I product features Using unique pulse phase modulation method eliminate tubes acoustic oscillation to ensure the safety of tubes, prolong services life. Adopt unique pulse deduct technology to achieve overload protection. Its consumption is low, the efficiency is as high as 96%; the power factor above 0.99, low total harmonic current distortion, less impact on power network. Wide working voltage range: ac 90v~260v, which can guarantee the output power constant when the input power voltage is unstable. Perfect protection function, such as built-in overvoltage, undervoltage, output short circuit, open circuit, which can protect automatically for safe use. Low temperature rise, it is suitable for wide range environment temperature: -30? to +50?(-22~+122f) Ii technical parameters Lamp watts: 110w high pressure sodium lamp Input voltage frequency: 50/60hz Input voltage range: 160-260v ac Input current: 0.54a Power factor: >0.99 Total harmonic current distortion: =8% Short circuit protection yes Open circuit protection yes Overheating protection yes Lamp failure protection yes Temperature range : - 30 ? ~ + 50 ? Size (l * w* h) 148 x 77 x 51.2 mm Iii: standards and certification: Safety en61347-2-12 Emi en61000-3-2 Ems cisper15.Ed7.2 Quality standard iso9001 Environmental standards iso1400 Related certification ce/ccc
Ranges from 18W, 26W, 35W, 55W, 66W, 90W, 91W, 135W etc and the LAX series of electronic ballasts for Low Pressure Sodium lamp developed by leianxun company adopt the SCM CPU digital technique. It insures the intellectual protection of electronic ballasts---keeping the safety of ballasts and the system , when the voltage output terminal is abnormal. In the process of warm-up, triggering, and ignition, the CPU can reach the best state to protect the electrode of lamp /tubes. This is measured by the microsecond controlling span of system and the height of impulse from the trigger voltage. Thus it doubles the longevity of the electrode for lamp tubes greatly. It is perfect for solar power of street lighting.
Supply Voltage Applicable Tube Dimension Size 110/220/240V T5 T8 257*30*19/240*30*18. 50/60hz.
Type: magnetic or electronic ballast, T5/T8 or ceiling ballast. Material: 0.3mm iron, fire-proof ABS CBM: 55*55*30/1pcs 32*33*35/100pcs 33.5*32*35.5/50pcs 43*16.5*75/20pcs 23*20.5*10/15pcs 23*16.5*14/20pcs 22*20.5*10/20pcs High harmonic, low power, low work temperature, low voltage launch. Protect for momentary high voltage and abnormal state. Conforms to 3C, GB15143-1994, GB17743-1999 standard strictly.
Electronic ballast for uhp-projector lighting reources Electronic ballast for metal halide lamps Electronic ballast for stage light hid Varieties of electronic ballast for your choosing
Electronic ballast 40w choke 10 pcs.
Electronic ballast 1) power voltage: 220v 2) power frequency: 50-60hz 3) power factor: 0.98 4) coeffcient: 0.99 5) thd: n15% 6) cf: n1.7 8) specifications: 1 x 24w, 2 x 24w, 3 x 24w, 1 x 36w, 2 x 3 6w, 3 x 36w, 1 x 40w, 2 x 40w, 1 x 55w, 2 x 55w
Rohs compliance CE approved Nemko approved
Electronic ballast for cfl and t5, t8, t12 fluorescent lamps
Ballast for T5,T8,T9,T12,circle,PL,PLC,dimmable, remote-control and ignitors for HID
For 14W T5 Florescent lights
Electronic Ballasts for UV lamps
H1-1000ckl-gba 120v~240v, 1000w high frequency ballast Dimmable Ce/ul
Suitable for hps bulb of america and europe standard Input voltage: 100-265vac (120v/240v) Output frequency: 30khz, 20khz(1000w) Input frequency: 50/60hz Power factor: .98 Thd:
An Electronic Ballast is a device/instrument used to control the amount of current in on electric circuit, Also referred as a control gear, an electronic. If generates high frequency alternative goes about more then 25Khz. High freq. allows to lower the system rating without reducing the luminous flux of the lamps. Also available series of
An Electronic Ballast (Sometimes called control gear) is a device intends to limit the amount of current in an Electronic circuit. An Electronic lamp ballast uses solid state electronic circuitry to provide the proper starting and operating electrical Condition to power fluorescent lamps (FTL).An Electronics ballast dissipates some heal around 90%. GRE’s industrial ballast series heaving special features like EMI/RFI filters, spike protections, high power factors etc. Also available ballast series of
28W 220~240 V ,50/60 HZ PF>0.97, CF0.97.
Dimmable electronic ballasts Fl 2x35/220-240v t5 dim-a Dimming range from 1-100% Lamp start at 1% possible Standard dc1-10v control interface (en60929 with earth leakage 0.5ma) Defined lamp friendly warm start within 1.5 s with ac and 0.6s with dc Dc operation in emergency lighting Installations to vde0108 Safe shutdown of defective lamps Safe shutdown of lamps at end of life Automatic restart after lamp replacement Operating frequency ~40-120khz Carton
T8 electronic ballast 1)power voltage: 220v 2)power requency: 50-60hz 3)power actor: 0.98 4)coecient: 0.95 5)thd: n15% 6)c: n1.7 8)speciications: 1 x 18w, 2 x 18w, 3 x 18w, 1 x 30w, 2 x 30w, 3 x 30w, 1 x 36w, 2 x 36w, 3 x 36w, 1 x 58w, 2x58w, etc 9) metal housing We can manuacture dierent sizes and speciications o Electronic ballasts according to customers' request.