Intended use: AIVD COVID-19(SARS-CoV-2) IgG/IgM Rapid Test is a single use, rapid device for qualitative detection of total antibodies against 2019 novel coronavirus (SARS-CoV-2) in human serum, plasma or whole blood specimens. The kit is intended for screening of patients suspected for infection with SARS-CoV-2, and as an aid in the diagnosis of the coronavirus disease 2019 (COVID-19). Descriptionï¼? Novel coronavirus pneumonia (NCP) or SARS-COV-2, that was officially named by the WHO as â??Corona virus disease 2019â?? (COVID-19), is a respiratory infection caused by a new virus that was first identified in late 2019. IgM/IgG Rapid Kit can specifically detect IgM and IgG antibodies of COVID-19, covering the entire course of infection and recovery period of patients. This approach improves the overall diagnosis of COVID-19 in both acute and recovery phases of illness. This kit utilizes the principle of colloidal gold immunochromatography to qualitatively detect the new coronavirus (COVID-19) IgG / IgM antibodies in human serum and plasma. Lateral flow immunochromatographic assay provides an easy workflow, short turnaround time, and rapid diagnosis of COVID-19 suspected patients. This method does not require expensive medical instruments and consumables. Just take the specimen and add it to the sample well, and then add the required amount of a diluent. The IgG / IgM antibodies in the sample will interact with the colloidal gold-labeled COVID-19 recombinant antigen on the conjugate pad. Then the conjugate pad will release re-solubilized conjugate onto the nitrocellulose membrane. The nitrocellulose membrane (NC membrane) diffuses it forward. As the sample moves along the device binding reagents situated on the nitrocellulose membrane bind to the target at the test line. If the sample contains a COVID-19 IgG antibodies, they will bind to the colloidal gold-labeled novel coronavirus recombinant antigen, diffuse forward, and then react with the anti-human IgG antibodies immobilized on the NC membrane detection line (T2 line). Similarly, if the specimen contains IgM antibodies to COVID-19, the antibodies will react with antigen-coated particles, the conjugate migrate laterally forward, and cause a colored line (T1 line). The darker the color of colloidal gold on the test line, the higher the concentration antibodies to COVID-19 in the sample. Accuracy:ï¼?> 90% Specificity: 97% Basic Protocolï¼? 1. Remove the test specimen, required reagents from storage conditions, and equilibrate to room temperature. 2. Unpack the aluminum foil bag, place the test horizontally on the table and number it. 3. Add 10ul serum, plasma or whole blood sample to the sample well with a pipette or a dropper. Slowly add 2 drops of sample dilution (about 60uL) to the sample well. 4. Read the results within 10-15 minutes after adding the sample, and the results will be invalid after 30 minutes.
COVID-19 Rapid Test Kit IgG + IgM (Colloidal Gold) comes in packs of 40 tests and contains: GCMS manufactures COVID-19 antigen test kit, the GENEDIA W COVID-19 Ag which is listed on the EU common list, also with GMP and ISO certifications. GENEDIA W COVID-19 Ag is unaffected based on the in-silicon analysis of the mutations in the nucleocapsid (N gene) of Omicron viruses. Letter of statement is available upon your request. To get over COVID-19 pandemic, especially the recent Omicron breakout, currently we are doing big promotions for three kinds of COVID-19 Ag kit. All are in stock and available right away. 1. Nasopharyngeal 2. Nasal 3. Saliva Price and Minumum Quantity Price FOB in USD: negotiable 0.8 to 1.8Minimum Order Qty: None Pieces Production Capacity: 3,000,000/monthPackaging: 20 Tests/kit, 30 Kits/box, 12 Boxes/pallet Sample: Available. Sample Cost Born By Supplier Product Model And Origin Brand: GENEDIAModel: 643G-S (Saliva) Seller Code: Genedia w covid 19 agHS Code: 3002.15 Standards: Ce Competitive Advantages Allow wider testing with fast test time (10 minutes) All necessary materials provided / no equipment needed Sensitivity: 93.33%, specificity: 100% Free sample. no moq. price is negotiable. customized packing. Other Details 20 tests / kit 24 months from the date of manufacture 2 ~ 30c(35.6 ~ 86f) available for room temperature deliver In stock. fast delivery. 1 x Instructions for Use Manual 40 x Test Cassettes 1 x Buffer 40 x Dropper
