Specification: Measurement range : So2(micro-flow ndir):0-2000 ppm No(micro-flow ndir): 0-2000 ppm Co(micro-flow ndir): 0-5000ppml O2(electrochemistry):0-25% vol Resolution: So2/no/co:1 ppm, o2: 0.01% Precision:ía2% fs Response time:ín15s Dimension:rack type 19 inch 3u Weight:approximately 10kg 3u casing
Introduction: This model is rack type can continuous monitor flue gas for longtime ; It mainly based on micro-flow infrared sensor to measure the CO,CO2,SO2,NO, especially SO2 and NO are measured by low range with 0-200ppm ;It have an analogue output (4-20mA) and digital output (RS232) ; Built-in zero pump ; The resolution is 1ppm ; Accuracy less than 2%FS ; The weight is about 12kg , it have international standard 19 inch enclosure. It usually intergrate into CEMS. Applications: Boiler, furnace exhaust emission gas and combustion efficiency monitoring, cement production line process and security monitoring, Continuous Emission Monitoring System (CEMS). Features : 1.Adopting micro-flow NDIR gas sensor technology , higher precision and life span longer . 2.Measure the lowest range of SO2 / NO are 200ppm . 3.Improve the traditional single beam gas cell to dual beam cells, no cross interference . 4.Diagnostic function could check sensor status online . 5.Sampling flow rate fluctuations had no effect on the measurement results. 6.Accurate measurement of low concentration gas. 7.Built-in zeroing pump to achieve automatic air zero . 8.Real-time continuous monitoring concentration of SO2, NO, CO, CO2, O2 , measurement component is optional . 9.LCD (320*240) display. 10.Digital and analog signal output.
FUJI developed the first infrared gas analyzer in Japan to use mass-flow sensors. Since then, we have supplied customers with various types of gas analyzers to support environmental preservation and control efforts. These efforts include measurements of atmospheric pollution and detection of low density of SOx and NOx, generated by incinerating facilities and boilers. FUJI's gas analyzers are widely used to monitor the atmosphere to help maintain a cleaner natural environment.
Gas parameter Measurement principle: Micro-flow ndir : so2, no, co, co2 Electrochemistry: o2 Measurement range : So2:0-2000ppm No: 0-2000ppm Co: 0-5000ppm Co2:0-25% O2: 0-25% Resolution: So2/no/co: 1ppm Co2/o2: 0.01% Precision: So2, no, co, co2 : 1%fs O2: 2%fs Temperature parameter Measurement principle: Ambient temperature:thermistor Flue gas temperature: thermocouple Range: Ambient temperature :-10-100íµ Flue gas temperature : -10-600íµ Resolution: Ambient temperature 1íµ Flue gas temperature 1íµ Precision: Ambient temperature ía1íµ Flue gas temperature ía2íµ Pressure parameter: Measurement principle: Diff. Pressure: silicon diff. Pressure chip Ambient pressure: silicon pressure chip Range: Diff. Pressure:-50hpa ...+50hpa Ambient pressure: 70kpa...120kpa Resolution: Diff. Pressure: 1pa Ambient pressure: 0.01kpar Precision: Diff. Pressure: ía2pa or 5%rel Ambient pressure: ía0.5 kpa or 2 % rel.
Vasthis handheld Flue gas analyzer,Model-VE5400 offers the efficiency of complete combustion optimisation all the way to comprehensive measurement and customer data management.Our Portable flue gas analyzers cover the entire measurement and documentation requirement in process and flue gas testing with instant reading. Vasthiâ??s VEA800 series is an ideal analyzer that measures 5 gases with 4 sensors. User friendly gases selection is implemented in this analyzer. This Portable Flue Gas Analyzer consists unique features.It has in-built crystal-clear touch display which enables user to view concentration values of flue gases and Bluetooth/Wi-Fi connectivity facilities.Using these facilities,Users can download the stored data as well as print it with any printer using Bluetooth / Wi-Fi User can compare daily data with charts & graphs to optimize and increase the combustion efficiency. Measuring Gases SO2,NO,CO2,NO2,Flue Gas Temperature & Temperature combustion air VASTHI will give the gases as per customer required..
