Uses Sample baking, drying and sample digestion test, is a necessary tool for geological, metallurgical, environmental protection, agriculture, grain and cooking oil, forestry, food, medical and health, biochemical and other laboratories, as well as teaching and research. Sample digestion before chemical analysis of soil, feed, plants, seeds, heavy metals, ore. It is an ideal equipment of sample pretreatment for analytical instruments such as AA, ICP, ICP-MS, and atomic fluorescence. It can also be used for pretreatment and acid removal treatment of microwave digestion. Structure Metal frame, anti-corrosion coating, silicon carbide angular beam, ceramic fiber, high-alumina combined heating plate. Features Convenient operation, fast heating, doesnt expose wires, no open fire, no fire hazards. Insulation protection, safe and reliable. Gradient temperature control, Max. Temperature 500/700 C. Can be used directly or in combination with silicon carbide plate, so that the temperature uniformity, anti-corrosion have achieved better results.
Uses Sample baking, drying and sample digestion test, is a necessary tool for geological, metallurgical, environmental protection, agriculture, grain and cooking oil, forestry, food, medical and health, biochemical and other laboratories, as well as teaching and research. Sample digestion before chemical analysis of soil, feed, plants, seeds, heavy metals, ore. It is an ideal equipment of sample pretreatment for analytical instruments such as AA, ICP, ICP-MS, and atomic fluorescence. It can also be used for pretreatment and acid removal treatment of microwave digestion. Main features 1.Corrosion resistance: Resist all kinds of acids: sulfuric acid, hydrochloric acid, nitric acid, hydrofluoric acid, perchloric acid, aqua regia and so on. Resist Alkali and a variety of corrosive gases. 2.High temperature resistance: Max. temperature 350 . (Plate temperature) 3.Temperature uniformity: The temperature difference of each point on the surface doesnt exceed 2 C. Homogeneous batches of specimens (dozens of beakers) can reach boiling point at the same time. 4.Temperature control accurate: Can adjust temperature as desired, PID adjustment, temperature control accuracy: 0.1C. 5.Fast temperature rising: the time for room temperature rising to Max. temperature doesnt exceed 40 minutes, and the mean value is 6.9 seconds/C. 6. No pollution: The plate hardness: Vickers hardness 20, density 3.02, no scratches, no dropping slags. 7. Temperature measuring by the plate: The temperature displayed by the instrument is actual temperature of the plate surface (operating temperature). 8. Two heat zones: The Max. temperature of A main heating zone is 350C , and Max. temperature of B secondary heating zone is 210C . 9. Shell material: High-quality ABS plastic wrap angle. 10. Reuse: The undamaged plate system can be reused. 11. Safety of use: Multilayer insulation protection, in case of equipment failure, the alarm will be light and sound and stop work immediately.
Uses Sample baking, drying and sample digestion test, is a necessary tool for geological, metallurgical, environmental protection, agriculture, grain and cooking oil, forestry, food, medical and health, biochemical and other laboratories, as well as teaching and research. Sample digestion before chemical analysis of soil, feed, plants, seeds, heavy metals, ore. It is an ideal equipment of sample pretreatment for analytical instruments such as AA, ICP, ICP-MS, and atomic fluorescence. It can also be used for pretreatment and acid removal treatment of microwave digestion. Main features 1.Corrosion resistance: Resist all kinds of acids: sulfuric acid, hydrochloric acid, nitric acid, hydrofluoric acid, perchloric acid, aqua regia and so on. Resist Alkali and a variety of corrosive gases. 2.High temperature resistance: Max. temperature 350 . (Plate temperature) 3.Temperature uniformity: The temperature difference of each point on the surface doesnt exceed ±2. Homogeneous batches of specimens (dozens of beakers) can reach boiling point at the same time. 4.Temperature control accurate: Can adjust temperature as desired, PID adjustment, temperature control accuracy: ±0.1. 5.Fast temperature rising: the time for room temperature rising to Max. temperature doesnt exceed 40 minutes, and the mean value is 6.9 seconds/. 6. No pollution: The plate hardness: Vickers hardness 20, density 3.02, no scratches, no dropping slags. 7. Temperature measuring by the plate: The temperature displayed by the instrument is actual temperature of the plate surface (operating temperature). 8. Two heat zones: The Max. temperature of A main heating zone is 350 , and Max. temperature of B secondary heating zone is 210 . 9. Shell material: High-quality ABS plastic wrap angle. 10. Reuse: The undamaged plate system can be reused. 11. Safety of use: Multilayer insulation protection, in case of equipment failure, the alarm will be light and sound and stop work immediately.