INTENDED USE For qualitative detection and differentiation of IgM and IgG antibodies to SARS-CoV-2 in serum, plasma (EDTA, sodium citrate and lithium heparin) or fingerstick whole blood, venous whole blood specimens from patients suspected of COVID-19 infection. FEATURES Coated with carefully selected specific Nucleocapsid and Spike protein antigen. Detection for IgM and IgG antibodies simultaneously. Simple operation, easy result interpreted. Rapid test within 15 minutes. RESULTS INTERPRETATION Positive: 1. The presence of 3 red lines (T1, T2 and C) within the reaction window, no matter which band appears first, indicates presence of both SARS-CoV-2 IgM and IgG antibodies. 2. The presence of 2 red lines (T1 and C) within the reaction window, no matter which band appears first, indicates presence of SARS-CoV-2 IgM antibody. 3. The presence of 2 red lines (T2 and C) within the reaction window, no matter which band appears first, indicates presence of SARS-CoV-2 IgG antibody. Negative: 1. The presence of line (control line) only within the reaction window indicates that no SARS-CoV-2 antibodies are detected. The results is negative. Invalid: 1. If the control(C) line is not displayed in 10-15 min, regardless of whether T1 and/or T2 line is present, the test result is invalid. It is recommended that the specimen should be re-tested. 2. The test result is invalid after 15 min. CLINICAL PERFORMANCE - Positive Percent Agreement (PPA) = 91.07% (153/168) (95% CI: 85.70%-94.92%). - Negative Percent Agreement (NPA) = 95.37% (103/108) (95% CI: 89.53%-98.48%). - Overall Rates of Agreement (ORA) = 92.75% [(153+103)/ (168+108)] (95% CI: 89.03%-95.52%). [Product Name]: SARS-CoV-2 IgM/IgG Duo Test [Product Code]: Cat# FP-319 [Sample Type]: Whole blood /Plasma/Serum [Sample Volume]: 20L /10L/10L [Detection Method]: Colloidal Gold [Reaction Time]: 10-15min [Packing Size]: 1T x 20 cassettes per box + Sample diluent 1 vial x 5mL. [Storage Condition]: 2oC ~ 30oC [Shelf Life]: 12 months [CE Mark Registration No.]: RPS/499/2021.
Angiten-COVID-19 Virus Test Kit (Colloidal Gold) Quantity of box: 25 persons/box Brand: Easysweet NMPA (National Medical Products Administration): Approved CE: with CE mark BfArM: listed Test Method: Antigen Test Result Time: 10-15 mins Sample Type: Nasal Swab Sensitivity: 96.70% Specificity: 100% Accuracy: 98.94% Shelf Life: 24 months Storage Temperature: 2-30 Degree Celsius Country of Origin: Made in China Additional Information: Production Capacity: 1 million Delivery Time: 10-15 days Packaging Details: 25 tests in a pack, 40packs/ carton Angiten-COVID-19 Virus Test Kit is an in vitro diagnostic rapid test for the qualitative detection of SARS-CoV-2 antigen (Ag) in human nasopharyngeal swab specimens from individuals who meet COVID-19clinical and / or epidemiological criteria. It can be used by professional only. Price and Minumum Quantity Price FOB in USD: NegotiableMinimum Order Qty: 10000 Production Capacity: 1000000Packaging: 25 Persons/box Sample: Available. Sample Cost Born By Buyer Product Model And Origin Brand: Easysweet HS Code: 3822009020 Standards: Ce Competitive Advantages Best price with shortest delivery time Best price with shortest delivery time Best price with shortest delivery time Best price with shortest delivery time Other Details Angiten-covid-19 virus test kit (colloidal gold) Angiten-covid-19 virus test kit (colloidal gold) Angiten-covid-19 virus test kit (colloidal gold) Angiten-covid-19 virus test kit (colloidal gold)
Access Bio Care Start Covid-19 Rapid Antigen Test Kit Product Details: Number of Reactions(Preps) per Kit : 1 Brand : Access Bio Test Method : Antigen Test Result Time (Rapid Kits) : 10 min Sample Type ; Nasal Swab Packaging Size : 20 Test Kits/Box Packaging Type : Box The CareStart COVID-19 Antigen test is a lateral flow immunochromatographic assay intended for the qualitative detection of the nucleocapsid protein antigen from SARS-CoV-2 in nasopharyngeal or anterior nasal swab specimens directly collected from individuals who are either suspected of COVID-19 by their healthcare provider within first five days of symptom onset, or from individuals without symptoms or other epidemiological reasons to suspect COVID-19 when tested twice over two or three days with at least 24 hours and no more than 48 hours between
