Power Coverage:20KW~1100Kw Rated Voltage:400V/230V Speed:1500/1800rpm Alternator:KWISE/HENGFA IP&Insulation:IP22-23&F/H Frequency:50Hz/60Hz Excitation Type:Brushless Self-Excitation Controller:Smartgen/Deepsea/Comap/Others Electronic Components:CHNT/DELEXI/Others Silent&Supper Silent60-70db At 7m Side
General features: Engine (CCEC cummins MTAA11-G3) Radiator 40oc max, fans are driven by Belt, with safety guard 24v charge alternator Alternator: single bearing alternator IP23, Insulation class h/h Absorber Dry type air filter, double fuel filter, oil filter, Coolant filter Main line circuit breaker Standard control panel Two12v batteries, rack and cable Ripple flex exhaust pipe, exhaust siphon, Flange, muffler User manual.
Cummins diesel generator sets (25kva-2250kva) Specifications: 1) Output range:20kW (25kVA) - 1800kW (2250kVA) 2) Cummins Engine models:4B3.9-G2, 4BT3.9-G2, 4BTA3.9G, 6BT5.9-G1, 6BT5.9-G2, 6BTAA5.9-G, 6CTA8.3-G, 6CTAA8.3G, NTA855G1, NT855-GA, NTA855-G1A, NTA855-G2, NTA855-G4, NT855-G2A, NTAA855-G7, KTA19-G2, NTAA855-G7A, KTA19-G3, KTA19-G4, KTAA19-G5, KTAA19-G6, KTAA19-G7, KTA38-G2, KTA38-G2A, KTA38-G5, KTAA38-G9, KTA50G3, KTA50G8, QSK60G4 ,QSK60-G8 3) Alternator model: Megaton/ Stamford/(Excitation: Brush less) 4) Water-cooled 5) 8hours operation base fuel tank 6) 230 / 400V AC, 50Hz / 60Hz, 0.8pF three-phase and four wires 7) Voltage adjust range:6% 8) Steady State Voltage regulation:1% 9) Insulation class: H 10) Protection:IP23 11) Control panel consisting of: Emergency Stop button Voltmeter and selector switch Ammeter and selector switch Frequency meter Controller with selection for auto-start, manual-start and an automatic alarm system with following (and not restricted to) features: A)Start/Stop button B)Hour run meter C)Monitor engine temperature and provides shutdown protection D)Monitor engine speed and provides optional shutdown protection E)Monitor oil pressure or level and provides shutdown protection F)Alarm output for abnormal operation 12) Sound-proof / weather-proof canopy is available 13) Detailed specification will provide upon requested Nude packing
Engine (1500rpm/1800rpm):steel base frame Alternator (50hz/60hz): starting lead-acid battery/battery connection cable 40oC radiator:output breaker Industrial muffler: intellectual control board Water/fuel separator: standard kits From 20kw to 1000kw
Cummins diesel generator are supplied with power from 30KVA to 1100KVA. 1794*980*1350
Cummins Diesel Generator Set 24GF Diesel Generator Set Data Set Type: XG-24GF Standby Power: 24KW/30KVA Prime Power: 22KW/27KVA Rated Current: 39(A) Rated Frequency: 50(Hz) Start-up time: 5ï½?6(s) Power Factor: 0.8(Lag) Rated Voltage: 400/230(V) Standard Features 1. Engine: DCEC Cummins 4B3.9-G2 2. Radiator 50â?? max 3. Fans are driven by belt, with safety guard 4. 24V charge alternator 5.Dry type air filter, fuel filter, oil filter 6. Alternator: single bearing alternator 7. IP23, insulation class H/H 8. Main line circuit breaker 9. Standard control panel 10. Absorber 11. Muffle 12. User manual
Cummins diesel generator set Genset model: hhc25 Rating power:20kw/25kva Stand-by power: 22kw/27.5kva Dimension: open type-1900x760x1340mm Soundproof type-2350x1000x1500mm Fuel tank capacity(skid base fuel tank): Open type-110l Soundproof-120l Engine:cummins Model:4b3.9g governor type: electronic Speed: 1500rpm rated power: 27kw Cylinder number and config.: inline, 4 Displacement: 3.9l Aspiration: natural intake Cooling system: water cooled Lub.Oil capacity: 11l Alternator: stamford Model:bci184f1 rating power: 22kw Power factor: 0.8 Number of bearing: single Voltage: 400/230v Voltage regulation: +/-1% Frequency: 50hz Insulation class:h Protection: ip22 Excitation system: brussless, avr Connection type: 3 phases, 4 wires, "y" type Dimensions: 2350x1000x15000mm Weight: 1165kg