Specification: Measurement range: Co:0-100% C02:0-50% Ch4:0-10% H2:0-50% O2:0-25% Precision:co/co2/ch4/:2%, o2/h2:3%(fs) Resolution:0.01% Response time:less than 20s Warm up:10min Output: 4-20ma or rs232 3u size casing
Specification: Measurement range ch4:0-100%, co2:0-50%, o2:0-25%, h2s:0-9999ppm Precision:co2/ch4:ía2%, o2:ía3%, h2s:ía4% Resolution:ch4/co2/o2:0.01% , h2s: 1 ppm Respond time:less than 20s Warm up: 10min Output: rs232 Power: ac220vía10% 50hzía1hz Weight: 10kg Dimension: rack type19 inch 3u 3u casing
Specification: Measurement range Ch4:0-100% co2:0-50% o2:0-25% h2s:0-9999ppm Precision:co2/ch4:ía2%, o2:ía3%, h2s:ía4% Resolution: ch4/co2/o2:0.01% , h2s: 1 ppm Respond time:less than 20s Warm up: 10min Output: rs232 Power: rechargeable lithium cell inside Dimension:225x172x61mm Weight: 2kg
Gas analyzer, infrared gas analyzer, infrared flue gas analyzer, infrared coal gas analyzer, biogas analyzer.
Its simple automatic operation, continuous measurement & digital display of purity concentration makes it a valuable aid for on-site instant analysis & follow up action. Its data logging & computer interface features can be used for further detailed analysis in the laboratory.The HNL Portable Model GA - 154 with digital read out and alarms is a direct reading compact Portable Gas Purity Analyzer, designed to serve the demanding field requirements of various gases Producing and using Industry. It is designed to replace the cumbersome and time consuming Or set apparatus and provide quick and accurate reading of gas Purity. It offers the user a distinct advantage in terms of economy, dependability maintenance and ease of operation. The instrument incorporate TCD / INFRARED as a transducer. It has adjustable visual and audible alarms with Automatic Zero Calibration Feature
Hydrogen Purity Analyzer: Vasthi Portable Hydrogen Purity Gas Analyzers Model VHP- 200 is a light weight, easy to handle, battery-powered analyzer, used to verify measurements and for spot-checking when other methods provide questionable results.
Hydrogen Purity Analyzer: Vasthi Portable Hydrogen Purity Gas Analyzers Model VHP- 200 is a light weight, easy to handle, battery-powered analyzer, used to verify measurements and for spot-checking when other methods provide questionable results.
Product Introduction Chromatographic analysis technology is a kind of separation and analysis technology of multi-component mixture. It mainly makes use of the difference of boiling point polarity and absorption add coefficient of each component in the sample in the chromatographic column so that each component can be separated in the chromatographic column and detect the separated components by detection apparatus so as to conduct qualitative and quantitative analysis of multi-component mixture. Because this method has a high separation efficiency fast analysis less sample consumption etc therefore has been widely used in petrochemical biochemical medicine and health food of the health and quarantine inspection of environmental protection industry in the medical clinical departments by gas chromatography in the field of solve the industrial production of intermediates and pollution detection of industrial products quality inspection scientific research production control and other issues. Chromatographic instrumentIt is a kind of high cost performance multi-function economical and practical precision instrument which adopts three-column and three-gas circuit operating system. The basic type is equipped with hydrogen flame ionization detection (FID) and thermal conductivity detection deviceï¼?TCDï¼?. Chromatographic instrumentUsing microcomputer and integrated circuit control English and Chinese interface high degree of self-motion and good reliability operating parameters keyboard setting instrument with power failure protection file storage and call function instrumentLarge screen liquid crystal displayï¼?The detection apparatus and its control assembly unit adopt plug and play control modesimplicity of operator for the instrument to conduct constant temperature and program temperature rise operation column room is equipped with flexible rear door self-motiontemperature control system the column box has excellent performance high precision temperature control quick rise and drop speed and flexible air temperature operation process Reliable easy to expand suitable for a variety of detection and sample combinations. The detector adopts the unitized combination design which is easy to install and maintain. The chromatograph can be configured with a variety of detectors (TCD FID ECD FPD and NPD). According to the user's analysis needs the chromatograph can be configured with up to four detectors at the same time. The chromatograph's injection system can be equipped with a variety of injection devices such as filling column head injection glass lining rapid injection and capillary column divided/undivided injection with diaphragm cleaning function.