Covd-19 IgG/IgM Rapid Test Cassette (Whole Blood/Serum/Plasma) is a solid phase immunochromatographic assay for the rapid, qualitative and dierential detection of IgG and IgM antibodies to 2019 Novel Corona Virus in human whole blood, serum or plasma. Specification.jpg Product: Rapid Diagnostic Test Kit Item: Corona Virus Test Kit Specimen: Whole Blood/Serum/Plasma Format: Strip/Cassette Port of Loading: Shanghai OEM and ODM: OEM/ODM Welcome Shipping: By UPS, FEDEX, DHL, TNT, by air or by sea MOQ for Private label: Low MOQ 1600 boxes, Please contact us. Note: Store this product in a cool and dry place, avoid direct sunlight, stay away from places that children can contact, and avoid eye contact. If you have allergies to this product, please stop using and consult a doctor. COVID-19 Corona Virus Rapid Test Kit11.pngCOVID-19 Corona Virus Rapid Test Kit12.png
We are manufacturer and supplier of high quality molecular diagnostics product among covid 19 detection kits consisting of: 1]. covid 19/sars cov 2 nucleic acid test kits to detect the covid 19 standard, uk and south africa variants (rt pcr). 2]. covid 19/sars cov 2 antigen rapid test kits. 3]. covid 19/sars cov 2 antibody (igg/igm) rapid test kits. in addition to a product of quality, we offer very competitive price and we have high production capacities to assure a continuous supply of product without shortage..Manufacture, oem
[Intended Usage] This kit is used for the in vitro qualitative detection of suspected cases of pneumonia caused by New Coronavirus infection, patients with suspected clusters, other patients who need to be diagnosed or differentially diagnosed with the New Coronavirus infection, and nasopharyngeal swabs, oropharyngeal swabs, and bronchoalveolar lavage fluid samples of patients with mutation beads for the New Coronavirus ORF1ab and N gene, S gene N501Y mutation and S gene E484K mutation sites. [Storage Conditions & Validity] 1. The kit should be stored frozen at -20 and protected from light; the expiration date is 6 months; the production date and expiration date are shown in the outer packaging box. 2. Avoid repeated freezing and thawing of the kit and the number of freezing and thawing shall not exceed 7 times. 3. After opening, the bottles should be stored at -20 and protected from light. The number of bottles opening times should not exceed 7 times, which will not affect the use within the validity period. [Applicable Instruments] 1. This kit has been validated on ABI7500 quantitative fluorescence PCR instrument. 2. For other models not listed, relevant experiments have not been performed or completed for this kit. If users need to use this type of instrument platform to carry out the detection of this reagent, please contact our Technical Department at for relevant support. NB: The other devices can include quantitative fluorescence PCR platforms with FAM, VIC, ROX and Cy5 channels. [Sample Requirements] 1. Nasopharyngeal swabs, oropharyngeal swabs and other methods are used to obtain samples, and it is recommended to use commercial virus sampling kits for sample collection devices. [Test Results Interpretation] 1. Negative and positive controls should be tested in each experiment and the test result can be determined only when the controls meet the quality control requirements. 2. When FAM, VIC and ROX channels are positive, Cy5 channel result may be negative due to the system competition. 3. When the internal standard result is negative, if the FAM, VIC and ROX signals of the test sample are also negative, the test result of the sample is invalid, and the cause should be found and eliminated, and the experiment repeated for this sample. [Product Performance Index] 1. Precision: The coefficient of variation Intra-batch / Inter-batch, Intra-day / Inter-day among different operators shall not be higher than 5.0%. 2. Coincidence rate of negative positive controls: The coincidence rate of positive controls and negative controls is 100%. 3. Minimum detection limit: The minimum detection limit of this kit is 500 copies/mL. [CE Mark Registration No.]: RPS/499/2021. [EC REP.]: CMC MEDICAL DEVICES & DRUGS S.L. C/ Horacio Lengo n18, C.P 29006, Milaga, Spain.