Diesel Generator Set Data Set Type: XG-350GF Prime Power: 350KW/437.55KVA Rated Current: 572 (A) Rated Frequency: 50(Hz) Start-up time: 56(s) Power Factor: 0.8(Lag) Rated Voltage: 400/230(V) Standard Features 1. Engine: CCEC Cummins NTAA855-G7A 2. Radiator 50 degree max 3. Fans are driven by belt, with safety guard 4. 24V charge alternator 5. Dry type air filter, fuel filter, oil filter 6. Alternator: single bearing alternator 7. IP23, insulation class H/H 8. Main line circuit breaker 9. Standard control panel 10. Absorber 11. Muffler 12. User manual Diesel Engine Data Manufacturer: CCEC Cummins Model: NTAA855-G7A Standby Power: 407KW Rated Speed: 1500(r/min) Cycle: 4 stroke Cylinder Arrangement: 6 in line Displacement: 14L Bore and Stroke: 140*152(mm) Compression Ratio: 14:1 Governor Type: Electronic Start battery voltage: 24V DC Shipping & Payment Information Minimum Order: 1 set Supply ability: 7000 sets/year Packaging: Wooden case Shipping: Ship Delivery: 30 days Payment: T/T, L/C
Bc27(22kw, 230/380v, 50hz, 3phases4wires) open type diesel generator set 1, dece cummins water cooled engine; 2, baishan stamford type ac alternator, ip23, h; 3, 50 degree radiator with engine driven fan mounted on skid; 4, smartgen hgm6110 auto start/stop control panel; 5, chnt brand 3p bccb; 6, anti-vibration mountings; 7, 24v maintain-free batteries; 8, industrial type silencers with flexible connects and elbow; 9, with 8 hours fuel tank integrated in the bse frame; 10, test report of genrato, set of drawings and o&m manauals; 11, standard tools kit; Plastic wrap
24KW/30KVA Cummins Diesel Generator Set Cummins Series Generator/Generators/Diesel Generator/Diesel Generator Set/Silent Generator/Silent Diesel Generator/Genset Power From 20KVA up to 1500KVA, with compacted structure and best configuration. OEM CUMMINS Powered Diesel Generator Sets with its high reliability, low use and maintenance cost win the loyalty of many customers in the field of Army, transportation engineering system and mine industries. Established in 1919, headquartered in Columbus, Indiana, (USA) Cummins Inc. Serves customers in more than 160 countries and territories through its network of 680 Company-owned and independent distributor locations and more than 5, 000 dealer locations. As the largest foreign engine investors of China, Cummins possess Chongqing Cummins Engine Co., Ltd (produce M, N, K series engine) and Dongfeng Cummins Engine Co., Ltd (produce B, C, L series engine ) and produce CUMMINS engines with globally uniform quality standards. Control Systems Standard control panel is the basic configure for normally operation and usage. The advantages of this panel are easy operation, aomprehensive function and reliable protection and so on. There are indicating gauges, lamps, transfer switches and emergency stop button, etc. The control panel wil stop the whole generator set and alarm as well when malfunction appears. LED Automatic Control Panel is a kind of intelligent controller with LED displaying the operating mode of the controller and the running state of the generator sets. It can configure the control procedure and protection parameter of the generator set, and completely satisfied the automatic controlling requirement of the generator sets for the user or factory. LCD Automatic Control Panel is the configuration for nobody on duty controlling generator sets. This kind of panel adopts module control system, with large LCD screen to show the menu. The module can receive output signal from ATS and realize automatic start and stop the generator sets. 1, DCEC/CCEC Cummins Diesel Engines 2, Stamford / Leroy Somer / Marthon Alternators 3, CE Approved 4, One Year Warranty. Iron Bracket.