Uses Sample baking, drying and sample digestion test, is a necessary tool for geological, metallurgical, environmental protection, agriculture, grain and cooking oil, forestry, food, medical and health, biochemical and other laboratories, as well as teaching and research. Sample digestion before chemical analysis of soil, feed, plants, seeds, heavy metals, ore. It is an ideal equipment of sample pretreatment for analytical instruments such as AA, ICP, ICP-MS, and atomic fluorescence. It can also be used for preparation and acid steaming treatment of microwave digestion. Main features 1.Corrosion resistance: Resist all kinds of acids: sulfuric acid, hydrochloric acid, nitric acid, hydrofluoric acid, perchloric acid, aqua regia and so on. Resist Alkali and a variety of corrosive gases. 2.High temperature resistance: Max. temperature 350 . (Plate temperature) 3.Temperature uniformity: The temperature difference of each point on the surface doesnt exceed 5 C. Homogeneous batches of specimens (dozens of beakers) can reach boiling point at the same time. 4.Temperature control accurate: Can adjust temperature as desired, PID adjustment, temperature control accuracy: 0.1C. 5.Fast temperature rising: the time for room temperature rising to Max. temperature doesnt exceed 40 minutes, and the mean value is 6.9 seconds/C. 6. No pollution: The plate hardness: Vickers hardness 20, density 3.02, no scratches, no dropping slags. 7. Temperature measuring by the plate: The temperature displayed by the instrument is actual temperature of the plate surface (operating temperature). 8. Two heat zones: The Max. temperature of A main heating zone is 350C , and Max. temperature of B secondary heating zone is 210C . 9. Shell material: Metal coates high-quality ABS plastic. 10. Reuse: The undamaged plate system can be reused. 11. Safety of use: Multilayer insulation protection, in case of equipment failure, the alarm will be light and sound and stop work immediately.
Uses Sample baking, drying and sample digestion test, is a necessary tool for geological, metallurgical, environmental protection, agriculture, grain and cooking oil, forestry, food, medical and health, biochemical and other laboratories, as well as teaching and research. Sample digestion before chemical analysis of soil, feed, plants, seeds, heavy metals, ore. It is an ideal equipment of sample pretreatment for analytical instruments such as AA, ICP, ICP-MS, and atomic fluorescence. It can also be used for preparation and acid steaming treatment of microwave digestion. Structure Metal frame, anti-corrosion coating, silicon carbide angular beam, high purity alumina (HPA) combined heating plate. Features Convenient operation, fast heating, doesnt expose wires, no open fire, no fire hazards. Insulation protection, safe and reliable. Gradient temperature control, Max. Temperature 500/700 C. Can be used directly or in combination with silicon carbide plate, so that the temperature uniformity, anti-corrosion have achieved better results.
