCT Distribution and other Spectral color parameters. We call this system Goniospectroradiometer (LSG-5000CCD). LSG-5000CCD Goniospectroradiometer=LSG-5000 Goniophotometer System + LPCE-2 Integrating sphere Spectroradiometer System. Please refer to the LSG-5000CCD Brochure: Model No LSG-5000B (Big Size) LSG-5000 (Standard Size) LSG-5000S/LSG-3000B (Small Size) Measure Non-Flood Lamp Φ 1600*800mm, 50kg Φ 1400*500mm, 40kg Φ 1000*460mm, 30kg Measure Flood Lamp 600*600mm, 50kg 600*600mm, 40kg 400*400mm, 30kg Measure Power (W) 600V/10A, AC/DC 600V/10A, AC/DC 600V/10A, AC/DC PS. The LSG-5000X are special size which According to customers request
LSG-1800B Lamp LED on-line Goniophotometer for LED Light Measurement Introduction: LSG-1800B Goniophotometer is high precision automatic goniophotometric instrument for luminous intensity distribution measurements with facility for turning the light source. The LSG-1800B is an update version for LSG-1800, the LSG-1800B use a constant temperature detector, Japanese Motor and Germany precision angle coder which keeps high test accuracy. It is for industrial laboratory measurements the photometric data of luminaires. Be utilized to measure photometric parameters of luminaires for LED road lighting fixture, room lighting fixture and projecting lighting fixture, such as spatial intensity distribution curve, spatial iso-intensity curve, intensity distribution curve on each section (represent by right-angled coordinates or polar coordinates, luminance limitation curve, luminaire efficiency, glare grade, effective beam angle, upward luminous flux ratio, downward luminous flux ratio, total luminous flux, effective luminous flux, utilization factor and electric parameters voltage, current, wattage, power factor and etc. The measured data meets IES standard format and can be applied for lighting design by lighting design software. The measurement system fully satisfies the requirement of lighting design work. http://www.lisungroup.com/ wooden case
Lsg-3000 moving detector goniophotometer completely meets lm-79 clause 9.3.1 requirement. The lsg-3000 is an automatic light distribution intensity 3d curve testing system for measuring light. The measuring distance is from 5m to 30m. It can measure all types of lighting sources, led or hid luminaires such as indoor and outdoor luminaires, roadway luminaires, street lamps, flood lights and other kinds of luminaires.
Our product are use in chips.
All types of chemicals.
Corn, wheat, barley.
Precious stomes
.Import & export agent
.B2B trade marketing place
Product Description LSRF-3 Lamp start, Run-up time and Light Flickering Analyzer - Flicker Tester is equipped with Class A fast photometric probe, so the sampling speed is up to 100kHz. It fully meets the requirement of BASIC, Energy Star V2.1, IEC TR 61547-1:2020 IEC-Pst, CA CEC, ASSIST, CIE TN006-2016 CIE SVM, IEEE Std 1789 standards, etc. It is professional for flicker test of LED lights and lamps, energy-saving lamps, etc. According to EU directives 1194/2012, 2009/125 / EC, SASO2902, COMMISSION DELEGATED REGULATION (EU) 2019/2015, COMMISSION REGULATION (EU) 2019/2020 and IEC60969 "Self-ballasted Lamps for General Lighting Services-Performance Requirements" and other requirements. The LSRF-3 can connects with PC via USB cable. The English version software can be run in Win7, Win8 and Win10, Win11 (The driver was Certificated by Microsoft) Lamp Flicker test interface needs to work with LISUN Integrating Sphere, DC Power Source and Standard Light Source, it also can be added in LISUN LPCE-2 /LPCE-3 Integrating Sphere System or LSG-6000/LSG-1890B/LSG-1800A Goniophotometer or LSG-6000CCD/LSG-1890BCCD/LSG-1800ACCD Goniospectroradiometer.
LSG-6000 Moving Detector Goniophotometer Mirror Type C (updated version for LSG-5000/LSG-3000) is for LED measurement and completely meets LM-79-19 Clause 9.3.1 requirement. For candela intensity distribution, EEI, color temperature distribution and IES, LDT files measurement.
.Logistics, warehousing, transportation
Lsg-3000 moving detector goniophotometer completely meets lm-79 clause 9.3.1 requirement. The lsg-3000 is an automatic light distribution intensity 3d curve testing system for measuring light. The measuring distance is from 5m to 30m. It can measure all types of lighting sources, led or hid luminaires such as indoor and outdoor luminaires, roadway luminaires, street lamps, flood lights and other kinds of luminaires. Measurement: Luminous intensity data, luminous intensity distribution, zonal luminous flux, luminaries efficiency, luminance distribution, coefficient of utilization, luminance limitation curves glare, maximum ratio of distance to height, equal illuminance diagrams, curves of luminaires vs lighting area, lsocandela diagrams, efficient luminescence angle etc. Features: many national patents pending on hardware and software. cie class a & constant temperature photo detector (class l detector can be optional). high degree of intelligent and test function is complete. the rotation motor is from japan mitsubishi motors and it uses germanic angle decode system, it will help smoothly and high accuracy rotation. It is very stable when start and stop. the working principles are according to iesna and cie. This instrument is specially recommended by lm-75, lm-79 and cie121-1996. with some optional instruments, it has good expanding functions the position and working state remain the same as it is under working. special collimation device with laser cross line, conveniently and accurately fix the position of the tested luminaries. Wooden case
Agriculture Product, Wooden, Craft..