40KW/50KVA Cummins Diesel Generating Set Cummins Series Generator/Generators/Diesel Generator/Diesel Generator Set/Silent Generator/Silent Diesel Generator/Genset Power From 20KVA up to 1500KVA, with compacted structure and best configuration. OEM CUMMINS Powered Diesel Generator Sets with its high reliability, low use and maintenance cost win the loyalty of many customers in the field of Army, transportation engineering system and mine industries. Established in 1919, headquartered in Columbus, Indiana, (USA) Cummins Inc. Serves customers in more than 160 countries and territories through its network of 680 Company-owned and independent distributor locations and more than 5, 000 dealer locations. As the largest foreign engine investors of China, Cummins possess Chongqing Cummins Engine Co., Ltd (produce M, N, K series engine) and Dongfeng Cummins Engine Co., Ltd (produce B, C, L series engine ) and produce CUMMINS engines with globally uniform quality standards. Control Systems Standard control panel is the basic configure for normally operation and usage. The advantages of this panel are easy operation, aomprehensive function and reliable protection and so on. There are indicating gauges, lamps, transfer switches and emergency stop button, etc. The control panel wil stop the whole generator set and alarm as well when malfunction appears. LED Automatic Control Panel is a kind of intelligent controller with LED displaying the operating mode of the controller and the running state of the generator sets. It can configure the control procedure and protection parameter of the generator set, and completely satisfied the automatic controlling requirement of the generator sets for the user or factory. LCD Automatic Control Panel is the configuration for nobody on duty controlling generator sets. This kind of panel adopts module control system, with large LCD screen to show the menu. The module can receive output signal from ATS and realize automatic start and stop the generator sets. 1, DCEC/CCEC Cummins Diesel Engines 2, Stamford / Leroy Somer / Marthon Alternators 3, CE Approved 4, One Year Warranty . Iron bracket.
Diesel Generator Set Data Manufacturer: Jiangsu Starlight Electricity Equipments Co.,Ltd. Set Type: XG-50GF Standby Power: 50KW/62.5KVA Prime Power: 45KW/57KVA Rated Current: 82(A) Rated Frequency: 50(Hz) Start-up time: 5~6(s) Power Factor: 0.8(Lag) Rated Voltage: 400/230(V) Standard Features Engine: DCEC Cummins 4BTA3.9-G2 Radiator 50ºC max Fans are driven by belt, with safety guard 24V charge alternator Dry type air filter, fuel filter, oil filter Alternator: single bearing alternator IP23, insulation class H/H Main line circuit breaker Standard control panel Absorber Muffler User manual Diesel Engine Data Manufacturer: DCEC Cummins Model: 4BTA3.9-G2 Prime/ Standby Power: 55KW/ 60KW Rated Speed: 1500(r/min) Cycle: 4 stroke Cylinder Arrangement: 4 in line Displacement: 3.9L Bore and Stroke: 102*120(mm) Compression Ratio: 16.5:1 Governor Type: Electronic Start battery voltage: 24V DC Air Intake System Air Intake System: Turbo, Water/Air Cooling Max Intake Restriction: 6.2kPa Burning Capacity: 5.9m3/min Air Flow: 158m3/min Exhaust System Exhaust Gas Flow: 14.8m3/min Exhaust Temperature: 497ºC Max Back Pressure: 10kPa Fuel System Fuel System: AD type fuel pump 100%( Prime Power) Load: 216g/kwh 50%( Prime Power) Load: 231g/kwh Oil System Total Oil Capacity: 16.4L Oil Consumption: â?¤0.4g/kwh Engine Oil Tank Capacity: 14.3L Oil Pressure at Rated RPM: 350kPa Cooling System Cooling Way: Water-cooled Total Coolant Capacity: 24L Thermostat: 83-95ºC Max Water Temperature: 100ºC Alternator Data Manufacturer: STARLIGHT/ STAMFORD/ SIEMENS/ MARATHON/ ENGGA / KEPU Excitation Mode: Brushless and self- exciting Number of phase and Access Act: 3-phase 4-wire Connecting Type: "Y" type connecting Alternator Capacity: 62.5KVA Alternator Efficiencies: 95% Overload: (PRP)110% load can run 1h Protection Level: IP22-IP23 Insulation Class, Temperature Rise: H/H Telephone Influence Factor (TIF):