Uses Sample baking, drying and sample digestion test, is a necessary tool for geological, metallurgical, environmental protection, agriculture, grain and cooking oil, forestry, food, medical and health, biochemical and other laboratories, as well as teaching and research. Sample digestion before chemical analysis of soil, feed, plants, seeds, heavy metals, ore. It is an ideal equipment of sample pretreatment for analytical instruments such as AA, ICP, ICP-MS, and atomic fluorescence. It can also be used for preparation and acid steaming treatment of microwave digestion. Main features 1. Stereo surround heating: The design concept of five-sided heating is the real sense of stereo surround heating. 2. High efficiency of rapid digestion: large amount of sample disposal at one time, heating time is short. Compared with the general hole digestion instrument which only relies on the plane heating radiation facade, it can improve the working efficiency by 60%. 3. Digestion uniformity: the bottom of the test tube and 360 degree heating make the sample heating without blind spots, good stability and uniformity. 4. Precise temperature control: PID adjustment, temperature control accuracy (0.1 C). 5. Good thermal insulation performance: high purity alumina Mullite with high quality and environmental protection ensures the minimum heat loss. 6. Corrosion Resistance: The metal shell is coated with special anti-corrosion professional coatings, which are resistant to various corrosive liquids and gases. 7. Easy to use: The apparent temperature is the sample temperature. 8. Safety of use: Multilayer insulation protection, in case of equipment failure, the alarm will be light and sound and stop work immediately.
Uses Sample baking, drying and sample digestion test, is a necessary tool for geological, metallurgical, environmental protection, agriculture, grain and cooking oil, forestry, food, medical and health, biochemical and other laboratories, as well as teaching and research. Sample digestion before chemical analysis of soil, feed, plants, seeds, heavy metals, ore. It is an ideal equipment of sample pretreatment for analytical instruments such as AA, ICP, ICP-MS, and atomic fluorescence. It can also be used for pretreatment and acid removal treatment of microwave digestion. Main features 1. Stereo surround heating: The design concept of five-sided heating is the real sense of stereo surround heating. 2. High efficiency of rapid digestion: large amount of sample disposal at one time, heating time is short. Compared with the general hole digestion instrument which only relies on the plane heating radiation facade, it can improve the working efficiency by 60%. 3. Digestion uniformity: the bottom of the test tube and 360 degree heating make the sample heating without blind spots, good stability and uniformity. 4. Precise temperature control: PID adjustment, temperature control accuracy (0.1 C). 5. Good thermal insulation performance: high-alumina Mullite with high quality and environmental protection ensures the minimum heat loss. 6. Corrosion Resistance: The metal shell is coated with special anti-corrosion professional coatings, which are resistant to various corrosive liquids and gases. 7. Easy to use: The apparent temperature is the sample temperature. 8. Safety of use: Multilayer insulation protection, in case of equipment failure, the alarm will be light and sound and stop work immediately.
Uses Sample baking, drying and sample digestion test, is a necessary tool for geological, metallurgical, environmental protection, agriculture, grain and cooking oil, forestry, food, medical and health, biochemical and other laboratories, as well as teaching and research. Sample digestion before chemical analysis of soil, feed, plants, seeds, heavy metals, ore. It is an ideal equipment of sample pretreatment for analytical instruments such as AA, ICP, ICP-MS, and atomic fluorescence. It can also be used for pretreatment and acid removal treatment of microwave digestion. Structure Metal frame, anti-corrosion coating, silicon carbide angular beam, ceramic fiber, high-alumina combined heating plate. ï?¶ Features Convenient operation, fast heating, doesnt expose wires, no open fire, no fire hazards. Insulation protection, safe and reliable. Gradient temperature control, Max. Temperature 500/700. Can be used directly or in combination with silicon carbide plate, so that the temperature uniformity, anti-corrosion have achieved better results.
Laboratory digestion & acid removal system, laboratory intelligent electric hot plate, laboratory voltage adjustable electric hot plate, sample grinder, muffle furnace, oven.