For in vitro qualitative detect of Covid-19 antigen in nasal(NS) swab specimens directly from individuals who are suspected of COVID-19 by their healthcare provider within the first 5 days of the onset of the symptoms. This test is only provided for use by clinical laboratories or to healthcare workers for point-of-care testing, and not for at home testing. 1.Easy to collect samples simple operation without professional equipment. 2.The test results are available in 15 minutes, and the test results are clearly visible. 3.Convenient transportation and low price, higher accuracy. 4.Suitable for large-scale rapid screening. Shelf life: 24 Months Test Result time: 10 Mins Packing: 25 Pieces per Box
Cat. No : 5513C. COVID-19 serology test.Cellex qSARS-CoV-2 IgG/IgM Rapid Test.qSARS-CoV-2 IgG/IgM Rapid Test Cassette.FDA Grants Emergency Authorization for First Rapid Antibody Test for COVID-19
SARS-CoV-19 IgG/IgM test kit (15min showing result) Manufacturer: Guangzhou Wanfo Biotech Co., Ltd. a China listing company Certificates: CE certificate, China NMPA approval (export allowed), no FDA approval The price is $5.5/test (FOB) Max delivered quantity: 100,000/weekly More details please enquire Barry Liu whatsapp: +8617810331113 sample available: 20 test & DHL delivery: $200 Download introductions: https://kdocs.cn/l/sLLC9O6rc
FAST: Results in under 2 minutes ACCURATE: 99.9% specificity and 98.7% sensitivity EASY TO USE: Convenient for testing at home PAINLESS: Simple and painless saliva collection RELIABLE: 24-Hour RT-PCR Confirmation (100% specific and 100% sensitive) 99.9% specificity. Test specificity this high ensures that almost all the people who are not infected get a negative test result with the Sensiva React Rapid Covid-19 Testing Kit. Using a fast and accurate test such as this one is vital when we are trying to stop virus transmission and protect general health. 98.7% sensitivity Test sensitivity refers to the percentage of infected people who get a positive test result. In our case that means that 98.7% of people with an infection get a positive test result. How to use it? Step 1 â?? Do the test Sensiva React Rapid Test is a simple test that can be� easily done at home. It is convenient and� painless� since it requires you to collect a saliva sample instead of a nasal swab. How to do it? First, use the mobile application to scan the QR code to register. After that, collect a saliva sample and add it into the saliva hole in the reader device before adding the liquid solution. You will be able to interpret your� results in under 2 minutes. Watch a video with detailed instructions on how to do the test in the video below. Please follow the instructions carefully to obtain a valid test result. Step 2 â?? Get RT-PCR confirmation in 24 hours You can use the prepaid shipping label and send the saliva sample used for the rapid test to us. You will get an official PCR result (100% sensitivity and 100% specificity) in 24 hours. Our lab is certified under the Clinical Laboratory Improvement Amendments (CLIA), so you can rely on us to provide you with accurate and reliable test results. Who is Sensiva React Rapid Covid-19 Test for? Sensiva React Rapid Covid-19 Test is designed for patients with COVID-19 symptoms or those who are asymptomatic but suspected of having exposure. Its easy-to-follow instructions make it convenient for testing at home. The kit contains: (1) Specimen Tube (1) Saliva Funnel (1) Dropper (1) Bio-hazard bag with absorbent pad (1) Lateral flow device (1) 5ml EZ-Tear Saline Solution (1) 0.3ml EZ-Tear Buffer Solution (1) Written Instruction Card
INTENDED USE For qualitative detection of the nucleocapsid protein antigen of SARS-CoV-2 in nasopharyngeal and nasal swab, and saliva specimens from individuals and is aid in rapid diagnosis of patients with suspected SARS-CoV-2 infection. FEATURES Carefully selected special monoclonal antibody to the nucleocapsid protein antigen from SARS-CoV-2. Various applicable specimen: Nasopharyngeal swab, Nasal swab and Saliva. Easy to use, easy results interpretation by naked eyes. Test result available within 15minutes. TEST PROCEDURE: Very simple as per the instructions stated on the manual inserted in the kit. RESULTS INTERPRETATION Positive: A red line appears on the test line (T) and the control line (C). NOTE: A positive result does not rule out co-infections with other pathogens. Negative: Only the control line (C) appears, and no red line appears on the test line (T). NOTE: A negative result does not exclude infection. Invalid: There is no red line at the position of the control line (C). Regardless of whether the TEST line (T) is displayed, it is an invalid result and the sample should be tested again. CLINICAL PERFORMANCE SARS-CoV-2 Antigen Test Kit Comparator Method (NTA) Positive Negative Total Positive 97 0 97 Negative 3 100 103 Total 100 100 200 - Positive Agreement (95% CI): 97/100 97% (83.3% - 99.9%) - Negative Agreement (95% CI): 100/100 100.0% (95.5% - 100%) - LoD: 1.5�??102 TCID50 for virus lysate, 10pg/mL for recombinant Nucleocapsid protein antigen. - Compared with NAT method, the specimens with the Ct range between 30-35 will be detectable. - No cross-reactions with various bacteria, viruses and fungi normally available in respiratory track. - Positive Agreement (95% CI): 97/100, 97% (83.3% - 99.9%) - Negative Agreement (95% CI): 100/100, 100.0% (95.5% - 100%). [Product Name]: SARS-CoV-2 Antigen Test [Product Code]: Cat# FP-318 [Sample Type]: Nasopharyngeal swab / Nasal swab /Saliva [Detection Method]: Colloidal Gold [Reaction Time]: Within 15min [Packing Size]: 1T x 20 cassettes + Sample buffer 20 vials x 0.5mL + 20 samples collection swab x 1. [Storage Conditions]: 2*C ~ 30*C [Shelf Life]: 12 months [CE Mark Registration No.]: RPS/99/2021.
