Mini Holter recorders 3 to 12 leads, 4 to 10 electrodes, recordings up to 8 days, sampling rates of 1024 to 4096 S/s, Phone ECG Transmission of symptomatic and asymptomatic ECG events. Easy Editing of multi-day recordings into one editing file with possibility of printing one report for all days or one report a day Holter analysis of arrythmias (VEs, SVEs, Bigeminy, Trigeminy, Pairs, Runs, V-Tach, Min HR, Max HR), ST, Pauses, QT/QTc, Bundle Branch Blocks. 24h ECG full disclosure scanning with colour coded events for immediate visual verification. 24h Histograms of HR, ST, QT/QTC, VE, SVE, Pauses, and SDNN. Patient Event Monitoring with 3 or 12-Lead ECG strips print outs (XYZ). QT/QTc Analysis Validation Program Atrial Fibrillation / Flutter Detection and Editing menu Time Domain and Spectral Heart Rate Variability 3/12-Lead ST Analysis with 3D graph and FCGCADgram (CAD location Graph) Late Potentials SAECG, VectorCardioGraphy Holter Analysis of Pacemaker Recordings Sleep Apnea Monitoring with detection of SAS episodes T-Wave Alternans analysis (T-Wave Alternans) Satellite Holter Program for Remote scanning of Holter ECG Recordings Customized Reports with custom conclusions format and Header Logo Functions ¡®E-mail, ¡°PDF Output¡±, ¡®ASCII Output, Export, Dicom and HL7 interfaces Windows 72000, NT, XP, Vista compatible. Dimension: 22cm*16cm*8cm Weight: 1kg/set.
holter ECG lead cable
Functional: Channels: 3 or 8 Channel Digital Recording Resolution: 8, 10, 12, or 16 Bit Sampling Recording: Full Disclosure, No Data Compression Data Transfer: USB Cable or Flash Card Reader Sample Rate: 128-1024 Samples Per Second Frequency Response: 0.05Hz to 60Hz @ -3db ECG Signal Verification: LCD at Hook-up or on Demand Pacemaker Detection: 2.0mv~200mv 0.1ms~2.0ms. Memory: Recording Time: 24H, 48H, 72H, 96H and 7 days Type: Nonvolatile, SD Card Capacity: Up to 2048 MB (Removable). Physical: Dimensions: 2.682.080.63 (68mm,53mm,16mm) Weight: 1.48oz (42 grams excluding battery) Enclosure: Molded Plastic / Water Resistant Operating Position: Belt Clip, Lanyard. Plastic case.
Suitable for ge maruqutter, 8000 8200 8500, seer.And seer mc; dms, roxinn .Spacelabs .Ela medical . Model:holter 8448.Landcom model , holter star.
Holter ecg cable Suitable for ge maruqutter, 8000 8200 8500, seer.And seer mc; dms, roxinn .Spacelabs .Ela medical . Model:holter 8448.Landcom model , holter star.
Brand Name :PERLINK Model Number :EA063S33I Certification :CE/RoHS Place of Origin :SHENZHEN MOQ :2 PCS Price :USD 1-6 PCS Payment Terms :T/T Supply Ability :500 PCS/WEEK Delivery Time :3-5 days Packaging Details :PE series :One-Piece PERLINK's professional services: manufacturing all kinds of wire assembly, focusing on medical wire (for medical surgery and nursing testing equipment), supplemented by OEM line assembly, and ODM as the direction to meet the overall operation of the modern market. PERLINK's mission: to produce high-quality products and on-time delivery with modern production technology to match the overall operation of customers. PERLINK expects our customers to provide valuable suggestions for improvement. Our company will continue to improve the deficiencies according to the opinions of customers, and strive to meet the higher requirements of customers, so as to provide higher quality products and excellent services to satisfy customers. http://www.perlink-tech.com/
ECG Holter System (3 channel / 12 channel ) The system is a recording device and automatic analysis software system, to continuously monitor the dynamic ECG changes of human body during 24 hours. For the patiens with the symptom of palpitation, dizziness or fainting, 24-hour dynamic ECG monitoring is the major inspection means of arrhythmia clinical diagnosis, such as, extreme bradycardia, heart arrest, conduction block and ventricular tachycardia and etc. , is also one of standardized methods of monitoring myocardial ischemia.