Chromatographic analysis technology is a kind of separation and analysis technology of multi-component mixture. It mainly makes use of the difference of boiling point polarity and absorption add coefficient of each component in the sample in the chromatographic column so that each component can be separated in the chromatographic column and detect the separated components by detection apparatus so as to conduct qualitative and quantitative analysis of multi-component mixture. Because this method has a high separation efficiency fast analysis less sample consumption etc therefore has been widely used in petrochemical biochemical medicine and health food of the health and quarantine inspection of environmental protection industry in the medical clinical departments by gas chromatography in the field of solve the industrial production of intermediates and pollution detection of industrial products quality inspection scientific research production control and other issues. Chromatographic instrumentIt is a kind of high cost performance multi-function economical and practical precision instrument which adopts three-column and three-gas circuit operating system. The basic type is equipped with hydrogen flame ionization detection (FID) and thermal conductivity detection device TCD. Chromatographic instrument using microcomputer and integrated circuit control English and Chinese interface high degree of self-motion and good reliability operating parameters keyboard setting instrument with power failure protection file storage and call function instrument large screen liquid crystal display. The detection apparatus and its control assembly unit adopt plug and play control model simplicity of operator for the instrument to conduct constant temperature and program temperature rise operation column room is equipped with flexible rear door self-motion temperature control system the column box has excellent performance high precision temperature control quick rise and drop speed and flexible air temperature operation process Reliable easy to expand suitable for a variety of detection and sample combinations. The detector adopts the unitized combination design which is easy to install and maintain. The chromatography can be configured with a variety of detectors (TCD FID ECD FPD and NPD). According to the user's analysis needs the chromatograph can be configured with up to four detectors at the same time. The chromatograph's injection system can be equipped with a variety of injection devices such as filling column head injection glass lining rapid injection and capillary column divided/undivided injection with diaphragm cleaning function. Product nickname hydrogen generator full-automatic hydrogen generator self-motionHydrogen generator chromatographic instrument
We are the reputed supplier and importer of hga-03 headspace gas analyzer in india - contact us now to get quick quote for hga-03 headspace gas analyzer in india by labthink
We are the reputed supplier and importer of HGA-02 Headspace Gas Analyzer in India - Contact us now to Get Quick quote for HGA-02 Headspace Gas Analyzer in India by Labthink
We are the reputed supplier and importer of classic 650 headspace gas analyzer in india - contact us now to get quick quote for classic 650 headspace gas analyzer in india by labthink.