Model 6bt5.9-g2 Power of output/kva 100 Number of cylinder, bore, stroke(mm) 6-102x120 Displacement (l) 5.88 Oil capacity (l) 16 Type of governor Mechanical Dimension(l, w, h) (mm) 2100*800*1450 Net weight (kg) 960
Output Type:AC Three Phase Speed:1500RPM Frequency:50HZ Rated Power:100KVA/80KW Rated Voltage:400/230V Rated Current:144A Standby Power:110KVA/88KW engine brand:CUMMINS alternator brand:Engga Controller:Smartgen Fuel:Diesel Certificate:ISO9001:2008 Function:Soundproof / Waterproof canopy, ATS Cooling way:water-cooled DIMENSION:2200*800*1320MM Rated capacity of battery:120AH(2PCS) Rated capacity of circuit breaker:200A Power factor:0.8lagged Global Warranty:12 months / 1000 running hours
1.Main technical data of gensets 1.1ModelCcfj50jy 1.2Prime power50kw/63kva elf-exciting 3.5Prime voltage230v/400v 3.6Frequency50 hz 3.7Power factor0.8(lagging) 3.8Phase/wire3 phase 4 wires 3.9IsolationH Size:1850*730*1250 Weight:1000kg
20KW/25KVA Cummins Silent Diesel Generator Set Cummins Series Generator/Generators/Diesel Generator/Diesel Generator Set/Silent Generator/Silent Diesel Generator/Genset Power From 20KVA up to 1500KVA, with compacted structure and best configuration. OEM CUMMINS Powered Diesel Generator Sets with its high reliability, low use and maintenance cost win the loyalty of many customers in the field of Army, transportation engineering system and mine industries. Established in 1919, headquartered in Columbus, Indiana, (USA) Cummins Inc. Serves customers in more than 160 countries and territories through its network of 680 Company-owned and independent distributor locations and more than 5, 000 dealer locations. As the largest foreign engine investors of China, Cummins possess Chongqing Cummins Engine Co., Ltd (produce M, N, K series engine) and Dongfeng Cummins Engine Co., Ltd (produce B, C, L series engine ) and produce CUMMINS engines with globally uniform quality standards. Control Systems Standard control panel is the basic configure for normally operation and usage. The advantages of this panel are easy operation, aomprehensive function and reliable protection and so on. There are indicating gauges, lamps, transfer switches and emergency stop button, etc. The control panel wil stop the whole generator set and alarm as well when malfunction appears. LED Automatic Control Panel is a kind of intelligent controller with LED displaying the operating mode of the controller and the running state of the generator sets. It can configure the control procedure and protection parameter of the generator set, and completely satisfied the automatic controlling requirement of the generator sets for the user or factory. LCD Automatic Control Panel is the configuration for nobody on duty controlling generator sets. This kind of panel adopts module control system, with large LCD screen to show the menu. The module can receive output signal from ATS and realize automatic start and stop the generator sets. 1, DCEC/CCEC Cummins Diesel Engines 2, Stamford / Leroy Somer / Marthon Alternators 3, CE Approved 4, One Year Warranty General Data Sheet Cummins Generators 50HZ Genset Model Standby / Prime Power Engine Model No. of Cylinder Displacement (L) Oil Capacity (L) Coolant Capacity (L) Genset Size (mm) Weight (KG) KVA KW Cummins L W H HF20C 30/25 24/20 4B3.9-G2 4 3.9 11 17 1470 650 1145 650 HF30C 40/37.5 32/30 4BT3.9-G2 4 3.9 11 17 1685 650 1145 700 HF40C 62/50 50/40 4BTA3.9-G2 4 3.9 11 18 1800 670 1190 830 HF50C 70/62.5 56/50 4BTA3.9-G3 4 3.9 11 18 1900 670 1190 850 HF64C 90/80 72/64 6BT5.9-G2 6 5.9 16 29 2100 790 1320 1050 HF80C 110/100 88/80 6BT5.9-G2 6 5.9 16 29 2100 790 1400 1080 HF90C 125/113 100/90 6BTA5.9-G2 6 5.9 16 29 2200 790 1450 1150 HF108C 150/135 120/108 6BTAA5.9-G2 6 5.9 16 29 2400 840 1450 1200 HF128C 175/160 140/128 6CTA8.3-G2 6 5.9 16 30 2480 860 1450 1400 HF144C 200/180 160/144 6CTA8.3-G2 6 8.3 24 35 2480 860 1460 1650 HF160C 220/200 176/160 6CTAA8.3-G2 6 8.3 24 39 2700 950 1460 1650 HF180C 250/225 