Sofas and dining sets.
Measurement: Luminous Intensity Data, Photometric Data, Luminous Intensity Distribution, Zonal Luminous Flux, Luminaries Efficiency, Luminance Distribution(Option), Coefficient Of Utilization, Luminance Limitation Curves Glare, Maximum Ratio of Distance to Height, Equal Illuminance Diagrams, Curves of Luminaires VS Lighting Area, Isocandela Diagrams, Efficient Luminescence Angle, EEI, UGR, etc. Features: he near field detector moves together with the big mirror in a line. The big mirror and the far field detector move synchronously.The burning position of the lumainares will be kept without moving at all, and the detector will always sense the light directly from the luminares. The rotary motor is from Japan MITSUBISHI MOTORS and the angle decode system is from Germany. They help the goniophotometer rotating smoothly with high accuracy. It is very stable when start and stop. The working principles are according to IESNA and CIE. The LSG-6000 completely meet the LM-80, LM-79, LM-75, GB, EN and CIE121-1996 standards. Special collimation device with cross laser line help you installing the position of the luminaires under test conveniently and accurately. Specifications: The mirror and detector rotates around the luminaire under test with an angle of () vertical axis ±180 (or 0-360) and the luminaire rotates around itself with an angle of (C) horizontal axis ±180 (or 0-360 ). The accuracy of angle: 0.05, Resolution of angle: 0.001 Accuracy of Goniophotometry detector: Constant temperature photo detector DIN5032-6/CIE pub1. No. 69 Class L LISUN goniophotometer software can export CIE, IES, LDT and other format files. These kinds of format files can be used via other illumination and luminaire design software such as DiaLux. Connect the goniophotometer to PC via USB cable. English version software can run on Win7, Win8 or Win10, Win11 LSG-6000 can be used together with a CCD Spectroradiometer to test spatial CCT Distribution and other Spectral color parameters. We call this system Goniospectroradiometer (LSG-6000CCD)â??. LSG-6000CCD Goniospectroradiometer = LSG-6000 Goniophotometer System + LPCE-2 Integrating sphere Spectroradiometer System. Please click to download the LSG-6000CCD Brochure The LSG-6000CCD software and hardware support the plant lighting PAR, PPF and PPFD spatial distribution test , and it can export IES/LDT files
Machinery, machine tools, machine and machinery spares.
Safety Glass testing Equipment: Portable on-site Comprehensive Measurement Instrument for Energy-saving Glass It is applicable to the field test for opt thermal parameters of energy-saving glass installed and or to be installed The data that the instrument can measure is: thermal parameters, optical parameters, light transmittance, light reflectance, shading coefficient, U value, LSG, Low-E position, E value, space thickness, overall thickness, glass thickness The types of glass that the instrument can measure are: Single pane, Laminated glass, Uncoated insulated glass, Coating on both sides and below, Coating on more than two sides, Coating on both sides and below, Coating on more than two sides, Vacuum glazing Pummel Test Device: Hammer head diameter: 30mm Impact Distance: Adjustable Shot Bag Impact Testing Frame: Shot Bag 45kg/46kg Automatic Release Electric Lifting Pneumatic Clamping PV Load Test Equipment Size: 6425mm*2000mm*3490mm Samples: 1643mm*991mm~2009mm*1027mm (Customized) Source: Sandbag Load: 2400Pa 5400Pa 8100Pa 10000Pa (Customized) Pneumatic Tyres Device Weight 50 kg ± 0.1 kg Tire pressure: 0.35Mpa ± 0.02Mpa Type: 3.50-R8 4PR Forced Entry Resistant Glass Test Device Axe: 810mm Long Axe Quality: 1.80kg Sample size: 610mm*610mm Insulating Glass Dew Point Meter Operating temperature: -80C ~ 100C Tube height: 300mm Tube diameter: 50mm Temperature resolution: 0.1 C Hard/Soft Pendulum Shock Test for Lifts Hard pendulum shock device Height: 330�± 15mm Max diameter: 240�±10mm Weight: 10kg �± 0.1kg Material: according to ISO standard Filler: 3.5mm 0.25mm Soft pendulum shock device Height: 330mm ± 15mm Maximum diameter: 240mm�±15mm Weight: 45kg ± 0.5kg Material: leather bag Filler: diameter 3.5mm ± 1mm lead sand Boiling Test Device Power: 220V 50Hz 3Kw (Customized) Outside Size: 400mm*255mm*480mm Inside Size: 400mm*255mm*480mm At most 6 samples with 300mm*300mm Tempered Glass Flatness Measuring Instrument Measurement of arcuate form and wave form of toughened glass Resolution: 0.01mm Measuring Span: 300mm-12000 mm ( Customized) Impactor for building Glass and Metal Guardrail Impact Steel ball Weight: 1040g �± 10g Dia: 63mm Shot bag impactor Data: Weight: 45kg �± 0.1kg Height: 330mm �± 13mm Max diameter: 250mm Material: leather bag filling lead shot Leather thickness: 0.15mm Lead sand size: 2.5mm Hard and Soft Body Impactors for Opaque Wall Components Soft body: Weight: 50kg Dia: 400mm Conical canvas bag filles with 3mm glass sphere Hard Body: Steel Ball 0.5 kg/50mm Steel Ball 1 kg/62.5mm