Uses Sample baking, drying and sample digestion test, is a necessary tool for geological, metallurgical, environmental protection, agriculture, grain and cooking oil, forestry, food, medical and health, biochemical and other laboratories, as well as teaching and research. Sample digestion before chemical analysis of soil, feed, plants, seeds, heavy metals, ore. It is an ideal equipment of sample pretreatment for analytical instruments such as AA, ICP, ICP-MS, and atomic fluorescence. It can also be used for pretreatment and acid removal treatment of microwave digestion. Main features 1.Corrosion resistance: Resist all kinds of acids: sulfuric acid, hydrochloric acid, nitric acid, hydrofluoric acid, perchloric acid, aqua regia and so on. Resist Alkali and a variety of corrosive gases. 2.High temperature resistance: Max. temperature 350 . (Plate temperature) 3.Temperature uniformity: The temperature difference of each point on the surface doesnt exceed 2 C. Homogeneous batches of specimens (dozens of beakers) can reach boiling point at the same time. 4.Temperature control accurate: Can adjust temperature as desired, PID adjustment, temperature control accuracy: 0.1C. 5.Fast temperature rising: the time for room temperature rising to Max. temperature doesnt exceed 40 minutes, and the mean value is 6.9 seconds/C. 6. No pollution: The plate hardness: Vickers hardness 20, density 3.02, no scratches, no dropping slags. 7. Temperature measuring by the plate: The temperature displayed by the instrument is actual temperature of the plate surface (operating temperature). 8. Two heat zones: The Max. temperature of A main heating zone is 350C , and Max. temperature of B secondary heating zone is 210C . 9. Shell material: High-quality ABS plastic wrap angle. 10. Reuse: The undamaged plate system can be reused. 11. Safety of use: Multilayer insulation protection, in case of equipment failure, the alarm will be light and sound and stop work immediately.
Uses Sample baking, drying and sample digestion test, is a necessary tool for geological, metallurgical, environmental protection, agriculture, grain and cooking oil, forestry, food, medical and health, biochemical and other laboratories, as well as teaching and research. Sample digestion before chemical analysis of soil, feed, plants, seeds, heavy metals, ore. It is an ideal equipment of sample pretreatment for analytical instruments such as AA, ICP, ICP-MS, and atomic fluorescence. It can also be used for pretreatment and acid removal treatment of microwave digestion. Main features 1.Corrosion resistance: Resist all kinds of acids: sulfuric acid, hydrochloric acid, nitric acid, hydrofluoric acid, perchloric acid, aqua regia and so on. Resist Alkali and a variety of corrosive gases. 2.High temperature resistance: Max. temperature 350 . (Plate temperature) 3.Temperature uniformity: The temperature difference of each point on the surface doesnt exceed ±2. Homogeneous batches of specimens (dozens of beakers) can reach boiling point at the same time. 4.Temperature control accurate: Can adjust temperature as desired, PID adjustment, temperature control accuracy: ±0.1. 5.Fast temperature rising: the time for room temperature rising to Max. temperature doesnt exceed 40 minutes, and the mean value is 6.9 seconds/. 6. No pollution: The plate hardness: Vickers hardness 20, density 3.02, no scratches, no dropping slags. 7. Temperature measuring by the plate: The temperature displayed by the instrument is actual temperature of the plate surface (operating temperature). 8. Two heat zones: The Max. temperature of A main heating zone is 350 , and Max. temperature of B secondary heating zone is 210 . 9. Shell material: High-quality ABS plastic wrap angle. 10. Reuse: The undamaged plate system can be reused. 11. Safety of use: Multilayer insulation protection, in case of equipment failure, the alarm will be light and sound and stop work immediately.
Uses Sample baking, drying and sample digestion test, is a necessary tool for geological, metallurgical, environmental protection, agriculture, grain and cooking oil, forestry, food, medical and health, biochemical and other laboratories, as well as teaching and research. Sample digestion before chemical analysis of soil, feed, plants, seeds, heavy metals, ore. It is an ideal equipment of sample pretreatment for analytical instruments such as AA, ICP, ICP-MS, and atomic fluorescence. It can also be used for preparation and acid steaming treatment of microwave digestion. Main features 1.Corrosion resistance: Resist all kinds of acids: sulfuric acid, hydrochloric acid, nitric acid, hydrofluoric acid, perchloric acid, aqua regia and so on. Resist Alkali and a variety of corrosive gases. 2.High temperature resistance: Max. temperature 350 . (Plate temperature) 3.Temperature uniformity: The temperature difference of each point on the surface doesnt exceed 5 C. Homogeneous batches of specimens (dozens of beakers) can reach boiling point at the same time. 4.Temperature control accurate: Can adjust temperature as desired, PID adjustment, temperature control accuracy: 0.1C. 5.Fast temperature rising: the time for room temperature rising to Max. temperature doesnt exceed 40 minutes, and the mean value is 6.9 seconds/C. 6. No pollution: The plate hardness: Vickers hardness 20, density 3.02, no scratches, no dropping slags. 7. Temperature measuring by the plate: The temperature displayed by the instrument is actual temperature of the plate surface (operating temperature). 8. Two heat zones: The Max. temperature of A main heating zone is 350C , and Max. temperature of B secondary heating zone is 210C . 9. Shell material: Metal coates high-quality ABS plastic. 10. Reuse: The undamaged plate system can be reused. 11. Safety of use: Multilayer insulation protection, in case of equipment failure, the alarm will be light and sound and stop work immediately.
