Electrode, ECG, 42mmx50mm, Adult, Foam, Solid Gel 1. Fair average qualiy assured; 2. Comfortable and conveniet; 3. No gel left and non-irritable; 4. Single use only; 5. Recommended for ICU/CCU, Surgery, Emergency.
We are your reliable source for high-quality welding electrodes that deliver exceptional performance in diverse welding applications. We recognise that the welding industry demands products that are durable, efficient, and capable of producing superior welds. Our unique challenge lies in ensuring that the welding electrodes we import adhere to stringent quality standards. To address this, we partner with established manufacturers who have a proven track record of delivering reliable welding products. We conduct comprehensive quality control checks on each batch of welding electrodes, verifying their chemical composition, tensile strength, and welding performance. By doing so, we guarantee that the welding electrodes we supply consistently meet or exceed industry standards, enabling our customers to achieve impeccable welding results.
ECG cables also referred to as an ECG patient cable, is a type of cable connection designed for non-invasive heart monitoring, typically used to help diagnose potential heart issues. The ECG cable connects to electrodes which are positioned at specific locations on the patientâ??s body to detect and record heart muscle electrical activity. The cables then transmit the electrical activity back to the ECG device for analysis and diagnosis by medical professionals. ECG Cable Feature [Multiple Leads]: ECG cables usually have several leads placed in specific areas on the patientâ??s body, such as the chest, arms, and legs, to measure the heartâ??s electrical activity from different angles. [Durability]: ECG cables are constructed from top-quality, sturdy materials that can endure repeated bending, tugging, and twisting without sustaining any damage. This ensures that the cables can withstand the rigors of frequent use and remain reliable over time. [Shielding]: ECG cables are shielded to block out external electrical signals, which can interfere with the accuracy of the readings. [Connector Compatibility]: The ECG cables are available with various connector types, including snap, clip, and banana, to fit different types of ECG machines. [Safety]: ECG cables are designed to meet strict safety standards and regulations to ensure patient safety. This helps to ensure that patients are protected from any potential harm during the monitoring process. [Cleaning and Disinfecting]: The ECG cables are easy to clean and disinfect to maintain hygienic conditions, as they come into contact with the patientâ??s skin. ECG Cable Advantages [Excellent Performance]: ECG cables are built to withstand the rigors of twisting and bending, and have been thoroughly tested to ensure optimal performance. The cables are also equipped with electrical shielding to protect the signal integrity, ensuring accurate readings. [Non-Invasive]: ECG cables are non-invasive, which means that they do not require any incisions or invasive procedures. This reduces the risk of infection and makes the monitoring process much safer for patients. Instead, the cables are simply attached to the patient's skin, making it a quick and painless process.
The graphite electrode comprises: (1) Regular power graphite electrode( RP grade Graphite Electrode) . Graphite electrode with current density less than 17a / cm2 is allowed to be used in common power electric furnaces for steelmaking, silicon smelting and yellow phosphorus smelting. (2) Oxidation resistant coating graphite electrode. A graphite electrode coated with an anti-oxidation protective layer (graphite electrode anti oxidant). The formation of both conductive and high temperature oxidation resistant protective layer can reduce the electrode consumption (19% ~ 50%), prolong the service life of the electrode (22% ~ 60%), and reduce the electric energy consumption of the electrode. The popularization and application of this technology can bring such economic and social effects as follows: 1. The unit consumption of graphite electrode is less, and the production cost is reduced to a certain extent. For example, according to the consumption of 35 graphite electrodes per week and 165 refining heats of LF refining furnace in a steel-making plant without shutdown in the whole year, 373 (153 tons) electrodes can be saved every year by using graphite electrode oxidation resistance technology, and RMB 2585700 can be saved by RMB 16900 per ton of ultra-high power electrode per year. 2 The graphite electrode consumes less electricity, saves the unit electricity consumption of steelmaking, saves the production cost, saves energy! 3. Because the graphite electrode is replaced less times, the labor amount and risk coefficient of operators are reduced, and the production efficiency is improved. 4 Graphite electrode is a high consumption and high pollution product, which has a very important social significance in the days of promoting energy conservation, emission reduction and environmental protection. This technology is still in the stage of research and development in China, and some domestic manufacturers have begun to produce it. It is widely used in Japan and other developed countries. At present, there are also companies that import the anti-oxidation protective coating in China. (3) High power graphite electrode (HP grade Graphite Electrode). Graphite electrode with current density of 18-25a / cm2 is allowed to be used in high power electric arc furnace for steelmaking. (4) Ultra high power graphite electrode( UHP grade Graphite Electrode). Graphite electrode with current density greater than 25A / cm2 is allowed. It is mainly used in ultra high power EAF.