SENNA PODS Senna has been used as a traditional medicine by ancient cultures all over the world for millennia. Senna is an Arabian name and 9th century writings describe how it was used extensively by Arabian physicians. According to a rare Egyptian medical papyrus, dating to the 16th century BCE, Senna was prescribed by the physicians for their distinguished patients. In North America, native tribes used the seeds (pods) as a mucilaginous medicine for sore throat. The Cherokees used the bruised root, moistened with water, for dressing sores. They also used it in a tea to cure fevers with black spots and paralysis as symptoms. Senna Pods Uses: Taking senna by mouth is effective for short-term treatment of constipation. Senna is an FDA-approved nonprescription drug for adults and children ages 2 years and older. However, in children ages 3-15 years, mineral oil and a medication called lactulose might be more effective than taking senna. Senna also appears to be effective for treating constipation when used in combination with psyllium or docusate sodium. In elderly people, senna plus psyllium is more effective than lactulose for treating ongoing constipation. Senna plus docusate sodium is effective for treating constipation in the elderly and in people who have undergone anorectal surgery. Taking senna appears to be as effective as lactulose, psyllium, and docusate for relieving constipation in people taking opioids or loperamide. Senna Benefits Constipation The most famous use of this herb is as a laxative and a purgative. It is now known that the laxative effects of Senna are due to anthraquinone glycosides known as sennosides. These compounds stimulate intestinal contractions that lead to the rapid expulsion of waste matter. Senna may also be able to soften the stool by assisting the large intestine to absorb more water and adding bulk to faeces. This allows for bowel movements that are quick and smooth as waste passes through the large intestine. Colon Cleanse Senna is often used to clear the bowel before diagnostic tests such as colonoscopies. Cleansing the colon is believed to improve nutrient uptake and support overall colon health. Anti-Parasitic:Senna also works as an effective vermifuge to destroy parasites and expel worms from the intestinal tract. It works best when combined with other anthelmintic herbs (used in the treatment of roundworm), such as ginger or fennel. These herbs increase regularity and reduce the chance of bowel cramps due to Sennaâ??s strong action. Digestive Health In the case of indigestion, Senna contains natural enzymes that help to restore gastric juice secretions in the stomach. Senna, if used in the proper dosage for certain periods of time, has shown potential in reducing irritability in the intestines by improving overall digestion. Senna also contains the anti-inflammatory compound resveratrol which can help to soothe inflammation in the gastrointestinal tract. Skin Health
Product Details: Number of Reactions(Preps)/Kit ; 25 Brand : Cellex Test Method : (SARS-CoV-2) IgM/IgG Rapid Antibody Result Time (Rapid Kits) 30 minutes Time To Result 15 mins Cat. No : 5513C COVID-19 serology test.Cellex qSARS-CoV-2 IgG/IgM Rapid Test.qSARS-CoV-2 IgG/IgM Rapid Test Cassette.FDA Grants Emergency Authorization for First Rapid Antibody Test for COVID-19
Corona viruses are enveloped RNA viruses that are distributed broadly among humans, birds and other mammals, that cause respiratory, enteric, hepatic, and neurologic disease. SPECIFICATIONS: Whole blood/serum/plasma may be used for testing. Results available in only 15 minutes. Easy to use. Result can be read visually. No need for an analyser. Cost effective method for assisting in screening COVID-19 disease.
