Clamp on ground resistance tester ETCR 2000C *Accurate ground resistance measurement from 0.01to 1000Ohms *current measurement including leakage current *Accurate readings regardless of power quality in 1 seconds *Simple and easy to use, no test leads or auxiliary electrodes necessary *Data logging capability - 50 records *Individual data point recording *User selectable audible alarms *Auto power off *Low battery indicator *Large LCD display Ground Resistance: 0.010 - 0.099 Ohms (¿¬+ 1% ¿¬+ 0.01 Ohms, resolution 0.001 Ohms) Ground Resistance: 0.10 - 0.99 Ohms (¿¬+ 1% ¿¬+ 0.01 Ohms, resolution 0.01 Ohms) Ground Resistance: 1.0~49.9 Ohms (¿¬+ 1.5% ¿¬+ 0.1 Ohms, resolution 0.1 Ohms) Ground Resistance: 50.0~99.5 Ohms (¿¬+ 2% ¿¬+ 0.5 Ohms, resolution 0.5 Ohms) Ground Resistance: 100~199 Ohms (¿¬+ 3% ¿¬+ 1 Ohms, resolution 1 Ohms) Ground Resistance: 200~395 Ohms (¿¬+ 6% ¿¬+ 5 Ohms, resolution 5 Ohms) Ground Resistance: 400~590 Ohms (¿¬+ 10% ¿¬+ 10 Ohms, resolution 10 Ohms) Ground Resistance: 600~1000 Ohms (¿¬+ 20% ¿¬+ 20 Ohms, resolution 20 Ohms) Ground Leakage Current: 0.00~299 mA (¿¬+ 5% ¿¬+2 mA) resolution 1 MA Ground Leakage Current: 100~299 mA (¿¬+ 5% ¿¬+5 mA) resolution 1 mA Ground Leakage Current: 0.30~2.99 A (¿¬+ 5% ¿¬+0.03 mA) resolution 10 mA Ground Leakage Current: 0.30~2.99 A (¿¬+ 5% ¿¬+0.03 mA) resolution 10 mA Ground Leakage Current: 10.00~20.00 A (¿¬+ 5% ¿¬+0.5 mA) resolution 10 mA.
Product description Earth ground resistance tester is a high-precision testing instrument used in various fields such as substations to test grounding resistance and related parameters.The instrument is of an integrated structure, with a built-in frequency conversion power supply module, and the output power supply is continuously variable in frequency. The frequency can be changed to 45Hz or 55Hz, the high-speed processor core is built in, and the high-end digital filtering technology is adopted, thus effectively avoiding the interference of power frequency electric field to the test and fundamentally solving the difficult problem of accurate measurement under strong electric field interference. Technical index 1 Conditions of use 1 540 RH 80% 2 Anti-interference principle Frequency conversion method 3 Electric source AC 220V 10% allowed generator 4 Measure output current 1A 5A Adjustable 5 Measure output voltage 0V 100V 6 Test power frequency 45, 50, 55, 60, 65HZ single frequency 45 55, 55 65 47.5 52.5HZ Automatic Dual Frequency 7 Output rating 500W 8 Distinguishing rate Grounding impedance 0.0001 Impedance angle 0.0001 9 Precision Grounding impedance 1% reading 0.002 Impedance angle 1% reading 0.02 10 Resistance measurement range 0.001 5 11 Exterior dimensions 370 295 W 225 H 12 Memory size 100 groups support U disk data storage 13 Weight Main engine 13 Kg, ground pile 7 Kg
Main features:1. 2/3/4-wires measurement of earth resistance, soil resistivity, earth voltage, , ac voltage;, 2.Measurement range: earth resistance: 0.00î©-30.00kî©; 0~600v, soil, resistivity: 0.00î©m-9000kî©m; 3. Data upload: rs232 interface, 4.Date storage:300 sets, model no:mewoi4000c, name:mewoi4000c-earth ground resistance/soil resistivity tester, electrode distance range:can be set 1m-100m, low power consumption:standby:1. About 20ma (backlight shut off), 2.Boot and with backlight: about 45ma, (25ma without backlight), 3.Measurement: about 100ma, (backlight shut off)