Uses Sample baking, drying and sample digestion test, is a necessary tool for geological, metallurgical, environmental protection, agriculture, grain and cooking oil, forestry, food, medical and health, biochemical and other laboratories, as well as teaching and research. Sample digestion before chemical analysis of soil, feed, plants, seeds, heavy metals, ore. It is an ideal equipment of sample pretreatment for analytical instruments such as AA, ICP, ICP-MS, and atomic fluorescence. It can also be used for preparation and acid steaming treatment of microwave digestion. Structure Metal frame, anti-corrosion coating, silicon carbide angular beam, high purity alumina (HPA) combined heating plate. Features Convenient operation, fast heating, doesnt expose wires, no open fire, no fire hazards. Insulation protection, safe and reliable. Gradient temperature control, Max. Temperature 500/700 C. Can be used directly or in combination with silicon carbide plate, so that the temperature uniformity, anti-corrosion have achieved better results.
Uses Sample baking, drying and sample digestion test, is a necessary tool for geological, metallurgical, environmental protection, agriculture, grain and cooking oil, forestry, food, medical and health, biochemical and other laboratories, as well as teaching and research. Sample digestion before chemical analysis of soil, feed, plants, seeds, heavy metals, ore. It is an ideal equipment of sample pretreatment for analytical instruments such as AA, ICP, ICP-MS, and atomic fluorescence. It can also be used for pretreatment and acid removal treatment of microwave digestion. Structure Metal frame, anti-corrosion coating, silicon carbide angular beam, ceramic fiber, high-alumina combined heating plate. Features Convenient operation, fast heating, doesnt expose wires, no open fire, no fire hazards. Insulation protection, safe and reliable. Gradient temperature control, Max. Temperature 500/700 C. Can be used directly or in combination with silicon carbide plate, so that the temperature uniformity, anti-corrosion have achieved better results.
Uses Sample baking, drying and sample digestion test, is a necessary tool for geological, metallurgical, environmental protection, agriculture, grain and cooking oil, forestry, food, medical and health, biochemical and other laboratories, as well as teaching and research. Sample digestion before chemical analysis of soil, feed, plants, seeds, heavy metals, ore. It is an ideal equipment of sample pretreatment for analytical instruments such as AA, ICP, ICP-MS, and atomic fluorescence. It can also be used for preparation and acid steaming treatment of microwave digestion. Main features 1. Stereo surround heating: The design concept of five-sided heating is the real sense of stereo surround heating. 2. High efficiency of rapid digestion: large amount of sample disposal at one time, heating time is short. Compared with the general hole digestion instrument which only relies on the plane heating radiation facade, it can improve the working efficiency by 60%. 3. Digestion uniformity: the bottom of the test tube and 360 degree heating make the sample heating without blind spots, good stability and uniformity. 4. Precise temperature control: PID adjustment, temperature control accuracy (0.1 C). 5. Good thermal insulation performance: high purity alumina Mullite with high quality and environmental protection ensures the minimum heat loss. 6. Corrosion Resistance: The metal shell is coated with special anti-corrosion professional coatings, which are resistant to various corrosive liquids and gases. 7. Easy to use: The apparent temperature is the sample temperature. 8. Safety of use: Multilayer insulation protection, in case of equipment failure, the alarm will be light and sound and stop work immediately.