Features: 1. Transverse wind cycle structure, conducive to air mixing, high space utilization, fast drying rate. 2.Convenient operating, fixed value operating, timing operating, automatic stop. 3. The special function keys to achieve temperature setting. 4. Auxiliary menu, realized over-temperature alarm, deviation correction, menu locking. 5. Forced fan cooling intake structure, so that the maximum operating temperature of the fan doesnt exceed 50C. Long service time. 6.Corrosion resistance, furnace using high-quality anticorrosive coating. Technical parameter: Temperature Control Range: DG series: Room temperature +10~250C WG series: Room temperature +10~300C Temperature fluctuation: 1C Operating Ambient temperature: 5~50 C Security Over-temperature alarm, Menu locking
We supply attractive variety qualitative range of Toilet and Bathroom accessories. Features of our Shower door hinges · CNC machined precision pivot pins · Dimension 90mmx 55mm (varies from hinge to hinge) · Chrome plated, Brushed Nickel, Brass Polished, Polished Chrome, Gold Plated, Oil Rubbed Bronze. · Solid brass, Zinc as per customer choice. · Glass to Glass, wall to Glass shower door hinges. · Closing angles 90°, 135°,180°degree. · Straight edges, beveled edges, round edges. · Glass preparation- Mickey Mouse ear, square and round glass cut. · Glass thickness 8mm-12mm. · Glass door weight 35~36Kgs with two hinges. · Glass door weight 54Kgs with three hinges. · Also available in some models of shower door hinges with adjustable hinges. · Also available in auto- self closing for some models. · Also available in Bi-fold Hinge.
For the Mosquito killer Led Bulb Light, is a 900 lumen bulb that doubles as an insect killer. The light features a blue UV LED which attracts insects into a Mosquito Killer grid.And the Mosquito Killer grid uses only 1W of electricity, while the light itself uses a meager 9W – and both can be used independently.They are used at home and outdoor. A brush is provided to clean off insects once the bulb switched-off.Compare to other traditional mosquito killer, this bulb has no chemicals, no sprays and hence no fumes to our life. 2nd generation 2-in-1 LED LIGHT Bulb Plus LED Mosquito Killer Bulb Wattage: 10W Blue UV light Lumen: 900-1000lm Color Temperature (CCT): 6500K Input Voltage: AC 90-130V & 220v-240V With CE and ROHS Operation: Step1: Switch it on,both lighting +killing are on. Step2: Switch on again,light off,only killing on. Step3: Switch on again,killing off,only light on. Step4: Switch off, both off.
Features 1. Integrated design, lightweight and compact structure. 2.The vacuum molded polycrystalline mullite fiber furnace is high efficiency heat insulation, special alloy heating wires provide three-sided heating to ensure the best temperature uniformity. 3.Parallel side open door, so that the hot end away from the operation. 4. Once open the door, the power will be shut off. The power supplied time will be extended. Ensure the safety. 5. Double shell air heat insulation, low surface temperature. 6. Exhaust device, conducive to be ashing. 7. High-precision microcomputer control instrument and precision sensor are perfect combined, accurate temperature. 8. The special function keys to achieve temperature setting. 9.Auxiliary menu, realize over-temperature alarm, deviation correction, menu locking, over-temperature prevention device. Security Over-temperature alarm, menu locking, over-temperature prevention, open door power shut off, power supplied time extended.
Features 1.Adjustable door lock, self-suitable observation window frame, disposable molding silicone seal, to ensure long-term stable sealing. 2. PID temperature control instrument, more accurate. 3. The special function keys to achieve temperature setting. 4.Auxiliary menu, realized over-temperature alarm, deviation correction, menu locking. Technical parameter: Temperature control range: room temperature +10~250C Temperature resolution: 0.1C Constant temperature volatility: 1C Vacuum degree:133Pa Max.
Uses Sample baking, drying and sample digestion test, is a necessary tool for geological, metallurgical, environmental protection, agriculture, grain and cooking oil, forestry, food, medical and health, biochemical and other laboratories, as well as teaching and research. Sample digestion before chemical analysis of soil, feed, plants, seeds, heavy metals, ore. It is an ideal equipment of sample pretreatment for analytical instruments such as AA, ICP, ICP-MS, and atomic fluorescence. It can also be used for pretreatment and acid removal treatment of microwave digestion. Main features 1. Stereo surround heating: The design concept of five-sided heating is the real sense of stereo surround heating. 2. High efficiency of rapid digestion: large amount of sample disposal at one time, heating time is short. Compared with the general hole digestion instrument which only relies on the plane heating radiation facade, it can improve the working efficiency by 60%. 3. Digestion uniformity: the bottom of the test tube and 360 degree heating make the sample heating without blind spots, good stability and uniformity. 4. Precise temperature control: PID adjustment, temperature control accuracy (±0.1 ). 5. Good thermal insulation performance: high-alumina Mullite with high quality and environmental protection ensures the minimum heat loss. 6. Corrosion Resistance: The metal shell is coated with special anti-corrosion professional coatings, which are resistant to various corrosive liquids and gases. 7. Easy to use: The apparent temperature is the sample temperature. 8. Safety of use: Multilayer insulation protection, in case of equipment failure, the alarm will be light and sound and stop work immediately.