Anti-SARS-CoV-2 Rapid Test, COVID-19 1. Easier: No special equipment needed, Intuitive visual interpretation. 2. Rapid: Quick sampling by fingertip blood, Results in 10-15min. 3. Accurate: Results with IgG and IgM respectively. 4. Application: as screening tool for potential suspect patients in large numbers. Testing kit is FDA Emergency Use Authorization (EUA) Approved Testing kit is CE MARKED-IVD * Instruction for Use * Interpretation Guide * SARS-CoV-2 immunoassays * Accuracy of the Anti-SARS-CoV-2 Rapid Test Kit * Anti-SARS Rapid Test Brochure * COVID-19 Catalog * EUA Approval Letter * Fact Sheet for Healthcare Providers * FDA Letter * Fact Sheet for Recipients * FAQ * CE IVD Notification Certificate Antibody Performance Measure Estimate of Performance 95% Confidence Interval IgM Sensitivity (PPA) 95.7% (289/302) (92.8%; 97.5%) IgM Specificity (NPA) 99.7% (311/312) (98.2%; 99.9%) IgG Sensitivity (PPA) 99.0% (299/302) (97.1%; 99.7%) IgG Specificity (NPA) 99.4% (310/312) (97.7%; 99.8%) Combined Sensitivity (PPA) 99.0% (299/302) (97.1%; 99.7%) Combined Specificity (NPA) 99% (309/312) (97.2%; 99.7%) Combined PPV at prevalence = 5% 84.4% (64.6%; 94.6%) Combined NPV at prevalence = 5% 99.9% (99.8%; 100%) Testing kit is FDA Emergency Use Authorization (EUA) Approved Testing kit is CE MARKED-IVD * Instruction for Use * Interpretation Guide * SARS-CoV-2 immunoassays * Accuracy of the Anti-SARS-CoV-2 Rapid Test Kit * Anti-SARS Rapid Test Brochure * COVID-19 Catalog * EUA Approval Letter * Fact Sheet for Healthcare Providers * FDA Letter * Fact Sheet for Recipients * FAQ * CE IVD Notification Certificate
AIVD Biotechs COVID-19 Ag test is a lateral flow immunoassay intended for the qualitative detection of nucleocapsid protein (NP) antigen from SARS-CoV-2 in direct nasal swabs from individuals suspected of COVID-19. Description This kit utilizes the principle of latex bead immunochromatography to qualitatively detect the new coronavirus (COVID-19) Np antigen in human nasal swabs. Lateral flow immunochromatographic assay provides an easy workflow, short turnaround time, and rapid diagnosis of COVID-19 suspected patients. The test contains latex bead conjugate pad and a membrane strip pre-coated with antibodies specific to SARS-CoV-2 antigen on the test lines (T). If SARS-CoV-2 antigen is present in the specimen, a visible band appears on the test lines (T) as antibody-antigen-antibody latex bead complex forms. The control line (C) is used for procedural control and should always appear if the test is performed correctly. This method does not require expensive medical instruments and consumables. Just take the specimen and add it to the sample well. If sample contains the antigen, it will interact with the latex bead-labeled COVID-19 anti-SARS-COV-2 NP antibodies on the conjugate pad. Required components 1. A foil pouch with a desiccant and a single-use test card, 1 piece 3. Sterile swab, 1 piece 3. Extraction buffer tube (1 ml), 1 tube. 4. Instructions for use, 1 piece. Specimen requirements: 1. Nasopharyngeal swab specimen. 2.Specimen should be tested as soon as possible upon collection. If the sample has to be stored, store the swab sample at room temperature for up to 1 hour or 2~8â?? for up to 4 hours prior to testing. Specimen preparation 1. Insert the extraction buffer tube into the tube rack, make sure that the sample tube is firmly upright and touches the bottom of the rack. 2. Insert the swab into an extraction buffer tube. 3. Gently stir the swab in the tube, and then left swab inside the tube for 1 minute or Mix on the vortex mixer for about 30 seconds, 4. The sample should be tested immediately after collection. If it cannot be tested in time, it should be stored in the virus transport matrix. The specimens can be stored at 2-8C for 4 hours Basic Protocol Step 1: If the sample is refrigerated, remove the sample to be tested and the required reagents from the storage conditions, equilibrate to room temperature (15~30C) Step 2: When preparing to test, open the aluminum foil bag, take out the test card, and lay it flat on a table. Step 3: Mark the sample number on the test card, Step 4: Using pipette add 50ul of the sample into a sample well on the device, Step 5: Read the result within 15 minutes, Please read the result after 15 minutes. After observing and recording the result, please discard the test card to avoid affecting the result judgment. Do not read test results after 30 minutes. It may give false results.