UHP 400mm*1800mm UHP 450mm*1800mm Used in steel, cement and glass manufacturing, expanded graphite - based sealing gaskets, graphite grease, braid, brushes, brake lining, etc.
ECG electrodes offer stable and reliable ECG traces. Latex free ECG electrodes, which are manufactured by a special online process which keeps the product environmental friendly and fresh. The aggressive adhesive allows for excellent patient adherence and withstands difficult conditions found in emergency conditions. Features: Latex free. Hypo-allergic adhesive. Specially formulated solid gel delivers excellent results with no post procedural clean up. Unique gel allows to provide the best possible interface between patient & the machine. Dimensions (HxWxT) 45 x 42 x 1 mm Suggested use Stress/ Resting/ Monitoring. Available in a convenient pack of 100 pieces. Minimum Order Quantity 500 Piece Usage/Application hospital Model Number/Name Brand Multibrand Type ELECTRODES Features Latex free,PVC Free entred snap with conductive solid gel column ensures Miscellaneous Product Code Dimensions (HxWxT) 45 x 42 x 1 mm
Full automatic processing ECG production machine in china,best quality assured; FDA authorization in china,CE,Iso13485; Comfortable and convenient,no residual & non-irritable; Excellent adhesive from special gel formula; Different sizes and materials have been studied to meet the different requirements; PS: All electrodes are Non-irritating,Non-sensitizing,Non-cytotoxic; Latex free and PVC free; Short/long monitoring,stress test,Holter,Emergency procedures,Radio translucent. Metal snap, Ag/AgCI sensor,low impedance solid medical conductive gel,white or original color PE foam tape or cloth tape with medical hypoallergenic adhesive,white PE tape indicated brand mark, PET anti-sticking film. General monitoring Foam,stainless steel snap Recommended usage: ICU/CCU,Surgery,Emergency. Description Packaging Ctn size Child,solid gel, 36x44mm 50pcs/pk,40pk/ctn 48x36x28cm Adult,solid gel,50x55mm 50pcs/pk,40pk/ctn 48x36x28cm Adult,solid gel,42x50mm 50pcs/pk,40pk/ctn 48x36x28cm Adult,solid gel,Dia.50mm 50pcs/pk,40pk/ctn 48x36x28cm Neonatal,solid gel,dia.25.4mm 50pcs/pk,40pk/ctn 40x36x28cm Cloth Stainless steel snap Recommended usage: ICU/CCU,Emergency,long term Description Packaging Ctn size Cloth,solid gel, dia.50mm 50pcs/pk,40pk/ctn 48x36x28cm Radiotransucent Foam,radiolucent snap Recommended usage: Surgery,Emergency,Cath lab,Radiology. Description Packaging Ctn size Adult,Solid gel,Dia.50mm 50pcs/pk,40pk/ctn 48x36x28cm Stress/Diaphoretic Recommended usage: ICU/CCU,Surgery,Holter,Emergency Description PackagingCtn size Adult,Solid gel,42x37mm 50pcs/pk,40pk/ctn 48x36x28cm Wet gel Recommended usage: ICU/CCU,Surgery,Stress,Holter,EMS,Emergency Description Packaging Ctn size Adult,Wet gel,52x47mm 50pcs/pk,40pk/ctn 48x36x28cm Prewired Neonatal Recommended usage: NICU,PICU Description Packaging Ctn size Neonatal,22x22mm 3pcs/pk,10pk/box,12bx/ctn 48x22x22cm Repositionable Recommended usage: ICU/CCU,Surgery,Emergency,Cath lab,Radiology Description Packaging Adult,solid gel,32x40mm 3pcs/pk,10pk/box,12bx/ctn Diagnostic-TAB/Resting Electrode Recommended usage: Cardiology,resting ECG DescriptionPackaging Ctn size 20x34mm 10pcs/pk,50pk/bx,10bx/ctn30x19x23cm 23x34mm 10pcs/pk,50pk/bx,10bx/ctn30x19x23cm
Commodities namely metal steel, oil & petroleum such as diesel en590, bitumen, jeta1, lng, lpg, coal, wood pellets, urea, dap, copper cathode, etc. other products: seafood food, birdnest, japanese food products namely wagyu beef, japanese sake..