Uses Sample baking, drying and sample digestion test, is a necessary tool for geological, metallurgical, environmental protection, agriculture, grain and cooking oil, forestry, food, medical and health, biochemical and other laboratories, as well as teaching and research. Sample digestion before chemical analysis of soil, feed, plants, seeds, heavy metals, ore. It is an ideal equipment of sample pretreatment for analytical instruments such as AA, ICP, ICP-MS, and atomic fluorescence. It can also be used for pretreatment and acid removal treatment of microwave digestion. Main features 1. Stereo surround heating: The design concept of five-sided heating is the real sense of stereo surround heating. 2. High efficiency of rapid digestion: large amount of sample disposal at one time, heating time is short. Compared with the general hole digestion instrument which only relies on the plane heating radiation facade, it can improve the working efficiency by 60%. 3. Digestion uniformity: the bottom of the test tube and 360 degree heating make the sample heating without blind spots, good stability and uniformity. 4. Precise temperature control: PID adjustment, temperature control accuracy (0.1 C). 5. Good thermal insulation performance: high-alumina Mullite with high quality and environmental protection ensures the minimum heat loss. 6. Corrosion Resistance: The metal shell is coated with special anti-corrosion professional coatings, which are resistant to various corrosive liquids and gases. 7. Easy to use: The apparent temperature is the sample temperature. 8. Safety of use: Multilayer insulation protection, in case of equipment failure, the alarm will be light and sound and stop work immediately.
Uses Sample baking, drying and sample digestion test, is a necessary tool for geological, metallurgical, environmental protection, agriculture, grain and cooking oil, forestry, food, medical and health, biochemical and other laboratories, as well as teaching and research. Sample digestion before chemical analysis of soil, feed, plants, seeds, heavy metals, ore. It is an ideal equipment of sample pretreatment for analytical instruments such as AA, ICP, ICP-MS, and atomic fluorescence. It can also be used for pretreatment and acid removal treatment of microwave digestion. Structure Metal frame, anti-corrosion coating, silicon carbide angular beam, ceramic fiber, high-alumina combined heating plate. ï?¶ Features Convenient operation, fast heating, doesnt expose wires, no open fire, no fire hazards. Insulation protection, safe and reliable. Gradient temperature control, Max. Temperature 500/700. Can be used directly or in combination with silicon carbide plate, so that the temperature uniformity, anti-corrosion have achieved better results.
Laboratory digestion & acid removal system, laboratory intelligent electric hot plate, laboratory voltage adjustable electric hot plate, sample grinder, muffle furnace, oven.
Features: 1. Transverse wind cycle structure, conducive to air mixing, high space utilization, fast drying rate. 2.Convenient operating, fixed value operating, timing operating, automatic stop. 3. The special function keys to achieve temperature setting. 4. Auxiliary menu, realized over-temperature alarm, deviation correction, menu locking. 5. Forced fan cooling intake structure, so that the maximum operating temperature of the fan doesnt exceed 50C. Long service time. 6.Corrosion resistance, furnace using high-quality anticorrosive coating. Technical parameter: Temperature Control Range: DG series: Room temperature +10~250C WG series: Room temperature +10~300C Temperature fluctuation: 1C Operating Ambient temperature: 5~50 C Security Over-temperature alarm, Menu locking
Uses Sample baking, drying and sample digestion test, is a necessary tool for geological, metallurgical, environmental protection, agriculture, grain and cooking oil, forestry, food, medical and health, biochemical and other laboratories, as well as teaching and research. Sample digestion before chemical analysis of soil, feed, plants, seeds, heavy metals, ore. It is an ideal equipment of sample pretreatment for analytical instruments such as AA, ICP, ICP-MS, and atomic fluorescence. It can also be used for pretreatment and acid removal treatment of microwave digestion. Main features 1. Stereo surround heating: The design concept of five-sided heating is the real sense of stereo surround heating. 2. High efficiency of rapid digestion: large amount of sample disposal at one time, heating time is short. Compared with the general hole digestion instrument which only relies on the plane heating radiation facade, it can improve the working efficiency by 60%. 3. Digestion uniformity: the bottom of the test tube and 360 degree heating make the sample heating without blind spots, good stability and uniformity. 4. Precise temperature control: PID adjustment, temperature control accuracy (±0.1 ). 5. Good thermal insulation performance: high-alumina Mullite with high quality and environmental protection ensures the minimum heat loss. 6. Corrosion Resistance: The metal shell is coated with special anti-corrosion professional coatings, which are resistant to various corrosive liquids and gases. 7. Easy to use: The apparent temperature is the sample temperature. 8. Safety of use: Multilayer insulation protection, in case of equipment failure, the alarm will be light and sound and stop work immediately.