Analyzing software features 1. Multi-windows operation 2. 46 different types arrhythmia analysis 3. Demix morphologies 4. Check sinus node recovery time 5. Check parasystole 6. Check accelerate escape rhythm 7. Check reciprocal beat 8. T wave alterans 9. Heart rate variability 10. Hrt (heart rate turbulence) 11. Sleep apnea analysis 12. Intellectual analysis of various tachycardia 13. Display start and end point of arrhythmia on same screen 14. Beat to beat analysis, no missing beats 15. 26 types histogram analysis 16. Pacemaker analysis can label 7 types shapes 17. St-t analysis Recorder features *1.77 inch color lcd, displays three leads ecg for each screen *high resolution make it is convenient to observe p or q wave and other micro-signal. Lcd screen display ecg grid to facilitate physician to watch ecg waves, count hr and other parameter *skin resistance measurement can evaluate the connection between electrode and patient skin *can freeze the ecg strip in the screen to observe it in detail *battery estimate in case of non-record by low power *holter information browser to display the start time and duration of current recording *speed: 25mm/s, gain: 5mm/mv for lcd screen display *no operation within two minutes, the screen will be auto-off to save power. And button can be locked automatically in case of misoperation *event button can make mark for symptom *the cable socket is mis-plug and break-off proof design. Recorder specification A) holter recorder power: dc 3.0v; B) recording time: 24 hours; C) recording mode: continuous; D) sample rate: 4000hz; E) standard sensitivity: 10mm/mv (-5%, +5%); F) input circuit current: ín0.1ª8a; G) input impedance: >=2.5 m? ; H) noise electric level:
Comprehensive and accurate analysis capabilities f¦c fully holter analysis The analysis is highly flexible and accurate and the report is comprehensive. Besides, it can offer replay and holter analysis for any nursing or ecg of any storage data. 1.Arrhythmia analysis (analysis of heart rate, st-segment analysis, etc.): it can analysis any 24-hour ecg, st segment, a tendency graph of heart chamber, the minimum and the maximal heart rate ecg, as many as 50 self-selected ecgs. 2.Heart rate variability analysis: 24-hour heart rate variability in the data tables, sdnn trends, rr interval histogram, rr interval and a half of the histogram, color gradient shown scatter, the difference plot, 24-hour spectral analysis chart 3.Analysis at a glance: print report to preview, which covers almost all the analysis results, including patient information and advice columns of the doctor, and the doctor can also report on the analysis required by microsoft excel format for storage, to facilitate the work of the hospital statistics Simple and efficient mode of operation Software perfectly reflects the application value of the modern computer technology in the medical field, which to the most widely used windows system as the operating platform, just use the mouse to complete almost all of the operations. Simple and quick, bring a great convenience to the operator. 1.In the monitor of the interface, just press right mouse button you can see all the functions can operate at present. 2.In the analysis of the interface, from left to right, you can get all the operations and analytical reports 3.All chinese operation interface 4.Can print everywhere Intuitive, accurate, flexible, vivid guardianship interface 1.Here are four and eight guardianship pattern that is flexible. 2.Personalized color: graphic background, users can design their own with the revision. Wireless telemetry network: 1. Single-and double-in the same, analog and digital options. 2. Prescribed as a single antenna telemetry from 30 meters (radius), the receiving antenna can be expanded by increasing the distance to ward. 3. Specialized anti-jamming circuit design, in any case records high-quality ECG shape. 4. Two 5th alkaline batteries can work continuously more than 72 hours of, the average failure-free operation time is more than 10,000 hours. Application Environment: 1. Unique: Both real-time wireless telemetry and patients may wish to normal life, in the discharge of the patient before normal life simulation Monitoring and Observation, with irreplaceable advantages of Holter monitor. 2. Extensive: This system is not only a clinical monitoring functions and with Holter analysis function, which can be widely used in ICU, CCU, cadres wards, nurses stations, first-aid centre need to monitor patients with ECG information site.
ECG cables also referred to as an ECG patient cable, is a type of cable connection designed for non-invasive heart monitoring, typically used to help diagnose potential heart issues. The ECG cable connects to electrodes which are positioned at specific locations on the patientâ??s body to detect and record heart muscle electrical activity. The cables then transmit the electrical activity back to the ECG device for analysis and diagnosis by medical professionals. ECG Cable Feature [Multiple Leads]: ECG cables usually have several leads placed in specific areas on the patientâ??s body, such as the chest, arms, and legs, to measure the heartâ??s electrical activity from different angles. [Durability]: ECG cables are constructed from top-quality, sturdy materials that can endure repeated bending, tugging, and twisting without sustaining any damage. This ensures that the cables can withstand the rigors of frequent use and remain reliable over time. [Shielding]: ECG cables are shielded to block out external electrical signals, which can interfere with the accuracy of the readings. [Connector Compatibility]: The ECG cables are available with various connector types, including snap, clip, and banana, to fit different types of ECG machines. [Safety]: ECG cables are designed to meet strict safety standards and regulations to ensure patient safety. This helps to ensure that patients are protected from any potential harm during the monitoring process. [Cleaning and Disinfecting]: The ECG cables are easy to clean and disinfect to maintain hygienic conditions, as they come into contact with the patientâ??s skin. ECG Cable Advantages [Excellent Performance]: ECG cables are built to withstand the rigors of twisting and bending, and have been thoroughly tested to ensure optimal performance. The cables are also equipped with electrical shielding to protect the signal integrity, ensuring accurate readings. [Non-Invasive]: ECG cables are non-invasive, which means that they do not require any incisions or invasive procedures. This reduces the risk of infection and makes the monitoring process much safer for patients. Instead, the cables are simply attached to the patient's skin, making it a quick and painless process.