Digital Ground Resistance Tester Rejects the traditional manual manual power generation method adopts advanced media and large scale integrated circuits, and uses DC / AC conversion techniques to combine the triple buttons and four-end button measurement modes with new ground resistors. . The working principle is that the DC / AC converter in the machine changes the DC constant current, and the circuit is formed by the auxiliary ground electrode C and the measurement object E, which generates an AC voltage drop on the measuring object, and feeds the AC amplifier through assist grounding. The electrode P amplified, and then multiplied by multiplying by multiplying by a power switch to display the instrument header head, you can get three different number limits Nearly the resistance tester is suitable for measuring the electrical resistance of low resistance of various departments such as various devices and power postal railway communication mining; Nearly the ground resistance tester also measures soil resistivity and ground voltage. Technical parameters Working Conditions Ambient temperature 0+45 Relative humidity 85%RH Measurement range and constant current value (effective value) Resistance 020(10mA)2200(1mA)202000(0.1mA) Voltage AC019.99V Measurement accuracy and resolution Precision rowspan 0 0.23%1d
Product description Earth ground resistance tester is a high-precision testing instrument used in various fields such as substations to test grounding resistance and related parameters.The instrument is of an integrated structure, with a built-in frequency conversion power supply module, and the output power supply is continuously variable in frequency. The frequency can be changed to 45Hz or 55Hz, the high-speed processor core is built in, and the high-end digital filtering technology is adopted, thus effectively avoiding the interference of power frequency electric field to the test and fundamentally solving the difficult problem of accurate measurement under strong electric field interference. Technical index 1 Conditions of use 15 40 RH 80% 2 Anti-interference principle Frequency conversion method 3 Electric source AC 220V 10% allowed generator 4 Measure output current 1A 5A Adjustable 5 Measure output voltage V100V 6 Test power frequency 45, 50, 55, 60, 65HZ single frequency 45 55, 55 65 47.5 52.5HZ Automatic Dual Frequency 7 Output rating 500W 8 Distinguishing rate Grounding impedance 0.0001 Impedance angle 0.0001 9 Precision Grounding impedance (1% reading +0.002) Impedance angle (1% reading +0.02 ) 10 Resistance measurement range 0.001 5
Overview Digital Ground Resistance Tester Rejects the traditional manual manual power generation method adopts advanced media and large scale integrated circuits, and uses DC / AC conversion techniques to combine the triple buttons and four-end button measurement modes with new ground resistors. . The working principle is that the DC / AC converter in the machine changes the DC constant current, and the circuit is formed by the auxiliary ground electrode C and the measurement object E, which generates an AC voltage drop on the measuring object, and feeds the AC amplifier through assist grounding. The electrode P amplified, and then multiplied by multiplying by multiplying by a power switch to display the instrument header head, you can get three different number limits 0 2 0 20 0 200
Earth ground resistance tester is a high-precision testing instrument used in various fields such as substations to test grounding resistance and related parameters.The instrument is of an integrated structure, with a built-in frequency conversion power supply module, and the output power supply is continuously variable in frequency. The frequency can be changed to 45Hz or 55Hz, the high-speed processor core is built in, and the high-end digital filtering technology is adopted, thus effectively avoiding the interference of power frequency electric field to the test and fundamentally solving the difficult problem of accurate measurement under strong electric field interference.