1)Easy to clean, hardly destroy and color change 2 Thermal efficiency is over 90% 3)Ultra wide voltage: 110V-220V 4 Auto-inspection safety system, with child lock safety device, 5) not select the pan,it apply for glass,porcelain pan,etc. 6)Environmental protection,without radiation Products size : 290x255x55mm products weight: N.W.:2.25kg, G.W: 2.6kg Shipping Details: 6Pcs/Ctn,Export English Color Box
1) Max Power: Left 2000w Right 1800w 2) Easy to clean, hardly destroy and color change 3)Two plates can cook at the same time 4) Thermal efficiency is over 90% 5) Ultra wide voltage: 110V-220V 6) Auto-inspection safety system, with child lock safety device, 7)Do not select the pan.It can apply for glass,procelain,steel pan.etc. 8)Environmental protection,without radiation Products weight: N:5.58kg, G.W: 6.2kg Shipping Details: 5Pcs/Ctn,Export English Color Box Products size:470*320*60MM Gift Box Size: 340*720*440mm Ctn Size: 350*750*460mm 20'Container:1200pcs, 40'Container:2600 pcs, 40'HQ: 3300pcs
Electric hot plate 1). Output power:1000w 2). Voltage:220v-240v/50hz, 110v/60hz (optional) 3). Single solid hotplate; 4). Hotplate size: dia. 155mm 5). Operating on/off indicator light; 6). Auto-thermostat control; 7). Various heat operation; 8). Attention:indoor use only; 9). Colour available: white, black, silver 10). Ce approved 11). Color box packing Packing details: Meas:51.5*26*57.5cm, 12pcs/ctn Qty:20'fcl:4, 120pcs Qty:40'fcl:8, 556pcs Qty:40hq:10, 200pcs
Electric hot plate 1)output power:1000w 2)voltage:220v-240v/50hz, 110v/60hz (optional) 3)single solid hotplate; 4)hotplate size: dia. 155mm 5)operating on/off indicator light; 6)auto-thermostat control; 7)various heat operation; 8)attention:indoor use only; 9)colour available: white, black, silver 10)ce approved 11)color box packing Gift box packing
Electric hot plate )output power:1500w 2)voltage:220v-240v/50hz, 110v/60hz 3)single solid hotplate; 4)hotplate size: dia. 185mm 5)operating on/off indicator light; 6)auto-thermostat control; 7)various heat operation; 8)attention:indoor use only; 9)colour available: white, black, silver. Meas:42.5*32.5*57cm, 10pcs/ctn Qty:20fcl:3, 670pcs qty:40fcl:7, 340pcs qty:40hq:8, 860pcs
Features 1. Integrated design, lightweight and compact structure. 2.The vacuum molded polycrystalline mullite fiber furnace is high efficiency heat insulation, special alloy heating wires provide three-sided heating to ensure the best temperature uniformity. 3.Parallel side open door, so that the hot end away from the operation. 4. Once open the door, the power will be shut off. The power supplied time will be extended. Ensure the safety. 5. Double shell air heat insulation, low surface temperature. 6. Exhaust device, conducive to be ashing. 7. High-precision microcomputer control instrument and precision sensor are perfect combined, accurate temperature. 8. The special function keys to achieve temperature setting. 9.Auxiliary menu, realize over-temperature alarm, deviation correction, menu locking, over-temperature prevention device. Security Over-temperature alarm, menu locking, over-temperature prevention, open door power shut off, power supplied time extended.
Features 1.Adjustable door lock, self-suitable observation window frame, disposable molding silicone seal, to ensure long-term stable sealing. 2. PID temperature control instrument, more accurate. 3. The special function keys to achieve temperature setting. 4.Auxiliary menu, realized over-temperature alarm, deviation correction, menu locking. Technical parameter: Temperature control range: room temperature +10~250C Temperature resolution: 0.1C Constant temperature volatility: 1C Vacuum degree:133Pa Max.
Features 1. Integrated design, lightweight and compact structure. 2.The vacuum molded polycrystalline mullite fiber furnace is high efficiency heat insulation, special alloy heating wires provide three-sided heating to ensure the best temperature uniformity. 3.Parallel side open door, so that the hot end away from the operation. 4. Once open the door, the power will be shut off. The power supplied time will be extended. Ensure the safety. 5. Double shell air heat insulation, low surface temperature. 6. Exhaust device, conducive to be ashing. 7. High-precision microcomputer control instrument and precision sensor are perfect combined, accurate temperature. 8. The special function keys to achieve temperature setting. 9.Auxiliary menu, realize over-temperature alarm, deviation correction, menu locking, over-temperature prevention device. Security Over-temperature alarm, menu locking, over-temperature prevention, open door power shut off, power supplied time extended.
Features: 1. Transverse wind cycle structure, conducive to air mixing, high space utilization, fast drying rate. 2.Convenient operating, fixed value operating, timing operating, automatic stop. 3. The special function keys to achieve temperature setting. 4. Auxiliary menu, realized over-temperature alarm, deviation correction, menu locking. 5. Forced fan cooling intake structure, so that the maximum operating temperature of the fan doesnt exceed 50. Long service time. 6.Corrosion resistance, furnace using high-quality anticorrosive coating. Technical parameter: Temperature Control Range: DG series: Room temperature +10~250 WG series: Room temperature +10~300 Temperature fluctuation: ±1 Operating Ambient temperature: 5~50 Security Over-temperature alarm, Menu locking