Place of Origin: China Brand Name: OEM Model Number: KR-M Disinfecting Type: Far Infrared Size: 50mm diameter, 50mm diameter Stock: Yes Shelf Life: 2 years Material: Foam paper,Metal buckle,Ag/AgCI electrode, Foam paper,Metal buckle,Ag/AgCI electrode Quality Certification: 13485 Instrument classification: Class I, Class I Safety standard: None Product Name: 50mm Round Medical Disposable Adult Neonatal Ecg Electrode Keyword: Ecg Electrode Shape: Round/oval/rectangle Warrenty: 2years Color: White Application: ECG Machine etc. MOQ: 50pcs
Item Code 15.27.000 Specification Strong Adhesive- sticks properly to the skin, removes without hurting the skin. Highly Conductive Hydro Gel to ensures Optimal Signal Quality. Used in ICU/CCU, Patient Rooms. Available in different shapes and sizes
disposable ECG Hydrogel electrodes with pregelled Ag/Agcl sensor of size 43 mm x 49 mm. the gel good electro conductivity and gives stable ECG Bio signals. it leaves no residue on the skin after removal of electrodes. quality : tested in ECG electrodes tester as per ANSI/AAMI standards. use : applications for ECG monitoring , diagnosis and stress test.
Meets ansi/aami standards Made of pe foam. With hypoallergenic acrylic adhsive Available in both solid gel and liquid gel variants in different shapes and sizes 50 electrodes in a pouch. 40 pouches (2000 electrodes) in a shipper carton.
ECG Snap Electrode Cleartrace Monitoring Non-Radiolucent Tape Backing 5 per Pack UOM: 1000/CS Product Number: 1700-050 Manufacturer: Conmed
Cleartrace2 Adult ECG Electrode, Radiotranslucent, Universal, with Adhesive Gel, Tape UOM: 600/CS Product Number: 2700-030 Manufacturer: Conmed
ECG Electrode with Leadwire 3M Red Dot Pre-Wired Radiolucent Tape Backing 3 per Pack UOM: 100/CS Product Number: 2269T Manufacturer: 3M
Electrode, ECG, 50mmx55mm, Adult, Foam, Solid Gel 1. Fair average qualiy assured; 2. Comfortable and conveniet; 3. No gel left and non-irritable; 4. Single use only; 5. Recommended for ICU/CCU, Surgery, Emergency.
Electrode, ECG, 25.4mm, Child, Foam, Solid Gel 1. Fair average qualiy assured; 2. Comfortable and conveniet; 3. No gel left and non-irritable; 4. Single use only; 5. Recommended for ICU/CCU, Surgery, Emergency.