Application: ETCR2000 clamp ground resistance tester is a major technological breakthrough in traditional grounding resistance measurement. It is widely used in the grounding resistance measurement of electric power telecommunications meteorology oilfield construction and industrial and electrical equipment. When measuring circuit grounding system it is not necessary to disconnect the each connection wire and use auxiliary electrode it is safe and quick easy to use. Can measure the grounding fault which can not be measured by the traditional method because this instrument measure the integrated value of grounding resistance and ground lead resistance apply to the occasion that can not use the traditional method. Features: Apply to all kinds of ground lead.(round bar flat bar angle iron). Non-contact measured grounding resistance safe fast. Without using assistant ground rod. Without interrupting the grounding of the device under test. With double protecting insulation. With strong anti-interference ability and high accuracy. Use 5# alkaline batteries convenient for users.
Application: ETCR2000 clamp ground resistance tester is a major technological breakthrough in traditional grounding resistance measurement. It is widely used in the grounding resistance measurement of electric power telecommunications meteorology oilfield construction and industrial and electrical equipment. When measuring circuit grounding system it is not necessary to disconnect the each connection wire and use auxiliary electrode it is safe and quick easy to use. Can measure the grounding fault which can not be measured by the traditional method because this instrument measure the integrated value of grounding resistance and ground lead resistance apply to the occasion that can not use the traditional method. Features: Apply to all kinds of ground lead.(round bar flat bar angle iron). Non-contact measured grounding resistance safe fast. Without using the assistant ground rod. Without interrupting the grounding of the device under test. With double protecting insulation. With strong anti-interference ability and high accuracy. Use 5# alkaline batteries convenient for users.
Application: ETCR2000 clamp ground resistance tester is a major technological breakthrough in traditional grounding resistance measurement. It is widely used in the grounding resistance measurement of electric power telecommunications meteorology oilfield construction and industrial and electrical equipment. When measuring circuit grounding system it is not necessary to disconnect the each connection wire and use auxiliary electrode it is safe and quick easy to use. Can measure the grounding fault which can not be measured by the traditional method because this instrument measure the integrated value of grounding resistance and ground lead resistance apply to the occasion that can not use the traditional method. Features: Apply to all kinds of ground lead.(round bar flat bar angle iron). Non-contact measured grounding resistance safe fast. Without using assistant ground rod. Without interrupting the grounding of the device under test. With double protecting insulation. With strong anti-interference ability and high accuracy. Use 5# alkaline batteries convenient for users.
Overview At present in the electric power system the grounding resistance of the earth network is mainly measured by power frequency large current tripole method. In order to prevent power frequency interference during power grid operation and improve the accuracy of measurement results insulation preventive test regulations stipulate that the test current of power frequency high-current method shall not be less than 30A. As a result there are many problems such as bulky test equipment complicated test process high working intensity and long test time. Ground Network Earth Resistance Tester adopts new frequency conversion ac power supply and adopts microcomputer processing control and signal processing and other measures which well solves the anti-interference problem in the test process simplifies the trial operation process improves the accuracy and accuracy of the test results and greatly reduces the labor intensity of test personnel and test cost. Ground Network Earth Resistance Tester is suitable for testing power frequency grounding impedance contact voltage step voltage power frequency characteristic parameters and soil resistivity of various grounding devices. measurable substation ground network (4) water and fire power plants microwave station (10) the lightning rod 10 multi-purpose machines. Ground Network Earth Resistance Tester adopts different frequency anti-interference technology which can accurately measure data at power frequency of 50Hz under strong interference environment. The maximum of test current is 3A which will not cause excessive potential of grounding device during the test. Meanwhile it also has strong anti-interference ability so it can be measured without power failure.