Diesel vehicle exhaust gas analyzer (can also be used in gasoline vehicle), belong to customized products, non standard. Increase the reverse blowing system and filtering, purifying device. Can be used for the detection and analysis of diesel oil as fuel of vehicle exhaust emissions group points. ã??Main technical parametersã?? exhaust gas analyzer measuring range COï¼?0ï½?10.0 10-2(%) CO2ï¼?0ï½?20.0 10-2(%) HCï¼?0ï½?9999 10-6(ppm) O2ï¼?0ï½?25.0 10-2(%) NOï¼?0ï½?5000 10-6(ppm) oil temperatureï¼?18ï½?150 speedï¼?100ï½?20000rpm resolving power COï¼?0.01% CO2ï¼?0.1% HCï¼?1ppmO2ï¼?0.01% NOï¼?1ppm oil temperatureï¼?0.1 speedï¼?1rpm Repetitive error â?¤±2% Zero drift COï¼?±0.06 10-2(%)/4h CO2ï¼?±0.5 10-2(%)/4h HCï¼?±30 10-6(ppm)/4h O2ï¼?±0.5 10-2(%)/4h NOï¼?±30 10-6(ppm)/4h Distance drift No more than shown value error allowed (4 hours) Indication error COï¼?±5%ï¼?absolute errorï¼?±0.03 10-2 ï¼? CO2ï¼?±5%ï¼?absolute errorï¼?±0.5 10-2ï¼? HCï¼?±5%ï¼?absolute errorï¼?±10 10-6 ï¼?±5%ï¼?absolute errorï¼?4001ï½?10000ppmï¼? O2ï¼?±5%ï¼?absolute errorï¼?±0.1 10-2ï¼? NOï¼?±4%ï¼?absolute errorï¼?±25 10-6ï¼? environment condition oil temperatureï¼?±2ï¼?relative errorï¼? speedï¼?±1.0%ï¼?relative errorï¼? temperatureï¼?0ï½?40 humidityï¼?â?¤80% atmospheric pressureï¼?60ï½?105KPa Power Supplyï¼?AC 220V±10%ï¼?50Hz±1Hz(Automobile power supply inverter) Preheating time 10min Weight Measurement unitï¼?10Kg vice machineï¼?3Kg Volume Measurement unitï¼?610 * 500 * 330mm Auxiliary machine:500 * 350 * 330mm Sampling method Exhaust gas: direct sampling, sampling tube length 5m, sampling probe length 900mm; Temperature: the temperature measuring head into the engine lubrication oil scale hole, insert the oil rod and the length of the same length, rubber stopper blocked, to prevent oil jet and wire length: 5m; Speed: the tachometer speed clip in high pressure flexible gasoline engine, can determine the speed of a gasoline engine. Display mode LCD large screen liquid crystal display major function 1)Meet GB18285-2005 national standard requirements, measurement of motor vehicle gasoline engine emissions of HC, CO, CO2, O2 and NO concentrations,Of HC, Co, CO2, the advanced NDIR regardless of light and infrared analysis technology (imported from movement detection equipment to meet the requirements of national standard OIMLR99 0 level precision, high precision, strong stability) and of O2 and no by the new electrochemical analysis technology for detection. 2)With idle speed, double idle test function; 3)Auto calculation shows that the excess air coefficient isï¼? 4)Equipped with RS-232C digital serial communication interface, convenient networkingï¼? 5)Matching speed and temperature measurement functionï¼?
the Berrcom JXB-178 is a non-contact infrared thermometer produced by Berrcom, a company specializing in healthcare and wellness products. Non-contact infrared thermometers are widely used for measuring body temperature without direct contact with the skin, making them particularly useful in situations where hygiene and quick readings are essential. Key features of the Berrcom JXB-178 non-contact infrared thermometer may include: Non-Contact Measurement: The thermometer is designed to measure body temperature without touching the skin, reducing the risk of cross-contamination. Infrared Technology: It uses infrared technology to detect the heat emitted by the body, providing a quick and accurate temperature reading. Backlit Display: The thermometer typically has a backlit display that allows for easy reading of temperature values, even in low-light conditions. Memory Function: Some models may include a memory function to store and recall previous temperature readings. Fever Alarm: Many non-contact infrared thermometers, including the Berrcom JXB-178, may feature a fever alarm to alert the user when a high temperature is detected. Multiple Measurement Modes: Some models offer the option to measure not only body temperature but also the temperature of surfaces and liquids.