Full automatic processing ECG production machine in china,best quality assured; FDA authorization in china,CE,Iso13485; Comfortable and convenient,no residual & non-irritable; Excellent adhesive from special gel formula; Different sizes and materials have been studied to meet the different requirements; PS: All electrodes are Non-irritating,Non-sensitizing,Non-cytotoxic; Latex free and PVC free; Short/long monitoring,stress test,Holter,Emergency procedures,Radio translucent. Metal snap, Ag/AgCI sensor,low impedance solid medical conductive gel,white or original color PE foam tape or cloth tape with medical hypoallergenic adhesive,white PE tape indicated brand mark, PET anti-sticking film. General monitoring Foam,stainless steel snap Recommended usage: ICU/CCU,Surgery,Emergency. Description Packaging Ctn size Child,solid gel, 36x44mm 50pcs/pk,40pk/ctn 48x36x28cm Adult,solid gel,50x55mm 50pcs/pk,40pk/ctn 48x36x28cm Adult,solid gel,42x50mm 50pcs/pk,40pk/ctn 48x36x28cm Adult,solid gel,Dia.50mm 50pcs/pk,40pk/ctn 48x36x28cm Neonatal,solid gel,dia.25.4mm 50pcs/pk,40pk/ctn 40x36x28cm Cloth Stainless steel snap Recommended usage: ICU/CCU,Emergency,long term Description Packaging Ctn size Cloth,solid gel, dia.50mm 50pcs/pk,40pk/ctn 48x36x28cm Radiotransucent Foam,radiolucent snap Recommended usage: Surgery,Emergency,Cath lab,Radiology. Description Packaging Ctn size Adult,Solid gel,Dia.50mm 50pcs/pk,40pk/ctn 48x36x28cm Stress/Diaphoretic Recommended usage: ICU/CCU,Surgery,Holter,Emergency Description Packaging Ctn size Adult,Solid gel,42x37mm 50pcs/pk,40pk/ctn 48x36x28cm Wet gel Recommended usage: ICU/CCU,Surgery,Stress,Holter,EMS,Emergency Description Packaging Ctn size Adult,Wet gel,52x47mm 50pcs/pk,40pk/ctn 48x36x28cm Prewired Neonatal Recommended usage: NICU,PICU Description Packaging Ctn size Neonatal,22x22mm 3pcs/pk,10pk/box,12bx/ctn 48x22x22cm Repositionable Recommended usage: ICU/CCU,Surgery,Emergency,Cath lab,Radiology Description Packaging Adult,solid gel,32x40mm 3pcs/pk,10pk/box,12bx/ctn Diagnostic-TAB/Resting Electrode Recommended usage: Cardiology,resting ECG Description Packaging Ctn size 20x34mm 10pcs/pk,50pk/bx,10bx/ctn 30x19x23cm 23x34mm 10pcs/pk,50pk/bx,10bx/ctn 30x19x23cm
An ECG bulb with an electrode cup is a component used in electrocardiogram (ECG) machines for detecting and recording the electrical activity of the heart. Electrode Cup: The electrode cup is the part of the ECG bulb that makes direct contact with the patient's skin. It is designed to provide a conductive interface for accurately capturing the electrical signals produced by the heart. Material: The electrode cup is usually made of metal or a conductive material that ensures good electrical conductivity and signal transmission. The bulb portion may be made of plastic or silicone, providing flexibility and durability. Compatibility: ECG bulbs with electrode cups are designed to be compatible with specific models of ECG machines. They may come in different sizes and configurations to fit various electrode placements and patient needs. Application: During an ECG procedure, the ECG bulb with an electrode cup is placed on the patient's chest, limbs, or other specific locations as directed by the healthcare provider. The electrode cup makes contact with the skin, allowing the ECG machine to detect and record the electrical activity of the heart. ECG bulbs with electrode cups are essential components of ECG machines, providing a reliable interface for capturing the electrical signals of the heart during diagnostic procedures. Their design, material composition, and compatibility with ECG machines make them valuable tools in cardiovascular healthcare settings.