Product Introduction At present in the electric power system the grounding resistance of the earth network is mainly measured by power frequency large current tripole method. In order to prevent power frequency interference during power grid operation and improve the accuracy of measurement results insulation preventive test regulations stipulate that the test current of power frequency high-current method shall not be less than 30A. As a result there are many problems such as bulky test equipment complicated test process high working intensity and long test time. Ground Network Earth Resistance Tester adopts new frequency conversion ac power supply and adopts microcomputer processing control and signal processing and other measures which well solves the anti-interference problem in the test process simplifies the trial operation process improves the accuracy and accuracy of the test results and greatly reduces the labor intensity of test personnel and test cost. Ground Network Earth Resistance Tester is suitable for testing power frequency grounding impedance contact voltage step voltage power frequency characteristic parameters and soil resistivity of various grounding devices. �© measurable substation ground network (4) water and fire power plants microwave station �© (10) the lightning rod (10 �©) multi-purpose machines. Ground Network Earth Resistance Tester adopts different frequency anti-interference technology which can accurately measure data at power frequency of 50Hz under strong interference environment. The maximum of test current is 3A which will not cause excessive potential of grounding device during the test. Meanwhile it also has strong anti-interference ability so it can be measured without power failure.
At present in the electric power system the grounding resistance of the earth network is mainly measured by power frequency large current tripole method. In order to prevent power frequency interference during power grid operation and improve the accuracy of measurement results insulation preventive test regulations stipulate that the test current of power frequency high-current method shall not be less than 30A. As a result there are many problems such as bulky test equipment complicated test process high working intensity and long test time. Ground Network Earth Resistance Tester adopts new frequency conversion ac power supply and adopts microcomputer processing control and signal processing and other measures which well solves the anti-interference problem in the test process simplifies the trial operation process improves the accuracy and accuracy of the test results and greatly reduces the labor intensity of test personnel and test cost. Ground Network Earth Resistance Tester is suitable for testing power frequency grounding impedance contact voltage step voltage power frequency characteristic parameters and soil resistivity of various grounding devices. �© measurable substation ground network (4) water and fire power plants microwave station �© (10) the lightning rod (10 �©) multi-purpose machines. Ground Network Earth Resistance Tester adopts different frequency anti-interference technology which can accurately measure data at power frequency of 50Hz under strong interference environment. The maximum of test current is 3A which will not cause excessive potential of grounding device during the test. Meanwhile it also has strong anti-interference ability so it can be measured without power failure. Product nickname Earth grid earth resistance tester earth grid earth resistance tester large earth grid earth resistance tester
At present in the electric power system the grounding resistance of the earth network is mainly measured by power frequency large current tripole method. In order to prevent power frequency interference during power grid operation and improve the accuracy of measurement results insulation preventive test regulations stipulate that the test current of power frequency high-current method shall not be less than 30A. As a result there are many problems such as bulky test equipment complicated test process high working intensity and long test time. Ground Network Earth Resistance Tester adopts new frequency conversion ac power supply and adopts microcomputer processing control and signal processing and other measures which well solves the anti-interference problem in the test process simplifies the trial operation process improves the accuracy and accuracy of the test results and greatly reduces the labor intensity of test personnel and test cost. Ground Network Earth Resistance Tester is suitable for testing power frequency grounding impedance contact voltage step voltage power frequency characteristic parameters and soil resistivity of various grounding devices. �© measurable substation ground network (4) water and fire power plants microwave station �© (10) the lightning rod (10 �©) multi-purpose machines. Ground Network Earth Resistance Tester adopts different frequency anti-interference technology which can accurately measure data at power frequency of 50Hz under strong interference environment. The maximum of test current is 3A which will not cause excessive potential of grounding device during the test. Meanwhile it also has strong anti-interference ability so it can be measured without power failure.