Specification: 1. Sample rate: 1000Hz, simultaneous 12 leads recording 2. Resolution:12bit 3. Power: 5.0V (DC) 4. Patient Insulation: 4000V AC 5. Defibrillation Protection: Built-in box 6. Digital resolution: 2ª¦V 7. Frequency response: 0.05-250 Hz 8. Common mode rejection: >90dB 9. Input impedance: >10Mª+ 10. Time constant: í¦3.2 s 11. Max electrode potential: í+300mV DC 12. Dynamic range: í+10mV 13. Isolate voltage: 4000V 14. Current leak:
Holter ECG, holter recorder & holter software.
Software+blue tooth hardware + treadmill + Medical Cart + ECG Cable etc accessories Higher Sampling Rate (4096 Hz) and Superior Resolution (12bits) for best ever ECG signal quality Custom ECG Sampling Screen Displays for clear and high quality viewing of real time ECG, Superimposed Reference/actual Averaged ECG Complex, Full Disclosure, in 1, 3, 6 or 12-lead mode Instant Real Time ECG print outs or ECG Event Marker for later ECG review DM Software Holter algorhythm for Heart Rate Triggering, ECG Averaging, wandering baseline correction, antialising and noise filtering technique User settings for ST analysis from J-point or ST point, Absolute or Delta ST Method, ST elevation and depression criteria Actual ECG versus Reference ECG or prior stage ECG comparison during test Color coded Arythmia analysis from DM Software Holter ECG technology Auto, Hold, Manual modes for Treadmill and Ergometer control Auto or Manual NIBP measurement input Full Disclosure ECG Review, Heart Rate Recovery, individual ST Graph with ECG replay with superimposition, multi trends and graphs, ST reanalysis Multiple well known Protocols integrated and unlimited creation of new protocols Multi Ergometers, Treadmills, VO2 interfaces, 2 Analog ECG outputs Windows 2000, NT, XP, Vista, Tablet PC Compatible E-mail, PDF, ASCII, GDT, HL7, Dicom interfaces. 2100mm*820mm*1400mm Weight: 230 kg.
Holter ECG sysytem, ambulatory BP monitor.
Spo2, ECG, EKG, holter recorder.
ECG products, holter ECG, resting ECG, stress test ECG, ambulatory blood pressure monitor, ECG simulator, patient monitor.
Lepu portable ECG holter monitor is a small, lightweight device that is used to record the electrical activity of the heart. It is easy to use and can be used to monitor the heart rate, heart rhythm, and detect any abnormalities in the heart. The device is small enough to be carried with you and can be used in both clinical and home settings. It is also useful for tracking changes in the ECG over time and can be used to identify any underlying cardiovascular conditions. The device is also portable and can be used in remote settings, allowing for more accurate and timely diagnoses. Lepu Medical AI ECG Monitors Types Lepu Medical Handheld PCECG-500 Pocket ECG Machine Portable 12-lead Resting ECG Monitor for Home Clinic and Primary Health Care LEPU PCECG-500 Pocket EKG Machine is portable, lightweight and easy to use. It provides the collection, analysis, storage and transmission of 12-lead ECG information, which in combination with the Glasgow algorithm to provide complete and immediate analysis. Compared to traditional heavy ECG machines, our small PCECG-500 is a great choice for Bedside Monitoring.