200/180 6LTAA8.9-G2 6 8.9 24 47 2700 960 1500 1800 HF200C 275/250 220/200 6LTAA8.9-G2 6 8.9 24 47 2700 960 1500 1900 HF220C 300/275 240/220 6LTAA8.9-G3 6 8.9 24 47 2700 960 1500 2050 HF280C 375/330 300/264 QSM11-G2 6 11 38 62 3110 1200 1745 2880 HF320C 450/400 360/320 NTAA855-G7A 6 14 37 65 3300 1250 1720 3050 HF360C 500/450 400/360 KTA19-G3 6 19 50 99 3310 1290 1720 3100 HF420C 575/525 460/420 KTA19-G4 6 19 50 99 3600 1290 1900 3750 HF500C 688/625 550/500 KTAA19-G6A 6 19 50 195 3800 1500 1980 4500 HF620C 850/775 680/620 KTA38-G2 12 38 135 265 3860 1600 2195 6000 HF720C 1000/900 800/720 KTA38-G2A 12 38 135 303 3860 1600 2195 7000 HF820C 1125/1025 900/820 KTA38-G5 12 38 135 309 5300 1950 2500 8500 HF1020C 1400/1275 1120/1020 KTA50-G3 16 50 177 349 5300 2150 2520 9950 HF1200C 1675/1500 1340/1200 KTA50-G8 16 50 204 349 5300 2200 2550 10500
Place of originFujian chian (mainland) Brand nameOptional Output typeAc 3phase Rated power20~1000kw Noise level Silent type7m ?75db Alternator Optinal Test time2 hrs Rated voltage230/400v ac Start systemElectric 12v/24v Speed1500~1800rpm/min Frequency 50/60 hz Warranty 1yr /1000hrs Cooled methodWater-cooled EngineOptinal ExcitationWith brush/brushless Controller system Automatic/manual
Genset Model----PCC275B Prime Rating (kw)-----200 Standby Rating (kw)---220 Rate voltage(V)---400 Rate current(A)----361 Power factor---0.8 Frequency(Hz)---50 Engine Engine Model----MTAA11-G2 Gross Engine output-Prime (kw)---224 Gross Engine output-Standby (kw)---246 Bore * stroke (mm)----125*147 Cylinders and structure----6 In line Displacement(Liter)---10.8 Compression Ratio----16.1:1 Intake way---Turbocharged/Air-Air intercooler Max intake resistance (KPa)---6.2 Air intake (m3/h)---947 Max exhaust back pressure (KPa)----10 Exhaust gas flow (m3/h)----2367 Exhaust temp (â??)-----510 Cooling way------Water Radiator & Fan Fan exhaust flow (m3/min)-----420 Coolant capacity (L)----55.4 Highest water temperature(â??)-----104 Minimum air opening to room (m2)-----2.1/1.4 Thermostat range (â??)----82-94 Max oil temperature (â??)---121 Lubrication system oil capacity (L)---36.7 Rate load fuel consumption(L/H)----51.6 Standard Governor-----Electronic Alternator Rated Voltage(V)-----400/230 Output Way----3 Phases, 4 wires Rated power factor----0.8 Exciter Brushless----Self-exciter Max voltage regulation---±1% Phase---3 Protection class---IP21-23 Insulation class---H Controller-- GC6110
New power-npc series diesel generator we provide can be warrant of its certified of origin. Especially, as oem factory we can keep perfect and reliable quality by the supports of original cummins enterprise. Rated voltage: 380v/220v Line way: 3 phases & 4 lines Frequency: 50hz Power factor: 0.8(lagging) We can also provide 60hz and other international standard requirements about diesel generator sets to comply with the demands of clients.
EAC 1000 Engine: CUMMINS Engine Model : KTA38-G2A Stand By kVA: 1000 Stand By kW : 800 Prime kVA: 909 Prime kW : 727 Rated Current : 1308 Engine - CUMMINS heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed Alternat�¶r - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis â?? ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine CUMM�°NS Engine Model KTA38-G2A Number of Cylinders 12 - V TYPE Injection System Direct Compression Ratio 14.5:1 Bore 159 Strok 159 Displacement Lt 38 Air Intake Turbocharged, Aftercooled Speed (RPM) 1500 Oil Capacity Lt 135 Standby Power kw / Hp 895 / 1199 Prime Power Hp 813 / 1089 Fuel Type Euro Diesel Governor System Electronic Cooling System Water Cooling Coolant Capacity Lt 350 Fuel Consumption (lt / h) Lt Full Load 202,3 Lt %75 LOAD 153,7 Lt %50 LOAD 103,1 Frequency Hz Power kVA 825 Voltage V 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation �±1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 9350 Weight (Open) Kg 8200 Width (Silent) Mm 2200 Length (Silent) Mm 6200 Height (Silent) Mm 2800 Fuel Tank Capacity Lt 1750 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.