Earth Resistance Tester: Model: ETCR2100+(basal) Category: Ground Resistance tester Earth Resistance Tester (ETCR2100+)-Illustration: ETCR 2100+ of Pincers Earth Tester, in the measurement of a grounding system with loop current, does not require breaking down the grounding wire, and need no auxiliary electrode. It is safe, fast and simple in use. 1.Wider range: 0.01Ñ+-1200Ñ+ 2.Stored data: 99 groups. 3.Resistance Resolution: 0.01Ñ+ 4.Size of Jaw: ¬¬32ú¿mmú¬ 5. Sound and light alarm, "beep - beep - beep -" alarm sound. 6. Breakthrough in self-test the boot a long time to wait, start immediately into the test. 7. Breakthrough relay self-test mode, using the most advanced processing algorithms and digital integration technology, a fully intelligent. 8. Break the old product to heavy issues, more in line with characteristics of handheld devices. 9. The new design, panel 6 button operation, the performance through. 10. Lower power consumption: Maximum operating current not exceeding 50mA. 260*90*66(MM)
Specifications Function AC leak currentú¼high-harmonic currentú¼0n line current testú¼phaseíóelectrical energyú¼power factor revise Test mode Clip-onCT Output mode Current mutual inductance output uA/mAú+mA/A or voltage output mV/mAú+mV/Aú¿lectotypeú¬ Dimensions Widthí-heightí-thicknessú¦64mmí-160mmí-23mm Clamp mouth ª+40mm Wire length 2.0mú¿by orderú¬ Measure range AC 1uAí½80Aú+10uAí½300Aú+10mAí½600Aú¿lectotypeú¬ Resolution 1uAú+10uAú+5mAú¿lectotypeú¬ Accuracy 1% ú+2%ú¿50Hzú+25íµí+3íµú¬ú¿lectotypeú¬ Linearity degree 1% ú+2%ú¿50Hzú+25íµú¬ú¿lectotypeú¬ Work frequency 10í½100KHz Wire voltage Line test under AC600V Quality About120g Working temperature and humidity -25íµí½70íµú+below 80%rh Storage temperature and humidity -10íµí½60íµú+below 70%rh Insulation AC2kV/rms (between core and box) Applicable safety rules IEC1010-1íóIEC1010-2-032íópollution, etc 2íóCAT ó=(600V).
Specifications Function AC leak currentú¼high-harmonic currentú¼0n line current testú¼phaseíóelectrical energyú¼power factor revise Test mode Clip-onCT Output mode Current mutual inductance output uA/mAú+mA/A or voltage output mV/mAú+mV/Aú¿lectotypeú¬ Dimensions Widthí-heightí-thicknessú¦138mmí-42mmí-20mm Clamp mouth ª+7.5mm Wire length 2.0mú¿by orderú¬ Measure range AC 1uAí½10Aú+ 5uAí½20Aú+10uAí½50A Resolution 1uAú+5uA ú¦10uAú+ú¿lectotypeú¬ Accuracy 0.1-0.2ú¿50Hzú+25íµú¬ Ungraded load í_50ª+ Work frequency 10í½100KHz Wire voltage Line test under AC600V Quality About175g Working temperature and humidity -25íµí½70íµú+below 80%rh Storage temperature and humidity -10íµí½60íµú+below 70%rh Insulation AC2kV/rms (between core and box) Applicable safety rules IEC1010-1íóIEC1010-2-032íópollution, etc 2íóCAT ó=(600V).
Led bulb, tube light, panel light, decoration light, wall light, steel wires, steel plate, stainless steel plate, twisted wire rods, galvanized wires, wire mesh, site fencing, mosquito mesh, thread rods, rebar, twisted rods, t bar, nuts and bolts, hardware, pvc pipes, upvc pipes, api pipes, melamine, mdf board, plywood, film faced, shuttering, packing, core veneer, face veneer, hdf molded door skin, door filler, tubular particle boards, pvc boards, wpc boards, doors, block board, hard board, gypsum board, canopy, carpet, flooring wooden, bamboo, laminated engineering, tiles, granite tiles, granite blocks, black galaxy, wash basin, water closets, washbasins, ss sinks, faucets, furniture, pvc edge bending, crew, locks, pvc seals, silicone cartridges, shower enclosures, shower door hinges, handles, knobs, brackets, slides, nails, solar panels, flexible solar panels, solar power station, battery, inverters, rechargeable fans, lights, spring, 3ply disposable face mask, oxygen concentrator ,.Buying office, oem, components sourcing, value added services
Ground resistance tester, phase detector, earth clamp meter, electronic instrument.