ECG gel, also known as electrocardiogram gel or EKG gel, is a conductive medium used in electrocardiography (ECG) procedures to improve the quality of electrical signal transmission between the skin and the electrodes of the ECG machine. Here's more information about ECG gel: Purpose: The primary purpose of ECG gel is to enhance the conductivity and reduce impedance between the skin and the ECG electrodes. This improves the quality and accuracy of the electrical signals detected by the electrodes, resulting in clearer and more reliable ECG readings. Composition: ECG gel is typically a water-based, conductive gel formulated to be non-greasy, non-staining, and hypoallergenic. It may contain ingredients such as water, glycerin, propylene glycol, carbomer, preservatives, and conductivity-enhancing agents. Conductivity: ECG gel is formulated to have high electrical conductivity, allowing it to effectively transmit electrical signals between the skin and the electrodes. This conductivity helps minimize impedance and artifacts, ensuring accurate ECG readings even in challenging conditions. Viscosity: ECG gel is usually designed to have a suitable viscosity that allows for easy application and smooth spreading on the skin. It should be thick enough to stay in place during the procedure but not so thick that it hinders electrode placement or skin contact. Compatibility: ECG gel is compatible with various types of ECG electrodes, including disposable electrodes, reusable electrodes, and adhesive electrodes. It can be used with both standard ECG procedures and specialized cardiac tests such as stress tests, Holter monitoring, and echocardiography. Application: ECG gel is applied directly to the skin at the electrode sites before attaching the electrodes. A sufficient amount of gel should be applied to ensure good contact between the electrodes and the skin surface. Excess gel can be wiped away after electrode placement. Hygiene: ECG gel should be stored in a clean and dry environment to prevent contamination. Disposable single-use packets or bottles with dispensing caps are commonly used to maintain hygiene and prevent cross-contamination between patients. Removal: After the ECG procedure, any remaining gel should be wiped off the skin using a clean, dry cloth or disposable wipe. Residual gel left on the skin can cause discomfort or irritation if not properly removed.
High-conductivity gel for electrocardiography (ECG) is a specialized conductive gel used to improve electrical conductivity between the skin and ECG electrodes during cardiac monitoring procedures. Here's more information about high-conductivity gel for ECG: Purpose: The primary purpose of high-conductivity gel is to reduce impedance and improve the transmission of electrical signals between the skin and the ECG electrodes. This ensures accurate and reliable recording of the heart's electrical activity during ECG testing. Composition: High-conductivity gel is typically water-based and contains conductive agents that enhance its electrical conductivity properties. Common ingredients may include water, glycerin, propylene glycol, carbomer, electrolytes (e.g., sodium chloride), and preservatives. Conductivity: High-conductivity gel is formulated to have superior electrical conductivity compared to standard ECG gels or other electrode contact solutions. This allows for better signal quality and minimizes the risk of artifacts or interference during ECG recordings. Viscosity: The gel's viscosity is designed to be suitable for easy application and spreadability on the skin. It should be thick enough to adhere to the skin and maintain contact with the electrodes but not too thick that it hinders electrode placement or skin contact. Non-Staining: High-conductivity gel is typically formulated to be non-greasy and non-staining, ensuring minimal residue on the skin after use. This helps maintain patient comfort and prevents staining of clothing or bedding. Compatibility: High-conductivity gel is compatible with various types of ECG electrodes, including disposable electrodes, reusable electrodes, and adhesive electrodes. It can be used with standard ECG machines and Holter monitors. Application: Before applying the gel, the skin should be cleaned to remove any oils, lotions, or dirt that may interfere with electrode contact. A thin layer of high-conductivity gel is then applied to the skin at the electrode sites before attaching the electrodes. Hygiene: High-conductivity gel should be stored in a clean and dry environment to prevent contamination. Disposable single-use packets or bottles with dispensing caps are commonly used to maintain hygiene and prevent cross-contamination between patients. Overall, high-conductivity gel plays a crucial role in ensuring optimal electrode-skin contact and signal quality during ECG testing. Its superior conductivity properties make it an essential accessory in cardiac diagnostic procedures, allowing for accurate interpretation of the heart's electrical activity.
ECG ECG-01: Digital 12-lead, Single channel, character LCD, measure report, RS232 interface (software optional) ECG-01D: Digital 12-lead, Single channel, 320x240 LCD, waveform display, RS232 interface (software optional),measure report, 8 patients' information deposit ECG-03: Digital 12-lead, Single/Three channel, 192x64 LCD, waveform display,RS232 interface (software optional), measure report ECG-03A: Digital 12-lead, Single/Three channel, 320x240 LCD, waveform display, RS232 interface (software optional), 8 sets data memory, measure and analysis report (analysis software is optional) ECG-03B: Digital 12-lead, Single/Three channel, 192x64 LCD, waveform display, RS232 interface, software is optional, measure and analysis report (analysis software is optional) ECG-061: Digital 12-lead, Six channel with analysis and waveform display, RS232 interface (software is optional), 16 sets data and analysis result memory (optional) ECG-121: Digital 12-lead, Twelve channel with analysis and waveform display, RS232 interface (software is optional), 16 sets data and analysis result memory (optional)