Features 1. Integrated design, lightweight and compact structure. 2.The vacuum molded polycrystalline mullite fiber furnace is high efficiency heat insulation, special alloy heating wires provide three-sided heating to ensure the best temperature uniformity. 3.Parallel side open door, so that the hot end away from the operation. 4. Once open the door, the power will be shut off. The power supplied time will be extended. Ensure the safety. 5. Double shell air heat insulation, low surface temperature. 6. Exhaust device, conducive to be ashing. 7. High-precision microcomputer control instrument and precision sensor are perfect combined, accurate temperature. 8. The special function keys to achieve temperature setting. 9.Auxiliary menu, realize over-temperature alarm, deviation correction, menu locking, over-temperature prevention device. Security Over-temperature alarm, menu locking, over-temperature prevention, open door power shut off, power supplied time extended.
Features: 1. Transverse wind cycle structure, conducive to air mixing, high space utilization, fast drying rate. 2.Convenient operating, fixed value operating, timing operating, automatic stop. 3. The special function keys to achieve temperature setting. 4. Auxiliary menu, realized over-temperature alarm, deviation correction, menu locking. 5. Forced fan cooling intake structure, so that the maximum operating temperature of the fan doesnt exceed 50. Long service time. 6.Corrosion resistance, furnace using high-quality anticorrosive coating. Technical parameter: Temperature Control Range: DG series: Room temperature +10~250 WG series: Room temperature +10~300 Temperature fluctuation: ±1 Operating Ambient temperature: 5~50 Security Over-temperature alarm, Menu locking
Features 1.Adjustable door lock, self-suitable observation window frame, disposable molding silicone seal, to ensure long-term stable sealing. 2. PID temperature control instrument, more accurate. 3. The special function keys to achieve temperature setting. 4.Auxiliary menu, realized over-temperature alarm, deviation correction, menu locking. Technical parameter: Temperature control range: room temperature +10~250 Temperature resolution: 0.1 Constant temperature volatility: ±1 Vacuum degree:
Mill scale, is formed on the outer surfaces of plates, sheets or profiles when they are being produced by rolling hot iron or steel billets in rolling or steel mills. It looks like a hard brittle sand and is mainly composed of iron oxides, mostly ferric, and is bluish black in color. Being produced during the reheating, conditioning and hot rolling operation for the production of steel articles, the mill scale initially adheres to the steel surface and protects it from atmospheric corrosion, provided no break occurs in this coating. From the chemical and physical analysis performed on the scrap, and according to the european environmental rules, the material has been classified as a special non dangerous waste, listed in green list In particular the mill scale can be classified as follows: Einecs (european commission no.): 266-007-8 Waste code: 10 02 10 Basel code: b 12 30 Hs code: 2619.00
We hold immense expertise in making available Copper in many forms including LME registered and non registered cathodes, billets, rods, cakes, bars, foil, sheet, granules, plates, powder, shot, turnings, wire, insulated wire, mesh and “evaporation slugs”. Copper is one of the most important metals. Copper is reddish with a bright metallic lustre. It is malleable, ductile, and a good conductor of heat and electricity (second only to silver in electrical conductivity). Its alloys, brass and bronze, are very important. Monel and gun metals also contain copper. The most important compounds are the oxide and the sulphate, (blue vitriol